The text of a manual · part 5 of 32
4400 Bar Code Label Printer User's Manual, pages 41 to 50
Pages 41 to 50 of 318
The original document is the PDF (2.3 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 4400
Page 41
HelvC NugFont
Co d e 39 Installing the Printer
2
4400-25B
Connecting the Printer to Your System The proper method for connecting your printer to the host computer is determined by the way your system is configured. This section contains procedures for point-to-point and non-switched modem installations. There is also a reference section for network installations. You can connect your 4400 printer to a PC, a local area network, an AS/400 (or other midrange), or a mainframe. This section provides the information necessary for connecting to any of these systems. The following illustration shows you where to connect your system to the printer. You can use either of these two ports on the rear of the printer: •
Serial communications port
•
Optional I/O board port (if you have an adapter card installed)
2-5
Page 42
4400 Bar Code Label Printer User’s Manual
Connecting the Printer
Optional I/O port Serial communication port connector
4400U.011
Connecting the 4400 to a PC You can connect the 4400 to either a serial port or parallel port (if you have the option installed) on your PC. You must provide the correct cables for connecting the printer. Refer to the following instructions for cable information. Contact your Intermec representative for ordering assistance if you do not have the appropriate cables.
Connecting the Printer to a PC Serial Port To connect the 4400 to your PC serial port, you need a shielded EIA RS-232, RS422, or RS-485 electrical interface with a 25-pin D-style subminiature connector. It must have pins on the printer end and an appropriate serial port connector on the other end. Use the following table to determine the correct Intermec cable for your application. Cable schematics for these cables appear on the next page.
2-6
For Connecting To
Use Intermec Cable Part Number
IBM PC AT
048693 (25-pin printer to 9-pin serial port straight-through)
IBM PC XT
048668 (25-pin printer to 25-pin serial port null modem)
Page 43
HelvC NugFont
2
Co d e 39 Installing the Printer
To connect your printer to a PC serial port 1. Turn the On/Off switch to the off position. 2. Plug the 25-pin connector into the serial communications port on the back of the 4400 printer. 3. Plug the other end of the cable into a serial COM port on the PC. 4. If necessary, change the PC serial port configuration to match your printer. The default configuration settings for the 4400 printer are: • • • • • •
9600 baud even parity 7 bit word length XON/XOFF no status response protocol device address A direct thermal media
See “Configuring the Serial Port” later in this chapter for more information.
RS-232 Null Modem Cable for AT (Part Number 048693) SHIELD 9-PIN (SOCKET) D-SUB METAL BACKSHELL
25-PIN (PLUG) D-SUB METAL BACKSHELL 1
CHASSIS GROUND
RECEIVED DATA
2
2
TRANSMITTED DATA
TRANSMITTED DATA
3
3
RECEIVED DATA
CLEAR TO SEND
8
8
CARRIER DETECT DATA SET READY
REQUEST TO SEND
7
DATA TERMINAL READY
4
6
DATA SET READY
6
20 DATA TERMINAL READY
CARRIER DETECT
1
5
CLEAR TO SEND
4
REQUEST TO SEND
5
7
GROUND
AT
PRINTER
GROUND
NOTE: The metal backshell is connected directly to the shield to achieve electrostatic discharge (ESD) immunity.
4400-19B
2-7
Page 44
4400 Bar Code Label Printer User’s Manual
RS-232 Null Modem Cable for PC (Part Number 048668) SHIELD 25-PIN (SOCKET) D-SUB METAL BACKSHELL
25-PIN (PLUG) D-SUB METAL BACKSHELL
CHASSIS GROUND
1
1
CHASSIS GROUND
TRANSMITTED DATA
2
3
RECEIVED DATA
RECEIVED DATA
3
2
TRANSMITTED DATA
REQUEST TO SEND
4 CARRIER DETECT
CLEAR TO SEND
5
8
DATA SET READY
6
20 DATA TERMINAL READY
GROUND
7
7
GROUND
DATA TERMINAL READY 20
6
DATA SET READY
CARRIER DETECT
4
8
5 PC
CLEAR TO SEND
PRINTER
NOTE: The metal backshell is connected directly to the shield to achieve electrostatic discharge (ESD) immunity.
