Page 167
HelvC NugFont
Configuration Commands C d 39
7
Printhead Loading Mode, Select Purpose:
Selects the printhead loading mode that affects how the whole image prints on the label. Mirror Printing mode reverses the order in which data loads into the printhead. Inverse Printing mode causes all pixels that are white to invert to black and vice versa.
Syntax:
<SI>hn[,m]
Printers:
Note:
Printer
Defaults
Values for n
Values for ,m
3400C 3400D 3400e n=0 ,m = 0
0 - Selects normal printing 1 - Selects Mirror Printing mode
0 - Selects normal printing 1 - Selects Inverse Printing mode
3440 n=0 ,m = 0
0 - Selects normal printing 1 - Selects Mirror Printing mode
0 - Selects normal printing 1 - Selects Inverse Printing mode
44X0 n=0 ,m = 0
0 - Selects normal printing 1 - Selects Mirror Printing mode
0 - Selects normal printing 1 - Selects Inverse Printing mode
7421 n=0 ,m = 0
0 - Selects normal printing 1 - Selects Mirror Printing mode
0 - Selects normal printing 1 - Selects Inverse Printing mode
EasyCoder F4 n=0 ,m = 0
0 - Selects normal printing 1 - Selects Mirror Printing mode
0 - Selects normal printing 1 - Selects Inverse Printing mode
The printhead is not under warranty if you use Inverse Printing mode for batch printing. Intermec does not recommend using Inverse Printing mode for batch printing. For best results with Inverse Printing mode, use a maximum print density of 35 percent.
7-61
Page 168
IPL Programming Reference Manual
Printhead Pressure, Set Purpose:
Compensates for variations in the thickness of label stock.
Syntax:
<SI>Hn
Printers: Printer
Default
Values for n
Notes
4400 n=0
0 - Low printhead pressure 1 - High printhead pressure
If your labels are slipping, or you notice that the pressure is too light, try changing the pressure to the other setting.
Printhead Test Parameters, Set Purpose:
Sets the printhead test parameters.
Syntax:
<SI>Un[,m][,p][,q] where: n determines whether printing continues if the printhead test sends a warning. ,m is the positive threshold of the percentage of the allowable deviation in resistance. ,p is the negative threshold of the percentage of the allowable deviation in resistance. ,q specifies how often (in terms of the number of labels printed) to automatically run the printhead resistance test.
Printers:
7-62
Printer
Defaults
Values for n ,m ,p and ,q
Notes
4400 n=0 m = 45 p = 45 q=0 n - 0 Printing continues when warning occurs n - 1 Printing stops when warning occurs
This command is effective upon execution.
,m
A number from 45 to 10
,p
A number from 45 to 10 q
A number from 0 to 9999. Setting q = 0 disables the test.
Page 169
HelvC NugFont
Configuration Commands C d 39
7
Ribbon Save Zones, Set Purpose:
Defines the start and stop points of a ribbon save zone within the label. This command does not enable interlabel ribbon save.
Syntax:
<SI>Zn[,m] n and ,m are the zone start and zone stop distances, in dot increments, from the detected front of the label. The difference between m and n depends on the speed (number of ips) at which you are printing. Also, m must be bigger than n by at least 100, or the command will be ignored.
Printers: Printer
Notes
4100
The ribbon save option must be installed or the printer will ignore this command. Setting a ribbon save zone enables ribbon save. Entering no ribbon save zones clears all ribbon save zones within this label. If only one parameter is entered, the command is ignored. The maximum number of zones possible on one label is 10. This command is buffered up and becomes effective upon execution.
Self-Strip, Enable or Disable Purpose:
Turns the self-strip (label taken sensor) option on or off.
Syntax:
<SI>tn
Printers: Printer
Default
Values for n
3240 n=0
0 - disabled 1 - enabled
3400 n=0
0 - disabled 1 - enabled
3440 n=0
0 - disabled 1 - enabled
3600 n=0
0 - disabled 1 - enabled
7-63
Page 170
IPL Programming Reference Manual
Self-Strip, Enable or Disable (continued) Printer
Default
Values for n
Notes
4100
N/A
N/A
The 4100 printer ignores this command; however, you can enable self-strip by using the DIP switches.
4400 n=0
0 - disabled 1 - enabled
You must install the self-strip option from the control panel before you can enable or disable the label taken sensor.
44X0 n=0
0 - disabled 1 - enabled
4X30 n=0
0 - disabled 1 - enabled
7421 n=0
0 - disabled 1 - enabled
EasyCoder F4 n=0
0 - disabled 1 - enabled
Serial Port Configuration, Set See Communication Port Configuration, Set.
Takeup Motor Torque, Increase Purpose:
Increases the takeup motor torque from 0 to 50% above the default value.
Syntax:
<SI>bn
Printers:
7-64
Printer
Default
Values for n
44X0 n=0
0 to 50%
Page 171
HelvC NugFont
Program Mode Commands C d 39
7
Top of Form, Set Purpose:
Sets the top of form (left margin or start print point) to n, which is the distance in 5 mil increments from the label origin to its leading edge.
