Page 271
HelvC NugFont
Co d e 39 Routine Maintenance
10
®
44
00
SE
LE
CT
AL ER T
MEN
EN
U
TE
R
0P
EN
PO WE R
CO NT INUE
FE
ED
RE
LO
AD
ON
LIN E
ON LINE OF F LI NE
4400-66B
Replacing the Fuse If the Power light does not come on when you turn on the printer, you need to replace the main power fuse. You need the following items: •
Fuse for 5A, 250V, Slo-Blo fuse, (either 3AG or 5x20mm)
•
Medium, straight slot screwdriver
Warning Always disconnect the power cord before replacing the fuse. Failure to disconnect the power cord may result in injury or death due to electric shock. Avertissement Débranchez toujours le cordon d'alimentation avant de remplacer la fusible. Si vous ne débranchez pas de cordon d'alimentation, vous courrez le risque de blessure ou de mort par électrocution.
To replace the fuse 1. Turn off and unplug the printer. 2. With the screwdriver, turn the fuse holder a 1/2 turn counterclockwise. 3. The spring-loaded fuse holder will pop out. Remove the fuse holder.
10-11
Page 272
4400 Bar Code Label Printer User’s Manual
4. Remove the old fuse from the holder. 5. Install the new fuse into the holder. 6. With the screwdriver, press the fuse holder into place and turn it half a turn clockwise or until it stops. 7. Install the power cord. 8. Turn on the printer. If it still does not receive power, contact your Intermec representative.
4400-67
10-12
Page 273
A Appendix
Page 274
Page 275
Appendix
A
4400 Printer Specifications The specifications for the 4400 printer are as follows. The 4400 Maintenance Manual has details on printer performance and upkeep. Chapters 9 and 10 of this manual contain troubleshooting and maintenance procedures for everyday use.
Dimensions (no options installed) Height
13.0 inches (33.0 cm)
Width
12.0 inches (30.5 cm) with roll supply
Weight
35.0 pounds (15.9 kg)
Length
21.5 inches (54.6 cm)
Electrical Requirements Input Voltage
90 to 264 VAC
Frequency
48 to 62 Hz
Fuse
115 or 230 VAC
The printer has an auto-ranging power supply that automatically adjusts itself to the line voltages within the range shown above when it is plugged in.
Power Usage Typical usage
300 Watts
Typical usage is based on the amount of power required to print one label. This usage holds true for low line of 90 VAC to high line of 140 VAC. The typical usage of 300 Watts also applies to European power supplies.
Printing Method The 4400 is capable of direct thermal (DT) printing, or thermal transfer (TTR) printing using thermal transfer ribbon (TTR).
Printing Speed Maximum
4400: 10 inches (254 mm) per second 4400 w/6.5 mil printhead: 8.5 inches (221 mm) per second
Minimum
4400: 2.5 inches (64 mm) per second 4400 w/6.5 mil printhead: 3.0 inches (76 mm) per second
A-3
Page 276
4400 Bar Code Label Printer User’s Manual
Printhead Element
4400: 0.00492 inch (0.125 mm) 4400 w/6.5 mil printhead: 0.006575 inch (0.167 mm)
Width
4.4 inches (112 mm) maximum
Length
0.24 inch (6 mm) minimum, maximum is unlimited
Resolution
4400: 203 dpi (8 dots per mm) 4400 w/6.5 mil printhead: 152 dpi (6 dots per mm)
“X” dimensions:
4400: 10 mil to 50 mil (0.25 mm to 1.27 mm); 5 mil (0.13 mm) in drag mode only 4400 w/6.5 mil printhead: 6.5 mil, or 0.165 mm, for all modes
Media Specifications Roll
6,000 inches (152 m) maximum length 8.38 in (213 mm) maximum diameter
Core Size
3 inches (77 mm)
Label Length
0.24 inch (6 mm) to 24 inches (610 mm); fanfold, 19 inches (483 mm) maximum
Label Width
2.5 inches (64 mm) to 5.1 inches (132 mm)
Thickness
0.003 inch (0.08 mm) to 0.010 inch (90.25 mm)
Ribbon Specifications Roll
18,000 inches (457 m)
Widths
2.5 inches (64 mm) 3.5 inches (91 mm) 4.5 inches (114 mm)
Environment
A-4
Operating
32°F to 104°F (0°C to 40°C)
Storage
-4°F to 152°F (-20°C to 70°C)
Humidity
10% to 95% relative humidity
Page 277
Appendix
A
Communications Asynchronous RS-232C, RS-422, RS-485 interfaces Serial ASCII code Hardware (Ready/Busy) Flow Control Software (XON/XOFF) Flow Control Intermec Standard Block Protocol Polling Mode D Protocol Multi-Drop Protocol Baud Rates: 110, 300, 600, 1200, 2400, 4800, 9600, 19200
Fonts and Graphics Nine resident bitmap fonts (including OCR A and B), plus one resident smooth outline font, scaleable up to 3 inches. Fonts installed with PrintSet. 200 dpi graphics resolution
Character Sets US ASCII UK ASCII German Norwegian/Danish Swedish/Finnish Italian French Spanish Swiss 7-bit and 8-bit ISO Character Sets
A-5
Page 278
4400 Bar Code Label Printer User’s Manual
Bar Code Symbologies This section lists and describes the available bar code symbologies.
