Page 261
nugget
39 Full ASCII Charts
B
Notes for the Full ASCII Table
0
Bit positions are 76543210.
1
This column lists the hexadecimal value.
2
This column lists the ASCII character.
3
SP is the SPACE character.
4
The Code 39 characters /P through /Y may be interchanged with the numbers 0 through 9.
5
%T may be interchanged with %X or %Y or %Z.
6 n is the Delete character.
Full ASCII Control Characters Table
Control Character
Definition
Control Character
Definition
NUL
Null or all zeroes
DC1
Device Control 1 (XON)
SOH
Start of Heading
DC2
Device Control 2
STX
Start of Text
DC3
Device Control 3 (XOFF)
ETX
End of Text
DC4
Device Control
EOT
End of Transmission
NAK
Negative Acknowledge
ENQ
Enquiry
SYN
Synchronous Idle
ACK
Acknowledgment
ETB
End Transmission Block
BEL
Bell
CAN
Cancel
BS
Backspace
EM
End of Medium
HT
Horizontal Tab
SUB
Substitute
LF
Line Feed
ESC
Escape
VT
Vertical Tab
FS
File Separator
FF
Form Feed
GS
Group Separator
CR
Carriage Return
RS
Record Separator
SO
Shift Out
US
Unit Separator
SI
Shift In
SP
Space
DLE
Data Link Escape
DEL
Delete
B-5
Page 262
TRAKKER Antares 246X Stationary Terminal User’s Manual nugget
39
Full ASCII Bar Code Chart The charts in this section list the Code 39 bar code label for each ASCII character. To use these bar code labels, you must configure the 246X terminal to use Code 39 in Full ASCII mode.
Control Characters NUL
*%U*
SOH
*$A*
STX
*$B*
*%U*
*$A*
*$B*
ETX
EOT
ENQ
*$C* *$C*
*$D*
*$D*
*$E*
ACK
BEL
BS
*$F*
*$G*
*$E*
*$H*
*$F*
*$G*
*$H*
HT
LF
VT
*$I*
*$J* *$J*
*$K*
FF
CR
SO
*$I*
*$L*
*$M*
*$K* *$N*
*$L*
*$M*
*$N*
SI
DLE
DC1
*$O*
*$P*
*$Q*
*$O*
*$P*
*$Q*
DC2
DC3
DC4
*$R*
*$S*
*$T*
*$R*
*$S*
*$T*
NAK
SYN
ETB
*$U* *$U*
B-6
*$V*
*$V*
*$W*
*$W*
Page 263
nugget
39 Full ASCII Charts
B
Control Characters (continued) CAN
*$X*
EM
*$Y*
SUB
*$Z*
*$X*
*$Y*
*$Z*
ESC
FS
GS
*%A*
*%B*
*%C*
RS
US
DEL
*%A*
*%D* *%D*
*%B*
*%E*
*%E*
*%C*
*%T*
*%T*
Symbols and Punctuation Marks ! (exclamation point)
" (quotation marks)
#
*/A*
*/B*
*/C*
$
%
&
*/A*
*/D*
*/B*
*/E*
*/C*
*/F*
*/D*
*/E*
*/F*
' (apostrophe)
(
)
*/G*
*/H*
*/I*
*/G*
*/H*
*/I*
* (asterisk)
+
- (dash)
*/J*
*/K*
*/M*
*/J*
*/K*
*/M*
/
=
. (period)
*/O*
*%H*
*/N*
, (comma)
: (colon)
; (semicolon)
*/O*
*/L* */L*
*%H*
*/Z*
*/Z*
*/N*
*%F*
*%F*
B-7
Page 264
TRAKKER Antares 246X Stationary Terminal User’s Manual nugget
39
Symbols and Punctuation Marks (continued) ?
*%J*
<
*%G*
>
*%I*
*%J*
*%G*
*%I*
@
[
]
*%V*
*%K*
*%M*
*%V*
*%K*
*%M*
~ (tilde)
^
_ (underline)
*%S*
*%N*
*%O*
*%S*
*%N*
*%O*
\
` (left single quote)
¦ (pipe)
*%L*
*%W*
*%Q*
*%L*
*%W*
*%Q*
{
}
Space
*%P*
*%R*
* *
0
1
2
*0*
*1*
*2*
3
4
5
*3*
*4*
*5*
6
7
8
*%P*
*%R*
**
Numbers
*0*
*3*
*6* *6* 9
*9* *9*
B-8
*1*
*4*
*7*
*7*
*2*
*5*
*8*
*8*
Page 265
Full ASCII Charts
Uppercase Letters
A MUA + A*
D AU *T)*
G AU *G*
J AMA *]*
M MUA *M*
P AAC *P*
S MU *G*
V AMA *V*
Y MUA aY%
B MATT *B*
E MU +At
H MUA *E*
K MUA Ke
N AAA *N*
Q AMA *O*
: AMA ¥T*
Ww MU Ww
Z AMA 47%
C MUA *C*
F TL +R
| MAT 47%
L AUT xy +
0 MU *O*
R MU AR*
U MU *U*
X AMA *\X*
B-9
Page 266
TRAKKER Antares 246X Stationary Terminal User’s Manual
Lowercase Letters a IL d TL g AUT | AUT m MUTT MN p AUT SS) MUTA V MUTA y MUA +4 Yr
B-10 b AUT MAT e MUA h AUT k AUT MTU n LIL q MUI t AUT W MUU
Z *47%
C MUA A f MUNI MC i LIU | AUT 0 Ln r MUTT U MUTI
X *4X*
Page 267
C Using the Default Applications
Page 268
blank page
Page 269
nugget Using the Default Applications
C
This appendix defines the APPTSK.BIN and EM9560.BIN applications that are shipped on the TRAKKER Antares terminals and explains how to use each application.
