Page 181

nugget

39 Using Custom Applications and Screen Mapping

5

4. From the Terminal Download Configuration dialog box in the Terminals and Groups list box, select a terminal or group of terminals to receive the binary applications and files. For help defining a group of terminals, see “Adding a Group in the Download Server” in Appendix B of the Model 200 Controller System Manual. 5. Choose Edit. The Configure Device Initialization Download dialog box appears.

6. Verify that there are no files (or entries) listed in the Files and Data list box. If there are entries, then choose Clear to remove them. 7. In the Initialization Data box, choose File. 8. In the field, type: \filename where filename is the name of the executable binary application. Or choose Find, select your application, and choose OK. 9. Enable the Binary file check box. 10. Enable the Overwrite option button to overwrite an existing file with the same name. 11. In the Target file name field, type a name if you want to save the file under a different name on the terminal. Do NOT enter a slash or backslash character before the target filename. 12. Choose Add. The file appears in the Files and Data list box with a B for binary in the leftmost column.

5-15

Page 182

TRAKKER Antares 248X Stationary Terminal User’s Manual nugget 39

Configure Device Initialization Download Dialog Box

13. Repeat Steps 7 through 12 to select another application. 14. You can also download files used by your application such as an employee list or a part number list. To download additional files, choose File in the Initialization Data box. Type in the filename including the backslash. Disable the Binary file check box and then choose Add. 15. Choose OK to save your changes and return to the Terminal Download Configuration dialog box. 16. In the Terminals and Groups list box, choose the terminal or group you configured if it is not already highlighted and marked with an asterisk. 17. Choose Download. A Download initiated message box appears. 18. Choose OK. The executable binary applications and files are downloaded to the terminal or group of terminals usually within a few seconds. If you are downloading the applications and files to many terminals or there is a lot of radio traffic in your 2.4 GHz RF network, the download may take longer. All files are downloaded and stored on the terminal’s flash drive C. 19. Choose Close to close the dialog box and return to the System Maintenance dialog box. To run an application, continue with the instructions in the next section.

5-16

Page 183

nugget

39 Using Custom Applications and Screen Mapping

5

Running the Application on the Terminal Once you have downloaded an application to the terminal, you are ready to run and use it. There are three ways to run an application: •

Use the FileCopy utility. For help, see “Using the Serial Port to Transfer Applications and Files” earlier in this chapter.

•

Use the Run Program reader command. For help, see “Run Program” in Chapter 6.

•

Use the TRAKKER Antares 2400 Menu System.

The instructions in this section explain how to use the TRAKKER Antares 2400 Menu System to load and run an application. To run an application on the terminal

1. Press or scan this bar code label to access the TRAKKER Antares 2400 Menu System. Enter Test and Service Mode

*..-.* *..-.*

The Main Menu appears. 2. Choose System Menu and press System Menu appears.

The

248XU.001

SYSTEM MENU File Manager Load Default Values Set Time and Date Store Configuration Upgrade Firmware ⁄

_` Select item [Enter] Next screen [F1] Help [Esc] Exit 248XU.051

5-17

Page 184

TRAKKER Antares 248X Stationary Terminal User’s Manual nugget 39 3. Choose File Manager and press prompting you to select a drive. FILE Select

MANAGER drive:

OK

The File Manager screen appears

C

CANCEL 248XU.046

4. Press to select drive C or type in the letter of the drive you want to manage and then press . The File Manager screen appears listing all the files stored on the drive.

FILE MANAGER C:APPTSK.BIN 06144 C:VTTCP-D.BIN 0196K C:TEANT.CFG 00274

00572654 Bytes Free [Enter] Run App [F7] Rename [DEL] Delete [F1] Help [Esc] Exit 248XU.179

Y _

5. Press or to choose an application and then press boots, resets all firmware, and runs the application.

The terminal

If you also made configuration changes while you were working in the menu system, you will be prompted to store your changes in flash memory. Once you save or discard the changes, the terminal boots, resets all firmware, and runs the application. Note: You can press

Z to rename a file or to delete a file.

You can begin using the application to collect data. Repeat the instructions in this section to run another application on the terminal.

5-18

Page 185

nugget

39 Using Custom Applications and Screen Mapping

5

Troubleshooting Applications Once you download a new application to the terminal, you are ready to test it before you start collecting data. If the terminal or application appears to be locked up and you cannot enter data, try these steps in order. To troubleshoot a locked-up terminal or application f

1. Press to turn off the terminal. If it turns off, press terminal. You can continue working.

f to turn on the

2. Scan the Reset Firmware label to restart the firmware and application. Reset

*-.* *-.*

You can also send the Reset Firmware command over the network. For help, see Chapter 6, “Reader Command Reference.” 3. Use the TRAKKER Antares 2400 Menu System to configure the Resume Execution command to resume “not allowed.” Choose Terminal Menu from the Configuration Menu and then choose Power Management. Each time you press to turn on the terminal, the terminal boots and restarts your application.

f

4. If your terminal appears to boot but the application will not run or is locked up, press and hold the key immediately after you scan the Reset Firmware label or press to turn on the terminal in Step 3. Continue to hold the key for at least 30 seconds after the TRAKKER Antares welcome screen has cleared.

a a f

The terminal has booted without loading an application. Use the TRAKKER Antares 2400 Menu System to load another application or download a new version of the application before you run it again. 5. If the terminal will not turn off or does not respond to the Reset Firmware command, reset the terminal. Make sure you have tried Steps 1 and 2 before you reset the terminal. Caution If the terminal is turned on and you push the Reset button, you may lose data and you may have to reload the firmware. Conseil Si le terminal est allumé et que vous appuyez sur le bouton de remise à zéro, vous risquez de perdre des données et d’avoir à recharger le microprogramme.

