The text of a manual · part 26 of 43
TRAKKER Antares 2455 Vehicle-Mount Terminal User's Manual, pages 251 to 260
Pages 251 to 260 of 422
The original document is the PDF (1.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 2455
Page 251
9 Configuration Command Reference
Page 252
Page 253
Configuration Command Reference
9
This chapter is an alphabetical list of all the configuration commands supported on the terminal.
Using Configuration Commands A configuration command changes the way the terminal operates. For example, you can change the Beep Volume and make the terminal beep very loud in a noisy environment. You can execute configuration commands by • scanning a command from a Code 39 or Code 93 bar code label. The labels are provided in this chapter. For more help, see Chapter 3, “Configuring the Terminal.”
• choosing a command from the TRAKKER Antares 2400 Menu System. For help, see Chapter 3, “Configuring the Terminal.”
• sending a command from a device on the serial or RF network. For help, see “Using Serial Communications on the Terminal” and “Using RF Communications on the Terminal” in Chapter 4.
Note: If you are working in the TRAKKER Antares 2400 Menu System, you cannot scan configuration commands. Exit the menu system to scan configuration commands. You can find the following information about each configuration command in this chapter: •
Command description and purpose
•
Command syntax and options
•
Default setting
•
Bar code labels you can scan to set or change each command
The configuration commands are listed alphabetically by command name. For a list of bar code symbology, operations, RF network communications, or serial network communications commands, use the next table, “Configuration Commands Listed by Category.” If you want to look up a command by its syntax, see the “Configuration Commands by Syntax” list in Appendix A. Some of the bar code labels in this chapter include quotes or other characters from the full ASCII character set. To scan these bar code labels, you must configure the T2455 to use Code 39 in Full ASCII mode. For help, see “Code 39” later in this chapter. Note: The Code 39 bar code labels in this chapter show an asterisk (*) at the beginning and end of the human-readable interpretation to represent the start and stop codes. If you are creating your own Code 39 bar code labels, your bar code printing utility may automatically supply the asterisks as the start/stop code.
9-3
Page 254
TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual
Configuration Commands Listed by Category This chapter lists the configuration commands in alphabetical order. Use this next list to find the configuration commands you may need to set for bar code symbologies, operations, RF network communications, or serial network communications. Bar Code Symbologies
Operations
Codabar, 9-14
Append Time, 9-9
Code 11, 9-15
Automatic Shutoff, 9-10
Code 16K, 9-16
Beep Volume, 9-13
Code 2 of 5, 9-17
Command Processing, 9-31
Code 39, 9-18
Decode Security, 9-42
Code 49, 9-22
Display Contrast, 9-45
Code 93, 9-23
Display Font Type, 9-46
Code 128, 9-24
Display Row Spacing, 9-47
Interleaved 2 of 5, 9-59
Display Video Mode, 9-48
MSI, 9-66
Flash Memory Configuration, 9-52
Plessey, 9-72
Keypad Caps Lock, 9-61
UPC/EAN, 9-106
Keypad Clicker, 9-61 Keypad Type, 9-62 Postamble, 9-74 Preamble, 9-75 RAM Drive Size, 9-77 Resume Execution, 9-78 Scan Ahead, 9-85 Scanner Mode, 9-86 Scanner Redundancy, 9-88 Scanner Selection, 9-89 Scanner Timeout, 9-90 Scanner Trigger, 9-91 Suspend/Resume Control, 9-98 Time and Date, 9-102 Time in Seconds, 9-104
9-4
Page 255
Configuration Command Reference
RF Network Communications
Serial Network Communications
Acknowledgement Delay Lower Limit, 9-7
Baud Rate, 9-11
Acknowledgement Delay Upper Limit, 9-8
Configuration Commands Via Serial Port, 9-34
Controller Connect Check Receive Timer, 9-36
Data Bits, 9-40
Controller Connect Check Send Timer, 9-37
End of Message (EOM), 9-50
Controller IP Address, 9-39
Flow Control, 9-53
Default Router, 9-43
Handshake, 9-55
Dynamic Host Configuration Protocol (DHCP), 9-49
LRC (Longitudinal Redundancy Check), 9-63
Host IP Address, 9-57
Parity, 9-70
Maximum Retries, 9-64
Poll (Polling), 9-73
Network Activate, 9-67
Scanner Port (COM4), 9-87
Network Loopback, 9-68
Serial Port Protocol, 9-92
Network Port, 9-69
Start of Message (SOM), 9-94
RF Domain, 9-79
Stop Bits, 9-95
RF Inactivity Timeout, 9-80
Timeout Delay, 9-104
9
RF Roaming Flag, 9-82 RF Security Identification (ID), 9-82 RF Transmit Mode, 9-84 RF Wakeup On Broadcast, 9-85 Subnet Mask, 9-96 TCP Maximum Retries, 9-98 TCP/IP Maximum Transmit Timeout, 9-99 Terminal IP Address, 9-101
9-5
Page 256
TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual
Entering Variable Data in a Configuration Command You can enter variable data for many of the configuration commands. For example, you can set a preamble that is up to 25 ASCII characters long. You need to follow these general instructions to enter variable data. To enter variable data in a configuration command 1. Scan a bar code label with this syntax: +/$+command where: +/ is the syntax for the Enter Accumulate Mode command.
