Page 61

Helvitica condensed 9 pt italic

Co d e

39

18 pt Installing the Printer

2

The 4100 printer supports serial communications with the following Electronics Industries Association (EIA) interfaces: • RS-232C • RS-422 • RS-485 These interfaces are described below. You may also find more detailed information in the Data Communications Reference Manual (Intermec Part No. 044737). The table that follows these interface descriptions lists the appropriate pin assignments for each interface.

RS-232C Serial Interface The RS-232C serial interface is used in all asynchronous point-to-point full or half-duplex direct data communications or modem control. The cable connected to the printer must have the pin assignments listed in the table to operate properly under RS-232C.

Pin 20 Pin 20 of the RS-232C interface is the primary pin used by the 4100 printer to indicate its status when standard protocol is selected. Pin 20 is high when the printer status is ready. Pin 20 is low when the printer is in one of these conditions: • Buffer full • Ribbon fault • No label stock • Label at strip pin • Offline In XON/XOFF or hardware flow control, pin 20 and pin 11 indicate the printer mechanical status and the status of the printer input buffer. They are high when there is room in the buffer and low if the buffer is full or the printer is offline.

Pin 11 Pin 11 of the RS-232C interface is used by the 4100 printer to indicate its status. In Intermec Standard protocol, pin 11 still used for backward compatibility to the 86XX product line. It is high when the printer status is ready. Pin 11 is low during the same conditions as when pin 20 is low.

2-15

Page 62

Helvitica condensed 9 pt italic

Co d e

39

18 pt

4100 Bar Code Label Printer User's Manual

RS-485 Serial Interface The RS-485 serial interface is used for multi-drop installations only. The cable connected to the printer must have the pin assignments listed in the table to operate properly under RS-485.

Interface

Pin No.

Name

Operation

RS-232/422/485

1

Chassis Ground (GND)

Connect to pin 1, chassis ground, of connected device.

RS-232

2

Transmit Data (TD)

Output: Connect to receive data pin of connected device.

RS-232

3

Receive Data (RD)

Input: Connect to transmit data pin of connected device.

RS-232/422/485

4

Request to Send (RTS)

Output: When a modem is used, connected to modem RTS pin. RTS is set to true before transmission. The printer sets RTS to false after transmission.

RS-232/422/485

5

Clear to Send (CTS)

Input: When a modem is used, connect to modem CTS pin. Modem must set CTS true before the printer transmits data. If not connected, CTS sets itself true.

RS-232/422/485

7

Signal Ground

To enable communications, connect to signal ground of connected device. Completes circuit for all RS-232 signals.

RS-232/422/485

11

Printer Status (PS)

Output: When not using software flow control (XON/XOFF), connect to input of connected device (CTS). Indicates printer mechanical status and status of printer input buffer.

RS-422/485

13

Input B

Input: Serial differential data to the printer.

RS-422/485

14

Output A

Output: Serial differential data from the printer.

RS-422/485

16

Input A

Input: Serial differential data to the printer.

RS-422/485

19

Output B

Output: Serial differential data from the printer.

RS-232/422/485

20

Data Terminal Ready (DTR)

Output: When a modem is used, connect to modem DSR pin. Indicates the printer is switched on. When using XON/XOFF or hardware flow control, this pin indicates the printer mechanical status and the status of printer input buffer.

2-16

Page 63

Helvitica condensed 9 pt italic

Co d e

39

18 pt Installing the Printer

2

RS-422 Serial Interface The RS-422 interface is used in long line point-to-point direct connect installations. The cable connected to the printer must have the pin assignments listed in the table to operate properly under RS-422.

Printer Serial Port The serial port connection is on the printer rear panel. It is a 25-pin D-style subminiature receptacle. The port is wired as a data terminal equipment (DTE) device. Refer to the following illustration for the serial port pin assignments.

Printer RS-232/422/485 Serial Port

DTR

25 1 3 24 1 2 23 1 1 22 1 0 21 9 20

8

19

7

18

6

17

5

16

4

15

3

14

2 1

PS

SG CTS RTS RD TD GND 4100-09

Choosing the Correct Cable Your 4100 printer has many different cabling options available. Your choice of cabling depends on the network configuration, hardware interface, protocol used, cabling distance, and the electrical and environmental operating conditions of your printer. For typical installations, Intermec recommends the following: • Shielded cable, minimum 24 gauge • 25-pin D-style subminiature connector with metal backshell • Cable shield connected to metal backshell • EIA RS-232, RS-422, or RS-485 electrical interface

2-17

Page 64

Helvitica condensed 9 pt italic

Co d e

39

18 pt

4100 Bar Code Label Printer User's Manual

Intermec Cables Intermec offers a full line of interface cables. These cables are not included with the printer and must be ordered separately. Contact your Intermec representative for ordering assistance. For connecting the 4100 printer to an IBM PC AT or compatible, use this Intermec cable: Intermec Part No. 048693. For connecting the 4100 to an IBM PC XT or compatible, use this Intermec cable: Intermec Part No. 048668.

