Page 1
| Getting Started Guide P/N 068974-002
420 Data Collection PC fi latermec A UNOVA Company
Page 2
Intermec Technologies Corporation 6001 36th Avenue West P.O. Box 4280 Everett, WA 98203-9280 U.S. service and technical support: 1-800-755-5505 U.S. media supplies ordering information: 1-800-227-9947 Canadian service and technical support: 1-800-688-7043 Canadian media supplies ordering information: 1-800-268-6936 Outside U.S. and Canada: Contact your local Intermec service supplier.
The information contained herein is proprietary and is provided solely for the purpose of allowing customers to operate and/or service Intermec manufactured equipment and is not to be released, reproduced, or used for any other purpose without written permission of Intermec. Information and specifications in this manual are subject to change without notice.
Contents What Is the 5020 Data Collection PC? 5 Models and Options 6 Equipment You Need to Get Started 6 Getting the 5020 Up and Running 7 Unpacking the 5020 7 Charging the Main Battery Pack 8 Installing the Main Battery Pack 8 Charging the Bridge Battery 10 Turning On the 5020 11 Verifying That the 5020 is Operating Correctly 12
2000 by Intermec Technologies Corporation All Rights Reserved
Connecting and Configuring the 5020 13 Configuring the 5020 14 Developing Applications for the 5020 17
The word Intermec, the Intermec logo, JANUS, IRL, Trakker, Antares, Universal Access Point, UAP, TE2000, Data Collection Browser, dcBrowser, Data Collection PC, Adara, Duratherm, EZBuilder, Precision Print, PrintSet, Virtual Wedge, and CrossBar are either trademarks or registered trademarks of Intermec Technologies Corporation.
Using a PC Card 18
Throughout this manual, trademarked names may be used. Rather than put a trademark ( or ) symbol in every occurrence of a trademarked name, we state that we are using the names only in an editorial fashion, and to the benefit of the trademark owner, with no intention of infringement.
Using a Compact Flash Card 19 Booting the 5020 19 Using the Keypad 20 Entering Keypad Characters 20 Adjusting the Backlight, Contrast, and Volume 21 Using the Pointer 21 Learning About the Installed Software 22 Specifications 23 Where to Find Other Information 25
2
3
Page 3
What Is the 5020 Data Collection PC? The 5020 Data Collection PC™ incorporates Intermec’s high-performance wireless LAN technology, bar code scanning, and power management features into a hand-held computer. The 5020 is engineered to take full advantage of the Microsoft Windows CE operating system. The 5020 supports standard programming tools, such as Visual Basic, Visual C++, JScript, and HTML. From their desktops, support staff can remotely configure the 5020 by using a Web browser to access the 5020 device management software. 7
1
20
50
2 6
3 5 5020GSG008.eps
4
The 5020 is ergonomically designed for one-handed operation to make data collection easy and includes these features:
➀ 320 x 240 pixel grayscale screen, angled for easy viewing. ➁ Keypad with 43 keys to support data collection. The 5020 ships with a keypad to match the language you ordered.
➂ IrDA (Infrared Data Association) port for serial or IrDA communications.
➃ Handstrap for easy one-handed operation. ➄ Rechargeable lithium-ion main battery pack (sold separately) for power.
➅ Integrated scanner or tethered scanner port. ➆ PC card slot for radio, serial communications, modem, Ethernet, or memory. The radio frequency (RF) version of the 5020 ships with the radio installed.
4
5
Page 4
Models and Options
Getting the 5020 Up and Running
The 5020 family of Data Collection PCs includes these models:
Follow these steps to start using your new 5020:
50
Batch The basic 5020 has a Type II PC card slot and supports the use of Type I and Type II 16-bit memory and input/output (I/O) cards.
20
0 502
RF The RF version of the 5020 is available with a frequency hopping spread spectrum radio or a direct sequence radio.
1 Unpack the 5020 and documentation. 2 Charge the main battery pack. 3 Install a charged main battery pack. 4 Wait for the bridge battery to become fully charged (about 72 hours). 5 Turn on the 5020. 6 Verify that the 5020 is operating correctly.
These options are available for the 5020:
•
Integrated scanner (standard, long-range, high density, or high performance) or tethered scanner port
• • •
Keypads to support western European languages Asian character sets Compact flash memory card
These steps are described in detail in the next sections.
1 Unpacking the 5020 When you remove the 5020 from its box, save the box and shipping material in case you need to ship or store the 5020. Check the contents of the box against the invoice for completeness, and contact your local Intermec service representative if there is a problem.