5-19

Page 186

TRAKKER Antares 248X Stationary Terminal User’s Manual nugget 39 f a. Press to turn off the terminal. If it will not turn off, continue with the next step. b. Use a Phillips screwdriver to remove the six screws on the back panel. c. Remove the back panel. d. Press the Reset button. The T248X will briefly turn on and then turn off. Reset button

248XU.045 e. Place the back panel on the back of the terminal. f.

Use a Phillips screwdriver to attach the six screws.

f h. Press to boot the terminal and start your application.

g. Press to turn on the terminal. It boots all the systems and clears RAM memory. The Boot Menu appears. 6. If you keep returning to the Boot Menu or the terminal will not boot, try loading the firmware. For help, see “Upgrading the Firmware” in Chapter 3. If the terminal will not boot or reset, contact your local Intermec service representative for help.

5-20

Page 187

nugget

39 Using Custom Applications and Screen Mapping

5

Using Screen Mapping You can use screen mapping to send screen transactions from a TRAKKER Antares 248X terminal with UDP Plus through the Model 200 Controller to a host application. On the controller, you create the terminal screens, group them into menus, and generate each menu into a terminal template that is downloaded to the terminal. Script files that you build on the controller allow the transaction fields from the terminal screens to be mapped to different host screen fields. Make sure you have installed the T2485/6 in your 2.4 GHz RF network or the T2480/1 in your Ethernet network. For help, see Chapter 2, “Installing the Terminal.” Before you can run screen mapping on your terminal, you need to generate a terminal template and script file on the controller. For help, see the Model 200 Controller System Manual. If you have completed these tasks, you can start the screen mapping application. Note: Screen mapping is only available in a Model 200 Controller network.

Starting the Screen Mapping Application There are two ways to load a template on the T248X: •

You can download the template from the controller. For help, see the Model 200 Controller System Manual.

•

You can have the T248X request a template from the controller.

To request a template from the controller f

1. Press the key to turn on the terminal. The T248X screen prompts you to enter the name of the template you want to use:

File name:

248XU.060

5-21

Page 188

TRAKKER Antares 248X Stationary Terminal User’s Manual nugget 39 2. Type a template name and press menu.

The terminal displays your template

Note: Make sure your template name has a .TPL file extension.

Running Screen Mapping on Your Terminal Once you have selected a template, you need to select the screen where you want to enter data. To enter data into a screen

_ Y

1. From the template menu, use the or keys to highlight the screen you want to use. The next screen shows an example of a template menu.

ABC Company Work order entry Shipping Receiving Inventory Time card entry

Select F2 File F4 248XU.061

Z

2. Press to choose the screen. The screen you chose appears on the terminal screen and the screen name is in the title bar. 3. Type or scan data into the fields. Use the for each field.

_ , Y , or to accept the data

4. When you finish entering data into the fields:

b to send the transaction to the controller. • Press [ to reset the screen and reposition the cursor to the first input field without sending the data. • Press ^ to exit the screen without sending the data and return to the •

Press template screen menu.

5-22

Page 189

nugget

39 Using Custom Applications and Screen Mapping

5

Requesting a New Template You can run one terminal template at a time on the TRAKKER Antares 248X terminal. If you want to change templates, you need to request a new one from the Model 200 Controller. To request a new template from the controller 1. From the template menu, press

\ to download a new template.

2. Type the name of the template you want to use when the screen prompts you to enter a file name. Note: Make sure your template name has a .TPL file extension.

File name:

248XU.060

3. Press

The new template menu appears on your terminal.

Loading a Validation File You can use a validation file to ensure that the information you enter in the input fields of your terminal screen is correct. There are two ways to load a validation file on the T248X: •

You can download the validation file from the Model 200 Controller. For help, see the Model 200 Controller System Manual.

•

You can use the T248X to request a validation file from the Model 200 Controller.

To request a validation file from the controller

\

1. From the template menu, press to download a new file. The screen prompts you to enter a file name.

5-23

Page 190

TRAKKER Antares 248X Stationary Terminal User’s Manual nugget 39

Requesting a Validation File

File name:

248XU.060

2. Type the name of the validation file you want to download. Note: Make sure that your filename contains a valid file extension. The filename cannot have the .TPL extension or the screen mapping application will try to load the validation file as a template. 3. Press

5-24 download the validation file from the controller.