Page 221
Nugg
Running Diagnostics Co de 39
Error Number
Message
0x185
Seek not permitted from Append mode
0x186
Read not permitted in write only file
0x191
Duplicate drive letter
0x192
Invalid drive letter
0x193
Duplicate file name
0x194
Invalid file name
0x195
Directory full
0x196
Disk full
0x197
Invalid file control block
0x198
Invalid seek mode
0x199
Different drives
0x19A
End of file
0x19B
Drive table full
0x19C
File system error
0x19D
Invalid seek offset mode combination
0x1D0
Application load error
0x1D1
Application load error
0x1E0
Application load error
0x1E1
Application load error
0x1E0
Application load error
0x1F0
Add Decode - The Decode symbology is already present in the auto-discrimination table.
0x1F1
Drop Decode - The Decode symbology was not found in the auto-discrimination table.
0x1F2
Intermediate row which was already read
0x1F3
Intermediate row successfully decoded
0x1F4
Command symbology (Code 39)
0x1F5
Code39 half-ASCII
0x1F6
Good decode
0x1F7
Label has already been read this trigger pull
0x1F8
Votes aren't all in for the label
0x1F9
Get config character returned a quoted quote
0x200
Decodes auto-discrimination table full
7
7-29
Page 222
TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual Nugg Co de 39
Error Numbers and Messages Table (continued)
7-30
Error Number
Message
0x201
Decode Data command error: Not enough resources to attempt to decode the counts.
0x202
Invalid Decodes command
0x203
Invalid Decode symbology specified
0x204
Unable to decode input scan
0x205
Missing start or stop character
0x206
Number of counts less than minimum
0x207
Invalid character found
0x208
Invalid acceleration between characters
0x20A
Label length less than minimum
0x20B
Incorrect check digit
0x20C
Output string too short
0x20D
Leading margin not found
0x20E
Invalid start or stop pattern
0x20F
Not enough counts for whole label
0x210
Missing trailing margin
0x211
Invalid supplement to UPC label
0x212
Parity error while decoding character
0x213
Guard character not found
0x214
Invalid row number (Code 49 or Code 16K)
0x215
Unable to scale counts buffer
0x216
Error in 2 of 5 label
0x217
Wrong length 2 of 5 label
0x218
Longer than maximum 2 of 5 label length
0x219
Valid label region not found
0x21A
Ink spread exceeded threshold
0x21B
The denominator of an expression is 0
0x21C
ASCIIfication of Full ASCII failed
0x21D
Raw scan buffer. No decode attempted yet
0x21E
Field is full no more input allowed until this is returned
Page 223
Nugg
Running Diagnostics Co de 39
7
Error Number
Message
0x21F
Address not in the application data space range.
0x221
Movement direction parameter invalid, not one of four viewport directions
0x222
End of display block outside virtual display
0x223
A printable keycode was passed in a command to set manual movement
0x224
Both start and end outside of virtual display
0x225
First parameter to function invalid
0x226
Invalid com source number i.e. > E_NET
0x227
Input requested with no valid source to receive it from
0x228
Start of display block outside virtual display
0x22A
PSK coding error
0x22B
Network error
0x22C
No description available
0x22D
Informational: Follow Cursor mode not enabled
0x22E
The cursor detection value in a set follow cursor command is larger than
0x230
The viewport movement value is larger than the viewport size
0x231
Data transmitted before cancel request accepted
0x241
Data entered does not match mask type
0x4233
Informational: returned due to function key 1 pressed
0x4234
Informational: returned due to function key 2 pressed
0x4235
Informational: returned due to function key 3 pressed
0x4236
Informational: returned due to function key 4 pressed
0x4237
Informational: returned due to function key 5 pressed
0x4238
Informational: returned due to function key 6 pressed
0x4239
Informational: returned due to function key 7 pressed
0x423A
Informational: returned due to function key 8 pressed
0x423B
Informational: returned due to function key 9 pressed
0x423C
Informational: returned due to function key 10 pressed
0x423D
Informational: returned due to tab key pressed
0x423E
Informational: returned due to back tab key pressed
0x4240
Informational: returned due to escape key pressed
0x4242
Informational: returned due to Up Arrow key pressed
0x4243
Informational: returned due to Down Arrow key pressed
7-31
Page 224
TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual Nugg Co de 39
Error Numbers and Messages Table (continued)
7-32
Error Number
Message
0x5220
Both row and column in viewport set XY invalid but adjusted to end
0x5229
Informational browse mode active
0x522F
Attempted to cancel transmit buffer that was never called before
0x5232
Viewporting is turned off-physical and virtual screens same size
0x523F
Informational: Viewport moved as far as possible hitting edge
0x250
NMI for keypad received prior to vector
0x251
NMI for PMU received prior to vector
0x260
SpOpen not previously called successfully
0x261
The port handle is unknown to CSP
0x262
Control block pointer is NULL
0x263
Port is not valid
0x264
Unknown mode
0x265
Another CSP client has called SpOpen
0x266
Data pointer is NULL
0x267
Frame mode configuration error
0x268
SOM configured, but no EOM configured
0x269
SOM = EOM1 or SOM = EOM2, both invalid
0x26A
SOM, EOM1, or EOM2 set to invalid character (DLE, XON, XOFF)
0x26B
EOM1 = EOM2, invalid
0x26C
Suspend Resume cycle occurred.
0x26D
Protocol ran out of retries.
