The text of a manual · part 14 of 32
4400 Bar Code Label Printer User's Manual, pages 131 to 140
Pages 131 to 140 of 318
The original document is the PDF (2.3 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 4400
Page 131
HelvC NugFont
Co d e 39 Designing Labels and Using Commands
6
For all types of fields, the print position is determined by defining the coordinates of the upper left corner of the unrotated field. The upper left corner of an unrotated field is referred to as the field origin. To define the coordinates of the field origin, you use the origin command (oxxx,yyy) where o is the command that specifies origin, xxx is the distance from the left side of the label, and yyy is the distance from the top of the label. The xxx and yyy coordinates of the field origin are measured in dots. There are 203.2 dots per inch, or 8 dots per millimeter. For example, to position a field to print one inch from the top of your label and approximately 1/2 inch from the left side, the origin command would be o101,203. Note: If you are operating your printer in 86XX emulation mode, the dot sizes will double in 10 mil mode and increase by 1.5 in 15 mil mode. To position a field which uses font c20, c21, c22, c23, c24, or c25 (the outline font), you must make an extra calculation. Where the origin of a bar code field, bitmap text field, line, box, or graphic is easy to determine, the outline font will seem to print below the field origin. This occurs because the outline font contains special characters that are actually larger than uppercase letters. These special characters require extra space between the top of the outline font uppercase letters and the origin of the field. If you are not using the special characters, but are trying to position an outline font field, set the yyy coordinate a little higher than you would for a different field.
Rotating Fields Any type of field you print can be rotated in increments of 90 degrees counterclockwise around the field origin. To position a rotated field, you should keep in mind that the field origin will remain on the corner where it was before the field was rotated. If a field is rotated 90 degrees counterclockwise, the origin (which used to be at the upper left corner but is now at the lower left corner) is still the origin. •
For fields that are rotated 90 degrees, you must position the lower left corner of the rotated field.
•
For fields that are rotated 180 degrees, you must position the lower right corner of the rotated field.
•
For fields that are rotated 270 degrees, you must position the upper right corner of the rotated field.
6-21
Page 132
*
*4400* fØ
*4400* * f3 f1
*
*4400* f2
*
*4400*
4400 Bar Code Label Printer User’s Manual
* = Field Origin 4400-71
Storing Label Formats When a label is defined, either by downloading printer commands or by using PrintSet or a similar program, the format is stored in the printer’s RAM. Once a label is stored in the printer, it can be used at any time. You can call it up to print labels with, or you call it up in Program mode to modify one or all of the fields.
Designing Pages A page is a collection of one or more formats that are combined to print at the same time. This is very practical in cases where you may need to attach several different labels on each one of your objects. For example, you may need to attach one kind of label to a product, and a different label to its container. With the printer’s page printing capability, you can print both labels at the same time. Being able to print pages of several formats at once also allows you to print labels on media rolls that have different sizes and shapes of labels already precut. When you group label formats into a page, the formats are put in positions that are assigned the letters a through z. Formats combined in pages may still be printed independently.
6-22
Page 133
HelvC NugFont
Co d e 39 Designing Labels and Using Commands
6
Using Printer Memory There is enough RAM in the printer to store several different label formats and still retain enough memory to store downloaded fonts, graphics, and data. Be careful of how you use your printer memory. There is a limit to how much can be stored in the printer. In its base configuration, the printer is equipped with 39K of static RAM. You may expand the available RAM to 295K by installing a RAM expansion board. There are limits to the number of formats, fonts, graphics, or pages that you can store in the printer. You can define up to 16 soft fonts, but there may not be enough room depending on the amount of memory being used for other purposes. The more formats, graphics, and fonts you store, the less memory is available. When you run into a memory usage problem, use the <ESC>m command to see how much memory remains available. If you find that it is necessary to increase your available memory, you can do one of the following: •
Use one of the Service Memory Reset menus to increase the amount of available memory in part or all of the sections. See “Increasing Available Memory” in Chapter 9 for more information.
