Page 31
Getting Started
1
Configuring the Serial Ports The serial port settings of the printer should match those of your PC or network controlling device. If the default settings do not match your configuration needs, you can use the menu panel to access the MAIN PORT or ALT PORT menus to change them. The printer serial port settings and the default values (*) are listed below. Parameter
Settings
Baud Rate
110, 300, 600, 1200, 2400, 4800, 9600*, 19200
Data Bits
7* or 8
Message Length
255*, 512
Parity
Odd, Even*, Mark, Space, Off
Stop Bits
1* or 2
Protocol
Standard*, XON/XOFF, XON/XOFF No Status, Multi-Drop, Polling Mode D
A faster communications configuration than the printer default is: 19200 baud, no parity, 8 data bits, 1 stop bit, and XON/XOFF No Status protocol. Note: You need to configure the printer serial port for 8 data bits if you want to print Code Page 850 or 8 bit ASCII character sets. Also, use XON/XOFF protocol for READY/BUSY buffer control. To configure the printer serial ports 1. From the OFFLINE READY display, press Menu and then press ↑ or ↓ until you reach the Install menu. 2. Press Select and then press ↑ or ↓ until the display shows: INSTALL MENU MAIN PORT or
INSTALL MENU ALT PORT
3. Press Select and then press ↑ or ↓ to scroll through the available commands. 4. Press Select when you reach the command you want to change. The current setting is shown with an asterisk (*). 5. Press ↑ or ↓ to scroll through the available settings for the command and then press Enter to activate the setting you want.
1-13
Page 32
4630 and 4830 Bar Code Label Printers User’s Manual
6. Do one of the following: •
Press Cont to return to the OFFLINE READY display.
•
Press Menu and repeat Steps 3 through 5 to change other serial port settings.
Note: You must cycle the printer power (turn off the printer, wait five seconds, and then turn on the printer) to have the changes you made take effect.
Verifying Printer Communications With Your System Once you have the printer connected to your system, you need to test for communications with your system. •
If you have connected the printer to a PC serial port, the easiest way to test communications is to run PrintSet and then print a test label. You can also send a character string to the printer from DOS.
•
If you have connected the printer to a PC parallel port, you can send a character string to the printer from DOS.
•
If you are using a different platform to communicate with your printer, please refer to your system user’s manual and Chapter 6, “Intermec Printer Language Commands,” in this manual for information on downloading commands to the printer.
To verify printer communications using DOS 1. Start with the printer display showing OFFLINE READY. You may need to press On line/Off line to see this display. 2. Press and release the menu panel access door to open the door. From the menu panel, press Menu and then press ↑ or ↓ until you reach the Service menu. 3. Press Select and then press ↑ or ↓ until the display shows: SERVICE MENU DATA LINE PRINT
4. Press Select and then press ↑ or ↓ until the display shows: DATA LINE PRINT ENABLED
5. Press Enter to enable Data Line Print mode. The printer is ready to print characters received from the host.
1-14
Page 33
Getting Started
1
6. Depending on the PC port the printer is connected to, type the following commands from the DOS prompt and press Enter after each line: Serial Port
Parallel Port
MODE COM1: 96,E,7,1
COPY CON LPT1
COPY CON COM1
ABCDEF^Z
ABCDEF^Z where: MODE COM1:
configures the PC serial port, COM1, for the communication values you specify. For example, 96,E,7,1 configures the PC serial port for 9600 baud, even parity, 7 data bits, and one stop bit. Note: The values you specify must match the values of the printer serial port.
COPY CON COM1 COPY CON LPT1 copies anything you type after this command to COM1 or to LPT1.
ABCDEF random characters typed at the host.
^Z (Ctrl-Z)
stops the COPY CON command and sends the information to the printer.
The printer prints each character it receives and the hexadecimal value for that character. 7. Press Cont on the printer menu panel to return to the OFFLINE READY display. Data Line Print mode is automatically disabled when you exit the Service menu. If this test does not work, check to make sure that the communication settings of the PC serial port match the settings of the printer serial port and that the printer cable is securely plugged into the serial or parallel port on the PC and the printer.
1-15
Page 34
Page 35
2 Operating and Configuring the Printer
Page 36
Page 37
Operating and Configuring the Printer
2
This chapter explains how to use the control and menu panels to operate your printer. It also contains information on how to change the printer configuration settings and how you can add options to your printer to enhance printer operation.
