The text of a manual · part 14 of 26
User's Manual: 4630 and 4830 Bar Code Printers, pages 131 to 140
Pages 131 to 140 of 252
The original document is the PDF (1.6 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 4830
Page 131
Intermec Printer Language Commands
Programming Commands
6 Page #
A
Format, Create/Edit
6-57
E
Format, Erase
6-57
F
Format, Create/Edit
6-57
G
User-Defined Character, Clear/Create
6-64
J
Outline User-Defined Font, Download
6-63
N
Current Edit Session, Save
6-54
R
Program Mode, Exit
6-64
S
Page, Create/Edit
6-63 s
Page, Delete
6-63
T
Bitmap User-Defined Font, Clear/Create
6-52
UDC Editing Commands u
Graphic or UDC, Define
6-59 x
Bitmap Cell Width for Graphic or UDF, Define
6-51 y
Bitmap Cell Height for Graphic or UDF, Define
6-51
UDC Field Editing Commands c
Graphic Type, Select
6-59 f
Field Direction, Define
6-55 h
Height Magnification, Define
6-59 o
Field Origin, Define
6-56 w
Width Magnification, Define
6-65
6-15
Page 132
4630 and 4830 Bar Code Label Printers User's Manual
Print Mode Commands Configuration Commands
Page #
<SI>A
Control Panel Access Permission, Set
6-31
<SI>c
Cutter, Enable/Disable*
6-31
<SI>D
End-of-Print Skip Distance, Set
6-32
<SI>d
Dark Adjust, Set
6-32
<SI>F
Top of Form, Set
6-36
<SI>f
Label Rest Point, Adjust
6-33
<SI>g
TTR/Direct Thermal Media Grade, Select
6-37
<SI>L
Maximum Label Length, Set*
6-34
<SI>l
Printer Language, Select
6-36
<SI>O
Online/Offline on Power Up*
6-35
<SI>R
Label Retract, Enable/Disable*
6-33
<SI>r
Label Retract Distance, Set
6-34
<SI>S
Print Speed, Set
6-35
<SI>T
Label Stock Type, Select*
6-34
<SI>t
Self-Strip, Enable/Disable*
6-36
D
Reset Memory to Default (Test and Service Command)
6-66
* After enabling these commands, you need to reset the printer or cycle its power. Print Commands
6-16
Page #
<ACK>
First Data Entry Field, Select
6-24
<CAN>
Clear All Data
6-22
<CR>
Next Data Entry Field, Select
6-26
<DEL>
Clear Data From Current Field
6-22
<ESC><SP>
Start/Stop Characters, Print
6-28
<ESC>D
Field Decrement, Set
6-24
<ESC>E
Format, Select
6-25
<ESC>F
Field, Select
6-23
<ESC>G
Page, Select
6-27
<ESC>I
Field Increment, Set
6-24
<ESC>N
Increment/Decrement, Disable
6-25
Page 133
Intermec Printer Language Commands
Print Commands
6 Page #
<ESC>P
Program Mode, Enter
6-27
<ESC>T
Test and Service Mode, Enter
6-28
<ETB>
6-27
<FF>
Form Feed
6-25
<FS>
Numeric Field Separator
6-26
<GS>
Alphanumeric Field Separator
6-21
<RS>
Quantity Count, Set
6-28
<SUB>
Data Shift - International Characters
6-23
<US>
Batch Count, Set
6-22
Protocol Modification Commands <EOT>
Postamble, Set
6-35
<ESC><SYN>
Message Delay, Set
6-34
<ESC>d
Autotransmit 2, Enable
6-30
<ESC>e
Autotransmit 3, Enable
6-31
<ESC>j
Autotransmit 1, Enable
6-30
<ESC>k
Autotransmit 1, 2, and 3, Disable
6-31
<SOH>
Preamble, Set
6-35
<SYN>
Intercharacter Delay, Set
6-33
C
Command Tables, Load
6-54
Test and Service Commands
Page #
D
Reset Memory to Default
6-66
G
Gap Sensor Value, Transmit
6-66
L
Label Path Open Sensor Value, Transmit
6-66
M
Mark Sensor Value, Transmit
6-66
P
Printhead Temperature Sensor Value, Transmit
6-66
Q
Quality Label, Print
6-66
R
Test and Service Mode, Exit
6-66
T
Label Taken Sensor Values, Transmit
6-66
6-17
Page 134
4630 and 4830 Bar Code Label Printers User's Manual
Transmit Commands <ESC>H
Printhead Parameters, Transmit
6-27
<ESC>L
Label and Gap Length, Transmit
6-19
<ESC>M
Program Number, Transmit