•
The commands used to create a font or graphic can be used to delete them as well (see the Program mode commands in Chapter 7): Outline fonts: Jn without any following data will delete outline font n. Bitmap fonts: Tn without any following data will delete bitmap font n. UDCs: Gn without any following data will delete UDC n.
•
Use the Program commands (see Chapter 7) to delete pages and formats: Pages: Delete a page with the sn command. Formats: Erase format n by using the En command.
Format Examples Label formats (designs) incorporate the different types of fields that were previously described. Following are some practical examples of label designs.
6-23
Page 134
4400 Bar Code Label Printer User’s Manual
Example 1 The first example is a fairly simple label designed to demonstrate the different types of data that can be printed.
*3666* *3666*
4400-78
Format for Example 1 <STX><ESC>C<ETX> <STX><ESC>P<ETX> <STX>E3;F3;<ETX> <STX>H0;o162,200;f0;c2;d0,16;h2;w2;<ETX> <STX>H1;o162,300;f0;c2;d3,Warehouse Part # 3666;h2;w2;<ETX> <STX>B2;o162,400;f0;c0,1;h100;w2;i0;d0,11;p@;<ETX> <STX>L3;o162,530;f0;l600;h2;w6;<ETX> <STX>R<ETX>
Data for Example 1 <STX><ESC>E3<CAN><ETX> <STX>LOC 1246<CR><ETX> <STX>3666<ETX> <STX><ETB><ETX>
6-24
Page 135
HelvC NugFont
Co d e 39 Designing Labels and Using Commands
6
The <STX> and <ETX> characters mark the beginning and end of each command string. The semicolon (;) is the command terminator. All commands in Program mode must end with this terminator except the last command in a message. The other characters are described in the table below. Command
Description
<ESC>C
Sets 4400 (advanced) mode.
<ESC>P
Enters Program mode.
E3;
Erases anything previously stored as format three.
F3;
Creates format three.
H0;
Designates field zero as a human-readable field.
o162,200;
Sets the origin at grid coordinates (162,200).
f0;
Sets the field rotation to zero, which is unrotated or horizontal.
c2;
Selects internal font two.
d0,16;
Determines that data is sent during print mode and its maximum length is 16 characters.
h2;
Sets the height magnification factor to twice its original height.
w2;
Sets the field width magnification factor to twice its original width.
H1;
Defines field one as a human-readable field.
o162,300;
Sets the field origin at coordinates (162,300).
f0;
Sets the rotation factor of the field to zero.
c2;
Selects internal font two.
d3,Warehouse Part # 3666;
Determines that data for the field has this constant value: Warehouse Part # 3666.
h2;
Sets the field height magnification factor to twice its original height.
w2;
Sets the field width magnification factor to twice its original width.
B2;
Defines field two as a bar code field.
o162,400;
Sets the origin at coordinates (162,400).
f0;
Sets the field rotation to zero (unrotated).
c0,1;
Selects Code 39 with a check digit entered by the printer.
h100;
Sets the field height to 100 dots.
6-25
Page 136
4400 Bar Code Label Printer User’s Manual
Example 1 Command Descriptions (continued) Command
Description w2;
Sets the narrowest element width to two dots.
i0;
Determines that no human-readable interpretive field prints below the bar code.
d0,11;
Sets data from Print mode at 11 characters long.
p@;
Determines the bar code field has no prefix.
L3;
Defines field three as a line field.
o162,530;
Set the field origin at coordinates (162,530).
f0;
Define the field rotation as horizontal.
l600;
Determines the length of the line is 600 dots.
h2;
Sets the height magnification factor to twice its original height.
w6;
Determines the width of the line is six dots.
R
Exits Program mode and enters Print mode.
<ESC>E3
Accesses format three.
<CAN>
Clears all data for the current format and points to the lowest numbered field in the format that can accept variable data.
