Page 46

EasyCoder 4400 Printer Getting Started Guide

Note: After using memory reset you must reinstall the software drivers for options, such as cutter or self-strip. See Chapter 8, “Special Procedures,” in the 4400 Bar Code Label Printer User’s Manual for help reinstalling the software drivers.

Setting the Media Sensitivity Number Media sensitivity is important because you use it to optimize print quality and print speed. The three-digit sensitivity number specifies the amount of heat required by the printhead to image a label. The amount of heat that each roll of media or ribbon requires is unique to different chemistries and manufacturing processes. Intermec has developed heating schedules (the amount of heat required to image a label) to produce the highest possible print quality for Intermec media and ribbon combinations on Intermec printers. Look for the three digit media sensitivity number on: •

The side of the media roll. Use the last three digits (140 in the example) of the 15 digit number stamped on the roll for the media sensitivity number.

•

A small label attached to the roll of the media.

•

A small label attached to the plastic bag of your ribbon roll.

120066102605140 SENSITIVITY NUMBER

120066102605140

5✩7

3-4

4400G.021

Page 47

HelvC NugFont

Optimizing Print Quality Co de 39

3

Use this three-digit number to optimize print quality and print speed on the 4400 printer. You can achieve the best print quality on the 4400 printer by using Intermec ribbon and media products. The default printer setting for direct thermal media sensitivity is 420. For thermal transfer media, the default setting is 567. Use the information on the packaging that you saved when loading media and ribbon to determine the correct sensitivity number.

Setting the Media Sensitivity Number for Intermec Media and Ribbon The default printer setting for direct thermal media sensitivity is 420. For thermal transfer media, the default setting is 567. Use the information on the packaging that you saved when loading media and ribbon to determine the correct sensitivity number. The sensitivity number on each roll of thermal transfer media or ribbon has an asterisk (*) in place of one of the digits. To optimize the sensitivity number for thermal transfer media, you combine the digits as in this example. Media or Ribbon

Sensitivity Rating

Description

Thermal Transfer Media

56*

The asterisk reserves the third digit to identify the ribbon’s sensitivity number.

Thermal Transfer Ribbon

5*7

The asterisk reserves the second digit to identify the media’s sensitivity number.

567

Optimum Sensitivity Rating

To set the sensitivity rating for direct thermal media, use the three-digit sensitivity rating located on the roll of media or listed in the Direct Thermal Media Sensitivity Settings table later in this chapter. Use the PrintSet software, your third-party software, or the Intermec Printer Language (IPL) command set to change the media sensitivity number. For help setting the media sensitivity number using IPL commands, see the DOS example in the next section.

3-5

Page 48

EasyCoder 4400 Printer Getting Started Guide

Example of Setting the Media Sensitivity Number To set the media sensitivity number 1. At the DOS prompt, type the following command and press Enter. MODE COM1 96,E,7,N

2. Type the following command lines and press Enter. COPY CON COM1 <STX><SI>g1,567<ETX>^Z where: <SI>g1,567 sets the media sensitivity number for thermal transfer media to 567.

Setting the Media Sensitivity Number for Other Media and Ribbon If you are not using Intermec media and ribbon, or you misplaced your packaging with the three-digit sensitivity number label on it, you can set the approximate sensitivity setting. The approximate sensitivity numbers are the first entry (in bold text) for each series in the media sensitivity settings table on the following pages. Enter the three-digit approximate sensitivity setting (for example, 800) to achieve acceptable print quality.

3-6

Page 49

HelvC NugFont

Optimizing Print Quality Co de 39

3

Use the following tables to find the correct sensitivity rating for you direct thermal media or thermal transfer media and ribbon combination.

Direct Thermal Media Sensitivity Settings Approximate Sensitivity Ratings

Sensitivity Setting

Thermal Transfer Media/Ribbon

700 Series High Sensitivity

740

Duratherm Lightning Plus-1

720

Duratherm Lightning Plus-2

480

Duratherm Lightning IR-2

470

Duratherm Lightning-1

460

European Thermal IR

450

Duratherm Lightning IR-1

440

European Thermal Economy

430

Duratherm Lightning Synthetic

420

Duratherm Lightning-2

190

Duratherm Buff Tags

180

Duratherm II-1

170

European Thermal Top Board/Reinforced

160

Duratherm II Tag

150

Duratherm Buff Labels

140

European Thermal Top

130

Duratherm II-2

120

European Thermal Economy Tag

400 Series Medium Sensitivity

100 Series Low Sensitivity

3-7

Page 50

EasyCoder 4400 Printer Getting Started Guide

Thermal Transfer Media and Ribbon Sensitivity Settings Approximate Sensitivity Ratings

