The text of a manual · part 17 of 29
4100 Bar Code Label Printer User's Manual, pages 161 to 170
Pages 161 to 170 of 282
The original document is the PDF (1.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 4100
Page 161
Helvitica condensed 9 pt italic
Co d e
39
18 pt
Designing Labels and Using Commands
6
Data for Example 1 <STX><ESC>E3<CAN><ETX> 1246<CR><ETX> Fr<STX>LOC Goth <STX>3666<ETX> <STX><ETB><ETX> The <STX> and <ETX> characters are used simply to mark the beginnings and ends of the command strings. The other characters are described in the table that follows. Command
Description
<ESC>C
Operate in Advanced mode.
<ESC>P
Enter Programming mode.
E3;
Erase anything previously stored as format 3.
F3;
Access format 3.
H0;
Designate field 0 as a human-readable field.
o81,100;
Set the origin at grid coordinates 81,100.
f0;
Set the field rotation to 0, which is unrotated and horizontal.
c2;
Select internal font 2.
d0,16;
Determine that data will be sent during print mode and will be a maximum of 16 characters long.
h4;
Sets the height magnification factor to 4. (Four times the normal height).
w4;
Set the field width magnification factor to 4. (Four times the normal width).
H1;
Define field 1 as a human-readable field.
o81,200;
Set the field origin at coordinates 81, 200.
f0;
Set the rotation factor of the field to 0.
c2;
Select internal font 2.
d3,Warehouse Part # 3666;
Assign the constant value “Warehouse Part # 3666” to the field.
h3;
Set the field height magnification factor to 3. (Three times the normal height).
w3;
Set the field width magnification factor to 3. (Three times the normal width.)
B2;
Define field 2 as a bar code field.
o81,300;
Set the origin at coordinates 81,300.
f0;
Set the field rotation to 0 (unrotated).
c0,1;
Select Code 39, the printer enters a check digit.
h75;
The field height is 75 dots high.
6-29
Page 162
Helvitica condensed 9 pt italic
Co d e
39
18 pt
4100 Bar Code Label Printer User's Manual Command
Description w1;
The narrowest element is 1 dot wide.
i0;
No human readable interpretive field will print below the bar code.
d0,11;
Data from Print mode, 11 characters long maximum.
p@;
The bar code field will not have a prefix.
L3;
Define field 3 as a line field.
o81,400;
Set the field origin at coordinates 81, 400.
f0;
Define the field rotation as horizontal (no rotation).
l800;
Define the line to be 800 dots long.
w6;
Determine the line will be 6 dots thick.
R
Exit Programming mode and enter Print mode.
<ESC>E3
Access format 3.
<CAN>
Clear all host-entered data for the current format and expect data for the lowest numbered field in the format.
LOC 1246<CR>
Data for the first field in the format. (Go to next field.)
3666
Data for the bar code field.
<ETB>
Print the label.
6-30
Page 163
Helvitica condensed 9 pt italic
39
18 pt
Designing Labels and Using Commands
6
Example 2 format example on this page is a complex label designed to demonstrate the FrThe Goth different types of data that can be printed by your 4100 printer. This example contains human-readable fields, a bar code field, line fields, a box field, and the diamond graphic field defined earlier in this section.
Cat. No.
432-3221
S i z e
3 4
1 Lot 23455 2629333
Co d e
St. Qty.
100
DUPLEX ANGLE CONNECTOR
- For Flexible Steel Conduit and .375" - .625" Diameter Armored and Nonmetallic Sheath Cables - For Smooth or Interlocking Sheath Metal Clad Cables .375" - .675" Dia. (UL only)
ACE CORP. ADDRESS 3010 FICTION USA
*307,91751* *307 91751*
4100-02
Graphic for Example 2 Download the one bit per byte graphic diamond graphic explained in “Downloading One Bit Per Byte Graphics” earlier in this chapter.