LOC 1246<CR>
This is the data for the first field in the format. Moves to the next field
3666
This is the data for the bar code field.
<ETB>
Prints the label.
6-26
Page 137
HelvC NugFont
Co d e 39 Designing Labels and Using Commands
6
Example 2 This example is given to demonstrate some of the more complex labels that you can design with the 4400 printer. This format has fields that include a graphic, lines, boxes, and several fields with constant data.
Cat. No.
432-3221
S i z e
3 4
Lot 23455 2629333
1
St. Qty.
100
DUPLEX ANGLE CONNECTOR
- For Flexible Steel Conduit and .375" - .625" Diameter Armored and Nonmetallic Sheath Cables - For Smooth or Interlocking Sheath Metal Clad Cables .375" - .675" Dia. (UL only)
ACE CORP. ADDRESS 3010 FICTION USA
*307,91751* *307 91751*
3400-63
Graphic for Example 2 <STX><ESC>c<ETX> <STX><ESC>P<ETX> <STX>G2,diam;x15;y15;<ETX> <STX>u0,000000010000000;<ETX> <STX>u1,000000101000000;<ETX> <STX>u2,000001000100000;<ETX> <STX>u3,000010000010000;<ETX> <STX>u4,000100000001000;<ETX> <STX>u5,001000000000100;<ETX> <STX>u6,010000000000010;<ETX> <STX>u7,111111111111111;<ETX> <STX>u8,011111110000010;<ETX> <STX>u9,001111110000100;<ETX> <STX>u10,000111110001000;<ETX> <STX>u11,000011110010000;<ETX> <STX>u12,000001110100000;<ETX> <STX>u13,000000111000000;<ETX> <STX>u14,000000010000000;<ETX> <STX>R<ETX>
6-27
Page 138
4400 Bar Code Label Printer User’s Manual
Format for Example 2 <STX><ESC>C<ETX> <STX><ESC>P<ETX> <STX>E5;F5;<ETX> <STX>H0;o45,40;c25;d3,Cat.;k10;<ETX> <STX>H1;o45,70;c25;d3,No.;k10;<ETX> <STX>H2;o175,0;c25;d3,432-3221;k40;<ETX> <STX>H3;o795,40;c25;d3,Std.;k10;<ETX> <STX>H4;o795,70;c25;d3,Qty.;k10;<ETX> <STX>H5;o925,0;c25;d3,100;k40<ETX> <STX>L6;o750,10;f3;l130;w8;<ETX> <STX>L7;o35,140;l1075;w8;<ETX> <STX>H8;o40,165;c25;f3;r1;d3,Size;k10<ETX> <STX>H9;o100,130;c25;d3,1 ";k40;<ETX> <STX>H10;o145,165;f3;r1;c25;d3,3/4;h16;w65;<ETX> <STX>L11;o310,140;f3;l130;w8;<ETX> <STX>L12;o35,270;l275;w8;<ETX> <STX>H13;o60,560;f1;c25;d0,20;k10;<ETX> <STX>L14;o170,270;f3;l310;w8;<ETX> <STX>H15;o350,140;c25;d3,DUPLEX ANGLE CONNECTOR;h70;w28;<ETX> <STX>H16;o205,320;c25;d3,- For Flexible Steel Conduit and .375" - .625";k12;<ETX> <STX>H17;o247,375;c25;d3,Diameter Armored and Nonmetalic Sheath Cables;k12;<ETX> <STX>H18;o205,450;c25;d3,- For Smooth or Interlocking Sheath Metal Clad;k12;<ETX> <STX>H19;o247,505;c25;d3,Cables .375" - .675" Dia. (UL only);k12;<ETX> <STX>L20;o35,580;l1075;w8;<ETX> <STX>U21;o50,610;c2;h9;w9;<ETX> <STX>H22;o220,600;c25;d3,ACE CORP.;k20;<ETX> <STX>H23;o220,670;c25;d3,ADDRESS 3010;k10;<ETX> <STX>H24;o220,710;c25;d3,FICTION USA;k10;<ETX> <STX>B25;o675,625;c0,0;d0,20;i25;h100;p@;<ETX> <STX>L26;o585,580;f3;l175;w8;<ETX> <STX>R<ETX>
Data for Example 2 <STX><ESC>E5<CAN><ETX> <STX>Lot 23455 2629333<CR>307 91751<ETX> <STX><ETB><ETX>
6-28
Page 139
HelvC NugFont
Co d e 39 Designing Labels and Using Commands
6
The <ETX> and <STX> characters are used to mark the beginnings and ends of the command strings. The other characters are explained in the following table. Command
Description
<ESC>C
Selects 4400 (advanced) mode.
