The text of a manual · part 24 of 29
4100 Bar Code Label Printer User's Manual, pages 231 to 240
Pages 231 to 240 of 282
The original document is the PDF (1.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 4100
Page 231
Helvitica condensed 9 pt italic
Co d e
39
18 pt Printer Commands
7
Interpretive Field, Edit Purpose:
Use this command to edit an interpretive field.
Syntax:
I{n} n is the ID number of the corresponding bar code field. The range is from 0 to 199.
Notes:
n is the field ID number of the bar code field to be interpreted. Interpretive fields cannot be created with this command; they can only be created or deleted when editing the corresponding bar code field.
Interpretive Field, Enable or Disable Purpose:
Determines if the interpretive field of the current bar code field prints.
Default:
n=0
Syntax:
i{n} Enter n=0 to disable interpretive field. Enter n=1 to enable interpretive field with start and stop characters. Enter n=2 to enable interpretive field without start or stop characters.
Notes:
When enabled, the human-readable information in font 0 (7x9 standard) is printed 2 dots below the bar code field, left justified. Use the I command to edit an interpretive field.
Length of Line or Box Field, Define Purpose:
Defines the length of a line or box. The length of a line or box field is given in number of dot increments.
Default:
n=100 dots
Syntax:
l{n} n values can range between 1 and 9999 dots.
7-61
Page 232
Helvitica condensed 9 pt italic
Co d e
39
18 pt
4100 Bar Code Label Printer User's Manual
Line Field, Create or Edit
FrGoth
Purpose:
Use this command to access or create a line field n.
Default:
n=0
Syntax:
L{n}{,name} n values can range between 0 and 199. ,name is an optional field. The field can be up to eight ASCII characters.
Notes:
Parameters for the default field: Field origin Field direction Line length Line width
0,0 0 degrees 100 1
Outline Font, Clear or Create Purpose:
Clears/creates on outline user-defined font.
Syntax:
J{n}{,name} The font ID is n and ,name is an optional field of up to eight ASCII characters except for the semicolon. If font set n has already been defined, all previous font description will be erased.
Notes:
This command is only available with the addition of expanded RAM.
Outline Font, Download
7-62
Purpose:
Downloads outline font descriptions where n is the information describing all characters within the font.
Syntax:
j{font description...}
Notes:
The printer will store the incoming font description into the font selected by the J command. This command is only available with the addition of expanded RAM.
Page 233
Helvitica condensed 9 pt italic
Co d e
39
18 pt Printer Commands
7
Page, Create or Edit Purpose:
Use this command to edit or create a page.
Syntax:
S{n} n is the numeric page ID. Values for n can range between 1 and 9.
Notes:
The default page cannot be edited. An error code is generated if a page number is out of range.
Page, Delete Purpose:
Use this command to delete a page.
Syntax:
s{n} n is the numeric page ID. n values can range between 1 and 9.
Notes:
The default page (page 0) cannot be deleted.
Pitch Size, Set Purpose:
In advanced mode, this command can be used to set the pitch size which can define the size of the characters in human-readable fields. When used, the height and width magnification and point size are disabled.
Default:
n=12
Syntax:
g{n} n values can range between 1 and 50.
Notes:
This command can be used for both bitmap and outline fonts. Pitch is characters per line. A higher pitch results in smaller characters.
Point Size, Set Purpose:
In advanced mode, this command can be used to set the point size which can define the size of the characters in human-readable fields.
Default:
n=12
7-63
Page 234
Helvitica condensed 9 pt italic
Co d e
39
18 pt
4100 Bar Code Label Printer User's Manual Syntax:
k{n}
FrGoth n values can range between 4 and 212. Notes:
This command works most effectively on fonts c20, c21, and c22. The printer must be in advanced mode to use this command. Point size equals 1/72 inch. A higher point size means larger characters.
Print Line Dot Count Limit, Set Purpose:
This is a null command and is ignored by the printer.
