Page 211

Helvitica condensed 9 pt italic

Co d e

39

18 pt Printer Commands

Print Speed (ips)

Minimum Dot Increments

Minimum Inches

Print Speed (ips)

Minimum Dot Increments

Minimum Inches

2.5

135

0.675

5.5

220

1.10

3.0

148

0.74

6.0

232

1.16

3.5

163

0.815

6.5

246

1.23

4.0

179

0.895

7.0

263

1.315

4.5 5.0

193 210

0.965 1.05

7.5 8.5

283 306

1.415 1.53

Notes:

7

The ribbon save option must be installed or the printer will ignore this command. Setting a ribbon save zone enables ribbon save. Entering no ribbon save zones clears all ribbon save zones within this label. If only one parameter is entered, the command is ignored. The maximum number of zones possible on one label is 10. Additional zones are ignored. This command is buffered up and becomes effective upon execution.

Self-Strip, Enable or Disable Syntax:

<SI>t{n}

Notes:

This command is ignored by the 4100 printer. However, you can enable self-strip by using the DIP switches.

Top of Form, Set Purpose:

Sets the top of form (left margin) to n which is the distance, in dot increments, from the label origin to its leading edge.

Default:

n=20

Syntax:

<SI>F{n} n must be a number from -10 to 4000 dot increments.

Notes:

This command is effective upon execution.

7-41

Page 212

Helvitica condensed 9 pt italic

Co d e

39

18 pt

4100 Bar Code Label Printer User's Manual

Program Mode Commands FrGoth Program mode commands are used specifically for label format design and to download user-defined fonts and graphics. To set the printer to Program mode, send the following command string: <STX><ESC>P<ETX> When you create or edit formats, the printer uses a field pointer to designate the field that is to be modified when the printer is in Program mode. To download commands in Program mode, you must specify the field to be changed. If you do not select a field, the pointer continues to point to the last selected field until a different format or field is selected. Note: Each string of commands must be preceded by the start of message character <STX>, and followed by the end of message character <ETX>. The semicolon (;) is the command terminator. All commands in Program mode must end with this terminator except the last command in a message. Parentheses {( )} and <LF> characters are ignored by the printer. New formats contain a default human-readable field numbered H0. New pages do not contain a default format. The following command descriptions explain the commands that are effective when the printer is in Program mode. The command descriptions are listed in alphabetical order.

7-42

Page 213

Helvitica condensed 9 pt italic

Co d e

39

18 pt Printer Commands

7

Bar Code, Select Type Purpose:

Selects a symbology for a bar code field.

Default:

n=0

Syntax:

c{n}{,m1}{,m2}{,m3}; Values for n can range from 0 to 11.

Notes:

Modifiers apply only to bar code symbologies. For more information on bar code symbologies, please refer to The Bar Code Book by Roger Palmer (Intermec Part No. 051241). Bar codes may be selected in the following manner with the following optional modifiers:

c0{,m}

Select Code 39. The default for m is 0.

Intermec printers support 3 different types of Code 39: 43 character Code 39, full ASCII Code 39, and the 8646 compatible Code 39. The 8646 compatible version only differs from the full ASCII version by four characters. The “$”, “%”, “/”, and “+” are encoded as single characters instead of as “/D”, “/E”, “/O”, and “/K”. The 8646 compatible version allows the 4100 printer to be backward compatible with 86XX printers. If you enter <ESC><SPACE> as data, the start and stop characters are printed. c0,0

Select 8646 compatible Code 39. No check digit.

c0,1

Select 8646 compatible Code 39. Printer enter check digit.

c0,2

Select 8646 compatible Code 39. Host enters check digit and printer verifies.

c0,3

Select full ASCII Code 39. No check digit.

c0,4

Select full ASCII Code 39. Printer enters check digit.

c0,5

Select full ASCII Code 39. Host enters check digit and printer verifies.

7-43

Page 214

Helvitica condensed 9 pt italic

Co d e

39

18 pt

4100 Bar Code Label Printer User's Manual c0,6

Select 43 character Code 39. No check digit.

c0,7

Select 43 character Code 39. Printer enters check digit.

c0,8

Select 43 character Code 39. Host enters check digit and printer verifies.

c1

Select Code 93.

c2{,m}

Select Interleaved 2 of 5. Default for m is 0.

FrGoth

A zero is added to character strings that are odd in length. c2,0

Select Interleaved 2 of 5. No check digit.

c2,1

Select Interleaved 2 of 5. Printer enters check digit.

c2,2

Select Interleaved 2 of 5. Printer enters check digit.

c3{,m}

Select Code 2 of 5. Default for m is 0.

c3,0

Select Code 2 of 5. 3-bar start/stop code.

c3,1

Select Code 2 of 5. 2-bar start/stop code.

c4{,m}

Select Codabar. Default for m is 0.