3240G.022
Connecting the Printer to a PC Parallel Port If you are using a parallel port to communicate with the printer, you need: • a Centronics interface adapter installed in the printer.
• a parallel cable to run between the printer and the PC.
If you did not have the parallel interface installed at the factory, you can install the field installable option (Part No. 056830) in the optional I/O board port of your printer. You can purchase a parallel cable from Intermec (Part No. 051211) or from your local computer store. To connect your printer to a PC parallel port 1. Turn the On/Off switch to the off position. 2. Plug the Centronics cable connector into the interface adapter port on the back of the 4400 printer. 3. Plug the other end of the cable into a parallel port on the PC.
2-8
Page 45
HelvC NugFont
Co d e 39 Installing the Printer
2
Connecting the 4400 to a Network You can connect the 4400 printer to Novell NetWare networks, Token Ring networks, or TCP/IP networks. To connect the 4400 printer to a network, you must have: • a Centronics parallel interface installed in your printer.
• a network interface adapter (for example, Ethernet).
If you did not have the interface installed at the factory, you can install the field installable option (Part No. 056830) in the optional I/O board port of your printer. The network interface adapter (for example, Ethernet) connects to the Centronics parallel interface on the back of the printer. Your network must be able to use XON/XOFF (hardware handshake) protocol. Refer to your network documentation for more information.
Connecting the 4400 to an AS/400 To connect a 4400 printer directly to an AS/400 or midrange system, you need: • a twinax adapter card.
• a twinaxial cable (equivalent to IBM Part No. 7362267 or 7362062). The maximum cable length for the twinax interface is 5000 feet (1525 meters).
If you did not have the twinax card installed at the factory, you can install the field installable option (Part No. 056835) in the optional I/O board port of your printer. For help on cabling and communications, see the manual that comes with the twinax adapter card. Note: If you are using a midrange computer other than the AS/400, refer to your system documentation for information on cabling and setting up communications.
Connecting the 4400 to a Mainframe To connect a 4400 printer directly to an IBM mainframe, you need: • a coax adapter card.
• a coaxial cable (equivalent to IBM Part No. 2577672 or 1833108).
The maximum cable length allowed is 4920 feet (1500 meters). See the IBM specification Installation and Assembly of Coaxial Cable and Accessories, part number GA27-2805-4, for further information.
2-9
Page 46
4400 Bar Code Label Printer User’s Manual
If you did not have the coax card installed at the factory, you can install the field installable option (Part No. 056836) in the optional I/O board port of your printer. For help on cabling and communications, see the manual that comes with your coax adapter card.
RS-422 Intermec Pin Assignments SHIELD 1
Input RxDA 16
Output TxDA 14 Output TxDB 19
+ -
➤ ➤
Input RxDB 13
1
-
➤ ➤
+
NOTE: Connect pin 1 to shield at one end only.
19 14
16 13
PRINTER
HOST 4400-17B
Note: The host in this case includes Intermec products that support RS-422. NonIntermec controllers may have different pin assignments.
Straight Through DTE to DCE Cable for Use With a Modem SHIELD
25-PIN (PLUG) D-SUB METAL BACKSHELL
25-PIN (PLUG) D-SUB METAL BACKSHELL CHASSIS GROUND
1
TRANSMITTED DATA
2
1
RECEIVED DATA
3
REQUEST TO SEND
4
CLEAR TO SEND
5
DATA TERMINAL READY
20
SIGNAL GROUND
7
7
PRINTER
MODEM
➤ ➤ ➤ ➤ ➤
CHASSIS GROUND
2
TRANSMITTED DATA
3
RECEIVED DATA
4
REQUEST TO SEND
5
CLEAR TO SEND
20 DATA TERMINAL READY SIGNAL GROUND
NOTE: The metal backshell is connected directly to the shield to achieve electrostatic discharge (ESD) immunity. 4400-22B
2-10
Page 47
HelvC NugFont
Co d e 39 Installing the Printer
2
RS-485 (Multi-Drop) Cables Refer to the following manuals for information on Multi-Drop cabling and connections. •
9154 Multi-Drop Line Controller System Manual (Part No. 048517)
•
9161B Installation Manual (Part No. 049572)
Cabling Considerations in Noisy Electrical Environments The items listed below create noisy electrical environments that can disrupt data communications between your host computer and the printer: •
Large power transformers
•
Large electric motors
•
Arc welders
•
Motor controllers
•
Switch gears
Following are several suggestions for reducing the effects of electrical noise if any of the items listed above are located near the printer. Some experimentation may be required to eliminate the problems. If you need help, ask your Intermec representative for assistance. •
Always use shielded cable. Connect the cable shield to the metal backshells on the cable connectors and fasten the connectors to the serial ports using screws.