0x26E
Configuration change caused reset.
0x26F
Receive error in packet
0x270
Library does not exist
0x271
BIN not in library
0x272
No relocatable BIN header
0x280
Modem returned OK
0x281
Modem operation failed
0x282
No carrier detected
0x283
No dial tone
0x284
Line is busy
Page 225
Nugg
Running Diagnostics Co de 39
Error Number
Message
0x285
No answer
0x286
No CTS from modem
0x287
Modem returned error
0x288
Modem speed incorrect
0x289
Check modem speed
0x300
Keypad 'HOT KEY' 0 has a NULL pointer to a far routine
0x301
Keypad 'HOT KEY' 1 has a NULL pointer to a far routine
0x302
Keypad 'HOT KEY' 2 has a NULL pointer to a far routine
0x303
Keypad 'HOT KEY' 3 has a NULL pointer to a far routine
0x304
Keypad 'HOT KEY' 4 has a NULL pointer to a far routine
0x305
Keypad 'HOT KEY' 5 has a NULL pointer to a far routine
0x306
Keypad 'HOT KEY' 6 has a NULL pointer to a far routine
0x307
Keypad 'HOT KEY' 7 has a NULL pointer to a far routine
0x308
Keypad 'HOT KEY' 8 has a NULL pointer to a far routine
0x309
Keypad 'HOT KEY' 9 has a NULL pointer to a far routine
0x30A
Keypad 'HOT KEY' 10 has a NULL pointer to a far routine
0x30B
Keypad 'HOT KEY' 11 has a NULL pointer to a far routine
0x30C
Keypad 'HOT KEY' 12 has a NULL pointer to a far routine
0x30D
Keypad 'HOT KEY' 13 has a NULL pointer to a far routine
0x30E
Keypad 'HOT KEY' 14 has a NULL pointer to a far routine
0x30F
Keypad 'HOT KEY' 15 has a NULL pointer to a far routine
0x310
PIC interface error
0x311
Battery value not valid due to charging
0x330
Unexpected interrupt
0x331
Divide by zero
0x332
INT0 detected overflow exception
0x333
Array bounds exception
0x334
Unused opcode exception
0x335
Escape opcode exception
0x336
Unused int 7E subsystem
0x337
Check for powerdown
0x340
MultiDrop or Polling Mode D protocol error
0x341
Bus error
7
7-33
Page 226
TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual Nugg Co
Error Numbers and Messages Table (continued)
7-34
Error Number
Message
0x342
Bus not available
0x343
Bus write acknowledge timeout
0x344
XOFF prevents CSP TX
0x345
Reset from master interrupts CSP TX de 39
Page 227
8 Reader Command Reference
Page 228
Page 229
Reader Command Reference
8
This chapter describes the reader commands that you can use while operating the terminal. Reader commands, such as Change Configuration, allow you to perform a task on the terminal.
Using Reader Commands A reader command causes the terminal to perform a task. Some reader commands temporarily override the configuration settings and some actually change the configuration settings. For example, you can reset the terminal to the default configuration or change the configuration. You can execute reader commands by • scanning a command from a Code 39 or Code 93 bar code label.
• pressing keys on the keyboard or choosing a command from the TRAKKER Antares 2400 Menu System.
• sending a command from a device on the serial or RF network.
There are three general types of reader commands: •
Accumulate mode commands
•
Operating commands
•
File management commands
The reader commands are listed in alphabetical order within these three categories. You will find the purpose, command syntax, and bar code labels for each reader command in this chapter. Note: The Code 39 bar code labels in this chapter show an asterisk (*) at the beginning and end of the human-readable interpretation to represent the start and stop codes. If you are creating your own Code 39 bar code labels, your bar code printing utility may automatically supply the asterisks as the start/stop code.
Using Accumulate Mode You can use Accumulate mode to collect data from a series of bar code labels and enter them as a single label. When you put the terminal in Accumulate mode, the terminal will collect all scanned bar code labels in the terminal’s buffer until you scan either the Enter or Exit Accumulate mode command. As you accumulate the data from bar code labels, the data is visible on the bottom line of the screen. You can edit the accumulated data with the Backspace, Clear, and Enter commands.
8-3
Page 230
TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual
Backspace This command deletes the last character from the current data record you are accumulating. Clear
This command deletes the entire data record you are accumulating.
Enter This command will enter data as a record and leaves the terminal in Accumulate mode. Note: If you are not in Accumulate mode, the Backspace, Clear, and Enter commands have no effect and you will hear an error beep. When you exit Accumulate mode, the accumulated data is “entered” as a data record. Up to 250 characters can be held in the buffer. If the data record count exceeds 250 characters, the data is truncated. If you reset the terminal (software or hardware reset), you exit Accumulate mode, the entire buffer is cleared, and all data accumulated is lost. To use Accumulate mode The syntax to use the Enter Accumulate command is: +/data where: +/ is the syntax for the Enter Accumulate mode command.
data is the optional data you want to enter. Data can be a reader command that is executed when you exit Accumulate mode.
1. Scan this bar code label to Enter Accumulate mode: Enter Accumulate Mode
*+/* *+/*
2. Scan the bar code label(s) for the data you want to enter. You can scan labels from the “Full ASCII Bar Code Chart” in Appendix B. For example, scan this label to change the terminal’s configuration and set the preamble to the characters ABC. Change Configuration / Set Preamble to ABC
*$+ADABC* *$+ADABC*
8-4