Valid start/stop characters range from “A” to “D” and from “a” to “d”. They can be defined as part of the bar code field or they can be downloaded as part of the print data. Start/stop characters sent down with printer data override the characters defined by the bar code field.

7-44 c4,0

Select Codabar. Host enters start/stop codes and printer verifies.

c4,1,x,y

Select Codabar. Printer enters start code x and stop code y; x and y can range from A to D.

c5{,m}

Select Code 11. The default for m is 0.

c5,0

Select Code 11. Printer enters 2 check digits.

c5,1

Select Code 11. Printer enters 1 check digit.

c5,2

Select Code 11. Host enters 2 check digits and printer verifies.

c5,3

Select Code 11. Host enters 1 check digit and printer verifies.

Page 215

Helvitica condensed 9 pt italic

Co d e

39

18 pt Printer Commands c6{,m1}{,m2}

7

Select Code 128. The default for m1 is 0 (Code 128). The default for m2 is 0 (keep parentheses and spaces).

In 86XX Emulation mode, the Function 1 character can be printed by entering <SUB> 1. In Advanced mode, the Function 1 character can be printed by entering <SUB><SUB> 1. The characters for Function 2, 3, and 4 are represented in the same way. UCC-128 serial shipping container code automatically starts in subset C and a <FNC1>. It is a fixed length version of Code 128 requiring 19 numeric characters to be entered. The first two characters are forced to zeros. c6,0,0

Code 128. Keep parentheses and spaces.

c6,0,1

Code 128, ignore parentheses and spaces in the bar code but keep them in the interpretive field.

c6,1,0

Select UCC-128 Serial Shipping Container Code. Keep parentheses and spaces.

c6,1,1

Select UCC-128 Serial Shipping Container Code. Ignore parentheses and spaces in the bar code but keep them in the interpretive.

c7{,m}{,m2}

Select UPC/EAN Codes. Default for m1 is 0.

The variable length option selects the UPC/EAN version by the number of characters in the data field. The number of data characters and check characters allowed for each version are: EAN 8

7 data + 1 check character

EAN 13

12 data + 1 check character

UPC version A

11 data + 1 check character

UPC version E

6 data + 1 check character

UPC version D1

13 data + 1 check character

UPC version D2

18 data + 2 check characters

UPC version D3

22 data + 2 check characters

UPC version D4

25 data + 3 check characters

UPC version D5

29 data + 3 check characters

7-45

Page 216

Helvitica condensed 9 pt italic

Co d e

39

18 pt

4100 Bar Code Label Printer User's Manual A “.” is used to delimit the bar code data from the supplemental data. Data to the right of the “.” is supplemental data; data to the left is bar code data. The two or five digit supplemental can be added to any version of the UPC/EAN code.

FrGoth

The flag 1 option only applies to EAN 8, EAN 13, and UPC version A. For EAN 13, enabling the flag 1 option prints the first character of the bar code interpretive. For EAN 8 and UPC version A, enabling the flag 1 option moves the first and last character of the bar code interpretive outside of the guard bars. c7,0{,m2}

Select UPC/EAN Codes. Printer enters check digit and flag 1 enable.

c7,1{,m2}

Select UPC/EAN Codes. Printer enters check digit and flag 1 disabled.

c7,2{,m2}

Select UPC/EAN Codes. Host enters check digit and printer verifies Flag 1 enabled.

c7,3{,m2}

Select UPC/EAN Codes. Host enters check digit and printer verifies. Flag 1 disabled.

m2 selects UPC/EAN codes as listed below. Default is 0. 0 1 2 3 4 5 6 7 8 9 c8{,m1}{,m2}

7-46 variable length EAN 8 EAN 13 UPC Version A UPC Version E UPC Version D1 UPC Version D2 UPC Version D3 UPC Version D4 UPC Version D5

Selects HIBC Code 39. Default for m1 is 0. m2 is the field identifier.

Page 217

Helvitica condensed 9 pt italic

Co d e

39

18 pt Printer Commands

7

The next three modifiers conform to Supplier Standard: c8,0

Select HIBC Code 39. Primary format.

c8,1

Select HIBC Code 39. Alternate primary format.

c8,2,m2

Select HIBC Code 39. Secondary format. The linkage character comes from m2, which is the field identifier.

The next four modifiers conform to Provider Standard: c8,3

Select HIBC Code 39. Single format.

c8,4

Select HIBC Code 39. First data format.

c8,5,m2

Select HIBC Code 39. Second data format. The linkage character comes from m2, which is the field identifier.

c8,6

Select HIBC Code 39. Multiple data format.

c9

Select Code 16K.

