The text of a manual · part 22 of 26

Trakker Antares 248X Stationary Terminal User's Manual, pages 211 to 220

Pages 211 to 220 of 257

The original document is the PDF (1.9 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Intermec 2486

Page 211

nugget

39 Reader Command Reference

6

Transmit File Via Network Communications Purpose: From Network:

Transmits a file from the T2480/1 with Ethernet or the T2485/6 and saves it on the Model 200 Controller or host. %%R,drive:fromfilename,tofilename where: %%R is the command to transmit a file over the RF or Ethernet network from the T248X to the controller or host.

drive:

indicates the drive where the file is stored on the T248X. You must include the colon (:) after the drive letter.

fromfilename is the name of the file you are transmitting from the T248X to the controller or host.

tofilename is the name of the file that will be saved on the controller or host. On the controller, the file is saved on the D:\USERDATA directory. To transmit a file to the host, you need to identify the path and filename where you want to save the file. Note: Do not specify the pathname D:\USERDATA in the tofilename field.

Keypad: Scan:

Not supported 1. Scan this bar code label: Enter Accumulate Mode / Transmit File

*/K/O/E/ER/L* *+/%%R,*

2. Scan the bar code label(s) for the file you want to transmit. You can scan labels from the “Full ASCII Bar Code Chart” in Appendix B. The label must use this format: drive:fromfilename,tofilename

3. Scan this bar code label to exit Accumulate mode and transmit the file. Exit Accumulate Mode

*-/* *-/*

Or:

You can create your own bar code labels to transmit files by creating a bar code in this command format: %%R,drive:fromfilename,tofilename

6-21

Page 212

A Terminal Specifications

Page 213

This page is a scan with no text; see it in the PDF.

Page 214

nugget

39 Terminal Specifications

A

This appendix lists the terminal’s physical and environmental specifications, lists the default configuration, and provides a configuration command reference list in alphabetical order by command syntax.

Physical and Environmental Specifications You can use the tables in this section to find technical information about these features and options: •

Terminal Dimensions

•

Power Specifications

•

Electrical Specifications

•

Temperature and Environmental Specifications

•

Screen

•

Keypad Options

•

Application Options

•

Memory

•

RF Communications

•

RF Network Support Options

•

Wired Data Communications

•

Bar Code Symbologies

•

Input Devices for the External Scanner Port

Note: For programming and file system specifications, see Chapter 5, “Using Custom Applications and Screen Mapping.”

A-3

Page 215

TRAKKER Antares 248X Stationary Terminal User’s Manual nugget 39

Specifications Terminal Dimensions Length:

10.7 in (27.2 cm) 11.3 in (28.7 cm) with a badge scanner installed

Height:

9.6 in (24.4 cm)

Depth:

3.9 in (9.9 cm)

Weight:

9.5 lbs (4.3 kg)

Power Specifications Operating (with power supply):

95 to 250 VAC, 50 to 60 Hz, 125 mA

Memory Backup:

Rechargeable NiCd 700 mA battery pack

Electrical Specifications Models: Electrical rating:

T2480, T2481, T2485, and T2486

S 12V, 750 mA

Temperature and Environmental Specifications Operating the terminal:

-4°F to +122°F

-20°C to +50°C

Storing the terminal:

-4°F to +140°F

-20°C to +60°C

Charging the backup battery:

+32°F to +104°F

0°C to +40°C

Relative humidity:

0 to 95% non-condensing

Screen •

CGA-compatible, backlit LCD

•

4 lines by 40 characters for T2480 and T2485

•

12 lines by 40 characters for T2481 and T2486, display up to 25 lines

Keypad Options •

Alphanumeric keypad with 59 keys, 5 separate function keys, PC-style layout, available in English, French, German, Italian, Portuguese, or Spanish

•

Oversized function numeric keypad with 35 keys, 10 separate function keys

•

Terminal emulation keypads for IBM 3270, IBM 5250, and VT/ANSI

•

Time and attendance keypad

Note: See your Intermec sales representative for information about the availability of the time and attendance keypad.

A-4

Page 216

nugget

39 Terminal Specifications

A

Application Options •

Programmable terminal

•

IBM 3270 terminal emulation

•

IBM 5250 terminal emulation

•

VT100/220/320 and ANSI terminal emulation

•

Screen mapping for 3270, 5250, or VT/ANSI (UDP Plus terminals only)

Memory •

2MB programmable flash memory, 750K available for use

•

1MB battery-backed RAM, 512K available for user

•

Extended memory option for an additional 2MB flash

•

Extended memory option for an additional 2MB or 4MB SRAM storage drive

RF Communications •

2.4 GHz (to 2.4835 GHz) radio (frequency range varies by country)

•

WLI Forum OpenAir™ compatible frequency hopping spread spectrum radio

•

100 mW maximum output power

•

1.6 Mbits per second data speed, 800 Kbps fallback rate for extended range

•

Coverage ≥ 240 feet (80 meters)