Code 39 Code 39 is the first alphanumeric symbology ever developed and is the standard non-retail bar code. It is a discrete, self-checking symbology of variable length and is used mostly by the automobile and medical industries. Intermec printer support 3 different types of Code 39: 43 character Code 39, full ASCII Code 39, and the 8646 compatible Code 39. The 8646 compatible version only differs from the full ASCII version by four characters. The “$,” “%,” “/,” and “+” are encoded as single characters instead of as “/D,” “/E,” “/O,” and “/K.” The 8646 compatible version allows the 4400 printer to be backward compatible with 86XX printers. If you enter <ESC><SPACE> as data, the start and stop characters are printed.
Code 93 Introduced in 1983, Code 93 was specially designed to complement Code 39. With the correct reading equipment, the two alphanumeric codes may be interchanged throughout a system without making any changes to software.
Code 2 of 5 Code 2 of 5 is a straightforward numeric symbology developed in the late 1960s. It has been used for warehouse sorting systems, photofinishing envelope identification, and for tracking sequentially numbered airline tickets. All information is contained in the width of the bars; the spaces do not contain information.
Interleaved 2 of 5 Interleaved 2 of 5 is a high density, self-checking, continuous numeric symbology, which has mainly been used in the distribution industry. Interleaved 2 of 5 actually encodes two digits, one in the bars and one in the spaces. A zero is added to character strings that are odd in length.
Codabar Originally developed in 1972, Codabar is a numeric symbology most commonly used in libraries, blood banks, and air parcel express applications.
A-6
Page 279
Appendix
A
Valid start/stop characters range from “A” to “D” and from “a” to “d.” They can be defined as part of the bar code field or downloaded as part of the print data. Start/stop characters sent down with printer data override the characters defined by the bar code field.
Code 11 Code 11 was developed in early 1977 to satisfy requirements for a very high density, discrete numeric bar code. The most extensive application of Code 11 has been for labeling telecommunications equipment.
Code 128 Code 128 was introduced in 1981 as a very high density, alphanumeric symbology. It is a variable length, continuous code that employs multiple element widths. In 86XX emulation mode, the Function 1 character is printed by entering <SUB> 1. In Advanced mode, the Function 1 character is printed by entering <SUB><SUB> 1. The characters for Function 2, 3, and 4 are represented in the same way. UCC-128 serial shipping container code automatically starts with subset C and <FNC1>. It is a fixed length version of Code 128 allowing up to 19 numeric characters to be entered. The first two characters are forced to zeros, and the MOD 10 check digit is calculated and inserted before the standard Code 128 digit.
UPC Universal Product Code (UPC) is a subset of EAN. It is a fixed length, numeric, continuous symbology employing four element widths. Two common types of UPC are Version A, which encodes 12 digits, and Version E, which encodes 6 digits. UPC has been used in the supermarket industry since 1973. UPC supplemental code is intended for only periodical issue numbers.
EAN The European Article Numbering system (abbreviated as EAN) is a numeric superset of UPC. EAN has both a version that uses 8 digits and a version that uses 13 digits. The version with 13 digits encodes the same number of bars as 12 digit UPC Version A, but the 13th digit is encoded into a parity pattern at the left of the center guard bar.
A-7
Page 280
4400 Bar Code Label Printer User’s Manual
The variable length option selects the UPC/EAN version by the number of characters in the data field. The number of data characters and check characters allowed for each version are: EAN 8 check character
7 data + 1
EAN 13 check character
12 data + 1
UPC version A check character
11 data + 1
UPC version E check character
6 data + 1
UPC version D1 check character
13 data + 1
UPC version D2 check characters
18 data + 2
UPC version D3 check characters
22 data + 2
UPC version D4 check characters
25 data + 3
UPC version D5 check characters
29 data + 3
A period (“.”) is used to delimit the bar code data from the supplemental data. Data to the right of the “.” is supplemental data; data to the left is bar code data. The two or five digit supplemental can be added to any version of the UPC/EAN code. The flag 1 option only applies to EAN 8, EAN 13, and UPC version A. For EAN 13, enabling the flag 1 option prints the first character of the bar code interpretive. For EAN 8 and UPC version A, enabling the flag 1 option moves the first and last character of the bar code interpretive outside of the guard bars.
POSTNET The Postal Numeric Encoding Technique (POSTNET) uses binary digits, represented as full bars and half bars, to provide a numeric bar code symbology that is easily read and decoded by optical reading systems. POSTNET provides both error detection and correction capabilities.
A-8