Equipment You Need to Get Started
5020 Data Collection PC
20 50
To use the 5020 Data Collection PC, you need this equipment: Lithium-ion main battery pack (Part No. 068537, sold separately)
St ar te d
5020 Col Data ectio n PC Loca l Area
Syst ems
Divis ion
5020
20 50
(Optional) L5020 Serial Communications Adapter and power supply (Part No. 065236) or D5020 Communications Dock Note: Intermec recommends that you keep at least two main battery packs on hand so that you can use one main battery pack while the other is being recharged. You should keep a main battery pack in the 5020 at all times to reduce the risk of data loss and to maximize the useful life of the 5020.
6
G ui de
Z2400 battery charger
G et tin g
• • •
Information packet
5020GSG009.eps
These items should be in the information packet:
• • • • • • •
Getting Started Guide (this document) Handstrap Authorized Service Location sheet Safety supplement Microsoft software agreement Laser warning label set (5020s with integrated scanners only) Sheet of four PC card extraction tabs (batch 5020s only)
7
Page 5
2 Charging the Main Battery Pack
2.
The main power source for the 5020 is a 1500 mAh lithium-ion battery pack (Part No. 068537). Before you can use the 5020, you must fully charge the main battery pack. The 5020 will not operate without a main battery pack even when it is connected to an AC power source using a D5020 or an L5020.
Open the battery door by pushing down on the battery door latch and sliding it toward the top end of the 5020. Lift up the top edge of the battery door and remove it. Top
Latch Battery door
To charge the main battery pack
•
Place the main battery pack in an empty slot in the battery charger. The main battery pack is fully charged in about 3 hours. For help, see the documentation that came with your battery charger.
You can also use the D5020 Communications Dock or the L5020 Serial Communications Adapter with power supply to trickle-charge the main battery pack. For help, see the D5020 Communications Dock Getting Started Guide (Part No. 068976) or the L5020 Serial Communications Adapter Quick Reference Guide (Part No. 068978).
5020GSG003.eps
3.
Place the main battery pack into the battery compartment with the contacts pointed toward the bottom end of the 5020.
4.
Push the main battery pack down until it locks into the connectors on the bottom of the battery compartment.
Replace the main battery pack with Part No. 068537 only. The use of any other battery pack may present a risk of fire or explosion. Contact your local Intermec sales representative for replacement main battery packs. DISPOSE OF USED MAIN BATTERY PACKS PROMPTLY. KEEP AWAY FROM CHILDREN.
5020GSG004.eps
3 Installing the Main Battery Pack
5.
Insert the top edge of the battery door into the top of the battery compartment. Push the door down to close it over the compartment.
Install the fully-charged main battery pack into the 5020.
6.
Push the battery door latch down and slide it toward the bottom end of the 5020 to lock the door in place.
To install the main battery pack 1.
The 5020 ships with the handstrap installed. Push the top clip of the handstrap down and forward to unhook it, and position the strap away from the battery compartment.
The 5020 initializes after you install a charged main battery pack. The green LED above the screen flashes until initialization is complete.
20
LED
50
5020GSG016.eps
8
5020G027.eps
9
Page 6
7.
Hook the top clip of the handstrap over the dowel pin on the top of the 5020 and set it in place.
5 Turning On the 5020 The 5020’s on/off key is the yellow f key in the lower right corner of the keypad.
5020GSG016.eps
Tab key
Backlight key (contrast and volume control)
Scan button
Reset switch
Arrow key
Note: The handstrap works best if it crosses the entire back of the hand and not just the fingers. The top end of the strap may be hooked on either the left or right side of the 5020 so you can use either hand.
I
Space key
4 Charging the Bridge Battery The 5020 comes with a rechargeable bridge battery that maintains the contents of RAM while the main battery pack is being replaced. For more information about the bridge battery, see the 5020 Data Collection PC User’s Manual (Part No. 068975).
Enter key $
Control key
Delete key
Escape key Alt key
Shift/caps lock Modifier keys
IMPORTANT: The 5020 is shipped with a discharged bridge battery. Do not rely on the bridge battery to maintain the contents of RAM until it has been fully charged.
•
On/Off key
5020G023.eps
To turn on the 5020
•
Press f . The 5020 desktop appears.
The bridge battery recharges from the main battery pack or recharges from the AC power source.Wait until the bridge battery is fully charged before proceeding to the next section. It takes 72 hours at room temperature to charge a discharged bridge battery. Note: You should always keep a charged main battery pack installed in the 5020 to maximize the life of the bridge battery.