Sensitivity Setting

Thermal Transfer Media/Ribbon

800 Series High Sensitivity (Paper)

864

European Uncoated/Standard

854

Duratran I/Standard

834

Duratran I Tag/Standard

687

Duratran Matte Polyester/Premium

677

Duratran Syntran/Premium

647

Duratran Tyvek/Premium

633

European Polyethylene/Premium

627

Duratran Kimdura/Premium

567

Duratran II-1/Premium

565

Duratran European/Premium

547

Duratran II-2/Premium

533

European Tag/Premium

527

Duratran II Tag-5 mil and 7 mil/Premium

513

European Coated and Board Tag/Premium

369

Super Premium Poly./Super Premium 3

366

Super Premium Poly./Super Premium 7

238

Gloss Polyimide (Kapton)/Gloss Super Premium 7

236

Gloss Polyimide (Kapton)/Super Premium 7

226

Matte Polyimide (Kapton)/Super Premium 7

222

Matte Polyimide (Kapton)/Matte Super Premium

600 Series Medium Sensitivity (Plastic)

500 Series Medium Sensitivity (Paper)

300 Series Low Sensitivity (Plastic)

200 Series Low Sensitivity (Plastic)

3-8

Page 51

HelvC NugFont

Optimizing Print Quality Co de 39

3

Setting the Dark Adjust You can adjust the print darkness when the printer is online or offline. Use the dark adjust setting for fine-tuning only. Once you set the sensitivity rating, a darkness setting of zero should provide optimal print quality. However, as the printhead wears or if you use a lot of media, some adjustment may be necessary. Check the sensitivity rating before you use the dark adjust command. To adjust the darkness of your labels 1. Start at the ONLINE READY display: ONLINE READY

2. Press [MENU] to enter the Operator menu. Press [↑] or [↓] until the display shows: OPERATOR MENU DARK ADJUST

3. Press [SELECT]. The display shows the current dark adjust setting with an asterisk (*) as shown in the example below: DARK ADJUST 5*

4. Press [↑] to increase the number and darken the printing. Press [↓] to decrease the number and lighten the printing. The range is from -10 (lightest) to 10 (darkest). 5. Press [ENTER] at the desired setting. The asterisk (*) moves to the new setting as shown in the example below: DARK ADJUST 3*

6. Press [CONTINUE] to return to the ONLINE READY display. Print out a few labels. Also, scan some labels to see if they are too dark or light for you to scan. 7. If the labels are too dark or too light, repeat Steps 3 through 6.

3-9

Page 52

EasyCoder 4400 Printer Getting Started Guide

Components to Maintain Clean your printer regularly to maintain the quality of your labels and extend the life of your printer. The following table contains suggestions for cleaning the printer. To clean the printer effectively and safely use the following items: isopropyl alcohol, a cleaning brush, cotton swabs, and a clean lint-free cloth. Printer Component

Maintenance Period

Printhead

Inspect after every roll of media. Clean after every five rolls of media.

Platen Roller and Tear Bar

Clean after every ten rolls of media. If you are using hi-tack adhesive, you must clean after every roll of media. If you are using tag stock or continuous media, you should clean after every five rolls of media.

Label Gap and Label Mark Sensors Media Pathway and Edge Guides

Printer Cover

Clean as necessary.

Printer cover

®

44

00

SE

LE

CT

AL

MEN

EN

ER

U

TE

T

R

0P

EN

PO

CO

WE

NT

INUE

R

FE

ED

RE

LO

AD

ON

LIN

E

ON LIN OF F LIN E E

Printhead

Media pathway

Edge guides

Platen roller Tear bar

4400G.022

3-10

Page 53

HelvC NugFont

Optimizing Print Quality Co de 39

3

Cleaning the Printer The following procedures tell you how to access and clean the printer components without causing any damage. Note: Turn off and unplug the printer before cleaning any components. The following procedures include instructions for opening the printer without power.

Removing the Ribbon Access Door To open the printer without power, you must remove the ribbon access door. To remove the ribbon access door 1. Turn off and unplug the printer. 2. Remove the ribbon access door by turning the knob 1/4 turn counterclockwise, and lifting the door away from the printer.

®

44

00

SE LE CT

AL

ER

MEN U

EN TE R

T

0P EN

PO

WE

CO R

NT

INUE

FE

ED

RE

LO

AD

ON

LIN

E

ON LINE OF F LI NE

4400G.013

3-11

Page 54

EasyCoder 4400 Printer Getting Started Guide

Opening the Printer for Cleaning 1. Press down on the manual cover release and lift the cover. 2. Remove the media and thermal transfer ribbon.

®

44

00

SE

LE

CT

AL

MEN

EN

ER

U

TE

T

R

0P

EN

PO

WE

CO R

NT

INUE

FE

ED

RE

LO

AD

ON

LIN

E

ON LINE OF F LI NE

4400G.023

Cleaning the Printer Case Clean the case with a lint-free cloth and isopropyl alcohol as necessary to remove dust from cooling vents. If the vents become obstructed, the printer may overheat, which can result in pauses while printing labels and damage to the electronic circuitry inside the printer.

3-12