For the Intermec 2460 and Intermec 2461

Page 271

nugget Using the Default Applications

•

C

On the 246X terminal, you can select character sets by using the DX configuration command or the ANSI escape sequence (ESC[dataw). For help, see “Selecting Character Sets” later in this appendix.

Using Display Control Codes You can use control codes to position the cursor or to format the terminal display. The EM9560.BIN application recognizes the display control codes listed next. Command

Control Code

Description or Action

Backspace

BS (08 Hex)

Moves the cursor one position to the left until the cursor reaches the first column. If the cursor is in the first column of any row except the first row, a Backspace command moves the cursor to the last column of the previous row.

Cursor Position

ESC[n;vH

Moves the cursor to the position specified by the n and v parameters where: n specifies the row or line number. v specifies the column number. If you enter zero or no parameter, n and v are set to one. If n or v exceeds the maximum row or column number on the display, the parameters are set to the screen’s maximum.

Erase Display

ESC[2J

Erases the entire display and returns the cursor to the home position (row 1, column 1). This command also erases the entire virtual display image (buffer with up to two rows of the most recently displayed data).

Home

CR (0D Hex)

Returns the cursor to the first column of the current row.

Next Line

LF (0A Hex)

Moves the cursor down one row in the current column position. If the cursor is already in the last row, a new line is added.

Restore Configured Character Set

ESC[x

Returns the display to the character set that is defined in the default configuration.

Restore Cursor Position

ESC[u

Restores the cursor position saved with a Save Cursor Position command. Each Restore Cursor Position command must be paired with a preceding Save Cursor Position command. If a Save Cursor Position command has not been previously entered, the cursor position will not change.

C-5

Page 272

TRAKKER Antares 246X Stationary Terminal User’s Manual nugget

Using Display Control Codes (continued) Command

Control Code

Description or Action

Save Cursor Position

ESC[s

Saves the current cursor position. Successive Save Cursor Position commands overwrite the previous position that was saved.

Select Character Set

ESC[nw

Defines the character set to be used where n identifies the character set. For help, see “Selecting Character Sets” later in this appendix.

Setting Preambles and Postambles With the EM9560.BIN application, you can set Preamble A, Preamble B, and Postamble C on the TRAKKER Antares terminal and make the terminal compatible with the 95XX terminals. The preambles are prepended and the postamble is appended to the data that is transmitted through all the serial ports. Preamble A, Preamble B, and Postamble C can each be up to 25 ASCII characters in length. If you enter a preamble or postamble command without entering data, the preamble or postamble buffer is cleared. Syntax:

Scan:

Preamble A Preamble B Postamble C

AAdata or +.data ABdata or ++data ACdata or +%data

To set the preamble or postamble using the AA, AB, or AC configuration commands: 1. Scan one of these bar code labels: Enter Accumulate Mode / Set Preamble A

*+/$+AA* *+/$+AA* Enter Accumulate Mode / Set Preamble B

*+/$+AB* *+/$+AB* Enter Accumulate Mode / Set Postamble C

*+/$+AC* *+/$+AC*

2. Scan a value for data from the “Full ASCII Bar Code Chart” in Appendix B. The preamble or postamble can be from 1 to 25 characters.

C-6

Page 273

nugget Using the Default Applications

C

3. Scan this bar code: Exit Accumulate Mode

*-/* *-/*

4. Repeat Steps 1 to 3 to set another preamble or postamble. Or:

To set the preamble or postamble using the +., ++, or +% reader commands: 1. Scan one of these bar code labels: Enter Accumulate Mode / Set Preamble A

*+/+.* *+/+.* Enter Accumulate Mode / Set Preamble B

*+/++* *+/++* Enter Accumulate Mode / Set Postamble C

*+/+%* *+/+%*

2. Scan a value for data from the “Full ASCII Bar Code Chart” in Appendix B. The preamble or postamble can be from 1 to 25 characters. 3. Scan this bar code: Exit Accumulate Mode

*-/* *-/*

4. Repeat Steps 1 to 3 to set another preamble or postamble.

C-7

Page 274

TRAKKER Antares 246X Stationary Terminal User’s Manual nugget

Full ASCII Mode for Code 39 With the EM9560.BIN application, you can configure Full ASCII mode for Code 39 using any of these commands: •

Code 39 configuration command (CB)

•

Full ASCII configuration command (RB)

•

Enter Full ASCII Mode reader command (+$) and the Exit Full ASCII Mode reader command (-$)

The last two commands are compatible with the Intermec 95XX terminals. Each command is described next. For help with the Code 39 configuration command (CB), see Chapter 8, “Configuration Command Reference.” Note: Use the CB configuration command unless your terminals need to be compatible with the 95XX terminals in your data collection network. Command:

Full ASCII configuration command (RB)

Purpose:

Configures the terminal to use Code 39 Full ASCII mode (enabled) or Code 39 NonFull ASCII mode (disabled). For a list of ASCII characters, see the “Full ASCII Table” in Appendix B.