Syntax:
v{n}
Program Mode, Exit Purpose:
Instructs the printer to exit program mode and enter print mode. Any format or page currently being edited is saved.
Syntax:
R
User-Defined Character, Clear or Create Purpose:
This is the command to clear or create a graphic bitmap.
Syntax:
G{n}{,name} n values can range between 0 and 99. ,name is an optional field. The field can be up to eight ASCII characters except for semicolon, but cannot start with a numeric character.
Notes:
If graphic n has already been defined, it is erased and redefined.
User-Defined Character Field, Create or Edit
7-64
Purpose:
Use this command to edit or create a graphic field n.
Default:
n=0
Page 235
Helvitica condensed 9 pt italic
Co d e
39
18 pt Printer Commands
Syntax:
7
U{n}{,name} n values can range between 1 and 199. ,name is an optional field. The field can be up to 8 ASCII characters, except a semicolon.
Notes:
Parameters for the default field: Field origin Field direction Character rotation UDC Height magnification Width magnification
0,0 0 degrees 0 degrees 0 1 1
User-Defined Font Character, Create Purpose:
Specifies which font character is to be defined next.
Syntax:
t{n} n values can range between 0 and 255. n is the decimal representation of the ASCII character; existing characters are erased.
Width of Line, Box, Bar, or Character, Define Purpose:
Defines the width magnification of a line, box, bar code, or character. For line, box, or bar code fields, the width of the narrow element is defined by number of dot increments n. For human-readable fields, graphics and the POSTNET symbology, n is the magnification of the character width.
Default:
n=1
Line, box, bar code fields, and graphics (drag).
n=2
Human-readable fields and POSTNET (picket and bar code fields.
Syntax:
w{n} Values for n can range between 1 and 9999 for line, box, and bar code fields. Human-readable fields, graphics, and POSTNET symbology values can range between 1 and 250.
7-65
Page 236
Helvitica condensed 9 pt italic
Co d e
39
18 pt
4100 Bar Code Label Printer User's Manual
Test and Service Mode Commands FrGoth The following table gives descriptions of the test and service mode commands. To enter Test and Service mode from Print mode, send <ESC>T from the host terminal. Note: All commands in Test and Service mode end with the command terminator (;), except the last command in a message.
Command Code
Summary
Description
A
Transmit Ambient Temperature*
Transmits the ambient temperature sensor A/D output back to the host. The value ranges from 00 to 255.
B
Begin Printhead Resistance Test*
Causes the printer to begin the printhead resistance test. The printer responds with the ASCII character string "pass" or "fail".
C
Print Pitch Label*
Causes the printer to print the pitch label.
D
Reset Factory Defaults
Sets the printer configuration to the factory defaults. When you exit Test and Service mode after sending this command, the printer performs a warm boot (it resets).
G
Transmit Transmissive Sensor Value
Transmits the label gap transmissive sensor A/D output back to the host. Value ranges from 00 to 255.
K
Dark Adjust*
This command changes the darkness of the print on your labels. It is for fine-tuning only.
L
Transmit Label Path Open Sensor Value*
Transmits the paper path open switch value back to the host. A value of 0 indicates the paper path is open and a value of 1 means it is closed.
M
Transmit Reflective Sensor Value
Transmits the label mark reflective sensor A/D output back to the host. Range of the value is 00 to 255.
P
Transmit Printhead Temperature Sensor Value
This command transmits the printhead thermistor A/D output back to the host. Range of the value is 00 to 255.
Q
Print Quality Label
Causes the printer to print out the print quality program and model number label.
7-66
Page 237
Helvitica condensed 9 pt italic
Co d e
39
18 pt Printer Commands
7
Command Code
Summary
Description
R
Exit Test and Service
Causes the printer to exit Test and Service mode.
S
Transmit Printhead Resistance Values*
Transmits the average, maximum, and minimum printhead resistance value back to the host. Each value is a numeric data string separated by a comma.
T
Transmit Label Taken Sensor Transmits the label taken sensor A/D output back to the Value host. The value can range from 00 to 255.
