Page 47

*1234*

Designing Bar Code Labels

3

Bar Code Fields You can print bar codes in any of the symbologies listed below. See Chapter 7, “IPL Command Reference,” for a complete list of commands to select the appropriate bar code symbology. “Commands Listed by Task” in Chapter 6 lists the command options available for editing bar code fields. These symbologies are available: Codabar Code 2 of 5 Code 11 Code 16K Code 39 Code 49 Code 93 Code 128 Code One

Data Matrix HIBC Interleaved 2 of 5 Maxicode MicroPDF417 QR Code PDF417 POSTNET UPC/EAN

Human-Readable Fields You can print human-readable fields in any one of the printer’s internal fonts or userdefined fonts. The printer contains several resident bitmap fonts in a range of sizes and styles. You can change the size of the font character by using the width and height magnification or by using the pitch or point-size commands. The fonts themselves remain unchanged. The font character charts in Appendix B, “Character Sets,” illustrate the complete character set for each font. The printer supports nine different international character sets for each command set mode. In Emulation mode, the international character substitution is compatible with Intermec 8636/8646 printers. In Advanced mode, the substitution complies with the ISO standards. The printer may also contain character sets for IBM translation and code pages. The internal bitmap fonts of the printer include: •

Standard bitmap fonts measured in dots

•

Bitmap fonts recognized by optical character recognition (OCR) programs

•

Bitmap fonts measured in point sizes

•

Outline fonts

•

Bitmap monospaced fonts

3-9

Page 48

IPL Programming Reference Manual*1234*

Line and Box Fields Use the command set (see Chapter 7, “IPL Command Reference”) to define line or box fields on a label. You can use the commands to determine whether a box or line appears vertically or horizontally and to set the line length and thickness. The following example uses vertical and horizontal lines to separate fields on a label and uses a box field to make a label border. This format uses bold text to highlight the lines that contain line or box fields. This label format prints the label shown on the next page.

Lines and Boxes Format <STX><ESC>C0<ETX> <STX><ESC>P;<ETX> <STX>E4;F4,DEMO 4;<ETX> <STX>L1;o11,447;f0;l1207;w4;<ETX> <STX>L2;o11,285;f0;l1207;w4;<ETX> <STX>W3;o11,0;f0;l1207;h802;w4;<ETX> <STX>B4;o658,650;f0;h102;w2;c0,0;i1;r1;d0,11;<ETX> <STX>I4;o658,752;f0;h1;w1;c20;r0;b0;<ETX> <STX>B5;o87,650;f0;h102;w2;c0,0;i1;r1;d0,11;<ETX> <STX>I5;o87,752;f0;h1;w1;c20;r0;b0;<ETX> <STX>H6;o34,183;f0;h1;w1;c22;r0;b0;d0,17;<ETX> <STX>H7;o35,143;f0;h1;w1;c21;r0;b0;d3,BASIS WT. 39-4838;<ETX> <STX>H8;o389,305;f0;h1;w1;c21;r0;b0;d3,ROLLS;<ETX> <STX>H9;o40,305;f0;h1;w1;c21;r0;b0;d3,ROLL WIDTH;<ETX> <STX>L10;o11,609;f0;l1207;w4;<ETX> <STX>H12;o1022,508;f0;h1;w1;c22;r0;b0;d0,7;<ETX> <STX>H13;o1022,467;f0;h1;w1;c21;r0;b0;d3,WEIGHT;<ETX> <STX>H14;o539,508;f0;h1;w1;c22;r0;b0;d0,11;<ETX> <STX>H15;o539,467;f0;h1;w1;c21;r0;b0;d3,LOCATION;<ETX> <STX>H16;o42,508;f0;h1;w1;c22;r0;b0;d0,15;<ETX> <STX>H17;o43,467;f0;h1;w1;c21;r0;b0;d3,CUSTOMER ORDER NUMBER;<ETX> <STX>H18;o840,346;f0;h1;w1;c22;r0;b0;d0,13;<ETX> <STX>H19;o840,305;f0;h1;w1;c21;r0;b0;d3,ORDER ITEM NUMBER;<ETX> <STX>H20;o389,346;f0;h1;w1;c22;r0;b0;d0,7;<ETX> <STX>H21;o34,346;f0;h1;w1;c22;r0;b0;d0,11;<ETX> <STX>H22;o747,183;f0;h1;w1;c22;r0;b0;d0,15;<ETX> <STX>H23;o743,143;f0;h1;w1;c21;r0;b0;d3,GRADE DESCRIPTION;<ETX> <STX>H24;o13,0;f0;h51;w34;c25;r0;b3;d3, SHIPPING LABEL <STX>R<ETX> <STX><ESC>E4<CAN><ETX> <STX><ESC>F4<LF>INTERMEC<ETX> <STX><ESC>F5<LF>372181192<ETX> <STX><ESC>F6<LF>38448379237<ETX> <STX><ESC>F12<LF>230<ETX> <STX><ESC>F14<LF>3839494<ETX> <STX><ESC>F16<LF>372181192<ETX> <STX><ESC>F18<LF>234-LOFT<ETX> <STX><ESC>F20<LF>12<ETX> <STX><ESC>F21<LF>338438<ETX> <STX><ESC>F22<LF>A-PLUS QTY<ETX> <STX><ETB><FF><ETX>