Syntax:

RBdata Acceptable values for data are: 0 1

Scan:

Disabled Enabled

One of these bar code labels: Disable Full ASCII Mode

Command:

*$+RB0*

*$+RB1*

*$+RB0*

*$+RB1*

Enter Full ASCII Mode reader command

Purpose:

Enables Code 39 Full ASCII mode so the terminal decodes Code 39 bar code labels by using a two-character encoding scheme to extend the character set to 128 characters. For a list of ASCII characters, see the “Full ASCII Table” in Appendix B.

Syntax:

+$

Scan:

Full ASCII

*+$* *+$*

C-8

Enable Full ASCII Mode

Page 275

nugget Using the Default Applications

Command:

C

Exit Full ASCII Mode reader command

Purpose:

Exits Code 39 Full ASCII mode and puts the terminal in Code 39 Non-Full ASCII mode (one-character encoding scheme).

Syntax:

-$

Scan:

Exit Full ASCII

*/M/D* *-$*

Selecting Character Sets On the 246X terminal, you can select the character set to display on the terminal screen. You can select the character set using either of these two commands: •

Character Set configuration command (DX)

•

ANSI escape sequence (ESC[dataw)

The character set feature is backward compatible with the 95XX terminals and allows you to display a subset of characters from Western European languages, such as French, German, Italian, Portuguese, Spanish, and others. The Character Set command (DX) is supported through the terminal firmware, but the ANSI escape sequence is only supported through the EM9560.BIN application. See Chapter 8 for more information on using the Character Set command. Purpose:

Determines the language used to display characters. The default is U.S. ASCII.

Syntax:

ESC[dataw Acceptable values for data are: 0 1 2 3 4 5 6 7

U.S. ASCII French German United Kingdom Danish Swedish Italian Spanish

Note: See the Character Set (DX) command in Chapter 8 for a complete table of the international characters.

C-9

Page 276

TRAKKER Antares 246X Stationary Terminal User’s Manual nugget

Unsupported 95XX Features These 95XX features are not supported by the EM9560.BIN application on the TRAKKER Antares terminal. •

Display Setting configuration command (OD) (buffered or transparent display).

•

Command Override reader (data entry) command (DLE).

•

Right Host Message reader command (HT).

•

Preamble A Required configuration command (OA).

•

Computer Response Required Mode (CRRM) configuration command (PB), Enter CRRM reader command (./), and Exit CRRM reader command (.-).

•

Resume IRL configuration command (XG).

•

Separate transmit and receive EOM characters (PI and PJ). The configurable EOM (PF, YZ) is used for both transmit and receive EOM.

•

Capacity reader command (%$).

•

Forward and Review reader commands (%+ and %/).

•

Download Program command from the 9154 or 9161 controller. Use the Transmit File reader command. For help, see Chapter 7, “Reader Command Reference.”

Running APPTSK.BIN and EM9560.BIN To run APPTSK.BIN or EM9560.BIN on your terminal, use the Run Program reader command. To run APPTSK.BIN or EM9560.BIN on the terminal

1. Scan one of these bar code labels: Run APPTSK.BIN

*/O/OC/ZAPPTSK/NBIN* *//C:APPTSK.BIN* Run EM9560.BIN

*/O/OC/ZEM9560/NBIN* *//C:EM9560.BIN*

C-10

Page 277

nugget Using the Default Applications

C

The terminal boots, resets all firmware, and runs the application. The initial screen for the application appears. You see one of these screens: APPTSK.BIN Screen 1998/01/01

EM9560.BIN Screen

12:00:00

246XU.014

2. Scan this bar code label to toggle the clock display on or off. Toggle Clock Display

*CLOCKDISPLAY* *CLOCKDISPLAY*

3. Use the application to scan bar code labels, enter data through the keyboard, and transmit data. The next section lists some examples of how you can use the applications.

Example 1 Use the application to troubleshoot and test communications before loading and running your data collection application. Connect the terminal to your network. Type data (“Hello World”) on the TRAKKER Antares terminal keyboard or scan a bar code label. The data is sent out all serial and network ports and should be received by the host if your terminal is installed and configured correctly. Send data from the host and verify that the data displays on the terminal screen.

Example 2 Connect a serial input device, such as a 2D scanner, to a serial port on the 2461 terminal. Data from the input device is displayed on the terminal screen and transmitted out the network (Ethernet) port.

Example 3 Connect the 2460 to a serial port on the T2485 or T2486 terminal. Use the 2460 to collect data and upload the data from the 2460 to the T248X. Data is transmitted to the T248X and out the RF port to the connected network devices.

C-11

Page 278

TRAKKER Antares 246X Stationary Terminal User’s Manual nugget

Example 4 Connect the COM1 serial port to the COM2 serial port on the 2460. Use the 2460 terminal to configure itself by typing and entering configuration commands on the keypad or keyboard.

Example 5 Connect the serial port on the TRAKKER Antares 248X to the serial port on the TRAKKER Antares 246X terminal. Use the T248X to configure the 246X by typing and entering configuration commands on the T248X keypad.

C-12

Page 279