•
Install ferrite cable clamps.
•
Connect the printer chassis ground to the building ground. The chassis ground is located on the ground pin of the printer power cord.
2-11
Page 48
4400 Bar Code Label Printer User’s Manual
Configuring the Serial Port The printer’s main port settings should match those of your host computer or controlling device. If the default settings are not satisfactory for your needs, follow the instructions below to change them. The choices for the main port settings are summarized below. The default values are shown in bold. Command
Settings
Description
Baud Rate
110, 300, 600, 1200, 2400, 4800, 9600, 19200
The rate (in bits per second) at which the host exchanges data with the printer.
Data Bits
7 or 8
The number of bits that represent the ASCII characters.
Message Length
255, 512
Determines the maximum number of characters in a block (including overhead) that is sent to the printer in Standard, Polling Mode D and MultiDrop protocols.
Parity
Odd, Even, Mark, Space, Off
Checks each transmitted character for errors.
Stop Bits
1 or 2
Bits that follow each character to synchronize character transmission.
Protocol
Standard, XON/XOFF*,
The type of network used to connect the printer, Multi-Drop, Polling Mode D host and the rest of the data collection system.
Device Address
A to Z, or 0 to 5
Unique address for each device connected with Multi-Drop protocol.
*Use for READY/BUSY buffer control.
2-12
Page 49
HelvC NugFont
Co d e 39 Installing the Printer
2
To change the main port settings, you must use the control panel to reach the selections in the main port menu. To change any of the values listed in the previous table 1. Start at the OFFLINE READY display. 2. Press [MENU]. Then press [↑] or [↓] until the display shows the following: OFFLINE INSTALL MENU
3. Press [SELECT]. The display shows: INSTALL MENU SECURITY
4. Press [↑] or [↓] until the display shows the following: INSTALL MENU MAIN PORT
5. Press [SELECT]. The display shows the following: MAIN PORT BAUD RATE
6. Press [↑] or [↓] to scroll through the available commands. 7. Press [SELECT] when you reach the command you want to change. The display shows the current setting with an asterisk (*). 8. Press [↑] or [↓] to scroll through the available settings for the command. 9. When you see the setting you want, press [ENTER]. The asterisk (*) appears next to the new setting, indicating it is now active. 10. Press [CONTINUE] to return to the OFFLINE READY display or, to change other settings, press [MENU] and repeat Steps 6 through 9. Note: You must cycle the printer power (turn the printer off and then on again) to put any changes into effect. Cycling the power after making a number of changes activates all of them at once.
2-13
Page 50
4400 Bar Code Label Printer User’s Manual
Verifying Printer Communications With Your System Once you have the printer connected to your system, you need to verify that the printer communicates with your system. This feature is available through the Data Line Print command in the Service menu. You have two selections for Data Line Print: Enabled The printer prints all ASCII characters it receives from the host, including control characters. The corresponding hexadecimal code is printed underneath each character. Disabled
The printer prints normally. This is the default setting.
To enable or disable Data Line Print 1. Start at the OFFLINE READY display. 2. Press [MENU] to enter the main menu. Press [↑] or [↓] until you reach the Service menu. 3. Press [SELECT] to enter the Service menu. Press [↑] or [↓] until the display shows: SERVICE MENU DATA LINE PRINT
4. Press [SELECT]. The display shows: DATA LINE PRINT DISABLED*
5. Press [↑] or [↓] to change to Enabled, and then press [ENTER] to move the asterisk next to the new selection. The display shows: DATA LINE PRINT ENABLED*
The printer will now print characters received from the host. The data line print automatically returns to DISABLED after you exit this menu. Press [ONLINE/OFFLINE] to return to normal printing. Note: An example using DOS to verify printer communications follows this procedure.
2-14