6-31
Page 164
Helvitica condensed 9 pt italic
Co d e
39
18 pt
4100 Bar Code Label Printer User's Manual Format for Example 2 <STX><ESC>C<ETX> <STX><ESC>P<ETX> <STX>E5;F5;<ETX> <STX>H0;o35,40;c21;d3,Cat.;k10;<ETX> <STX>H1;o35,70;c21;d3,No.;k10;<ETX> <STX>H2;o165,0;c21;d3,432-3221;k40;<ETX> <STX>H3;o785,40;c21;d3,Std.;k10;<ETX> <STX>H4;o785,70;c21;d3,Qty.;k10;<ETX> <STX>H5;o915,0;c21;d3,100;k40;<ETX> <STX>L6;o740,10;f3;l130;w8;<ETX> <STX>L7;o25,140;l1130;w8;<ETX> <STX>H8;o30,165;c21;f3;r1;d3,Size;k10;<ETX> <STX>H9;o80,170;c0;d3,1 ";k30;<ETX> <STX>H10;o150,165;f3;r1;c0;d3,3/4;h3;w7;<ETX> <STX>L11;o300,140;f3;l130;w8;<ETX> <STX>L12;o25,270;l275;w8;<ETX> <STX>H13;o60,560;f1;c0;d0,20;h3;w2;<ETX> <STX>L14;o140,270;f3;l310;w8;<ETX> <STX>H15;o360,120;c22;d3,DUPLEX ANGLE CONNECTOR;h3;w1;<ETX> <STX>H16;o170,320;c21;d3,- For Flexible Steel Conduit and .375" - .625";k12;<ETX> <STX>H17;o212,375;c21;d3,Diameter Armored and Nonmetallic Sheath Cables;k12;<ETX> <STX>H18;o170,450;c21;d3,- For Smooth or Interlocking Sheath Metal Clad;k12;<ETX> <STX>H19;o212,505;c21;d3,Cables .375" - .675" Dia. (UL only);k12;<ETX> <STX>L20;o25,580;l1130;w8;<ETX> <STX>U21;o40,610;c2;h9;w9;<ETX> <STX>H22;o210,600;c21;d3,ACE CORP.;k20;<ETX> <STX>H23;o210,670;c21;d3,ADDRESS 3010;k10;<ETX> <STX>H24;o210,710;c21;d3,FICTION USA;k10;<ETX> <STX>B25;o685,615;c0,0;d0,20;i1;h100;p@;<ETX> <STX>I25;h2;w2;<ETX> <STX>L26;o590,580;f3;l185;w8;<ETX> <STX>W27;o015,000;w10;l1150;h775;<ETX> <STX>R<ETX> Data for Example 2 <STX><ESC>E5<CAN><ETX> <STX>Lot 23455 2629333<CR>307 91747<CR><ESC>I2<ETX> <STX><RS>5<ETB><ETX> 6-32
Page 165
Helvitica condensed 9 pt italic
Co d e
39
18 pt
Designing Labels and Using Commands
6
The <ETX> and <STX> characters are used to mark the beginnings and ends of the command strings. The other characters are explained in the following table. Command
Fr Goth
Description
<ESC>C
Operate in Advanced mode.
<ESC>P
Enter Programming mode.
E5;F5;
Erases anything previously stored as format 5 and accesses the location for format 5.
H0;
Defines field zero as a human-readable field.
o35,40;
Sets the origin of field zero at coordinates (35,40).
c21;
Sets the font for field zero to font 21.
d3,Cat.;
Sets the data for field zero to have the constant value: Cat.
k10;
Sets the point size to 10.
H1;
Defines field one as a human-readable field.
o35,70;
Sets the origin of field 1 at coordinates (35,70).
c21;
Sets the fonts for field 1 to font 21.
d3,No.;
Set the data for field 1 the constant value: No.
k10;
Sets the point size to 10.
H2;
Defines field 2 as a human-readable field.
o165,0;
Sets the origin of field 2 at (165,0).
c21;
Sets the font of field 2 to font 21.
d3,432-3221;
Sets the constant data for field 2.
k40;
Set the point size to 40.
H3;
Defines field 3 as a human-readable field.
o785,40;
Sets the origin of field 3 at (785,40).
c21;
Sets the font for field 3 to font 21.
d3,std.;
Defines constant data for field 3.
k10;
Sets the point size to 10.
H4;
Defines field 4 as a human-readable field.
o785,70;
Sets the origin of field 4 at (785,70).
c21;
Sets the font for field 4 to font 21.
