Page 281
Configuration Command Reference
9
Command Processing Purpose:
Command processing allows you to disable or enable reader commands. For example, you can disable the Delete File command. There are two ways to enable or disable reader commands: •
Use the Command Processing configuration command described here.
•
Use the Reader Command Menu option in the Configuration Menu of the TRAKKER Antares 2400 Menu System.
You may want to disable reader commands to prevent a user from accidentally entering a command, or to use data that would otherwise be treated as a command. Any Code 39 or Code 93 bar code label that contains the 2 to 4-character commands for Command Processing is treated as a reader command unless the command is disabled. If you want to disable or enable several commands, it is easier to use the menu system. For help, see Chapter 3, “Configuring the Terminal.” For a description of each reader command that you can enable or disable with Command Processing, see Chapter 8, “Reader Command Reference.” Syntax:
DCdata Acceptable values for data are: 0 1 2 3 command0 command1
Disable all reader commands Enable all reader commands Disable override Enable override Disable reader command Enable reader command
The override option is a temporary setting that allows you to enable all the reader commands for as long as you need them. When you want to return to the previous configuration, you disable the override. Note: The Enable Override option is the only bar code label you can scan to enable reader commands if you have disabled all reader commands (DC0). You can also enable reader commands in the TRAKKER Antares 2400 Menu System. Default: Scan:
All reader commands enabled To enable all the reader commands or override the current settings, scan one of these bar codes: Disable All Reader Commands
Enable All Reader Commands
*$+DC0*
*$+DC1*
*$+DC0*
*$+DC1*
9-31
Page 282
TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual
Command Processing (continued)
Or:
Disable Override
Enable Override
*$+DC2*
*$+DC3*
*$+DC2*
*$+DC3*
To disable or enable specific reader commands, perform these steps: 1. Scan this bar code: Enter Accumulate Mode / Command Processing
*+/$+DC* *+/$+DC*
2. Scan the bar code to disable or enable one reader command. Note: If there are two bar codes for a reader command, you must scan them in order, left to right. Accumulate mode commands are separated into two bar codes so that the command can be accumulated rather than executed as a command. Abort Program
*/$* */$*
9-32
Backspace
(continued)
*-*
*+*
*-*
*+*
Boot Terminal
Change Configuration
*-.1*
*$+*
*-.1*
*$+*
Clear
(continued)
*-*
*-*
*-*
*-*
Default/Save Configuration
Delete File
*.+*
*..--*
*.+*
*..--*
Enter Accumulate Mode
(continued)
*+*
*/*
*+*
*/*
Page 283
Configuration Command Reference
Exit Accumulate Mode
(continued)
*-*
*/*
*-*
*/*
Receive File
Rename File
*.%*
*...-*
*.%*
*...-*
Reset Firmware
Run Program
*-.*
*//*
*-.*
*//*
Set Time and Date
Status Lights Control
*/+*
*$%*
/+
*$%*
Test and Service Mode
Transmit File
*..-.*
*%%*
*..-.*
*%%*
9
3. Scan one of these bar codes: Disable the Command
Enable the Command
*0*
*1*
*0*
*1*
4. Repeat Steps 2 and 3 to disable or enable another reader command. Note: You can accumulate up to 250 characters in the buffer. If the data accumulated exceeds 250 characters, you will hear an error beep and the terminal will reject the last bar code read. 5. Scan this bar code: Exit Accumulate Mode
*-/* *-/*
Or:
To disable or enable the ability to scan multiple-read labels, scan one of these bar codes: Disable Multiple-Read Labels
Enable Multiple-Read Labels
*$+DC 0*
*$+DC 1*
*$+DC 0*
*$+DC 1*
9-33
Page 284
TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual
Configuration Commands Via Serial Port Purpose:
Allows you to control the data the terminal receives through the serial port. You can set this command to execute reader and configuration commands received through the serial port, or treat all data as data without checking for special command syntax. There are three options: Disabled All data received through the serial port is treated as data. The terminal will not execute reader or configuration commands sent or encoded in the data. Enabled with TMF If the data is sent with the TMF (Terminal Message Format) header, the terminal will check for and execute the TMF command received through the serial port. With TMF, you can execute reader and configuration commands, or send and receive data about the current terminal configuration. Enabled without TMF The terminal will check for and execute all reader and configuration commands (i.e., Receive File reader command or Beep Volume change configuration command). Note: Before you can enable Configuration Commands Via Serial Port with or without TMF, you must configure the EOM command.
Syntax:
YTn.data where n is: 1 4
COM1 serial port COM4 serial port
Acceptable values for data are: 0 1 2 Default: Scan:
Disabled Enabled with TMF Enabled without TMF
Enabled without TMF To set the default for each serial port, scan these bar codes: COM1 Commands Via Serial Port Enabled Without TMF
*$+YT1.2* *$+YT1.2* COM4 Commands Via Serial Port Enabled Without TMF
*$+YT4.2* *$+YT4.2*
9-34
Page 285
Configuration Command Reference
Or:
9
To set the configuration commands via serial port for one serial port: 1. Scan this bar code: Enter Accumulate Mode / Set Configuration Commands Via Serial Port
*+/$+YT* *+/$+YT*
2. Scan the serial port from these bar codes: COM1
COM4
*1.*
*4.*
*1.*
*4.*
3. Scan a numeric value for data from these bar codes: Disabled
Enabled With TMF
*0*
*1*
*0*
*1*
Enabled Without TMF
*2* *2*
4. Scan this bar code: Exit Accumulate Mode
*-/* *-/*
5. Repeat Steps 1 through 4 to set the configuration commands via serial port for another serial port. Notes:
For COM1 only, you can use either command syntax listed next: Syntax: or:
YT1.data ITdata where data is a value from 0 to 2. For COM4, you must use the YT configuration command.
