Page 474
D Using the Default Applications
Page 475
D-2
Page 476
nugget Using the Default Applications
D
This appendix defines the APPTSK.BIN and EM9560.BIN applications that are shipped on the TRAKKER Antares 2455 terminal and explains how to use each application.
About the Applications Shipped on the Terminal The TRAKKER Antares 2455 terminal ships loaded with at least these two applications: •
APPTSK.BIN
•
EM9560.BIN
Both applications are stored on drive C. In addition to these two applications, your terminal may have a 3270, 5250, or VT/ANSI terminal emulation application stored on drive C. This section explains how to use the APPTSK.BIN and EM9560.BIN applications. For help with your terminal emulation applications, see the TRAKKER Antares Terminal Emulation User’s Guide.
Defining APPTSK.BIN and EM9560.BIN You can run and use APPTSK.BIN or EM9560.BIN at any time. The two applications are defined as follows: APPTSK.BIN This application is the default application on all terminals. In some error conditions or if you exit an application, the terminal resets and runs APPTSK.BIN. You can use APPTSK.BIN to scan, enter, transmit, and display data. EM9560.BIN This application emulates a subset of the functionality available on the Intermec 95XX terminals, such as the 9512 and 9560. You can use EM9560.BIN to scan, enter, transmit, and display data. APPTSK.BIN and EM9560.BIN include these features:
•
Works with any protocol that is supported on the terminal. Both the terminal and the device you are communicating with must use the same protocol (serial or RF) and parameter settings.
•
Displays the time and date, which can be toggled on and off.
•
Sends scanned or keyboard data out all serial or RF ports.
•
Buffers the keyboard data until you press Enter.
•
Receives data from any serial or RF port, displays the data on the terminal screen, and parses the data for commands.
•
Receives data through any serial port and transmits it out the RF port.
•
Receives data through the RF port and transmits it out all serial ports.
The main difference between the two applications is that you can use the EM9560.BIN application to emulate specific functions of the 95XXs.
D-3
Page 477
TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual nugget
Defining the Emulation Features of EM9560.BIN The T2455 is a programmable terminal that runs C/C++ applications. With the EM9560.BIN application, you can use the terminal as a remote input/output terminal in which all prompts and commands are controlled by the host computer. With this application, the terminal is similar to a 95XX in Data Entry mode with no application running. Note: For the 95XXs, Data Entry mode with no application running is also referred to as an unprogrammed state or 95XX dumb terminal mode. The EM9560.BIN application lets you use the terminal to emulate these specific 95XX features: •
An Enter key without any preceding data transmits an empty data packet.
•
The T2455 display is similar to but not identical to the 9560 buffered display mode.
•
All function keys transmit the corresponding characters F1, F2, and so on.
•
When Code 128 is configured for Standard Code 128 symbology and you scan a UCC/EAN label, the terminal will discard the Function 1 characters. Although this does not meet the industry standard for Code 128, it does emulate the 95XX, which was manufactured before the current standard was established. Other Code 128 configurations work as defined in this user’s manual.
•
The Set Time and Date reader (data entry) command is supported. When the terminal receives a time broadcast command (/+) from the 9154 or 9161 controller, the command sets the clock on the terminal. Note: With Version 5.X firmware or later, the Set Time and Date reader command is supported through the firmware and not just in the EM9560.BIN application.
D-4
•
The High Beep reader command is supported. When a backslash character (\) is sent to the terminal through any serial or network port, the terminal sounds a high beep.
•
The Low Beep reader command is supported. When the BEL character is sent to the terminal through any serial or network port, the terminal sounds a low beep.
•
When control codes (ANSI escape sequences) are sent to the terminal through any serial or network port, the terminal formats the display. For a list of control codes, see “Using Display Control Codes” later in this appendix.
•
Preamble A, Preamble B, and Postamble C are supported through the AA, AB, and AC configuration commands or through the reader commands +., ++, and +%. For help, see “Setting Preambles and Postambles” later in this appendix.
•
Full ASCII mode for Code 39 can be configured through the CB or RB configuration commands or through the reader commands +$ and -$. For help, see “Full ASCII Mode for Code 39” later in this appendix.
Page 478
nugget Using the Default Applications
•
D
The Exit Configuration Mode, Save Settings configuration command ($-) is not required, but bar code labels with this command scan correctly.