6-33
Page 166
Helvitica condensed 9 pt italic
Co d e
39
18 pt
4100 Bar Code Label Printer User's Manual Command
Description d3,Qty.;
Defines constant data for field 4.
k10;
Sets the point size to 10.
H5;
Defines field 5 as a human-readable field.
o915,0;
Sets the origin of field 5 at (915,0).
c21;
Sets the font for field 5 to font 21.
d3,100;
Defines the constant data for field 5.
k40;
Sets the point size to 40.
L6;
Defines field 6 as a line field.
o740,10;
Sets the origin for field 6 at (740,10).
f3;
Rotates field 6 270 degrees counterclockwise around the field origin.
l130;
Sets the length of the line in field 6 to 130 dots.
w8;
Sets the width of field 6 to eight times its actual width.
L7;
Defines field 7 as a line.
o25,140;
Sets the origin for field 7 at (25,140).
l1130;
Sets the length of the line in field 7 to 1130 dots.
w8;
Sets the line width to 8 dots.
H8;
Defines field 8 as a human-readable field.
o30,165;
Sets the origin of field 8 at (30,165).
c21;
Defines the font for field 8 as font 21.
f3;
Rotates field 8 270 degrees counterclockwise around the origin.
r1;
Rotates the characters in field 8 90 degrees counterclockwise.
d3,Size;
Defines the constant data for field 8.
k10;
Sets the point size to 10.
H9;
Defines field 9 as a human-readable field.
o80,170;
Sets the origin of field 9 at (80,170).
c0;
Defines the font for field 9 as font 0.
d3,1 ";
Defines constant data for field 9.
k30;
Sets the point size to 30.
H10;
Defines field 10 as a human-readable field.
o150,165;
Sets the origin for field 10 at (150,165).
f3;
Rotates field 10 270 degrees counterclockwise around the origin.
r1;
Rotates the characters in field 10 90 degrees counterclockwise.
c0;
Sets the font for field 10 to be font 0.
6-34
Page 167
Helvitica condensed 9 pt italic
Co d e
39
Command pt
Designing Labels and Using Commands
6
Description Defines constant data for field 10.
d3,3/4; h3;
18
Fr Goth
Sets the height to three times the original size.
w7;
Sets the width to seven times the original size.
L11;
Defines field 11 as a line field.
o300,140;
Sets the origin for field 11 at (300,140).
f3;
Rotates field 11 270 degrees counterclockwise around the origin.
l130;
Sets the length of the line in field 11 to 130 dots.
w8;
Sets the width to 8 dots.
L12;
Defines field 12 as a line field.
o25,270;
Sets the origin of field 12 at (25,270).
l275;
Sets the length of the line in field 12 to 275 dots.
w8;
Sets the width of field 12 to 8 dots.
H13;
Defines field 13 as a human-readable field.
o60,560;
Sets the origin of field 13 at (60,560).
f1;
Rotates field 13 90 degrees around the origin 25.
c0;
Determines that field 13 prints in font 0.
d0,20;
Specifies that data for field 13 will be entered during Print mode and that the data will be a maximum of 20 characters long.
h3;
Sets the height of field 13 to three times the actual size.
w2;
Sets the width of field 13 to two times the actual size.
L14;
Defines field 14 as a line field.
o140,270;
Sets the origin of field 14 at (140,270).
f3;
Rotates field 14 270 degrees counterclockwise around the origin.
l310;
Sets the length of the line in field 14 to 310 dots.
w8;
Sets the width of field 14 to 8 dots.
H15;
Defines field 15 as a human-readable field.
o360,120;
Sets the origin of field 15 at (360,120).
c22;
Determines that the field prints in font 22.
d3,DUPLEX ANGLE CONNECTOR;
Defines constant data for field 15.
h3;
Sets the height to three times the original size.
w1;
Sets the width to original size.
H16;
Defines field 16 as a human-readable field.
6-35
Page 168
Helvitica condensed 9 pt italic
Co d e
39
4100 Bar Code Label Printer User's Manual Command
Description o170,320;
Sets the origin for field 16 at (170,320).
c21;
Determines that field 16 prints in font 21.
d3,-For Flexible Steel and
Defines the constant data for field 16.
Conduit and .375" - .625"; k12;
Sets the point size to 12.