9-35
Page 286
TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual
Controller Connect Check Receive Timer Purpose:
During periods of inactivity on the T2455, the terminal still sends messages to the DCS 300 or the Model 200 Controller to check the RF connection. If no message is received within the time set for the Controller Connect Check Receive Timer, the terminal is no longer connected to the DCS 300 or the controller and the Network Connect status light blinks. The timer countdown resets each time a valid message is received. Power Management Tip: Intermec strongly recommends that you use the optimum setting of 60 seconds.
Syntax:
NPdata Acceptable values for data are any number from 1 to 3600 seconds (60 minutes).
Default: Scan:
60 seconds To set the default controller connect check receive timer, scan this bar code: Default Controller Connect Check Receive Timer
*$+NP60* *$+NP60*
Or:
To set the controller connect check receive timer: 1. Scan this bar code: Enter Accumulate Mode / Set Controller Connect Check Receive Timer
*+/$+NP* *+/$+NP*
2. Scan a numeric value for data from these bar codes:
9-36
*0*
*1*
*0*
*1*
*2*
*3*
*2*
*3*
*4*
*5*
*4*
*5*
Page 287
Configuration Command Reference
*6*
*7*
*6*
*7*
*8*
*9*
*8*
*9*
9
3. Scan this bar code: Exit Accumulate Mode
*-/* *-/*
Controller Connect Check Send Timer Purpose:
During periods of inactivity on the T2455, the terminal still sends messages to the DCS 300 or the Model 200 Controller to check the RF connection. The terminal sends a message at the time interval set for the Controller Connect Check Send Timer. The timer countdown resets each time a valid message is sent or received. Power Management Tip: Intermec strongly recommends that you use the optimum setting of 35 seconds.
Syntax:
NQdata Acceptable values for data are any number from 1 to 3600 seconds (60 minutes).
Default: Scan:
35 seconds To set the default controller connect check send timer, scan this bar code: Default Controller Connect Check Send Timer
*$+NQ35* *$+NQ35*
Or:
To set the controller connect check send timer: 1. Scan this bar code: Enter Accumulate Mode / Set Controller Connect Check Send Timer
*+/$+NQ* *+/$+NQ*
9-37
Page 288
TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual
Controller Connect Check Send Timer (continued) 2. Scan a numeric value for data from these bar codes:
*0*
*1*
*0*
*1*
*2*
*3*
*2*
*3*
*4*
*5*
*4*
*5*
*6*
*7*
*6*
*7*
*8*
*9*
*8*
*9*
3. Scan this bar code: Exit Accumulate Mode
*-/* *-/*
9-38
Page 289
Configuration Command Reference
9
Controller IP Address Purpose:
Defines the IP address assigned to the DCS 300 or the Model 200 Controller in your 2.4 GHz RF network. An IP address is a network level address you assign to each device in a TCP/IP network. The controller IP address you set on the T2455 must match the address that is set on the DCS 300 or the controller. If you plan to enable DHCP (Dynamic Host Configuration Protocol), you can set the controller IP address to any valid IP address. The T2455 will locate and reset the IP address after you enable DHCP. For help, see “Dynamic Host Configuration Protocol” later in this chapter.
Syntax:
NCn.n.n.n where each n address segment is a number from 0 to 255. The controller IP address field consists of four separate numbers, each separated by a period. Note: The RF network cannot be activated if the first address segment in the IP address is set to 0, 127, or a number greater than 223.
Default: Scan:
0.0.0.0 To set the default controller IP address, scan this bar code: Default Controller IP Address
*$+NC0.0.0.0* *$+NC0.0.0.0*
Or:
To set the controller IP address: 1. Scan this bar code: Enter Accumulate Mode / Set Controller IP Address
*+/$+NC* *+/$+NC*
2. Scan a numeric value from 0 to 255 to set an n field of the controller IP address from these bar codes.
*0*
*1*
*0*
*1*
*2*
*3*
*2*
*3*
9-39
Page 290
TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual
Controller IP Address (continued)
*4*
*5*
*4*
*5*
*6*
*7*
*6*
*7*
*8*
*9*
*8*
*9*
3. Scan this bar code: . (Period)
*.* *.*
4. Repeat Steps 2 and 3 to set the next three numbers in the controller IP address field. After you scan the last address segment, go to Step 5. Do not scan the period after the last address segment. 5. Scan this bar code: Exit Accumulate Mode
*-/* *-/*
Data Bits Purpose:
Sets the number of data bits the terminal uses when communicating with another device (i.e., host computer) through the serial port.
Syntax:
YIn.data where n is: 1 4
COM1 serial port COM4 serial port
Acceptable values for data are: 7 8 Default:
9-40
7