6-28
<ESC>m
Memory Usage, Transmit
6-26
<ESC>O
Options Selected, Transmit
6-26
<ESC>p
Configuration Parameters, Transmit
6-23
<ESC>Q
Remaining Quality and Batch Counts, Transmit
6-20
<ESC>u
User-Defined Characters, Transmit
6-28
<ESC>v
Font, Transmit
6-24
<ESC>x
Format, Transmit
6-25
<ESC>y
Page, Transmit
6-27
<ESC>Z
User-Defined Tables, Transmit
6-29
<BS>
Warm Boot
6-29
<SI>c
Cutter, Enable/Disable
6-31
<SI>R
Label Retract, Enable/Disable
6-33
<SI>r
Label Retract Distance, Set
6-34
<SO>
Cut
6-23
Cutter Commands
Self-Strip Commands
6-18
<BS>
Warm Boot
6-29
<SI>R
Label Retract, Enable/Disable
6-33
<SI>t
Self-Strip, Enable/Disable
6-36
Page 135
Immediate Commands
6
Immediate Commands The following command set is effective in any of the operational modes of the 4630 or 4830 printer. Use the commands in this set to query the printer for status and print job information. Unlike other commands that the printer stores in the data buffer and executes in the order received, the printer executes immediate commands when it receives them, regardless of printer mode.
Abort Print Job Purpose:
Stops batch printing.
Syntax:
<EM>
Notes:
The printer sets the remaining quantity and batch counts to 1. Other commands remaining in the buffer will continue to be executed.
Error Code, Request Purpose:
Solicits error codes from the printer.
Syntax:
<BEL>
Notes:
The most recent error code is sent back in the form of an ASCII number. The error code represents a command syntax error or a printer RAM usage error. If no errors have occurred since powering on the printer, the printer sends a zero.
Label and Gap Length, Transmit Purpose:
Transmits the label and gap length as measured by the number of 5 mil increments.
Syntax:
<ESC>L
Notes:
Label length refers to the length of the label currently being processed. If the label is longer than the distance between the label sensor and the printhead, the printer transmits the length of the previous label. If continuous stock is selected, the printer transmits the length defined by the <SI>L command (default is 1000). The gap length is 0.
6-19
Page 136
4630 and 4830 Bar Code Label Printers User's Manual
Remaining Quantity and Batch Counts, Transmit Purpose:
Uploads the remaining quantity and batch counts for the current print job.
Syntax:
<ESC>Q
Purpose:
Executes a printer power up reset immediately.
Syntax:
<DLE>
Notes:
All data and commands in the input buffer are erased.
Reset
Status Dump Purpose:
Causes the printer to upload all current printer status.
Syntax:
<VT> The printer status is uploaded in the following order (top to bottom, from left): <GS> <US> <US> <EM> <DC3>
Buffer already full Paper path open Ribbon fault No label stock Buffer now full
<BS> <FS> <DC1> <DC1> <DC1>
Takeup reel full Label at strip pin Skipping Printing Ready
Status Enquiry Purpose:
Transmits the current printer status to the host.
Syntax:
<ENQ>
Notes:
If more than one status is true, the printer transmits the status with the highest priority (top to bottom, from left): <GS> <US> <US> <EM> <DC3>
6-20
Buffer already full Paper path open Ribbon fault No label stock Buffer now full
<BS> <FS> <DC1> <DC1> <DC1>
Takeup reel full Label at strip pin Skipping Printing Ready
Page 137
Print Mode Commands
6
Print Mode Commands The printer must be in Print mode to • pass data to formats.
• print labels.
• change the printer configuration.
