IPL Programming Reference Manual: Chapter 5: Advanced Printer Programming, pages 77 to 84

Pages 77 to 84 of 298, from IPL Programming Reference Manual

The original document is the PDF (1.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Intermec 3600 and Intermec 4400

Page 77

Advanced Printer Programming

5

Reimaging Modified Fields You can now choose to reimage only the fields in a label format that you modify instead of reimaging the entire label format. If you are updating data in only a few simple fields, it might be faster to use the modified field reimaging command; however, you need to take into account the type of fields you will be reimaging. If you choose to reimage a field that takes longer to erase and reimage than it takes an entire label format to erase and reimage, you will not be increasing throughput. Erasing a field requires reimaging it with zeros and erasing a label requires only clearing the RAM. When you use it correctly, this command parameter can greatly increase the throughput of your printer. To use the modified field reimaging command 1. Make sure that you select enough image bands to allow the printer to retain the entire label image. One image band is equal to 1 inch of label length. 2. Select the fields to reimage by using the following command: <ESC>En,m See the Format, Select command in Chapter 7 for more information about reimaging modified fields.

Optimizing Image Bands for Batch Printing If you frequently print batches of identical labels (using the <US> command) or print a quantity of identical labels, you may want to optimize the number of image bands for batch printing. Optimizing the number of image bands for batch printing is especially helpful if you experience delays between the printing of each label. To optimize the number of image bands for batch printing, you must select enough image memory to allow the printer to retain the entire label image. To optimize batch printing, select the number of image bands (1 band = 1 inch) to equal the label size. For example, if the printed image stops at a distance of four inches from the beginning of the label, you must select four image bands to prevent reimaging if the label is 5 inches long. The 3400C, 3400e, 3440, 4420, 4440, and 7421 printers automatically select the optimal number of image bands. If you increase the number of image bands on these printers, you may decrease performance.

5-9

Page 78

IPL Programming Reference Manual

Using Emulation Mode Note: The 4630 and 4830 printers do not support Emulation mode. Emulation mode lets you print bar code labels that were designed on an 86XX printer in multiples of 10 or 15 mil. (“Emulation mode” is also called “86XX Emulation mode” in some printer manuals.) Here is a summary of the features in Emulation mode: •

Pages are not available.

•

Character size is specified by height and width magnification only.

•

International characters are preceded by <SUB> or selectable by language.

•

The bitmaps for user-defined characters (UDC) and user-defined fonts (UDF) are one bit per byte (instead of six bits per byte).

•

Print resolution is in 10 mil dots.

Two IPL commands place the printer in Emulation mode: •

Emulation or Advanced Mode on Power-Up.

•

Emulation Mode, Enter.

This table lists all the IPL commands and specifies if the command works when the printer is in Emulation mode.

IPL Command Name

Syntax

Page

Works in Emulation Mode?

12 Volt Supply Value, Transmit

U

7-127

Yes

Abort Print Job

<EM>

7-10

Yes

Advanced Mode, Select

<ESC>C

7-15

Yes

Alphanumeric Field Separator

<GS>

7-16

Yes

Ambient Temperature, Transmit

A

7-127

N/A

Amount of Storage, Define

<SI>N

7-39

N/A

Audible Alarm, Enable or Disable

<SI>a

7-40

N/A

Auto-Transmit 1, Enable

<ESC>j

7-40

Yes

Auto-Transmit 2, Enable

<ESC>d

7-40

Yes

5-10

Page 79

Advanced Printer Programming

5

IPL Commands and Emulation Mode (continued) IPL Command Name

Syntax

Page

Works in Emulation Mode?

Auto-Transmit 3, Enable

<ESC>e

7-41

Yes

Auto-Transmit 1, 2, and 3, Disable

<ESC>k

7-41

Yes

Bar Code, Select Type c

7-65

Yes

Bar Code Field, Create or Edit

B

7-85

Yes

Batch Count, Set

<US>

7-17

Yes

Bitmap Cell Height for Graphic or UDF, Define y

7-86

Yes

Bitmap Cell Width for Graphic or UDF, Define x

7-88

Yes

Bitmap User-Defined Font, Clear or Define

T

7-90

Yes

Border Around Human-Readable Text, Define b

7-90

Yes

Box Field, Create or Edit

W

7-91

Yes

Character Bitmap Origin Offset, Define

X

7-92

Yes

Character Rotation or Bar Code Ratio, Define r

7-93

Yes

Clear All Data

<CAN>

7-17

Yes

Clear Data From Current Field

<DEL>

7-17

Yes

Code 39 Prefix Character, Define p

7-96

Yes

Command Tables, Load

C

7-96

Yes

Command Terminator

;