<ESC>P
Selects Program mode.
E5;F5;
Erases anything previously stored as format five and accesses the location for format five.
H0;
Defines field zero as a human-readable field.
o45,40;
Sets the origin of field zero at coordinates (45,40).
c25;
Sets the font for field zero to font 25.
d3,Cat.;
Sets the data for field zero to have the constant value: Cat.
k10;
Sets the point size to 10.
H1;
Defines field one as a human-readable field.
o45,70;
Sets the origin of field one at coordinates (45,70).
c25;
Sets the fonts for field one to font 25.
d3,No.;
Set the data for field one the constant value: No.
k10;
Sets the point size to ten.
H2;
Defines field two as a human-readable field.
o175,0;
Sets the origin of field two at (175,0).
c25;
Sets the font of field two to font 25.
d3,432-3221;
Sets the constant data for field two.
k40;
Set the point size to 40.
H3;
Defines field three as a human-readable field.
o795,40;
Sets the origin of field three at (795,40).
c25;
Sets the font for field three to font 25.
d3,std.;
Defines constant data for field three.
k10;
Sets the point size to 10.
H4;
Defines field four as a human-readable field.
o795,70;
Sets the origin of field four at (795,70).
c25;
Sets the font for field four to font 25.
d3,Qty.;
Defines constant data for field four.
k10;
Sets the point size to ten.
6-29
Page 140
4400 Bar Code Label Printer User’s Manual
Example 2 Command Descriptions (continued) Command
Description
H5;
Defines field five as a human-readable field.
o925,0;
Sets the origin of field five at (925,0).
c25;
Sets the font for field five to font 25.
d3,100;
Defines the constant data for field five..
k40
Sets the point size to 40.
L6;
Defines field six as a line field.
o750,10;
Sets the origin for field six at (750,10).
f3;
Rotates field six 270 degrees counterclockwise around the field origin.
l130;
Sets the length of the line in field six to 130 dots.
w8;
Sets the width of field six to eight times its actual width.
L7;
Defines field seven as a line.
o35,140;
Sets the origin for field seven at (35,140).
l1075;
Sets the length of the line in field seven to 1075 dots.
w8;
Sets the line width to 8 dots.
H8;
Defines field eight as a human-readable field.
o40,165;
Sets the origin of field eight at (40,165).
c25;
Defines the font for field eight as font 25.
f3;
Rotates field eight 270 degrees counterclockwise around the origin.
r1;
Rotates the characters in field eight 90 degrees counterclockwise.
d3,Size;
Defines the constant data for field eight.
k10;
Sets the point size to ten.
H9;
Defines field nine as a human-readable field.
o100,130;
Sets the origin of field nine at (100,130).
c25;
Defines the font for field nine as font 25.
d3,1";
Defines constant data for field nine.
k40;
Sets the point size to 40.
H10;
Defines field ten as a human-readable field.
o145,165;
Sets the origin for field ten at (145,165).
f3;
Rotates field ten 270 degrees counterclockwise around the origin.
r1;
Rotates the characters in field ten 90 degrees counterclockwise.
6-30