$+ is the syntax for the Change Configuration command.
command is the syntax for the command you want to change.
For example, the command syntax for a preamble is ADdata. To change or set a preamble, scan this bar code: Enter Accumulate Mode / Change Configuration / Set Preamble
*+/$+AD* *+/$+AD*
2. Scan a bar code label from the “Full ASCII Bar Code Chart” in Appendix B. To set the preamble to the character T, scan this label: T
*T* *T*
Note: To use the bar code labels in Appendix B, you must configure the T2455 to use Code 39 in Full ASCII mode. For help, see “Code 39” later in this chapter. 3. Scan the Exit Accumulate Mode bar code label to update the terminal’s configuration: Exit Accumulate Mode
*-/* *-/*
9-6
Page 257
Configuration Command Reference
9
Acknowledgement Delay Lower Limit Purpose:
When the T2455 sends a message to the DCS 300 or the Model 200 Controller, the terminal waits to receive a response acknowledging the message. If no response is received within the Acknowledgement Delay Lower Limit time, the terminal sends the message again at the time interval set for the lower limit. The terminal will continue to send the data at increasingly longer intervals until it reaches the Acknowledgement Delay Upper Limit time. The terminal continues sending the message at the time interval set for the upper limit until a response is received or a timeout error occurs.
Syntax:
NVdata Acceptable values for data are any number from 200 to 2000 ms.
Default: Scan:
300 ms To set the default acknowledgement delay lower limit, scan this bar code: Default Acknowledgement Delay Lower Limit
*$+NV300* *$+NV300*
Or:
To set the acknowledgement delay lower limit: 1. Scan this bar code: Enter Accumulate Mode / Set Acknowledgement Delay Lower Limit
*+/$+NV* *+/$+NV*
2. Scan a numeric value for data from these bar codes:
*0*
*1*
*0*
*1*
*2*
*3*
*2*
*3*
*4*
*5*
*4*
*5*
*6*
*7*
*6*
*7*
9-7
Page 258
TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual
Acknowledgement Delay Lower Limit (continued)
*8*
*9*
*8*
*9*
3. Scan this bar code: Exit Accumulate Mode
*-/* *-/*
Acknowledgement Delay Upper Limit Purpose:
When the T2455 sends a message to the DCS 300 or the Model 200 Controller, the terminal waits to receive a response acknowledging the message. If no response is received within the Acknowledgement Delay Lower Limit time, the terminal sends the message again at the time interval set for the lower limit. The terminal will continue to send the data at increasingly longer intervals until it reaches the Acknowledgement Delay Upper Limit time. The terminal continues sending the message at the time interval set for the upper limit until a response is received or a timeout error occurs.
Syntax:
NUdata Acceptable values for data are any number from 2000 to 60000 ms.
Default: Scan:
5000 ms To set the default acknowledgement delay upper limit, scan this bar code: Default Acknowledgement Delay Upper Limit
*$+NU5000* *$+NU5000*
Or:
To set the acknowledgement delay upper limit: 1. Scan this bar code: Enter Accumulate Mode / Set Acknowledgement Delay Upper Limit
*+/$+NU* *+/$+NU*
9-8
Page 259
Configuration Command Reference
9
2. Scan a numeric value for data from these bar codes:
*0*
*1*
*0*
*1*
*2*
*3*
*2*
*3*
*4*
*5*
*4*
*5*
*6*
*7*
*6*
*7*
*8*
*9*
*8*
*9*
3. Scan this bar code: Exit Accumulate Mode
*-/* *-/*
Append Time Purpose:
Appends the time to bar code labels that are scanned into the terminal. You can also use the Time in Seconds command to append the time in hours and minutes only, or hours, minutes, and seconds. The time is appended to the data in the form HH:MM:SS. For help, see “Time in Seconds” later in this chapter.
Syntax:
DEdata Acceptable values for data are: 0 1
Default: Scan:
Disabled Enabled
Disabled One of these bar codes: Disable Append Time
Enable Append Time
*$+DE0*
*$+DE1*
*$+DE0*
*$+DE1*
9-9
Page 260
TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual
Automatic Shutoff Purpose:
Defines the maximum length of time the terminal remains on when there is no activity. When you do not use the terminal for the length of time set with this command, the terminal automatically turns off as if you had pressed to turn it off.
f f
When you press to turn on the terminal, the terminal either resumes exactly where it was when you turned it off or the terminal boots and restarts your application. Resume is controlled through the Resume Execution command. For help, see “Resume Execution” later in this chapter. Syntax:
EZdata Acceptable values for data are: 0 02-75
Default: Scan:
Disabled (always on) Shutoff time in minutes
0 (disabled) To disable automatic shutoff, scan this bar code: Disable Automatic Shutoff
*$+EZ0* *$+EZ0*
Or:
To set a timeout: 1. Scan this bar code: Enter Accumulate Mode / Set Automatic Shutoff
*+/$+EZ* *+/$+EZ*
2. Scan a numeric value for data from these bar codes:
9-10
*0*
*1*
*0*
*1*
*2*
*3*
*2*
*3*
*4*
*5*
*4*
*5*