The text of a manual · part 14 of 43
TRAKKER Antares 2455 Vehicle-Mount Terminal User's Manual, pages 131 to 140
Pages 131 to 140 of 422
The original document is the PDF (1.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 2455
Page 131
nugget CODE39 Operating the Terminal in a Network
4
TRAKKER Antares 2455 Terminals Communicating Across Subnetworks (UDP Plus) DCS 300 192.9.200.5 192.9.200.X subnetwork
Router
192.9.175.X subnetwork Ethernet
192.9.175.1
Access point T2455 terminals 192.9.175.9 192.9.175.10 192.9.175.11
2455U.089
You can install the T2455 terminals and access points in one IP subnetwork and install the DCS 300 in another IP subnetwork as shown in the illustration. In this network, you must configure additional network parameters (default router and subnet mask) as described later in this chapter. Note: If you are using the 21XX Universal Access Point™ (UAP), the T2455 terminal can roam between subnetworks. If you are using the 01XX access point, the T2455 cannot roam between subnetworks.
4-13
Page 132
TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual nugget CODE39
Planning the Network Connection To use the T2455 in the 2.4 GHz RF network, you need these minimum requirements: • •
DCS 300 (only T2455 with UDP Plus) Access point
When you first consider purchasing a wireless data collection system, an Intermec representative works with you to perform a site survey at your facility. The site survey analyzes the range of radio frequency devices in your facility and determines the placement of the access points. The site survey ensures that the coverage of each access point overlaps to provide uninterrupted wireless access at any location within the building. This manual assumes that a site survey is complete and the access points are installed in your facility. You need to work with your network administrator to plan and assign the IP address for each device in the 2.4 GHz RF. You must assign and set the IP address for each access point (RF) and each T2455 terminal. For a T2455 with UDP Plus, you must also assign an IP address to the DCS 300.
Configuring the DCS 300 The DCS 300 server supports and manages communications with other devices in the 2.4 GHz RF network. When you install and configure the DCS 300, you identify the host computer(s) and T2455 terminals in your network. The terminals communicate through the DCS 300 with your host by using UDP Plus protocol. For help installing the DCS 300, see the DCS 300 System Manual (Part No. 067296). Note: You can use a T2455 running TCP/IP protocol and the DCS 300 in a passthrough network. You establish a direct TCP/IP socket connection from the T2455 to the host through the DCS 300. For more information, see the DCS 300 System Manual. To have the T2455 communicate with the DCS 300, you must configure these parameters on the server: •
Configure the UDP Plus network.
•
Assign an IP address to each T2455.
•
Enable all T2455 terminals.
•
Define the host environment parameters, which includes configuring for terminal emulation, screen mapping, or client/server applications.
•
Define the host communications parameters, which includes the physical connection (network adapter cards) to the host.
To do screen mapping on the DCS 300, you must:
4-14
• create the script file using the Script Builder tool on the server.
• create an application using EZBuilder and download it to the T2455.
Page 133
nugget CODE39 Operating the Terminal in a Network
4
Configuring the Access Point The access point acts as a bridge to provide RF communications between the T2455 terminal and the DCS 300 or host. For help, see your access point user’s manual. Note: If you are using the 21XX Universal Access Point™ (UAP), the T2455 terminal can roam between subnetworks. If you are using the 01XX access point, the T2455 cannot roam between subnetworks. To have the T2455 communicate with the access point, you must know the value of these parameters on the access point: •
RF domain
•
RF security identification (ID) (optional)
Configuring the T2455 When you install the T2455 terminal in a network, you must configure a set of network parameters that control how the terminal communicates in the network. There are two ways to configure the network parameters: •
Use the TRAKKER Antares 2400 Menu System. For help on configuring the network parameters, see Chapter 2, “Installing the Terminal.”
•
Scan the configuration command from a Code 39 or Code 93 bar code label. The configuration commands are listed alphabetically by command name in Chapter 9, “Configuration Command Reference.”
The set of network parameters you must configure depends on whether you install the terminal on the same IP subnetwork as the DCS 300 or host (TCP/IP), or on a different subnetwork. The next table lists the parameters you configure in each type of network. Same IP Subnetwork?
Different IP Subnetwork?
Time and date
X
X
Network activate
X
X
Controller IP address (UDP Plus)
X
X
Host IP address (TCP/IP)
X
X
Terminal IP address
X
X
Network port
X
X
RF domain
X
X
Optional
Optional
Network Parameters
RF security ID Default router
X
Subnet mask
X
The network parameters are defined in the next section.