Using Display Control Codes You can use control codes to position the cursor or to format the terminal display. The EM9560.BIN application recognizes the display control codes listed next. Command
Control Code
Description or Action
Backspace
BS (08 Hex)
Moves the cursor one position to the left until the cursor reaches the first column. If the cursor is in the first column of any row except the first row, a Backspace command moves the cursor to the last column of the previous row.
Cursor Position
ESC[n;vH
Moves the cursor to the position specified by the n and v parameters where: n specifies the row or line number. v specifies the column number. If you enter zero or no parameter, n and v are set to one. If n or v exceeds the maximum row or column number on the display, the parameters are set to the screen’s maximum.
Erase Display
ESC[2J
Erases the entire display and returns the cursor to the home position (row 1, column 1). This command also erases the entire virtual display image (buffer with up to four rows of the most recently displayed data).
Home
CR (0D Hex)
Returns the cursor to the first column of the current row.
Next Line
LF (0A Hex)
Moves the cursor down one row in the current column position. If the cursor is already in the last row, a new line is added.
Restore Cursor Position
ESC[u
Restores the cursor position saved with a Save Cursor Position command. Each Restore Cursor Position command must be paired with a preceding Save Cursor Position command. If a Save Cursor Position command has not been previously entered, the cursor position will not change.
Save Cursor Position
ESC[s
Saves the current cursor position. Successive Save Cursor Position commands overwrite the previous position that was saved.
D-5
Page 479
TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual nugget
Setting Preambles and Postambles With the EM9560.BIN application, you can set Preamble A, Preamble B, and Postamble C on the T2455 and make the terminal compatible with the 95XXs. The preambles are prepended and the postamble is appended to the data that is transmitted through all the serial ports. Preamble A, Preamble B, and Postamble C can each be up to 25 ASCII characters in length. If you enter a preamble or postamble command without entering data, the preamble or postamble buffer is cleared. Syntax:
Scan:
Preamble A Preamble B Postamble C
AAdata or +.data ABdata or ++data ACdata or +%data
To set the preamble or postamble using the AA, AB, or AC configuration commands: 1. Scan one of these bar code labels: Enter Accumulate Mode / Set Preamble A
*+/$+AA* *+/$+AA*
Enter Accumulate Mode / Set Preamble B
*+/$+AB* *+/$+AB*
Enter Accumulate Mode / Set Postamble C
*+/$+AC* *+/$+AC*
2. Scan a value for data from the “Full ASCII Bar Code Chart” in Appendix B. The preamble or postamble can be from 1 to 25 characters. 3. Scan this bar code: Exit Accumulate Mode
*-/* *-/*
4. Repeat Steps 1 to 3 to set another preamble or postamble.
D-6
Page 480
nugget Using the Default Applications
Or:
D
To set the preamble or postamble using the +., ++, or +% reader commands: 1. Scan one of these bar code labels: Enter Accumulate Mode / Set Preamble A
*+/+.* *+/+.*
Enter Accumulate Mode / Set Preamble B
*+/++* *+/++*
Enter Accumulate Mode / Set Postamble C
*+/+%* *+/+%*
2. Scan a value for data from the “Full ASCII Bar Code Chart” in Appendix B. The preamble or postamble can be from 1 to 25 characters. 3. Scan this bar code: Exit Accumulate Mode
*-/* *-/*
4. Repeat Steps 1 to 3 to set another preamble or postamble.
Full ASCII Mode for Code 39 With the EM9560.BIN application, you can configure Full ASCII mode for Code 39 using any of these commands: •
Code 39 configuration command (CB)
•
Full ASCII configuration command (RB)
•
Enter Full ASCII Mode reader command (+$) and the Exit Full ASCII Mode reader command (-$)
The last two commands are compatible with the 95XXs. Each command is described next. For help with the Code 39 configuration command (CB), see Chapter 9, “Configuration Command Reference.” Note: Use the CB configuration command unless your terminals need to be compatible with the 95XXs in your data collection network.
D-7
Page 481
TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual nugget
Command:
Full ASCII configuration command (RB)
Purpose:
Configures the terminal to use Code 39 Full ASCII mode (enabled) or Code 39 NonFull ASCII mode (disabled). For a list of ASCII characters, see the “Full ASCII Table” in Appendix B.
Syntax:
RBdata Acceptable values for data are: 0 1
Scan:
Disabled Enabled
One of these bar code labels: Disable Full ASCII Mode
Enable Full ASCII Mode
*$+RB0*
*$+RB1*
*$+RB0*
Command:
*$+RB1*
Enter Full ASCII Mode reader command
Purpose:
Enables Code 39 Full ASCII mode so the terminal decodes Code 39 bar code labels by using a two-character encoding scheme to extend the character set to 128 characters. For a list of ASCII characters, see the “Full ASCII Table” in Appendix B.