When you enter data into a format for printing, the printer uses a field pointer to designate the field in the format where the data should print. If a new format is chosen, the field pointer automatically points to the lowest numbered data entry field and will continue to point to that field unless a different field or format is selected. If a selected field already contains data, it will be overwritten by the new data. If the pointer is pointing to the same field that just accepted data, the new data will be concatenated to the previously entered data. You can send Print mode commands through the methods described in Chapter 5. The command string to enter Print mode from Program mode or Test and Service mode is: <STX>R<ETX>
Note: Each string of commands must be preceded by the start of message character <STX>, and followed by the end of message character <ETX>. All Print mode commands are terminated by the next command in the message. The command separator (<NUL> or <LF>) is optional between commands, but is necessary to separate commands from data. The following command descriptions explain the print commands that are effective when the printer is in Print mode. The commands are listed in alphabetical order according to the command description.
Alphanumeric Field Separator Purpose:
Marks regions of alphanumeric characters to increment or decrement.
Syntax:
<GS>
Example:
PART <GS>001<GS> 001 <GS> the region to be incremented. marks the region and does not appear on the label.
Alphanumeric characters are 0 to 9 and A to Z. The order of alphanumeric characters is: 0, 1, 2...7, 8, 9, A, B, C...X, Y, Z, 0, 1, 2...7, 8, 9, A, B, C...
6-21
Page 138
4630 and 4830 Bar Code Label Printers User's Manual
Notes:
You may have more than one region in a field as long as they do not overlap and they are incremented or decremented independent of each other. Increment and decrement regions cannot overlap. If there are any nonalphanumeric characters within this region, they are ignored.
Batch Count, Set Purpose:
Sets the number of labels to be printed in the next batch.
Syntax:
<US>n The range for n is from 1 to 9999.
Default: Notes:
n=1 An error code (21) is generated if n is out of range.
Clear All Data Purpose:
Clears all host-entered data from the current page or format.
Syntax:
<CAN>
Notes:
If no page is selected, the pointer indicates the first data entry field in the format after the data is cleared. If a page is selected, the pointer designates the first data entry field in the first format.
Clear Data From Current Field Purpose:
Deletes data from the current field.
Syntax:
<DEL>
Notes:
The field pointer continues to designate the current field even after the data is cleared.
Command Terminator 1 Purpose:
Terminates the current command.
Syntax:
<NUL>
Command Terminator 2
6-22
Purpose:
Terminates the current command.
Syntax:
<LF>
Page 139
Print Mode Commands
6
Configuration Parameters, Transmit Purpose:
Uploads the current configuration commands from the printer.
Syntax:
<ESC>p
Notes:
Only the configuration parameters that can be set from the host are received. Use this command to view, edit, or copy the current configuration command settings.
Cut Purpose:
Advances the label out to the cutter and cuts the label stock.
Syntax:
<SO>
Notes:
This command is only executed if the cutter is installed but not enabled.
Data Shift – International Characters Purpose:
Allows command characters to be entered as data.
Syntax:
<SUB>
Notes:
An error code is generated if no character follows this command.
Field, Select Purpose:
Selects a data field for entering or working with data.
Syntax:
<ESC>Fn or <ESC>F["name"] n can range from 0 to 199.
Default: Notes:
n=0 The parameter for this command may be either the field number or the field name. It cannot be both. If neither are present, the printer defaults to 0. If the field number is used, all following data is entered into field n. If the field name is used, all following data is entered into all fields with that name in the current format or page. The field name must be bracketed by quotation marks (" "). An error code (33) is generated if an invalid field number is entered.
6-23
Page 140
4630 and 4830 Bar Code Label Printers User's Manual
Field Decrement, Set Purpose:
Sets the field decrement value for the current field.
Syntax:
<ESC>Dn The range for n is from 1 to 9999. Field decrement values in data fields are decremented by n after each print.
Default: Notes:
n=1 An error code (22) is generated if the decrement value is out of range.
Field Increment, Set Purpose:
Sets the increment value for the selected field.
Syntax:
<ESC>In The range for n is from 1 to 9999. Field increment values in data entry fields are incremented by n after each print.
Default: Notes:
n=1 An error code is generated if the increment value is out of range.
First Data Entry Field, Select Purpose:
Sets the field pointer to the lowest numbered data entry field in that format.
Syntax:
<ACK>
Notes:
This command ensures that data will print in the field with the lowest number if you do not want to specify a data field by its field number.
Font, Transmit Purpose:
Uploads a font from the printer in the form of commands and data the printer receives to create the font.
Syntax:
<ESC>vn n is the font ID number and can range from 0 to 41.
6-24