Page 41

HelvC NugFont

Co d e 39 Installing the Printer

2

4400-25B

Connecting the Printer to Your System The proper method for connecting your printer to the host computer is determined by the way your system is configured. This section contains procedures for point-to-point and non-switched modem installations. There is also a reference section for network installations. You can connect your 4400 printer to a PC, a local area network, an AS/400 (or other midrange), or a mainframe. This section provides the information necessary for connecting to any of these systems. The following illustration shows you where to connect your system to the printer. You can use either of these two ports on the rear of the printer: •

Serial communications port

•

Optional I/O board port (if you have an adapter card installed)

2-5

Page 42

4400 Bar Code Label Printer User’s Manual

Connecting the Printer

Optional I/O port Serial communication port connector

4400U.011

Connecting the 4400 to a PC You can connect the 4400 to either a serial port or parallel port (if you have the option installed) on your PC. You must provide the correct cables for connecting the printer. Refer to the following instructions for cable information. Contact your Intermec representative for ordering assistance if you do not have the appropriate cables.

Connecting the Printer to a PC Serial Port To connect the 4400 to your PC serial port, you need a shielded EIA RS-232, RS422, or RS-485 electrical interface with a 25-pin D-style subminiature connector. It must have pins on the printer end and an appropriate serial port connector on the other end. Use the following table to determine the correct Intermec cable for your application. Cable schematics for these cables appear on the next page.

2-6

For Connecting To

Use Intermec Cable Part Number

IBM PC AT

048693 (25-pin printer to 9-pin serial port straight-through)

IBM PC XT

048668 (25-pin printer to 25-pin serial port null modem)

Page 43

HelvC NugFont

2

Co d e 39 Installing the Printer

To connect your printer to a PC serial port 1. Turn the On/Off switch to the off position. 2. Plug the 25-pin connector into the serial communications port on the back of the 4400 printer. 3. Plug the other end of the cable into a serial COM port on the PC. 4. If necessary, change the PC serial port configuration to match your printer. The default configuration settings for the 4400 printer are: • • • • • •

9600 baud even parity 7 bit word length XON/XOFF no status response protocol device address A direct thermal media

See “Configuring the Serial Port” later in this chapter for more information.

RS-232 Null Modem Cable for AT (Part Number 048693) SHIELD 9-PIN (SOCKET) D-SUB METAL BACKSHELL

25-PIN (PLUG) D-SUB METAL BACKSHELL 1

CHASSIS GROUND

RECEIVED DATA

2

2

TRANSMITTED DATA

TRANSMITTED DATA

3

3

RECEIVED DATA

CLEAR TO SEND

8

8

CARRIER DETECT DATA SET READY

REQUEST TO SEND

7

DATA TERMINAL READY

4

6

DATA SET READY

6

20 DATA TERMINAL READY

CARRIER DETECT

1

5

CLEAR TO SEND

4

REQUEST TO SEND

5

7

GROUND

AT

PRINTER

GROUND

NOTE: The metal backshell is connected directly to the shield to achieve electrostatic discharge (ESD) immunity.

4400-19B

2-7

Page 44

4400 Bar Code Label Printer User’s Manual

RS-232 Null Modem Cable for PC (Part Number 048668) SHIELD 25-PIN (SOCKET) D-SUB METAL BACKSHELL

25-PIN (PLUG) D-SUB METAL BACKSHELL

CHASSIS GROUND

1

1

CHASSIS GROUND

TRANSMITTED DATA

2

3

RECEIVED DATA

RECEIVED DATA

3

2

TRANSMITTED DATA

REQUEST TO SEND

4 CARRIER DETECT

CLEAR TO SEND

5

8

DATA SET READY

6

20 DATA TERMINAL READY

GROUND

7

7

GROUND

DATA TERMINAL READY 20

6

DATA SET READY

CARRIER DETECT

4

8

5 PC

CLEAR TO SEND

PRINTER

NOTE: The metal backshell is connected directly to the shield to achieve electrostatic discharge (ESD) immunity.

3240G.022

Connecting the Printer to a PC Parallel Port If you are using a parallel port to communicate with the printer, you need: • a Centronics interface adapter installed in the printer.