Syntax:
+$
Scan:
Full ASCII
*+$* *+$*
Command:
Exit Full ASCII Mode reader command
Purpose:
Exits Code 39 Full ASCII mode and puts the terminal in Code 39 Non-Full ASCII mode (one-character encoding scheme).
Syntax:
-$
Scan:
Exit Full ASCII
*/M/D* *-$*
D-8
Page 482
nugget Using the Default Applications
D
Unsupported 95XX Features These 95XX features are not supported by the EM9560.BIN application on the T2455: •
Display Setting configuration command (OD) (buffered or transparent display).
•
Command Override reader (data entry) command (DLE).
•
Right Host Message reader command (HT).
•
Preamble A Required configuration command (OA).
•
Computer Response Required Mode (CRRM) configuration command (PB), Enter CRRM reader command (./), and Exit CRRM reader command (.-).
•
Resume IRL configuration command (XG).
•
Separate transmit and receive EOM characters (PI and PJ). The configurable EOM (PF, YZ) is used for both transmit and receive EOM.
•
Capacity reader command (%$).
•
Forward and Review reader commands (%+ and %/).
•
Download Program command from the 9154 or 9161 controller. Use the Transmit File reader command. For help, see Chapter 8, “Reader Command Reference.”
Note: Although these 95XX features are not supported, the T2455 does have many additional features (RF communications) that are not available on the 95XXs.
Running APPTSK.BIN and EM9560.BIN There are two ways to run APPTSK.BIN or EM9560.BIN: •
Use the Run Program reader command.
•
Use the TRAKKER Antares 2400 Menu System.
The instructions in this section explain how to use the Run Program reader command. For help using the TRAKKER Antares 2400 Menu System to run an application, see Chapter 5, “Using Custom Applications.”
D-9
Page 483
TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual nugget
Running APPTSK.BIN and EM9560.BIN (continued) To run APPTSK.BIN or EM9560.BIN on the terminal 1. Scan one of these bar code labels: Run APPTSK.BIN
*/O/OC/ZAPPTSK/NBIN* *//C:APPTSK.BIN* Run EM9560.BIN
*/O/OC/ZEM9560/NBIN* *//C:EM9560.BIN*
The terminal boots, resets all firmware, and runs the application. The initial screen for the application appears. You see one of these screens: APPTSK.BIN Screen 1998/01/00
EM9560.BIN Screen
12:00:00
2. Scan this bar code label to toggle the clock display on or off. Toggle Clock Display
*CLOCKDISPLAY* *CLOCKDISPLAY*
3. Use the application to scan bar code labels, enter data through the keyboard, and transmit data. The next section lists some examples of how you can use the applications.
D-10
Page 484
nugget Using the Default Applications
D
Example 1 Use the application to troubleshoot and test communications before loading and running your data collection application. Connect the terminal to your network. Type data (“Hello World”) on the TRAKKER Antares terminal keyboard or scan a bar code label. The data is sent out all serial and network ports and should be received by the host if your terminal is installed and configured correctly. Send data from the host and verify that the data displays on the terminal screen.
Example 2 Connect a serial input device, such as a 2D scanner, to a serial port on the TRAKKER Antares terminal. Data from the input device is displayed on the terminal screen and transmitted out the network (RF) port.
Example 3 Connect the TD2400 communications dock to a serial port on the T2485. Use a T2420 to collect data. Use the TD2400 communications dock to upload data from the T2420 to the T2485. Data is transmitted to the T2485 and out the RF port to the connected network devices.
Example 4 Use the T248X as a gateway between the CrossBar network and the Ethernet or RF network. Connect the T248X as a downline device in your CrossBar network. Connect the T2480/1 with the Ethernet option to your Ethernet network, or connect the T2485/6 to your RF network. While running the APPTSK.BIN or EM9560.BIN application, you can send data from the Ethernet or RF network through the T248X to the 9154 or 9161 and vice versa.
Example 5 Connect the COM1 serial port to the COM2 serial port on a T246X or T248X terminal. Use the terminal to configure itself by typing and entering configuration commands on the keypad or keyboard.
Example 6 Connect the serial port on the T248X to the serial port on the T246X terminal. Use the T248X to configure the T246X by typing and entering configuration commands on the T248X keypad.
D-11
Page 485
D-12