Cable Schematics If you are making your own cables, the following diagrams show cable schematics for some of the more commonly used cables.

RS-232 Null Modem Cable for PC

SHIELD 25-PIN (SOCKET) D-SUB METAL BACKSHELL

25-PIN (PLUG) D-SUB METAL BACKSHELL

CHASSIS GROUND

1

1

CHASSIS GROUND

TRANSMITTED DATA

2

3

RECEIVED DATA

2

TRANSMITTED DATA CARRIER DETECT

RECEIVED DATA

3

REQUEST TO SEND

4

CLEAR TO SEND

5

8

DATA SET READY

6

20 DATA TERMINAL READY

GROUND

7

7

GROUND

DATA TERMINAL READY 20

6

DATA SET READY

CARRIER DETECT

4

8

5 PC

PRINTER

NOTE: The metal backshell is connected directly to the shield to achieve electrostatic discharge (ESD) immunity.

2-18

CLEAR TO SEND

4100-12

Page 65

Helvitica condensed 9 pt italic

Co d e

39

18 pt Installing the Printer

2

RS-232 Null Modem Cable for AT SHIELD 9-PIN (SOCKET) D-SUB METAL BACKSHELL

25-PIN (PLUG) D-SUB METAL BACKSHELL 1

CHASSIS GROUND

RECEIVED DATA

2

2

TRANSMITTED DATA

TRANSMITTED DATA

3

3

RECEIVED DATA

8

CARRIER DETECT DATA SET READY

CLEAR TO SEND

8

REQUEST TO SEND

7

DATA TERMINAL READY

4

6

DATA SET READY

6

20 DATA TERMINAL READY

CARRIER DETECT

1

5

CLEAR TO SEND

4

REQUEST TO SEND

5

7

GROUND

AT

PRINTER

GROUND

NOTE: The metal backshell is connected directly to the shield to achieve electrostatic discharge (ESD) immunity.

4100-11

RS-422 Software Flow Control Null Modem Cable for AT SHIELD 25-PIN (PLUG) D-SUB METAL BACKSHELL 1

RECEIVED DATA 13 16

TRANSMITTED DATA 14 19

+

-

➤ ➤

CHASSIS GROUND

25-PIN (PLUG) D-SUB METAL BACKSHELL

+

+

➤ ➤

+

-

PRINTER

-

-

1

CHASSIS GROUND

13

TRANSMITTED DATA

16

14

RECEIVED DATA

19 HOST

NOTE: The metal backshell is connected directly to the shield to achieve electrostatic discharge (ESD) immunity.

4100-14

2-19

Page 66

Helvitica condensed 9 pt italic

Co d e

39

18 pt

4100 Bar Code Label Printer User's Manual Straight Through DTE to DCE Cable for Use With a Modem SHIELD 1

Input RxDA 16

Output TxDA 14 Output TxDB 19

+ -

➤ ➤

Input RxDB 13

1

-

➤ ➤

+

PRINTER

NOTE: Connect pin 1 to shield at one end only.

19 14

16 13 HOST 4100-15

RS-485 (Multi-Drop) Cables Refer to the following manuals for information on multi-drop cabling and connections. • 9154 Multi-Drop Line Controller System Manual Part No. 048517 • 9161B Installation Manual Part No. 049572

Cabling Considerations in Noisy Electrical Environments The items listed below create noisy electrical environments that can disrupt data communications between your host computer and the 4100 printer: • Large power transformers • Large electrical motors • Arc welders • Motor controllers • Switch gears

2-20

Page 67

Helvitica condensed 9 pt italic

Co d e

39

18 pt Installing the Printer

2

If any of these items are near the printer, you can reduce the effects of their electrical noise by following these directions: • Always use shielded cable. Connect the cable and shield to the metal backshells on the cable connectors and fasten the connectors to the serial ports using screws. • Install ferrite cable clamps. • Connect the printer chassis ground to the building ground. The chassis ground is on the ground pin of the printer power cord. Some experimentation may be required to eliminate the problems. If you need help, ask your Intermec representative for assistance.

2-21

Page 68

Helvitica condensed 9 pt italic

Co d e 4100 Bar Code Label Printer User's Manual

2-22

39

18 pt

Page 69

Helvitica condensed 9 pt italic

Co d e

39

18 pt

Operating the Printer

3 3

Operating the Printer

3-1

Page 70

Helvitica condensed 9 pt italic

Co d e 4100 Bar Code Label Printer User's Manual

3-2

39

18 pt