• a parallel cable to run between the printer and the PC.

If you did not have the parallel interface installed at the factory, you can install the field installable option (Part No. 056830) in the optional I/O board port of your printer. You can purchase a parallel cable from Intermec (Part No. 051211) or from your local computer store. To connect your printer to a PC parallel port 1. Turn the On/Off switch to the off position. 2. Plug the Centronics cable connector into the interface adapter port on the back of the 4400 printer. 3. Plug the other end of the cable into a parallel port on the PC.

2-8

Page 45

HelvC NugFont

Co d e 39 Installing the Printer

2

Connecting the 4400 to a Network You can connect the 4400 printer to Novell NetWare networks, Token Ring networks, or TCP/IP networks. To connect the 4400 printer to a network, you must have: • a Centronics parallel interface installed in your printer.

• a network interface adapter (for example, Ethernet).

If you did not have the interface installed at the factory, you can install the field installable option (Part No. 056830) in the optional I/O board port of your printer. The network interface adapter (for example, Ethernet) connects to the Centronics parallel interface on the back of the printer. Your network must be able to use XON/XOFF (hardware handshake) protocol. Refer to your network documentation for more information.

Connecting the 4400 to an AS/400 To connect a 4400 printer directly to an AS/400 or midrange system, you need: • a twinax adapter card.

• a twinaxial cable (equivalent to IBM Part No. 7362267 or 7362062). The maximum cable length for the twinax interface is 5000 feet (1525 meters).

If you did not have the twinax card installed at the factory, you can install the field installable option (Part No. 056835) in the optional I/O board port of your printer. For help on cabling and communications, see the manual that comes with the twinax adapter card. Note: If you are using a midrange computer other than the AS/400, refer to your system documentation for information on cabling and setting up communications.

Connecting the 4400 to a Mainframe To connect a 4400 printer directly to an IBM mainframe, you need: • a coax adapter card.

• a coaxial cable (equivalent to IBM Part No. 2577672 or 1833108).

The maximum cable length allowed is 4920 feet (1500 meters). See the IBM specification Installation and Assembly of Coaxial Cable and Accessories, part number GA27-2805-4, for further information.

2-9

Page 46

4400 Bar Code Label Printer User’s Manual

If you did not have the coax card installed at the factory, you can install the field installable option (Part No. 056836) in the optional I/O board port of your printer. For help on cabling and communications, see the manual that comes with your coax adapter card.

RS-422 Intermec Pin Assignments SHIELD 1

Input RxDA 16

Output TxDA 14 Output TxDB 19

+ -

➤ ➤

Input RxDB 13

1

-

➤ ➤

+

NOTE: Connect pin 1 to shield at one end only.

19 14

16 13

PRINTER

HOST 4400-17B

Note: The host in this case includes Intermec products that support RS-422. NonIntermec controllers may have different pin assignments.

Straight Through DTE to DCE Cable for Use With a Modem SHIELD

25-PIN (PLUG) D-SUB METAL BACKSHELL

25-PIN (PLUG) D-SUB METAL BACKSHELL CHASSIS GROUND

1

TRANSMITTED DATA

2

1

RECEIVED DATA

3

REQUEST TO SEND

4

CLEAR TO SEND

5

DATA TERMINAL READY

20

SIGNAL GROUND

7

7

PRINTER

MODEM

➤ ➤ ➤ ➤ ➤

CHASSIS GROUND

2

TRANSMITTED DATA

3

RECEIVED DATA

4

REQUEST TO SEND

5

CLEAR TO SEND

20 DATA TERMINAL READY SIGNAL GROUND

NOTE: The metal backshell is connected directly to the shield to achieve electrostatic discharge (ESD) immunity. 4400-22B

2-10

Page 47

HelvC NugFont

Co d e 39 Installing the Printer

2

RS-485 (Multi-Drop) Cables Refer to the following manuals for information on Multi-Drop cabling and connections. •

9154 Multi-Drop Line Controller System Manual (Part No. 048517)

•

9161B Installation Manual (Part No. 049572)

Cabling Considerations in Noisy Electrical Environments The items listed below create noisy electrical environments that can disrupt data communications between your host computer and the printer: •

Large power transformers

•

Large electric motors

•

Arc welders

•

Motor controllers

•

Switch gears

Following are several suggestions for reducing the effects of electrical noise if any of the items listed above are located near the printer. Some experimentation may be required to eliminate the problems. If you need help, ask your Intermec representative for assistance. •

Always use shielded cable. Connect the cable shield to the metal backshells on the cable connectors and fasten the connectors to the serial ports using screws.