4-15
Page 134
TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual nugget CODE39
Defining the Network Parameters This section defines the network parameters you configure when installing the T2455 terminal in an RF network. For each parameter’s syntax and options, see Chapter 9, “Configuration Command Reference.” Time and Date When you turn on the terminal for the first time, you must set the current time and date. You also need to set the time and date any time you lose all power to the terminal. For help, see “Setting the Time and Date” in Chapter 2. Network Activate On a T2455, the Network Activate command disables or enables RF communications. If the Network Activate parameter is disabled, the network is disabled, no RF communications are provided, and the radio is turned off. When the Network Activate parameter is enabled, the T2455 will try to connect to the access point or DCS 300. Controller IP Address An IP address is a unique network level address you assign to each device in a TCP/IP network. The Controller IP Address identifies the IP address assigned to the DCS 300 or Model 200 Controller in a UDP Plus network. Host IP Address An IP address is a unique network level address you assign to each device in a TCP/IP direct connect network. The Host IP Address identifies the IP address assigned to the host in your 2.4 GHz RF network. Terminal IP Address An IP address is a unique network level address you assign to each device in a TCP/IP network. The Terminal IP Address identifies the IP address assigned to the T2455. The IP address you set on the terminal must match the address that is set for the terminal on the DCS 300. Network Port Defines the network port that the TCP/IP or UDP Plus network protocol uses for communications in your 2.4 GHz RF network. In a UDP Plus network, the network port you set on the T2455 must match the network port that is set on the DCS 300. In a TCP/IP network, set the network port to the appropriate port for the application you are using on the T2455. The default network port of 23 enables VT/ANSI Telnet communications. RF Domain The domain defines a logical partition or subnetwork of the network. To establish communications, you must assign the same domain number to every RF device in a wireless network. The domain number you set on the terminal must match the domain that is set on each access point the terminal may communicate with. You can continue to collect data with the terminal as you roam between access points as long as all the devices have the same domain number. RF Security Identification (ID) This optional parameter defines the password you can set for secured transmission and receipt of data between devices in the wireless network. To communicate, each access point and terminal must have matching security IDs. If the security ID is set on the access point, you must also set the security ID on each T2455 that may communicate with the access point. Note: The Network Activate command must be configured to 2.4 GHz RF network before you can save any changes to the RF security ID parameter.
4-16
Page 135
nugget CODE39 Operating the Terminal in a Network
4
Default Router Provides a software and hardware connection between two or more networks that permits traffic to be routed from one network to another on the basis of the intended destinations of that traffic. When the DCS 300 (UDP Plus) or host (TCP/IP) is on a different subnetwork than the T2455, you need to set the default router IP address. The terminal uses the router address to send packets across the network to the DCS 300 or host. The default router must have an IP address on the same subnetwork as the terminal. The default of 0.0.0.0 means there is no default router. Subnet Mask The subnet mask is an internal TCP/IP protocol stack variable that is used in IP protocol to identify the subnetwork for an IP address. The IP protocol performs a bit-wise AND on the IP address and the subnet mask. Each address segment represents one byte, where 255 converts to FF hex. This computation is used to find out if the DCS 300 (UDP Plus) or host (TCP/IP) and terminal are on different subnetworks. If the terminal is on a different IP subnetwork than the DCS 300 or host, then you must set the subnet mask and default router. For example, if the terminal IP address is 192.9.150.184 and the subnet mask is 255.255.255.0, the terminal is on the subnetwork 192.9.150.0.
Using the Status Lights to Monitor Network Communications Once you have configured the devices in the 2.4 GHz RF network, you can begin using the application on the T2455 to collect and transmit data via network communications. If the T2455 is communicating with your host computer, the terminal will connect and begin running the application that shipped on the terminal. You can begin using the terminal to collect data. As you use the T2455 to collect data, status lights help you monitor RF and network communications on the terminal. Use the Network Connect and Transmit status lights to monitor communications between the T2455 and other devices in the 2.4 GHz RF network.
Using the Status Lights to Monitor Network Communications You See These Lights
Status of Communications
What You Need to Do
Network Connect status light is turned off.
No communications. The T2455 is not connected to an access point.
You may need to enable the Network Activate command. Make sure the terminal is configured correctly to communicate in your network. For help, see “Configuring the T2455” earlier in this chapter. Make sure the access points are turned on and operating. You may also be using the terminal out of the RF range of an access point. Try moving closer to an access point to re-establish communications.