7-127

Yes

Command Terminator 1

<NUL>

7-17

Yes

Command Terminator 2

<LF>

7-18

Yes

Communication Port Configuration, Set

<SI>P

7-42

Yes

Configuration Parameters, Transmit

<ESC>p

7-18

Yes

Control Panel Access Permission, Set

<SI>A

7-43

Yes

Current Edit Session, Save

N

7-97

Yes

Cut

<SO>

7-18

Yes

Cutter, Enable or Disable

<SI>c

7-44

Yes

Dark Adjust

K

7-128

Yes

Dark Adjust, Set

<SI>d

7-44

Yes

Data Shift - International Characters

<SUB>

7-19

Yes

Data Source for Format in a Page, Define e

7-97

No

Direct Graphics Mode, Select

<ESC>g

7-20

No

5-11

Page 80

IPL Programming Reference Manual

IPL Commands and Emulation Mode (continued) IPL Command Name

Syntax

Page

Works in Emulation Mode?

Emulation Mode, Enter

<ESC>c

7-21

Yes

Emulation or Advanced Mode on Power-Up

<SI>C

7-45

Yes

End-of-Print Skip Distance, Set

<SI>D

7-46

Yes

Error Code, Request

<BEL>

7-10

Yes

Factory Defaults, Reset

D

7-128

Yes

Field, Delete

D

7-98

Yes

Field, Select

<ESC>F

7-22

Yes

Field Data, Define Source d

7-98

Yes

Field Decrement, Set

<ESC>D

7-23

Yes

Field Direction, Define f

7-100

Yes

Field Increment, Set

<ESC>I

7-24

Yes

Field Origin, Define o

7-100

Yes

First Data Entry Field, Select

<ACK>

7-24

Yes

Font, Transmit

<ESC>v

7-25

Yes

Font Character Width, Define

Z

7-101

Yes

Font Type, Select c

7-103

Yes

Form Feed

<FF>

7-26

Yes

Format, Create or Edit

A or F

7-105

Yes

Format, Erase

E

7-107

Yes

Format, Select

<ESC>E

7-26

Yes

Format, Transmit

<ESC>x

7-28

Yes

Format Direction in a Page, Define q

7-106

No

Format Offset Within a Page, Define

O

7-107

No

Format Position From Page, Delete m

7-108

No

Format Position in a Page, Assign

M

7-108

No

Formats, Print f

7-128

Yes

Graphic, Select c

7-109

Yes

Graphic or UDC, Define u

7-109

Yes

Hardware Configuration Label, Print h

7-128

Yes

Height Magnification of Bar, Box, or UDC, Define h

7-110

Yes

5-12

Page 81

Advanced Printer Programming

5

IPL Commands and Emulation Mode (continued) IPL Command Name

Syntax

Page

Works in Emulation Mode?