U
Transmit 40 Volt Supply Value*
Transmits the 40 volt supply A/D output back to the host. The range of the value is 00 to 255.
V
Transmit Printhead Volt Supply Value*
Transmits the printhead volt supply A/D output back to the host. The range of the value is 00 to 255.
;
Command Terminator
All commands in Test and Service mode must end with the command terminator except for the last command in a message.
*The 4100 printer ignores this command.
User-Defined Interface Tables The following tables show commands, in the order they must be downloaded, when you replace the User-Defined Command/Protocol characters. There is a table for each type of command, as specified by a specific value for t.
7-67
Page 238
Helvitica condensed 9 pt italic
Co d e
39
18 pt
4100 Bar Code Label Printer User's Manual
Print Commands (t=0)
FrGoth
The following list shows the Print mode commands, in the order they must be downloaded, when you are replacing the command codes.
7-68
Print Command Description
Default Print Command
Command Terminator 1
NUL
Set Preamble
SOH
Set Postamble
EOT
Status Inquiry
ENQ
Select First Data Entry Field
ACK
Transmit Error Code
BEL
Warm Boot
BS
Command Terminator 2
LF
Status Dump
VT
Form Feed
FF
Select Next Data Entry Field
CR
Label Cut Command
SO
Go To Shift Command Table
SI
Reset
DLE
Set Intercharacter Delay
SYN
ETB
Clear All Data
CAN
Abort Print Job
EM
Data Shift
SUB
Go To Escape Command Table
ESC
Numeric Field Separator
FS
Alphanumeric Field Separator
GS
Set Quantity Count
RS
Set Batch Count
US
Clear Data From Current Field
DEL
Page 239
Helvitica condensed 9 pt italic
Co d e
39
18 pt Printer Commands
7
Escape Print Commands (t=1) This table lists the <ESC> commands in the order they must be downloaded. Escape Command Description
Default Escape Command
Set Message Delay
SYN
Enter Start/Stop Character
(space)
Select Advanced Mode
C
Set Field Decrement
D
Select Format
E
Select Field
F
Select Page
G
Transmit Printhead Parameters
H
Set Field Increment
I
Transmit Label and Gap Length
L
Transmit Software Version Number
M
Disable Increment/Decrement
N
Transmit Options Selected
O
Enter Program Mode
P
Transmit Quantity and Batch Count
Q
Enter Test and Service Mode
T
Transmit User-Defined Command Tables
Z
Select 86XX Emulation Mode c
Enable Auto-Transmit 2 d
Enable Auto-Transmit 3 e
Enable Auto-Transmit 1 j
Disable Auto-Transmit 1, 2 and 3 k
Transmit Static RAM Usage m
Transmit Configuration Parameters p
Transmit User-Defined Characters u
Transmit Font v
Transmit Format x
Transmit Page y
7-69
Page 240
Helvitica condensed 9 pt italic
Co d e
39
18 pt
4100 Bar Code Label Printer User's Manual
Shift Print Commands (t=2)
FrGoth
The following list shows the Shift commands in the order they must be downloaded. These commands must be preceded by the “Go To Shift Command Table” command (default value SI) listed in the table of Print Commands (t=0).
7-70
Shift Command Description
Default Shift Command
Control Panel Access
A
86XX or Advanced Mode on Power Up
C
Set End-of-Print Skip Distance
D
Set Top of Form
F
Set Printhead Pressure
H
Set Number of Image Bands
I
Set Maximum Label Length
L
Define Amount of Storage
N
Online or Offline on Power Up
O
Enable or Disable Label Retract
R
Set Print Speed
S
Select Label Stock Type
T
Set Printhead Test Parameters
U
Set Label Width
W
Set Ribbon Save Zone
Z
Audible Alarm a
Enable or Disable Cutter c
Set Dark Adjust d
Adjust Label Rest Point f
Select TTR or Direct Thermal g
IBM Language Translation i
Select Printer Language l
Set Label Retract Distance r
Enable or Disable Self-strip t