4-17
Page 136
TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual nugget CODE39
Using the Status Lights to Monitor Network Communications (continued) You See These Lights
Status of Communications
What You Need to Do
Partial communications.
You may need to configure the terminal to communicate with other devices in the 2.4 GHz RF network. For help, see “Configuring the T2455” earlier in this chapter.
The T2455 with UDP Plus is trying to establish communications with the DCS 300, but it is not connected.
The Network Connect status light blinks.
If the T2455 is configured, you may be out Note: The Network Connect status light does not blink on a T2455 with the TCP/IP of range of an access point, you may be about to go out of range of an access point, protocol. or the access point may have recently been turned off. You may also need to configure the DCS 300 (UDP Plus) or host. Make sure the terminal is configured correctly and enabled. Make sure the DCS 300 is turned on and data collection is started.
The Network Connect status light remains on.
The Network Transmit status light remains on and the Network Connect status light is turned on.
Normal communications. The T2455 can communicate with the DCS 300 (UDP Plus) or host (TCP/IP).
You can send and receive data between the terminal and the DCS 300 or host.
Normal communications. The T2455 is sending data or has received data for an application from the DCS 300 or host. The data is stored in the terminal network buffer until the application is ready to process the data.
You can send and receive data between the terminal and the DCS 300 or host.
Using the T2455 Between Access Points The access point acts as a bridge to provide communications between the T2455 terminal and the Ethernet or token ring network. You may have multiple access points in your 2.4 GHz RF network to provide uninterrupted wireless communication at any location within your facility. To use the terminal between access points and continue sending and receiving data, you must follow these guidelines:
4-18
•
The radio coverage of each access point must overlap to ensure that the roaming T2455 will always have a connection available.
•
You configure each access point with the same RF domain number and security ID.
•
You configure the T2455 terminal with the same RF domain and security ID as the access points to which they may communicate.
Page 137
nugget CODE39 Operating the Terminal in a Network
4
•
When you use the 01XX access point, the T2455 cannot roam between IP subnetworks. All of the 01XX access points that the T2455 may communicate with and roam between must be installed in the same IP subnetwork.
•
When you use the 21XX Universal Access Point™ (UAP), the T2455 can roam between IP subnetworks. The 21XX UAPs that the T2455 may communicate with and roam between can be installed on different IP subnetworks.
Once the network is configured, you can collect data anywhere within range of the access points in the wireless network. When you move out of range of one access point, the terminal automatically polls the other access points in the same RF domain to continue the network connection. If you are out of range of all access points in the network, the data is stored in the terminal’s radio buffer. The Network Transmit status light turns on. You can continue to collect data until the radio buffer is full. When the buffer is full, the application displays a communication timeout status. When you move back into range and network communications are re-established, the data in the radio buffer is transmitted to the access point and you can once again transmit data. In a TCP/IP direct connect network with a terminal running a terminal emulation application, the application may disconnect from the host if you remain out of communications range too long or if the host sends “Keep Alive” messages while the terminal is in Suspend mode. You may need to restart the application and log back into the host to re-establish a terminal emulation session. In a UDP Plus network, the session is maintained any time the terminal is out of range or in Suspend mode.
Configuring the T2455 Over the Network You can remotely configure a T2455 terminal by using one of these methods: •
Send a command from the DCS 300 (UDP Plus network only).
•
Send a command from an application on the host computer (UDP Plus and TCP/IP networks).
You cannot configure any of the RF network parameters, such as terminal IP address, over the network. Once the terminal is communicating, you can configure bar code symbologies and send operating commands. Note: You can configure the terminal locally by using the TRAKKER Antares 2400 Menu System or by scanning a command from a Code 39 or Code 93 bar code label. For help, see Chapter 3, “Configuring the Terminal.”