Syntax:
<SI>Fn
Printers: Printer
Default
Values for n
Notes
All n = 20
-10 to 4000 (in 5 mil increments)
The negative values for n let you decrease the margin and print closer to the edge of the label.
Program Mode Commands You can use Program mode commands to design label formats and to download userdefined fonts and graphics. When creating or editing formats, the printer uses a field pointer to designate the field you are going to modify when the printer is in Program mode. To download commands in Program mode, you must specify the field you want to change. If you do not select a field, the pointer continues to point to the last selected field until you select a different format or field. New formats contain a default human-readable field numbered H0. New pages do not contain a default format. Program mode commands are effective when the printer is in Program mode. You can switch the printer to Program mode with this command: <STX><ESC>P<ETX> For help downloading Program mode commands to the printer, see “Sending IPL Commands to the Printer” in Chapter 1. Note: You must precede each string of commands with the start of message character <STX> and follow it with the end of message character <ETX>. The semicolon (;) is the command terminator. All commands in Program mode must end with this terminator except the last command in a message. The printer ignores parentheses [( )] and <LF> characters.
Bar Code, Select Type Purpose:
Selects a symbology for a bar code field.
Syntax:
cn[,m1][,m2][,m3]
7-65
Page 172
IPL Programming Reference Manual
Bar Code, Select Type (continued) Printers: Printer
Default Values for n
Notes
3240 n=0
0 - Code 39 1 - Code 93 2 - Interleaved 2 of 5 3 - Code 2 of 5 4 - Codabar 5 - Code 11 6 - Code 128 7 - UPC/EAN Codes 8 - HIBC Code 39 9 - Code 16K 10 - Code 49 11 - POSTNET 12 - PDF417 13 - Code One 14 - Maxicode 15 - JIS-ITF 16 - HIBC Code 128 17 - Data Matrix 18 - QR Code 19 - MicroPDF417
Modifiers (,m) apply only to bar code symbologies. Values for ,m vary depending on the symbology you select, as discussed on the following pages.
3400A n=0
0 - 11
You cannot select 12 to 19.
3400B n=0
0 - 17
You cannot select 18 or 19.
3400C 3400D 3400e n=0
0 - 19
3440 n=0
0 - 19
3600 n=0
0 - 17
You cannot select 18 or 19.
4100 n=0
0 - 11 Standard memory 1 - 14 Expanded memory
Standard: You cannot select 12 -19. Expanded: You cannot select 15 - 19.
4400 n=0
0 - 11
You cannot select 12 to 19.
44X0 n=0
0 - 19
4X30 n=0
0 - 12, 14, 16, 17
7421 n=0
0 - 19
EasyCoder F4 n=0
0 - 12, 14 - 19
You cannot select 13, 15, 18, or 19.
The following pages contain detailed descriptions of the different symbologies and the parameters that you can set for each.
7-66
Page 173
HelvC NugFont
Program Mode Commands C d 39
7
Bar Code, Select Type (continued) Code 39 c0[,m]
Selects Code 39. The default for ,m is 0. Intermec printers support three different types of Code 39: •
43 character Code 39
•
Full ASCII Code 39
•
8646 compatible Code 39 (except the EasyCoder F4 printer)
The 8646 compatible version only differs from the full ASCII version by four characters. The “$”, “%”, “/”, and “+” are encoded as single characters instead of as “/D”, “/E”, “/O”, and “/K.” The 8646 compatible version allows the printer to be backward compatible with 86XX printers. When you enter <ESC><SPACE> as data, the printer prints the start and stop characters. You can set c0[,m] to these values: c0,0 c0,1 c0,2 c0,3 c0,4 c0,5 c0,6 c0,7 c0,8
Selects 8646 compatible Code 39. No check digit. Selects 8646 compatible Code 39. Printer enters check digit. Selects 8646 compatible Code 39. Host enters check digit and printer verifies. Selects full ASCII Code 39. No check digit. Selects full ASCII Code 39. Printer enters check digit. Selects full ASCII Code 39. Host enters check digit and printer verifies. Selects 43 character Code 39. No check digit. Selects 43 character Code 39. Printer enters check digit. Selects 43 character Code 39. Host enters check digit and printer verifies.
Code 93 c1
Selects Code 93.
Interleaved 2 of 5 c2[,m]
Selects Interleaved 2 of 5. Default for ,m is 0. The printer adds a zero to character strings that are odd in length. You can set c2[,m] to these values: c2,0 c2,1 c2,2
Selects Interleaved 2 of 5. No check digit. Selects Interleaved 2 of 5. Printer enters check digit. Selects Interleaved 2 of 5. Host enters check digit.
7-67
Page 174
IPL Programming Reference Manual
Bar Code, Select Type (continued) Code 2 of 5 c3[,m]
Selects Code 2 of 5. Default for ,m is 0. You can set c3[,m] to these values: c3,0 c3,1
Selects Code 2 of 5. 3-bar start/stop code. Selects Code 2 of 5. 2-bar start/stop code.