3-10

;<ETX>

Page 49

*1234*

3

Designing Bar Code Labels

Lines and Boxes Label

SHIPPING LABEL BASIS WT. 39-4838

GRADE DESCRIPTION

38448379237

A - PLUS QTY

ROLL WIDTH

ROLLS

ORDER ITEM NUMBER

338438

12

234 - LOFT

CUSTOMER ORDER NUMBER

LOCATION

WEIGHT

372181192

3839494

230

INTERMEC

372181192

IPL006.eps

Graphic Fields You must define a graphic field if you want to print a graphic image on a label. Before you can use this field, you need to download the graphic to the printer. Once you download the graphic, you can use it in any format. Use the PrintSet printer installation software to easily download graphics to the printer. PrintSet automatically converts the graphic into a six bits per byte format that your printer can understand. If you are using third-party label-generation software, it converts your graphic file to a UDC format that the printer can interpret and downloads it to the printer. If you want to design your own graphic, refer to “Creating User-Defined Bitmap Graphics” in Appendix C. You must send graphics as either one bit per byte or six bits per byte bitmap images. The maximum size that you can define a graphic to be is limited by the capacity of your printer. Due to message length constraints, you must design large graphics in the six bits per byte format. You can use Direct Graphics mode to reduce the time it takes to download and print an image. For more information on direct graphics, see Appendix E, “Using Direct Graphics Mode.”

3-11

Page 50

IPL Programming Reference Manual*1234*

Editing Label Formats and Working With Fields In addition to understanding the different types of printable fields on the printer, you need to know how to arrange them to define or change the format of a label. The following sections use examples to describe the commands that position, size, rotate, and edit label fields. For a complete list of all programming commands, see Chapter 6, “How to Find IPL Commands in This Manual.” Whenever you create a format, the printer automatically creates a human-readable field zero (H0) along with it. The printer creates the H0 field with all field parameters set to the default setting. You can only delete field zero after you create one or more other fields. You cannot delete the last field in a format. The defaults for the H0 field are: Command

Definition o0,0;

Field origin is 0,0.

f0;

Field direction is horizontal with respect to the label motion from printer.

h1;

Field height magnification is one.

w1;

Field width magnification is one.

c2;

Selects the 10 x 14 standard font.

b0;

Selects no border around human-readable field.

r0;

Selects horizontal orientation of characters.

d0,30;

You enter variable data in Print mode. The maximum number of characters you can enter into this field is 30.

When creating a new format field, it is not possible to specify field zero as anything other than human-readable field zero (H0) without creating another field first. For example, you cannot make field zero a bar code field by doing the following: <STX><ESC>P;E1;F1;B0;<ETX>

3-12

Page 51

*1234*

Designing Bar Code Labels

3

To make field zero a bar code field, you have to delete human-readable field 0 and then define bar code field 0. To do this, you must create a temporary field (L39) before you delete human-readable field zero (H0): <STX><ESC>P;E1;F1;L39;D0;B0;D39;<ETX>

This table describes each command in the string: Command

Definition

<ESC>P;

Enters Program mode

E1;

Erases format 1

F1;

Creates format 1

L39;

Creates line field (temporary field)

D0;

Deletes field zero

B0;

Creates bar code field zero

D39;

Deletes the temporary line field

When numbering the fields in a format, it is important to remember to give every field a different number. Never use a field number more than once. You can have up to 200 fields numbering from 0 to 199. The importance of field numbering comes into play when you are in Print mode and are entering data into the label format. At this point, you can only identify the fields by a number, not by the type of field. Each bar code field can have an interpretive field associated with it. For example, bar code field B33 would have an interpretive field I33. All interpretive fields use up a field location, starting from the top of the field directory; if B33 is the first bar code field with interpretive text, then field I33 would use location 199. You can see how the printer uses the fields internally by uploading the format and examining where the interpretives appear. For help, see the Format, Transmit command in Chapter 7, “IPL Command Reference.” If you need to use more fields than IPL can accommodate in a single format (because of interpretive fields), you can use pages to combine several formats on one label. Also keep in mind that you enter data into fields according to their numeric value if you use a <CR> to separate the data. In other words, the first string of data you enter goes into the lowest numbered field, the second string of data you enter goes into the next lowest numbered field, and so on.