<SUB> 1 is used to represent the Function 1 character in 86XX Emulation mode. In Advanced mode, the Function 1 character is represented by entering <SUB><SUB> 1. The characters for Functions 2, 3, and 4 are represented in the same way. If you want to produce a square symbol, specify a height magnification of 1 in advanced mode. A square symbol is specified by a height magnification of 250 in emulation mode. c10

Select Code 49.

In emulation mode, <SUB> 1 is used to represent the Function 1 character. In advanced mode, <SUB><SUB> 1 is used to represent the Function 1 character. The characters for Functions 2 and 3 are represented in the same way. If you want to produce a square symbol, specify a height magnification of 1 in advanced mode. A square symbol is specified by a height magnification of 250 in emulation mode. Only alphanumeric (0) and numeric (2) modes are supported.

7-47

Page 218

Helvitica condensed 9 pt italic

Co d e

39

18 pt

4100 Bar Code Label Printer User's Manual c11

Select POSTNET.

FrGoth

POSTNET uses the height (“h”) and width (“w”) commands in the same way as a font. Other symbologies use “h” to specify the bar height and “w” to specify the narrow bar width. POSTNET uses “h” and “w” to magnify the base character cell. Each character cell is 13 dots high by 22 dots wide. The default width and height magnification for POSTNET is 2 by 2, resulting in a symbology sized according to the POSTNET specification. c16{,m1}{,m2}

Selects HIBC Code 128. Default for m1 is 0. m2 is the field identifier.

The next three modifiers conform to Supplier Standard: c16,0

Select HIBC Code 128. Primary format.

c16,1

Select HIBC Code 128. Alternate primary format.

c16,2,m2

Select HIBC Code 128. Secondary format. The linkage character comes from m2, which is the field identifier.

The next four modifiers conform to Provider Standard: c16,3

Select HIBC Code 128. Single format.

c16,4

Select HIBC Code 128. First data format.

c16,5,m2

Select HIBC Code 128. Second data format. The linkage character comes from m2, which is the field identifier.

c16,6

Select HIBC Code 128. Multiple data format.

Bar Code Field, Create or Edit Purpose:

Use this command to edit or create a bar code field n.

Default:

n=0

Syntax:

B{n}{,name}; n values can range between 0 and 199. ,name is optional. The field can be up to 8 ASCII characters, but cannot start with a numeric character.

7-48

Page 219

Helvitica condensed 9 pt italic

Co d e

39

18 pt Printer Commands

Notes:

7

Parameters for the default field are: Field origin Field direction Bar code Check digits Prefix Ratio Interpretive Height magnification Width magnification Data origin Data length

0,0 0 degrees Code 39 Disabled None 3 to 1 Disabled 50 1 Print mode 20

Bitmap Cell Height for Graphic or UDF, Define Purpose:

Defines the height of a graphic or user-defined font.

Default:

n=1

Syntax:

y{n}

Bitmap fonts and graphics n values can range between 1 and 600 (1 and 800 with expansion RAM). n is the number of rows for a graphic or font (bitmap). For outline fonts, n represents the height of the base character in number of dots. Notes:

An error code (52) is generated for an invalid height.

Bitmap Cell Width for Graphic or UDF, Define Purpose:

Defines the maximum width for a graphic or any character in a font. Each character has a width within this amount, which should be at least as wide as the widest character in the font. n is the number of columns for the UDC, bit-mapped or user-defined font. For outline fonts, n represents the width of the base character in number of dots.

Default:

n=1

Bitmap fonts and graphics

7-49

Page 220

Helvitica condensed 9 pt italic

Co d e

39

18 pt

4100 Bar Code Label Printer User's Manual Syntax:

x{n}

FrGoth n values can range between 1 and 599. Notes:

An error code (52) is generated if the width is invalid.

Bitmap User-Defined Font, Clear or Define Purpose:

Use this command to clear or create a user-defined bitmapped font set. n is the font ID number.

Syntax:

T{n}{,name}; Values for n can range from 3 to 6 and 8 to 19. ,name is an optional field. The field can be up to 8 ASCII characters.

Notes:

If font set n has already been defined, all previous characters in the font set are erased. An existing font cannot be edited, only recreated. To change any characters, the entire font set must be transmitted.

Border Around Human-Readable Text, Define Purpose:

Defines a border around a human-readable field.

Default:

n=0

Syntax:

b{n};

No borders (black letters)

n values range from 0 to 199. Notes:

When n is greater than 0, the field prints white letters with an n dot size border surrounding the field.

Box Field, Create or Edit Purpose:

Use this command to access or create a box field n.

Default:

n=0

Syntax:

W{n}{,name}; n values can range between 0 and 199. ,name is an optional field. The field can be up to 8 ASCII characters, but cannot start with a numeric character.

7-50