Using the Control Panel You can operate many features of the printer directly from the control panel instead of through a host computer. The control panel provides direct communications with the printer for tasks such as advancing media or canceling the current print job.
Reading the Display Operating messages These messages appear during normal operation of the printer. The example below is an operating message that indicates the printer is online and ready to print labels: ONLINE READY
Menu messages When you change printing adjustments, messages appear indicating the selections that are active and the task you are performing. For example, when you are adjusting the darkness of your labels, a message similar to the one shown below appears: DARK ADJUST 5*
An asterisk (*) appears next to the current setting. Error messages Error messages indicate a problem with the printer or the data from the host. The message below indicates the supply of thermal transfer ribbon is depleted or jammed: RIBBON FAULT
2-3
Page 38
4630 and 4830 Bar Code Label Printers User’s Manual
Using the Control Panel Keys The three control panel keys perform the following functions: On line/Off line Toggles the printer between online and offline. When online, the printer prints any data it receives. When offline, the printer stops printing and cannot accept data (but can accept protocol commands) from the host computer. For most menu panel operations, the printer must be offline. Feed/Reload When the printer is offline, you can use this key to advance the media. Pressing this key once advances media to the next print point. Pressing this key twice feeds an entire label through the printer. Cancel Press this key to delete the current print job after the current label has finished printing. The printer starts the next print job immediately.
Understanding the Indicator Lights The control panel has three lights that indicate the current operating status of the printer. On line This light indicates the printer is online (it can receive data from the host computer). When the printer is online, you can only access Operator menu commands. Alert This light flashes for conditions that require your attention, such as an open paper path. A message describing the alert condition also appears on the control panel display. Power This light remains on as long as the printer is turned on and is receiving power.
2-4
Page 39
Operating and Configuring the Printer
2
Using the Menu Panel The menu panel is located below the control panel and behind the menu panel access door. Press and release the access door to open it. You use the menu panel keys to change printer parameters and to setup security levels. Select Selects menus and features, and returns to the last adjustment display after you have left the menus. This key also selects digits when changing numerical parameters. Enter Activates a selected option and starts a selected Test or Service function. Menu
Returns to the menu list.
Cont
Exits the menus.
4630U-09
↑ and ↓ Scrolls through menus and commands and increases or decreases command settings.
About the Printer Menus The printer has four menus. The following table will help you to locate the menu you want to use, based on the tasks you are performing with the printer. Menu
Description
User
Operator
Used for making fine adjustments to the darkness, print alignment, and cutoff point of your labels. This menu can be accessed when the printer is online or offline.
Operators using the printer daily.
Install
Select communication parameters and security levels and install printer options. The printer must be offline to access this menu.
Programmers, systems analysts, or other personnel who install and set up the printer
Service
Set and adjust operating features, calibrate printer sensors, and test current settings. The printer must be offline to access this menu.
Technicians or other personnel qualified to do repair and service.
Configuration
Change the operating parameters and activate or disable optional features. The printer must be offline to access this menu.
Programmers, systems analysts, or supervisors who program and set up printer commands and label formats.
2-5
Page 40
4630 and 4830 Bar Code Label Printers User’s Manual
Operator and Install Menus Default values are indicated by an asterisk (*). OPERATOR MENU
INSTALL MENU
2-6
DARK ADJUST
-10 to 10, 0*
X FORMS ADJUST
-30 to 30, 0*
Y FORMS ADJUST
-30 to 30, 0*
LABEL REST POINT
-30 to 30, 0*
MAIN PORT
BAUD RATE
19200 9600* 4800 2400 1200 600 300 110
DATA BITS
7* 8
MESSAGE LENGTH
255* 512
PARITY
ODD EVEN* MARK SPACE OFF
STOP BITS
1* 2
PROTOCOL
STANDARD* XON/XOFF XONXOFF NO STAT MULTIDROP POLLING MODE D COAX/TWINAX
DEVICE ADDRESS
A* to Z, 0 to 5
ALT PORT
Same selections as MAIN PORT.
MAX PRINT SPEED
2.0 to 8.0* INCH/SECOND (51 to 203* mm/SECOND) 4630 2.0 to 5.0* INCH/SECOND (51 to 127* mm/SECOND) 4830
SECURITY
LEVEL 0* LEVEL 3 LEVEL 2 LEVEL 1