Page 151

HelvC NugFont

7

Co d e 39 Printer Commands

Configuration Commands (continued) Command Code

Function

Factory Default

8636/46 Emulation

<SI>i

IBM Language Translation, Enable or Disable

0 yes

<SI>l

Printer Language, Select

0 yes

<SI>r

Label Retract Distance, Set

284 yes

<SI>t

Self-Strip, Enable or Disable

0 yes

<SOH>

Preamble, Set

NUL yes

<SYN>

Intercharacter Delay, Set

0 yes

7-7

Page 152

4400 Bar Code Label Printer User’s Manual

Summary of Program Mode CommandsThe following table lists a summary of available Program mode commands. Each command is described in detail later in this chapter. Command Code

Function

Factory Default

8636/46 Emulation

Control Codes <BEL>

Transmit Error Code yes

<DLE>

Reset yes

<ENQ>

Status Enquiry yes

A

Format, Create or Edit yes

B

Bar Code Field, Create or Edit

C

Load Command Tables

D

Delete Field

E

Erase Format yes

F

Format, Create or Edit yes

G

User-Defined Character, Clear or Create yes

H

Human-Readable Field, Create or Edit

I

Interpretive Field, Edit yes

J

Outline User-Defined Font, Clear or Create no

L

Line Field, Create or Edit

M

Format Position in a Page, Assign no

N

Save Current Edit Session yes

O

Format Offset Within a Page, Define

R

Program Mode, Exit yes

S

Page, Create or Edit no

T

Bitmap User-Defined Font, Clear or Define yes

U

User-Defined Character Field, Create or Edit

Uppercase

7-8

0 yes yes

0

0

0

0,0

0 yes yes yes no yes

Page 153

HelvC NugFont

Co d e 39 Printer Commands

7

Program Mode Commands (continued) Command Code

Function

Factory Default

8636/46 Emulation

W

Box Field, Create or Edit

0 yes

X

Character Origin Offset, Define

0 yes

Z

Font Character Width, Define yes

Lowercase b

Border Around Human-Readable Text, Define

0 yes c

Type of Graphic, Font or Bar Code, Select

0 yes d

Field Data, Define Source yes e

Data Source for Format in a Page, Define no f

Field Direction, Define

0 yes g

Pitch Size, Set

12 no h

Height Magnification, Define i

Interpretive Field, Enable or Disable j

Outline Font Description, Download no k

Point Size, Set no l

Length of Line or Box Field, Define

100 yes m

Format Position from Page, Delete a no o

Field Origin, Define

0,0 yes p

Code 39 Prefix Character, Define q

Format Direction in a Page, Define

0 no r

Character Rotation or Bar Code Ratio, Define

0 yes s

Page, Delete no t

User-Defined Font Character, Clear or Create yes u

Graphic or UDC, Define yes v

Print Line Dot Count Limit, Set yes w

Width of Line, Box, Bar or Character, Define yes yes 0 yes yes

7-9

Page 154

4400 Bar Code Label Printer User’s Manual

Program Mode Commands (continued)

7-10

Command Code

Function

Factory Default x

Bitmap Cell Width for Graphic or UDF, Define yes y

Bitmap Cell Height for Graphic or UDF, Define yes z

Intercharacter Space for UDF, Define

;

Command Terminator yes

(

Null Command yes

)

Null Command yes

<CR>

Null Command yes

<LF>

Null Command yes

2

8636/46 Emulation yes

Page 155

HelvC NugFont

Co d e 39 Printer Commands

7

Summary of Test and Service Mode CommandsThe following table lists a summary of the available Test and Service mode commands. Each command is described in detail later in this chapter. Command Code

Function Description

A

Ambient Temperature, Transmit*

B

Printhead Resistance Test, Begin

C

Pitch Label, Print

D

Reset Printer Configuration

G

Gap Sensor Value, Transmit*

L

Label Path Open Value, Transmit*

M

Mark Sensor Value, Transmit*

P

Printhead Temperature, Transmit*

Q

Print Quality Label, Print

R

Test and Service Mode, Exit

S

Printhead Resistance Values, Transmit*

T

Label Taken Value, Transmit*

U

12 Volt Supply Value, Transmit*

V

24 Volt Supply Value, Transmit*

;

Command Terminator

Note: Commands denoted by an asterisk (*) will not receive a reply when used with a parallel interface.