•

RF network protocol options: TCP/IP or UDP Plus

RF Network Support Options •

Connectivity to a host on an Ethernet, token ring, twinaxial, coaxial, or SDLC network through an access point and Model 200 Controller using UDP Plus protocol

•

Connectivity to a host on an Ethernet or token ring network through an access point using TCP/IP protocol

Wired Data Communications •

RS-232C serial port (COM1)

•

RS-232C/422/485 serial port (COM2) with enhanced input/output board

•

RS-232C serial port (COM4) with adapter cable accessory (Part No. 067185)

•

Ethernet (10BaseT)

•

Ethernet network protocol options: TCP/IP or UDP Plus

•

XMODEM/YMODEM protocol for data transfer

•

Protocols: Configurable Serial Protocol, Multi-Drop, Polling Mode D, Master Polling, Binary

A-5

Page 217

TRAKKER Antares 248X Stationary Terminal User’s Manual nugget 39 Bar Code Symbologies •

Codabar

•

Code 93

•

Code One

•

Code 128

•

Code 11

•

Interleaved 2 of 5

•

Code 16K

•

MSI

•

Code 2 of 5

•

PDF 417

•

Code 39

•

Plessey

•

Code 49

•

UPC/EAN

Input Devices for the External Scanner Port You can attach these input devices to the external scanner connector: •

Intermec 1354 and 1355 badge scanners

•

Intermec 1463A and 1463D CCD scanners

•

Intermec 1516A, 1517A, 1517B, 1518, and 1519A laser scanners

•

Intermec 1545 laser scanner

•

Intermec 1550A laser scanner

•

Intermec 126X, 127X, and 128X wands

You must use an interface cable to connect the input device to the scanner connector. For help, contact your local Intermec service representative.

Note: If you do not have a device installed on the badge scanner connector, you can use the Intermec 1464 CCD scanner, the Intermec 1550B laser scanner, and the Intermec 1551 laser scanner. To use the 1463A and 1463D CCD scanners together with a device installed on the badge scanner connector, you must configure the 1463A or 1463D Trigger mode to either Manual Trigger or Auto-Trigger.

A-6

Page 218

nugget

39 Terminal Specifications

A

Default Configuration The next tables show the terminal’s default configuration. You can use the TRAKKER Antares 2400 Menu System to set the terminal to the default configuration. For help, see “Restoring the Terminal’s Default Configuration” in Chapter 3.

Default Configuration for Bar Code Symbologies Parameter

Default

Codabar

Disabled

Code 11

Disabled

Code 16K

Disabled

Code 2 of 5

Disabled

Code 39

Full ASCII Code 39 enabled with no check digit

Code 49

Disabled

Code 93

Disabled

Code 128

Standard

Interleaved 2 of 5

Disabled

MSI

Disabled

Plessey

Disabled

UPC/EAN

UPC-A/EAN-13 enabled, UPC-E and EAN-8 enabled, supplementals allowed, transmit check digit, transmit number system digit, and retain leading zero for UPC-A

A-7

Page 219

TRAKKER Antares 248X Stationary Terminal User’s Manual nugget 39

Default Configuration for Operations

A-8

Parameter

Default

Append Time

Disabled

Automatic Shutoff

0 minutes (disabled)

Beep Volume

Normal

Command Processing

All reader commands enabled

Decode Security

Moderate

Display Contrast

3 (maximum contrast)

Display Font Type

8x16 font

Display Row Spacing

0 (T2481 and T2486 only)

Display Video Mode

Original

Keypad Caps Lock

Caps lock off

Keypad Clicker

Enabled

Keypad Type

Hardware default

Postamble

No characters (disabled)

Preamble

No characters (disabled)

RAM Drive Size

0 (no RAM drive)

Resume Execution

Allowed

Scan Ahead

Disabled

Scanner Mode

One-Shot mode

Scanner Redundancy

Normal

Scanner Selection

All compatible scanners

Scanner Timeout

Disabled (no timeout)

Scanner Trigger

Level triggering

Time and Date

9601071200000

Time in Seconds

Disabled

Page 220

nugget

39 Terminal Specifications

A

Default Configuration for RF and Ethernet Network Communications Parameter

Default

Acknowledgement Delay Lower Limit

300 ms

Acknowledgement Delay Upper Limit

5000 ms

Controller Connect Check Receive Timer

60 seconds

Controller Connect Check Send Timer

35 seconds

Controller IP Address

0.0.0.0

Default Router

0.0.0.0

Host IP Address

0.0.0.0

Maximum Retries

7

Network Activate

Disabled

Network Loopback

Disabled

Network Port

23 (Telnet) for a TCP/IP network 5555 for a UDP Plus network

RF Domain

0

RF Inactivity Timeout

5 seconds

RF Roaming Flag

Allowed

RF Security Identification (ID)

None

RF Transmit Mode

BFSK

RF Wakeup On Broadcast

No (disabled)

Subnet Mask

255.255.255.0

TCP/IP Maximum Transmit Timeout

32 seconds

Terminal IP Address

0.0.0.0

A-9