Human-Readable Field, Create or Edit

H

7-113

Yes

IBM Language Translation, Enable or Disable

<SI>i

7-47

Yes

Increment and Decrement, Disable

<ESC>N

7-29

Yes

Intercharacter Delay, Set

<SYN>

7-47

Yes

Intercharacter Space for UDF, Define z

7-114

Yes

Interlabel Ribbon Save, Enable or Disable

<SI>s

7-48

N/A

Interpretive Field, Edit

I

7-115

Yes

Interpretive Field, Enable or Disable i

7-115

Yes

Label and Gap Length, Transmit

<ESC> L

7-11

Yes

Label Path Open Sensor Value, Transmit

L

7-129

N/A

Label Rest Point, Adjust

<SI>f

7-48

Yes

Label Retract, Enable or Disable

<SI>R

7-49

Yes

Label Retract Distance, Set

<SI>r

7-49

Yes

Label Stock Type, Select

<SI>T

7-50

Yes

Label Taken Sensor Value, Transmit

T

7-129

Yes

Label Width, Set

<SI>W

7-50

N/A

Length of Line or Box Field, Define l

7-116

Yes

Line Field, Create or Edit

L

7-116

Yes

Maximum Label Length, Set

<SI>L

7-51

Yes

Media Fault Recovery Mode, Set

<SI>e

7-52

Yes

Media Sensitivity, Select

<SI>g

7-52

Yes

Memory Usage, Transmit

<ESC>m

7-30

Yes

Message Delay, Set

<ESC><SYN>

7-54

Yes

Next Data Entry Field, Select

<CR>

7-31

Yes

Number of Image Bands, Set

<SI>I

7-54

Yes

Numeric Field Separator

<FS>

7-31

Yes

Online or Offline on Power-Up

<SI>O

7-55

N/A

Options Selected, Transmit

<ESC>O

7-32

Yes

Outline Font, Clear or Create

J

7-117

No

Outline Font, Download j

7-118

No

5-13

Page 82

IPL Programming Reference Manual

IPL Commands and Emulation Mode (continued) IPL Command Name

Syntax

Page

Works in Emulation Mode?

Page, Create or Edit

S

7-119

No

Page, Delete s

7-120

No

Page, Select

<ESC>G

7-33

No

Page, Transmit

<ESC>y

7-33

No

Pages, Print p

7-129

Yes

Pin 11/20 Protocol, Set

<SI>p

7-56

No

Pitch Label, Print

C

7-129

Yes

Pitch Size, Set g

7-120

No

Point Size, Set k

7-121

No

Postamble, Set

<EOT>

7-57

Yes

Preamble, Set

<SOH>

7-57

Yes

Print

<ETB>

7-34

Yes

Print Line Dot Count Limit, Set v

7-122

N/A

Print Quality Label, Print

Q

7-129

Yes

Print Speed, Set

<SI>S

7-58

Yes

Printer Language, Select

<SI>l

7-59

Yes

Printhead Loading Mode, Select

<SI>h

7-61

No

Printhead Parameters, Transmit

<ESC>H

7-34

Yes

Printhead Pressure, Set

<SI>H

7-62

N/A

Printhead Resistance Test, Begin

B

7-130

N/A

Printhead Resistance Values, Transmit

S

7-130

N/A

Printhead Temperature Sensor Value, Transmit

P

7-130

Yes

Printhead Test Parameters, Set

<SI>U

7-62

N/A

Printhead Volt Supply Value, Transmit

V

7-130

N/A

Program Mode, Enter

<ESC>P

7-34

Yes

Program Mode, Exit

R

7-122

Yes

Program Number, Transmit

<ESC>M

7-35

Yes

Program Number and Model, Transmit

<ESC>M

7-35

Yes

Quantity Count, Set

<RS>

7-35

Yes

Reflective Sensor Value, Transmit

M

7-130

No

Remaining Quantity and Batch Count, Transmit

<ESC>Q

7-11

Yes

5-14

Page 83

Advanced Printer Programming

5

IPL Commands and Emulation Mode (continued) IPL Command Name

Syntax

Page

Works in Emulation Mode?

Reset

<DLE>

7-11

Yes

Ribbon Save Zones, Set

<SI>Z

7-63

N/A

Self-Strip, Enable or Disable

<SI>t

7-63

Yes

Software Configuration Label, Print s

7-130

Yes

Start and Stop Codes (Code 39), Print

<ESC><SP>

7-35

Yes

Status Dump

<VT>

7-12

Yes

Status Enquiry

<ENQ>

7-13

Yes

Takeup Motor Torque, Increase

<SI>b

7-64

No

Test and Service Mode, Enter

<ESC>T

7-36

Yes

Test and Service Mode, Exit

R

7-130

Yes

Top of Form, Set

<SI>F

7-65

Yes

Transmissive Sensor Value, Transmit

G

7-131

Yes

User-Defined Character (UDC) and Graphics, Print g

7-131

Yes

User-Defined Character, Clear or Create

G

7-122

Yes

User-Defined Character Field, Create or Edit

U

7-123

Yes

User-Defined Characters, Transmit

<ESC>u

7-36

Yes

User-Defined Font Character, Create t

7-124

Yes

User-Defined Fonts, Print t

7-131

Yes

User-Defined Tables, Transmit

<ESC>Z

7-37

Yes

Warm Boot

<BS>

7-37

Yes

Width of Line, Box, Bar, or Character, Define w

7-125

Yes

5-15

Page 84