Page 321

Configuration Command Reference

9

Even Parity for COM4

*$+YB4.1* *$+YB4.1*

Or:

To set the parity for one serial port: 1. Scan this bar code: Enter Accumulate Mode / Set Parity

*+/$+YB* *+/$+YB*

2. Scan the serial port from these bar codes: COM1

COM4

*1.*

*4.*

*1.*

*4.*

3. Scan the parity from these bar codes: No Parity

Even Parity

*0*

*1*

*0*

*1*

Odd Parity

*2* *2*

4. Scan this bar code: Exit Accumulate Mode

*-/* *-/*

5. Repeat Steps 1 through 4 to set the parity for another serial port. Notes:

For COM1 only, you can use either command syntax listed next: Syntax: or:

YB1.data IBdata where data is a value from 0 to 2 for the parity. For COM4, you must use the YB configuration command.

9-71

Page 322

TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual

Plessey Purpose:

Enables or disables decoding of Plessey symbology. Plessey code is pulse-width modulated like most other bar codes. It includes a start character, data characters, an eight-bit cyclic check digit, a termination bar, and usually a reverse start character. The code is continuous and not self-checking. You need to configure two parameters for Plessey code: Start Code and Check Digit.

Syntax:

CIdata Acceptable values for data are: 00 10 30 31

Default: Scan:

Disabled Plessey with reverse start code Transmit check digit Discard check digit

Disabled To disable Plessey: Disable Plessey

*$+CI00* *$+CI00*

Or:

To set Plessey, complete these steps: 1. Scan this bar code: Plessey With Reverse Start Code

*$+CI10* *$+CI10*

2. Scan one of these bar codes to transmit or retain the check digit:

9-72

Transmit Check Digit

Discard Check Digit

*$+CI30*

*$+CI31*

*$+CI30*

*$+CI31*

Page 323

Configuration Command Reference

9

Poll (Polling) Purpose:

Solicits or requests data from a polled device. Note: Before you can enable Poll, you must configure the EOM and Handshake commands.

Syntax:

YRn.data where n is: 1 4

COM1 serial port COM4 serial port

Acceptable values for data are: Disabled Enabled Default: Scan:

No polling Set to FS (File Separator, hexadecimal value \x1c)

Disabled To disable poll, scan one of these bar codes: Disable Poll for COM1

*$+YR1.* *$+YR1.* Disable Poll for COM4

*$+YR4.* *$+YR4.*

Or:

To enable poll, scan one of these bar codes: Note: To scan these bar code labels, you must configure the T2455 to use Code 39 in Full ASCII mode. For help, see “Code 39” earlier in this chapter. Enable Poll (Set to FS) for COM1

*/D/KYR1/N/EB* *$+YR1.%B* Enable Poll (Set to FS) for COM4

*/D/KYR4/N/EB* *$+YR4.%B*

Note: FS is encoded as %B in a Code 39 bar code label.

9-73

Page 324

TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual

Poll (continued) Notes:

For COM1 only, you can use either command syntax listed next: Syntax: or:

YR1.data HBdata where data is disabled or enabled (set to FS). For COM4, you must use the YR configuration command.

Postamble Purpose:

Sets the postamble that is appended to any data you scan with the terminal. Common postambles include cursor controls such as tabs or carriage return line feeds. You can set the postamble to use characters from the extended ASCII character set such as the Field Exit code for 5250 TE. However, you cannot scan in extended ASCII characters in the Postamble command. You need to use the TRAKKER Antares 2400 Menu System. For help, see “Entering ASCII Control Characters” in Chapter 3.

Syntax:

AEdata Acceptable values for data are up to 25 ASCII characters. If you enter the AE command without data, the postamble is disabled. If you are entering quotation marks as data or grouping configuration commands, you need to enclose the data within quotation marks (see the example). Note: To scan a bar code label that includes quotes, you must configure the T2455 to use Code 39 in Full ASCII mode. For help, see “Code 39” earlier in this chapter.

Default: Scan:

No characters (disabled) To disable the postamble, scan this bar code: Disable Postamble

*$+AE* *$+AE*

Or:

To set the postamble to an ASCII character string: 1. Scan this bar code: Enter Accumulate Mode / Set Postamble

*+/$+AE* *+/$+AE*

9-74

Page 325

Configuration Command Reference

9

2. Scan a value for data from the “Full ASCII Bar Code Chart” in Appendix B. The postamble can be from 1 to 25 characters. 3. Scan this bar code: Exit Accumulate Mode

*-/* *-/*

Example:

You want to set a postamble that includes quotation marks. Enter the postamble by scanning this full ASCII bar code label: Set Postamble to “B”

*/D/KAE/B/B/BB/B/B/B* *$+AE"""B"""*

You must enclose the data within quotation marks and precede each quotation mark with another quotation mark so that the quotation marks are not treated as the end of the data.

Preamble Purpose:

Sets the preamble that precedes any data you scan with the terminal. Common preambles include a data location number or an operator number. You can set the preamble to use characters from the extended ASCII character. However, you cannot scan in extended ASCII characters in the Preamble command. You need to use the TRAKKER Antares 2400 Menu System. For help, see “Entering ASCII Control Characters” in Chapter 3.