3-13

Page 52

IPL Programming Reference Manual*1234*

Editing Existing Fields If you make a mistake in a label format, you may not have to download the entire format again depending on the severity of the mistake. You can change a specific field in a format by sending a command in Program mode. You can modify just the incorrect format fields instead of having to download the entire format again. When the printer is in Program mode, it uses a field pointer to point to the field to be modified. The pointer continues to point to the most recently selected field until you select a different format or field. Use the following format as an example. Assume that you have downloaded the following format to the printer: Commands

Description

<STX><ESC>C<ETX>

Selects Advanced mode

<STX><ESC>P<ETX>

Enters Program mode

<STX>E3;F3;<ETX>

Erases format 3, Creates format 3

<STX>H0;o80,100;f0;c0;d0,16;h1;w1;<ETX>

Creates field H0

<STX>H1;o80,120;f0;c0;d0,16;h1;w1;<ETX>

Creates field H1

<STX>H2;o80,150;f0;c2;d0,14;h1;w1;<ETX>

Creates field H2

<STX>H3;o80,190;f0;c2;d0,16;h1;w1;<ETX>

Creates field H3

<STX>B4;o80,0;f0;c0,1;h50;w1;d0,11;i0;p@;<ETX>

Creates field B3

<STX>R;<ETX>

Saves and exits to Print mode

3-14

Page 53

*1234*

Designing Bar Code Labels

3

To change the height and width of field 3 to 2 dots, download this command string: <STX><ESC>P;F3;H3;h2;w2;R;<ETX>

The following table describes each command in this string: Command

Description

<ESC>P;

Enters Program mode

F3;

Accesses format number 3 from memory

H3;

Accesses field 3 h2;

Sets the height to 2 dots w2;

Sets the width to 2 dots

R;

Returns to Print mode

Note: The <STX> and <ETX> commands mark the beginning and end of a message. The semicolon (;) is the command terminator. Except for the last command in a message, all commands in Program mode must end with this terminator.

Deleting Fields It is possible to delete any field from a format except for the last field. Use the following command string to delete field 3 from format 4. <STX><ESC>P;F4;D3;R;<ETX> The following table describes each command in this string: Command

Description

<ESC>P;

Enters Program mode

F4;

Accesses format 4

D3;

Deletes field 3

R;

Returns to Print mode

Positioning Fields Using the IPL command language to position fields is the trickiest part of designing labels. Since you cannot tell exactly how the field looks until it prints, you may need to make several test prints before you get the field positioned correctly. For all types of fields, determine the print position by defining the coordinates of the upper left corner of the unrotated field.

3-15

Page 54

IPL Programming Reference Manual*1234* The field origin is the upper left corner of an unrotated field. To define the coordinates of the field origin, use the origin command (oX,Y) where o is the command that specifies origin, X is the distance from the left side of the label, and Y is the distance from the top of the label. Note: On the 4400 and 7421 printers, be sure to use the label width command to set the printer for the correct label width; otherwise, the Y origins will be incorrect. The X and Y coordinates of the field origin use dots as their form of measurement. There are 203 dots per inch or 8 dots per millimeter. Note: The 3400e with 400 dots per inch, 3240, and 3440 printers have 406 dots per inch or 16 dots per millimeter. The 4X30 printers have 300 dots per inch or 12 dots per millimeter. To position a field to print approximately 0.25 inch from the left side and 0.5 inch from the top of your label, the origin command is o51,102.

D A HR Field

Second HR Field

B

*BCFIELD*

*BC FIELD*

C A = o51, 102 B = o51, 203

C = o51, 305 D = o355, 102

IPL007.eps

Note: If you are operating your printer in Emulation mode, the dot sizes are doubled (101 dots per inch or 4 dots per millimeter), so the origin for 1 inch from the top of the label and 0.5 inch from the left side is o25,51.

3-16