H17;
Defines field 17 as a human-readable field.
o212,375;
Sets the origin of field 17 at (212,375).
c21;
Determines that field 17 prints in font 21.
d3,Diameter Armored and Nonmetallic Sheath Cables;
Defines constant data for field 17.
k12;
Sets the point size to 12.
H18;
Defines field 18 as a human-readable field.
o170,450;
Sets the origin of field 18 at (170,450).
c21;
Determines that field 18 prints in font 21.
d3,-For Smooth or Interlock- Defines constant data for field 18. ing Sheath Metal Clad; k12;
Sets the point size to 12.
H19;
Defines field 19 as a human-readable field.
o212,505;
Sets the origin of field 19 at (212,505).
c21;
Determines that field 19 prints in font 21.
d3,Cables .3765: .675" Dia. (UL only);
Defines the constant data for field 19.
k12;
Sets the point size to 12.
L20;
Defines field 20 as a line field.
o25,580;
Sets the origin of field 20 at (25,580).
l1130;
Sets the length of the line in field 20 to 1130 dots.
w8;
Sets the width to 8 dots.
U21;
Defines field 21 as a graphic field.
o40,610;
Sets the origin of field 21 at (40,610).
c2;
Determines that field 21 prints in UDC 2.
h9;
Sets the height to 9 times the original size.
w9;
Sets the width to 9 times the original size.
H22;
Defines field 22 as a human-readable field.
o210,600;
Sets the origin of field 22 at (210,600).
6-36
18 pt
Page 169
Helvitica condensed 9 pt italic
Co d e
39
Command pt
Designing Labels and Using Commands
6
Description Determines that field 22 prints in font 21.
c21; d3,ACE CORP.;
18
Fr Goth
Defines constant data for field 22.
k20;
Sets the point size to 20.
H23;
Defines field 23 as a human-readable field.
o210,670;
Sets the origin of field 23 at (210,670).
c21;
Determines that field 23 prints in font 21.
d3,ADDRESS 3010;
Defines constant data for field 23.
k10;
Sets the point size to 10.
H24;
Defines field 24 as a human-readable field.
o210,710;
Sets the origin of field 24 at (210,710).
c21;
Determines that field 24 prints in font 21.
d3,FICTION USA;
Defines constant data for field 24.
k10;
Sets the point size to 10.
B25;
Defines field 25 as a bar code field.
o685,615;
Sets the origin of field 25 at (685,615).
c0,0;
Sets the bar code font to Code 39 with no check digit.
d0,20;
Determines that the data for field 25 is entered during print mode and its maximum length is 20 characters.
i1;
Determines that an interpretation of the bar code prints with start and stop characters included.
h100;
Determines that the bar code height is 100 dots.
p@;
Clears all prefixes from the bar code field.
I25;
Defines field 25 as an interpretive field.
h2;
Sets the height to two times the original size.
w2;
Sets the width to two times the original size.
L26;
Defines field 26 as a line field.
o590,580;
Sets the origin of field 26 at (590,580).
f3;
Rotates field 26 270 degrees counterclockwise around the field origin.
l175;
Sets the length of the line in field 26 to 175 dots.
w8;
Sets the width of field 26 to 8 dots.
W27;
Defines field 27 as a box field.
o015,000;
Sets the origin of field 27 at (015,000).
w10;
Sets the width of field 27 to 10 dots.
6-37
Page 170
Helvitica condensed 9 pt italic
Co d e
39
18 pt
4100 Bar Code Label Printer User's Manual Command
Description
I1150;
Sets the length of field 27 to 1150 dots.
h775
Sets the height to 775 times the original size.
R
Sets the printer in print mode.
<ESC>E5
Accesses format five from the printer memory.
<CAN>
Clears all host entered data for the current format and sets the field pointer to the lowest numbered data-entry field.
Lot 23455 2629333<CR>
This is the data intended for the first data-entry field. <CR> instructs the printer to go to the next data-entry field.
<FS>
Field separator
307 91747
This is the data intended for the next data-entry field.
<FS>
Field separator.
<ESC>I2
Sets the field increment value to increment by 2.
<RS>5
Tells the printer to print 5 labels.
<ETB>
Tells the printer to print the labels.
6-38