Syntax:

ADdata Acceptable values for data are up to 25 ASCII characters. When you enter the AD command without data, the preamble is disabled. If you are entering quotation marks as data or grouping configuration commands, you need to enclose the data within quotation marks (see the example). Note: To scan a bar code label that includes quotes, you must configure the T2455 to use Code 39 in Full ASCII mode. For help, see “Code 39” earlier in this chapter.

Default:

No characters (disabled)

9-75

Page 326

TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual

Preamble (continued) Scan:

To disable the preamble, scan this bar code: Disable Preamble

*$+AD* *$+AD*

Or:

To set the preamble to an ASCII character string: 1. Scan this bar code: Enter Accumulate Mode / Set Preamble

*+/$+AD* *+/$+AD*

2. Scan a value for data from the “Full ASCII Bar Code Chart” in Appendix B. The preamble can be from 1 to 25 characters. 3. Scan this bar code: Exit Accumulate Mode

*-/* *-/*

Example:

You want to set a preamble that includes quotation marks. Enter the preamble by scanning this full ASCII bar code label: Set Preamble to “B”

*/D/KAD/B/B/BB/B/B/B* *$+AD"""B"""*

You must enclose the data within quotation marks and precede each quotation mark with another quotation mark so that the quotation marks are not treated as the end of the data.

9-76

Page 327

Configuration Command Reference

9

RAM Drive Size Purpose:

Configures the size and use of the RAM drive (E). You can disable the RAM drive and use the additional 256K for programmable (Malloc) memory allocations or configure the RAM drive to temporarily store data and files. Important: After you set the RAM drive, you must save the configuration in flash memory and boot the terminal for the change to take effect. Note: When you boot or reset the terminal, all files on the RAM drive are destroyed.

Syntax:

FRdata Acceptable values for data are: 0 16-256

Default: Scan:

Disabled, no RAM drive RAM drive size in kilobytes (K)

0 To disable the RAM drive, scan this bar code: Disable RAM Drive

*$+FR0* *$+FR0*

Or:

To set the RAM drive size: 1. Scan this bar code: Enter Accumulate Mode / Set RAM Drive Size

*+/$+FR* *+/$+FR*

2. Scan a numeric value for data from these bar codes:

*0*

*1*

*0*

*1*

*2*

*3*

*2*

*3*

*4*

*5*

*4*

*5*

9-77

Page 328

TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual

RAM Drive Size (continued)

*6*

*7*

*6*

*7*

*8*

*9*

*8*

*9*

3. Scan this bar code: Exit Accumulate Mode

*-/* *-/*

4. Scan this bar code to save the configuration change in flash memory: Save Configuration in Flash Memory

*.+1* *.+1*

5. Scan this bar code to boot the terminal and use the RAM drive: Reset Firmware

*-.* *-.*

Resume Execution Purpose:

f to turn on the • If you set this parameter to resume not allowed, when you press f to turn on the Defines the way in which the terminal resumes when you press terminal:

terminal, the terminal boots and restarts the application that was running when you turned off the terminal.

•

Syntax:

f

If you set this parameter to resume allowed, when you press to turn on the terminal, the terminal resumes exactly where it was when you turned off the terminal.

ERdata Acceptable values for data are: 0 1

9-78

Not allowed Allowed

Page 329

Configuration Command Reference

Default: Scan:

9

Allowed One of these bar codes: Resume Execution Not Allowed

*$+ER0* *$+ER0* Resume Execution Allowed

*$+ER1* *$+ER1*

RF Domain Purpose:

Defines a logical partition or subnetwork of the network. To establish communications, you must assign the same domain number to every RF device in a wireless network. The domain number you set on the T2455 must match the domain that is set on each access point the T2455 may communicate with. You can continue to collect data with the T2455 as you roam in between access points as long as all the devices have the same domain number.

Syntax:

RWdata Acceptable values for data are any number from 0 to 15.

Default: Scan:

0 1. Scan this bar code: Enter Accumulate Mode / Set RF Domain

*+/$+RW* *+/$+RW*

2. Scan a numeric value for data from these bar codes:

*0*

*1*

*0*

*1*

*2*

*3*

*2*

*3*

*4*

*5*

*4*

*5*

9-79

Page 330

TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual

RF Domain (continued)

*6*

*7*

*6*

*7*

*8*

*9*

*8*

*9*

3. Scan this bar code: Exit Accumulate Mode

*-/* *-/*

RF Inactivity Timeout Purpose:

Defines the amount of time the radio on the T2455 waits to go into a low power state. If no data is sent or received within the RF inactivity timeout period set, the radio goes into a low power state to conserve power. If you set a high value, the radio stays on longer at a higher power rate and uses power at a faster rate. Power Management Tip: Intermec strongly recommends that you use the optimum RF inactivity timeout of 5 seconds to preserve power.

Syntax:

RYdata Acceptable values for data are: 0 1-51

Radio never turns off RF inactivity timeout in seconds multiplied by a value of 5 where data=1 sets a timeout delay of 5 seconds, data=2 sets a timeout delay of 10 seconds, and so on, up to data=51 for a timeout delay of 255 seconds. Default: Scan:

5 seconds To set the default RF inactivity timeout to 5 seconds, scan this bar code: Default RF Inactivity Timeout

*$+RY1* *$+RY1*

9-80