7-11

Page 156

4400 Bar Code Label Printer User’s Manual

Using Printer Commands According to Function The following commands are grouped according to functionality.

Programming A

Format, Edit

F

Format, Edit

E

Format, Erase

S

Page, Create or Edit s

Page, Delete

R

Program Mode, Exit

N

Save

G

UDC, Clear or Create

J

UDF, Clear or Create Outline

T

UDF, Clear or Create Bitmap

Editing Pages q

Format Direction in a Page, Define

O

Format Offset in a Page, Define e

Format in a Page, Define Data Source

M

Format Position in a Page, Assign m

Format Position in a Page, Delete

Editing Formats

7-12

B

Bar Code Field, Create or Edit

W

Box Field, Create or Edit

D

Field, Delete

H

Human-Readable Field, Create or Edit

I

Interpretive Field, Edit

L

Line Field, Create or Edit

U

UDC Field, Create or Edit

Page 157

HelvC NugFont

Co d e 39 Printer Commands

7

Editing Bar Code Fields r

Bar Code Ratio, Define c

Bar Code Type, Select h

Bar Height Magnification, Define w

Bar Width Magnification, Define p

Code 39 Prefix Characters, Define f

Field Direction, Define i

Field Interpretive, Enable/Disable o

Field Origin, Define d

Source of Field Data, Define

Editing Human-Readable Fields b

Border, Define h

Character Height Magnification, Define w

Character Width Magnification, Define r

Character Rotation, Define f

Field Direction, Define o

Field Origin, Define c

Font Type, Select g

Pitch Size, Set k

Point size, Set d

Source of Field Data, Define

Editing Interpretive Fields b

Border, Define h

Character Height Magnification, Define w

Character Width Magnification, Define r

Character Rotation, Define f

Field Direction, Define o

Field Origin, Define c

Font Type, Select g

Pitch Size, Set k

Point size, Set

7-13

Page 158

4400 Bar Code Label Printer User’s Manual

Editing Line Fields f

Field Direction, Define o

Field Origin, Define l

Length of Line Field, Define w

Width of Line Field, Define

Editing UDC Fields h

Character Height Magnification, Define w

Character Width Magnification, Define f

Field Direction, Define o

Field Origin, Define c

UDC Type, Select

Editing Box Fields f

Field Direction, Define o

Field Origin, Define h

Height of Box Field, Define l

Length of Box Field, Define w

Width of Box Field, Define

Editing UDCs

7-14 y

Bitmap Cell Height of UDC, Define x

Bitmap Cell Width of UDC, Define u

One Column of Bitmap, Define

Page 159

HelvC NugFont

Co d e 39 Printer Commands

7

Editing Bitmap UDFs y

Bitmap Cell Height of UDF, Define x

Bitmap Cell Width of UDF, Define

X

Character Bitmap Origin Offset, Define t

Font Character, Define

Z

Font Character Width, Define z

Intercharacter Space, Define u

One Column of Bitmap, Define

Editing Outline UDFs j

Outline Font Description, Download y

Height of Base Character, Define x

Width of Base Character, Define

System <BEL>

Error Code, Request

<EM>

Print Job, Abort

<DLE>

Reset

<VT>

Status Dump

<ENQ>

Status Enquiry

<BS>

Warm Boot

7-15

Page 160

4400 Bar Code Label Printer User’s Manual

Printing

7-16

<ESC> c

86XX Emulation Mode, Select

<ESC> C

4400 Advanced Mode, Select

<GS>

Alphanumeric Field Separator

<US>

Batch Count, Set

<CAN>

Clear All Data

<DEL>

Clear Data From Current Field

<ACK>

Data Entry Field, Select First

<CR>

Data Entry Field, Select Next

<SUB>

Data Shift

<ESC> D

Field Decrement, Select

<ESC> F

Field, Select

<ESC> I

Field Increment, Set

<ESC> N

Field Increment/Decrement, Disable

<FF>

Form Feed

<ESC> E

Format, Select

<FS>

Numeric Field Separator

<ESC> G

Page, Select

<ETB>

Print

<ESC> P

Program Mode, Enter

<RS>

Quantity Count, Set

<ESC> <SP>

Start/Stop Characters Only, Enter

<ESC> T

Test and Service Mode, Enter