10
11
Page 7
When you press f to turn off the 5020, the PC does not actually shut off, but goes into Suspend mode. In Suspend mode, the 5020 continues to power all memory but turns off the power to most of the hardware. This mode is referred to as “off” in the rest of this guide. When you press f to turn on the 5020, the PC resumes where it was when you turned it off.
4.
Scan the Test Bar Code by pushing the Scan button on the keypad or by pulling the trigger on the handle if the optional handle is installed. If you have a tethered scanner, see your user’s guide for directions. Direct the beam so that it falls across all bars in the bar code label.
The 5020 automatically turns off after 5 minutes if there is no activity. Press f to turn it back on. For more information on the Automatic Shutoff feature, see the 5020 Data Collection PC User’s Manual.
Test Bar Code
*12345*
6 Verifying That the 5020 is Operating Correctly
*12345*
After successfully reading the label, the 5020 emits a high beep and the green LED lights for about a second.
Verify that the 5020 is operating correctly by scanning a bar code label. To scan a bar code label 1.
Press f to turn on the 5020.
2.
Press C 3 to open the Start menu.
Hold the 5020 at a slight angle a few inches from the Test Bar Code, with the laser scan window pointing towards the bar code.
5.
To check that the 5020 decoded the bar code correctly, make sure 12345 appears in the Part Number field.
6.
Press r to select the Exit button and press e to exit DCPC Demo.
Connecting and Configuring the 5020 You can connect the 5020 to your network in several ways:
3.
Press ] to select Programs, then press } to select DCPC Demo, and press e (Enter). The DCPC Demo screen appears.
•
Use the IrDA port to transfer data between the 5020 and a host computer.
•
Use the radio on an RF 5020 to communicate with other RF devices in your network.
•
Use an Ethernet or serial I/O PC card (purchased separately) to communicate with other devices in your network.
To use the IrDA port
•
Use the D5020 Communications Dock or the L5020 Serial Communications Adapter. For help, see the 5020 Data Collection PC User’s Manual or the guide that shipped with your D5020 or L5020 accessory.
•
Line up the 5020 IrDA port to the IrDA port on another device.
The 5020 can communicate over an RF or Ethernet network using either UDP Plus through the DCS 30X or TCP/IP to your host computer. Before connecting the 5020, you need to configure the network.
12
13
Page 8
To configure your RF or Ethernet network
•
For a TCP/IP network, configure the host computer.
•
For a UDP Plus network, configure the DCS 30X. For help, see the manual that shipped with your server.
•
If your 5020 has a radio, configure the access point. For help, see your access point user’s manual.
To use an Ethernet or serial I/O card
•
6.
Press r to move from field to field. Set the correct date and time using the arrow keys.
7.
Press e. A confirmation dialog box prompting you to apply changes appears.
8.
Press e to continue. The Communications dialog box appears with the default baud rate (115200) selected.
Install an Ethernet or serial I/O PC card in your 5020. For help, see “Using a PC Card” later in this guide. Connect your 5020 to the network with an appropriate cable.
Note: If your 5020 is not connected to a D5020 Communications Dock or L5020 Serial Communications Adapter, a baud rate message appears. Press e. The Communications dialog box appears without a baud rate selected.
Once your 5020 is connected to the network or device, you are ready to configure the basic parameters on the 5020. For help, see the next section.
Configuring the 5020 The next instructions explain how to configure the 5020 using the Fast Config application on the 5020. For other configuration methods, see the 5020 Data Collection PC User’s Manual. Note: Ask your network administrator if you have questions about your network’s configuration. To run the Fast Config application 1.
Press f to turn on the 5020.
2.
Press C 3 to open the Start menu.
3.
Press ] to select Programs and press }.
4.
Press e to start Fast Config. The Welcome screen appears.
5.
Press e. The Date and Time dialog box appears.
14
9.
Press e. The Network dialog box appears. Note: If you are using a batch 5020 without an Ethernet or serial PC card, the Identification dialog box appears. Go to Step 15.
10. If you are using a DHCP server, press e. The WINS dialog box appears. If you are not using a DHCP server, press s to clear the check mark from the box. You must enter values in the IP Address, Subnet Mask, and Default Router fields. Press r to move the cursor from field to field. Enter values with the number keys and use the arrow keys to move within a field. When finished, press e. The confirmation dialog box appears. Press e. The WINS dialog box appears.
15