•

Install ferrite cable clamps.

•

Connect the printer chassis ground to the building ground. The chassis ground is located on the ground pin of the printer power cord.

2-11

Page 48

4400 Bar Code Label Printer User’s Manual

Configuring the Serial Port The printer’s main port settings should match those of your host computer or controlling device. If the default settings are not satisfactory for your needs, follow the instructions below to change them. The choices for the main port settings are summarized below. The default values are shown in bold. Command

Settings

Description

Baud Rate

110, 300, 600, 1200, 2400, 4800, 9600, 19200

The rate (in bits per second) at which the host exchanges data with the printer.

Data Bits

7 or 8

The number of bits that represent the ASCII characters.

Message Length

255, 512

Determines the maximum number of characters in a block (including overhead) that is sent to the printer in Standard, Polling Mode D and MultiDrop protocols.

Parity

Odd, Even, Mark, Space, Off

Checks each transmitted character for errors.

Stop Bits

1 or 2

Bits that follow each character to synchronize character transmission.

Protocol

Standard, XON/XOFF*,

The type of network used to connect the printer, Multi-Drop, Polling Mode D host and the rest of the data collection system.

Device Address

A to Z, or 0 to 5

Unique address for each device connected with Multi-Drop protocol.

*Use for READY/BUSY buffer control.

2-12

Page 49

HelvC NugFont

Co d e 39 Installing the Printer

2

To change the main port settings, you must use the control panel to reach the selections in the main port menu. To change any of the values listed in the previous table 1. Start at the OFFLINE READY display. 2. Press [MENU]. Then press [↑] or [↓] until the display shows the following: OFFLINE INSTALL MENU

3. Press [SELECT]. The display shows: INSTALL MENU SECURITY

4. Press [↑] or [↓] until the display shows the following: INSTALL MENU MAIN PORT

5. Press [SELECT]. The display shows the following: MAIN PORT BAUD RATE

6. Press [↑] or [↓] to scroll through the available commands. 7. Press [SELECT] when you reach the command you want to change. The display shows the current setting with an asterisk (*). 8. Press [↑] or [↓] to scroll through the available settings for the command. 9. When you see the setting you want, press [ENTER]. The asterisk (*) appears next to the new setting, indicating it is now active. 10. Press [CONTINUE] to return to the OFFLINE READY display or, to change other settings, press [MENU] and repeat Steps 6 through 9. Note: You must cycle the printer power (turn the printer off and then on again) to put any changes into effect. Cycling the power after making a number of changes activates all of them at once.

2-13

Page 50

4400 Bar Code Label Printer User’s Manual

Verifying Printer Communications With Your System Once you have the printer connected to your system, you need to verify that the printer communicates with your system. This feature is available through the Data Line Print command in the Service menu. You have two selections for Data Line Print: Enabled The printer prints all ASCII characters it receives from the host, including control characters. The corresponding hexadecimal code is printed underneath each character. Disabled

The printer prints normally. This is the default setting.

To enable or disable Data Line Print 1. Start at the OFFLINE READY display. 2. Press [MENU] to enter the main menu. Press [↑] or [↓] until you reach the Service menu. 3. Press [SELECT] to enter the Service menu. Press [↑] or [↓] until the display shows: SERVICE MENU DATA LINE PRINT

4. Press [SELECT]. The display shows: DATA LINE PRINT DISABLED*

5. Press [↑] or [↓] to change to Enabled, and then press [ENTER] to move the asterisk next to the new selection. The display shows: DATA LINE PRINT ENABLED*

The printer will now print characters received from the host. The data line print automatically returns to DISABLED after you exit this menu. Press [ONLINE/OFFLINE] to return to normal printing. Note: An example using DOS to verify printer communications follows this procedure.

2-14