Codabar c4[,m]
Selects Codabar. Default for ,m is 0. Valid start/stop characters range from A to D and from a to d. You can define them as part of the bar code field, or you can download them as part of the print data. Start/stop characters sent down with printer data override the characters defined by the bar code field. You can set c4[,m] to these values: c4,0 c4,1,x,y
Selects Codabar. Host enters start/stop codes and printer verifies. Selects Codabar. Printer enters start code x and stop code y. The values for x and y can range from A to D and from a to d.
Code 11 c5[,m]
Selects Code 11. The default for ,m is 0. You can set c5[,m] to these values: c5,0 c5,1 c5,2 c5,3
Selects Code 11. Printer enters 2 check digits. Selects Code 11. Printer enters 1 check digit. Selects Code 11. Host enters 2 check digits and printer verifies. Selects Code 11. Host enters 1 check digit and printer verifies.
Code 128 c6[,m1][,m2]
Selects Code 128. In Emulation mode, you can print the Function 1 character by entering <SUB> 1. In Advanced mode, you can print the Function 1 character by entering <SUB><SUB> 1. You can print the characters for Function 2, 3, and 4 in the same way. UCC-128 serial shipping container code automatically starts in subset C with a <FNC1>. It is a fixed length version of Code 128 requiring you to enter 19 numeric characters. The printer forces the first two characters to zero. The default for ,m1 = 0. The default for ,m2 = 0.
7-68
Page 175
HelvC NugFont
Program Mode Commands C d 39
7
Bar Code, Select Type (continued) You can set c6[,m1][,m2] to these values: c6,0,0 c6,0,1 c6,1,0 c6,1,1
Selects Code 128, keep parentheses and spaces. Selects Code 128, ignore parentheses and spaces in the bar code but keep them in the interpretive field. Selects UCC-128 Serial Shipping Container Code. Selects UCC-128 Serial Shipping Container Code and keep parentheses and spaces in interpretive field.
UPC/EAN c7[,m1][,m2]
Selects UPC/EAN Codes. Default for ,m1 is 0. Default for ,m2 is 0. The variable length option selects the UPC/EAN version by the number of characters in the data field. The number of data characters and check characters allowed for each version are: EAN 8 EAN 13 UPC version A UPC version E UPC version D1 UPC version D2 UPC version D3 UPC version D4 UPC version D5
7 data + 1 check character 12 data + 1 check character 11 data + 1 check character 6 data + 1 check character 13 data + 1 check character 18 data + 2 check characters 22 data + 2 check characters 25 data + 3 check characters 29 data + 3 check characters
Use a “.” to delimit the bar code data from the supplemental data. Data to the right of the “.” is supplemental data; data to the left is bar code data. You can add the two- or five-digit supplemental to any version of the UPC/EAN code. The flag 1 option only applies to EAN 8, EAN 13, and UPC version A. For EAN 13, enabling the flag 1 option prints the first character of the bar code interpretive. For EAN 8 and UPC version A, enabling the flag 1 option moves the first and last character of the bar code interpretive outside of the guard bars. You can set c7[,m1][,m2] to these values: c7,0[,m2] c7,1[,m2] c7,2[,m2] c7,3[,m2]
Selects UPC/EAN Codes. Printer enters check digit. Flag 1 enabled. Selects UPC/EAN Codes. Printer enters check digit. Flag 1 disabled. Selects UPC/EAN Codes. Host enters check digit and printer verifies Flag 1 enabled. Selects UPC/EAN Codes. Host enters check digit and printer verifies. Flag 1 disabled.
7-69
Page 176
IPL Programming Reference Manual
Bar Code, Select Type (continued) Use ,m2 to select the UPC/EAN codes listed below. Default is 0. 0 1 2 3 4 5 6 7 8 9 variable length EAN 8 EAN 13 UPC Version A UPC Version E UPC Version D1 UPC Version D2 UPC Version D3 UPC Version D4 UPC Version D5
UPC Versions D1 - D5 are not supported in the 3400 C/D, 3400e, 4420, 4440, or EasyCoder F4 printers.
HIBC Code 39 c8[,m1][,m2]
Selects HIBC Code 39. Default for ,m1 is 0. You can set c8[,m1][,m2] to these values to conform to the Supplier Standard: c8,0 c8,1 c8,2[,m2]
Selects HIBC Code 39. Primary format. Selects HIBC Code 39. Alternate primary format. Selects HIBC Code 39. Secondary format. The linkage character comes from ,m2, which is the field identifier.
You can set c8[,m1][,m2] to these values to conform to the Provider Standard: c8,3 c8,4 c8,5[,m2] c8,6
Single format. First data format. Selects HIBC Code 39. Second data format. The linkage character comes from ,m2, which is the field identifier. Selects HIBC Code 39. Multiple data format.
Code 16K c9
Selects Code 16K. In Emulation mode, use a <SUB> 1 to represent the function 1 character. To represent the function 1 character in Advanced mode, enter <SUB><SUB> 1. Represent the characters for functions 2, 3, and 4 in the same way. To produce a square symbol, specify a height magnification of 1 in Advanced mode. To specify a square symbol, use a height magnification of 250 in Emulation mode.
7-70