4-19
Page 138
TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual nugget CODE39
Configuring the T2455 From the DCS 300 You can use the DCS 300 to configure one or more T2455 terminals in your 2.4 GHz RF network. You can also send reader commands such as Delete File to one or more terminals. Your terminal must be configured with UDP Plus in order to communicate with the DCS 300. This method is very fast and efficient if you need to change the same configuration parameters for several terminals in one area. For example, you may want to set the Beep Volume to very loud and turn on Keypad Caps Lock for all terminals in one area. Note: You can configure a T2455 from the DCS 300, but you cannot get configuration data from the terminal. To send commands from the DCS 300 1. Using the Download Server feature on the DCS 300, select the terminal or group to which you want to download the configuration commands. For help on configuring a group of terminals, see the DCS 300 System Manual. Note: You can continue running an application on the T2455 while configuring the terminal from the DCS 300. 2. Choose the Command option button. 3. Enter the reader or configuration command and choose Add. The command appears in the Files and Data box. For example, enter this command to set the Beep Volume to very loud: $+BV4
For a list of reader commands, see Chapter 8, “Reader Command Reference.” For a list of configuration commands, see Chapter 9, “Configuration Command Reference.” Note: You can set the Postamble or Preamble command to use characters from the extended ASCII character set such as the Field Exit code for 5250 TE. For help, see “Auto-Advancing Through Fields on 5250 TE Screens” in the TRAKKER Antares Terminal Emulation User’s Guide. 4. Repeat Step 3 to add another reader or configuration command, or choose OK. 5. To save the configuration changes in flash memory on the T2455, enter this reader command as the last command and choose Add: .+1
Otherwise, the commands only change the runtime configuration. You can also use the TRAKKER Antares 2400 Menu System to save configuration changes in flash memory on the T2455. For help, see “Saving Configuration Changes in Flash Memory” in Chapter 3.
4-20
Page 139
nugget CODE39 Operating the Terminal in a Network
4
6. Choose Download to download the commands and change the configuration of the terminals selected.
Configuring the T2455 From the Host You can use an application on the host computer to configure one T2455. For example, you may want to change the Beep Volume command or the Keypad Caps Lock. To send and receive configuration data or files, you need to write an application for the host that can communicate with the DCS 300 in a UDP Plus network or directly through the access point in a TCP/IP direct connect network. You use the Terminal Message Format (TMF) protocol in the 2.4 GHz RF network to send and receive transactions between the host application and the terminal. UDP Plus is an Intermec value-added protocol. TCP/IP is an industry standard protocol. For help, see “About Network Connectivity and Protocols” later in this chapter.
Configuring the T2455 in a UDP Plus Network You can use the host computer to configure one T2455 terminal in your 2.4 GHz RF network. For example, you may want to change the Beep Volume command and the Keypad Caps Lock command. To send and receive configuration data, you need to write an application for the host that can communicate with the DCS 300. For help, see the DCS 300 Technical Reference Manual. You use the Terminal Message Format (TMF) protocol to send and receive transactions between the host application and the terminal. Note: You can continue running an application on the T2455 while configuring the terminal. To set up the DCS 300 •
Configure a peer-to-peer destination name for the host application. Create a transaction ID, $NGCFGRSP, that will be routed to this destination name. The DCS 300 uses the transaction ID to route responses from the T2455 back to the host application. $NGCFGRSP is a special transaction ID that the DCS 300 uses to forward configuration response data from a terminal. All configuration responses will be routed with the $NGCFGRSP transaction ID. The DCS 300 cannot keep track of multiple applications sending reader or configuration commands. If you have two host applications sending reader or configuration commands, they must both be configured to receive the $NGCFGRSP transactions, and therefore both will receive all responses from all T2455 terminals.
4-21
Page 140
TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual nugget CODE39
To set up the host computer •
Verify that you can communicate with the DCS 300.
To set up the application •
Prepare and write a host application that can communicate with the DCS 300 and send transactions to and receive transactions from the T2455 in this format: transaction header
TMF field configuration command where: transaction header is a 96-byte field containing the message number, date and time, source application ID, destinations application ID, transaction ID, and other information. You must set the system message (SYS$MSG) flag to E in the transaction header. For help, see the DCS 300 Technical Reference Manual.
TMF field is a 2-byte field containing one of these values:
configuration command
CG
Configuration Get request sent from the host application.
Cg
Configuration Get response sent from the T2455 to the host.
CS
Configuration Set request sent from the host application.
Cs
Configuration Set response sent from the T2455 to the host.
is the reader or configuration command or commands you want to set on the terminal, or the current value you want to retrieve from the terminal. To save configuration changes in flash memory, send the reader command .+1 as the last command. For a list of commands, see Chapter 8, “Reader Command Reference,” or Chapter 9, “Configuration Command Reference.”
To see examples of the host application transactions, see “Example 1” and “Example 2” later in this section.
Configuring the T2455 in a TCP/IP Direct Connect Network You can use the host computer to configure one T2455 terminal in your 2.4 GHz RF network. For example, you may want to change the Beep Volume command and the Keypad Caps Lock command.
4-22