About the Applications Shipped on the Terminal The TRAKKER Antares terminal ships loaded with these two applications loaded on drive C: •
APPTSK.BIN
•
EM9560.BIN
This appendix explains how to use the APPTSK.BIN and EM9560.BIN applications on the terminal.
Defining APPTSK.BIN and EM9560.BIN You can run and use APPTSK.BIN or EM9560.BIN at any time. The two applications are defined as follows: This application is the default application on all TRAKKER Antares terminals. In some error conditions or if you exit an application, the terminal resets and runs APPTSK.BIN. You can use APPTSK.BIN to scan, enter, transmit, and display data. APPTSK.BIN
This application emulates a subset of the functionality available on the Intermec 95XX terminals, such as the 9512 and 9560. You can use EM9560.BIN to scan, enter, transmit, and display data. EM9560.BIN
APPTSK.BIN and EM9560.BIN include these features:
•
Works with any protocol that is supported on the terminal. Both the terminal and the device you are communicating with must use the same protocol (serial or Ethernet) and parameter settings.
•
Displays the time and date, which you can toggle on and off.
•
Sends scanned or keyboard data out all serial or Ethernet ports.
•
Buffers the keyboard data until you press Enter.
•
Receives data from any serial or Ethernet port, displays the data on the terminal screen, and parses the data for commands.
•
Receives data through any serial port and transmits it out the Ethernet port.
•
Receives data through the Ethernet port and transmits it out all serial ports.
The main difference between the two applications is that you can use the EM9560.BIN application to emulate specific functions of the 95XX terminals.
C-3
Page 270
TRAKKER Antares 246X Stationary Terminal User’s Manual nugget
Defining the Emulation Features of EM9560.BIN The TRAKKER Antares terminal is a programmable terminal that runs C/C++ applications. With the EM9560.BIN application, you can use the TRAKKER Antares terminal as a remote input/output terminal in which all prompts and commands are controlled by the host computer. With this application, the TRAKKER Antares terminal is similar to a 95XX terminal in Data Entry mode with no application running. Note: For the 95XX terminals, Data Entry mode with no application running is also referred to as an unprogrammed state or 95XX dumb terminal mode. The EM9560.BIN application allows you to use the TRAKKER Antares terminal to emulate these specific 95XX features:
C-4
•
An Enter key without any preceding data transmits an empty data packet.
•
The TRAKKER Antares terminal display is similar to but not identical to the 9560 buffered display mode.
•
All function keys transmit the corresponding characters F1, F2, and so on.
•
When Code 128 is configured for Standard Code 128 symbology and you scan a UCC/EAN label, the terminal will discard the Function 1 characters. Although this does not meet the industry standard for Code 128, it does emulate the 95XX terminal, which was manufactured before the current standard was established. Other Code 128 configurations work as defined in Chapter 8, “Configuration Command Reference.”
•
The High Beep reader command is supported. When a backslash character (\) is sent to the terminal through any serial or network port, the terminal sounds a high beep.
•
The Low Beep reader command is supported. When the BEL character is sent to the terminal through any serial or network port, the terminal sounds a low beep.
•
When control codes (ANSI escape sequences) are sent to the terminal through any serial or network port, the terminal formats the display. For a list of control codes, see “Using Display Control Codes” later in this appendix.
•
Preamble A, Preamble B, and Postamble C are supported through the AA, AB, and AC configuration commands or through the reader commands +., ++, and +%. For help, see “Setting Preambles and Postambles” later in this appendix.
•
Full ASCII mode for Code 39 can be configured through the CB or RB configuration commands or through the reader commands +$ and -$. For help, see “Full ASCII Mode for Code 39” later in this appendix.
•
The Exit Configuration Mode, Save Settings configuration command ($-) is not required, but bar code labels with this command scan correctly.