3. Scan this bar code: Exit Accumulate Mode
*-/* *-/*
Scanner Trigger Purpose:
Syntax:
Scanner trigger allows you to set level triggering or edge triggering. •
With level triggering, you activate the scanner and the laser turns on and stays on until you release the trigger on the laser scanner.
•
In edge triggering, you activate the scanner and the laser turns on and stays on. When you activate the scanner a second time, the laser turns off. Simply releasing the trigger does not turn the laser off. If the laser is left on, the scanner timeout turns the laser off.
SCdata Acceptable values for data are: 0 1
Default: Scan:
Level triggering Edge triggering
Level triggering One of these bar codes: Enable Level Triggering
*$+SC0* *$+SC0* Enable Edge Triggering
*$+SC1* *$+SC1*
9-91
Page 421
TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual
Serial Port Protocol Purpose:
Allows you to set the protocol that the serial port uses to communicate with the connected device. Communications protocols determine exactly how data is transmitted between the terminal and the RS-232 device. Each protocol has parameters you can set, such as baud rate and parity. Both the terminal and the RS-232 device must use the same protocol and parameter settings to communicate properly. For help on protocols, see the Data Communications Reference Manual (Part No. 044737). The terminal can communicate in these four protocols: •
Binary
•
Configurable protocol
•
Master Polling
•
Polling Mode D
Each protocol is described in Chapter 4, “Operating the Terminal in a Network.” Syntax:
YUn.data where n is: 1 4
COM1 port COM4 port
Acceptable values for data are: 0 2 8 12 Default: Scan:
Configurable Polling Mode D Master Polling Mode D Binary
Configurable To set the default serial port protocol, scan one of these bar codes: Configurable Serial Port Protocol for COM1
*$+YU1.0* *$+YU1.0* Configurable Serial Port Protocol for COM4
*$+YU4.0* *$+YU4.0*
9-92
Page 422
Configuration Command Reference
Or:
9
To set the serial port protocol for one serial port: 1. Scan this bar code: Enter Accumulate Mode / Set Serial Port Protocol
*+/$+YU* *+/$+YU*
2. Scan one of these bar codes to set the COM port: COM1
COM4
*1.*
*4.*
*1.*
*4.*
3. Scan the protocol setting: Configurable
Polling Mode D
*0*
*2*
*0*
*2*
Master Polling
Binary
*8*
*12*
*8*
*12*
4. Scan this bar code: Exit Accumulate Mode
*-/* *-/*
5. Repeat Steps 1 through 4 to set the serial port protocol for another serial port.
9-93
Page 423
TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual
Start of Message (SOM) Purpose:
SOM is the first character in a message sent to or received from the host computer through the terminal’s serial port. SOM cannot equal the same value that is set for EOM. You cannot set SOM to any of these values: • • • • •
AFF (ACK) DLE NEG (NAK) Poll RES (EOT)
• • • •
REQ (ENQ) SEL XOFF XON
Note: Before you can enable SOM, you must configure the EOM command. Syntax:
YYn.data where n is: 1 4
COM1 port COM4 port
An acceptable value for data is any ASCII character. Default: Scan:
\x02 (hexadecimal value for STX) To disable SOM, scan one of these bar codes: Disable SOM for COM1
*$+YY1.* *$+YY1.* Disable SOM for COM4
*$+YY4.* *$+YY4.*
Or:
To set SOM to an ASCII character for one serial port: Note: To scan these bar codes, you must configure the T2455 to use Code 39 in Full ASCII mode. For help, see “Code 39” earlier in this chapter. 1. Scan this bar code: Enter Accumulate Mode / Set SOM
*/K/O/D/KYY* *+/$+YY*
9-94
Page 424
Configuration Command Reference
9
2. Scan one of these bar codes to set the COM port: COM1
COM4
*1/N*
*4/N*
*1.*
*4.*
3. Scan a bar code for data from the “Full ASCII Bar Code Chart” in Appendix B. 4. Scan this bar code: Exit Accumulate Mode
*/M/O* *-/*
5. Repeat Steps 1 through 4 to set the SOM for another serial port. Notes:
For COM1 only, you can use either command syntax listed next: Syntax:
YY1.data or:
PEdata where data is any ASCII character. For COM4, you must use the YY command.
Stop Bits Purpose:
Sets the number of stop bits on the serial port.
Syntax:
YCn.data where n is: 1 4
COM1 port COM4 port
Acceptable values for data are: 1 2 Default: Scan:
1 stop bit 2 stop bits
1 One of these bar codes: 1 Stop Bit for COM1
*$+YC1.1* *$+YC1:1*
9-95
Page 425
TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual
Stop Bits (continued) 2 Stop Bits for COM1
*$+YC1.2* *$+YC1.2* 1 Stop Bit for COM4
*$+YC4.1* *$+YC4.1* 2 Stop Bits for COM4
*$+YC4.2* *$+YC4.2*
Notes:
For COM1 only, you can use either command syntax listed next: Syntax: or:
YC1.data ICdata where data is a value of 1 or 2. For COM4, you must use the YC configuration command.
Subnet Mask Purpose:
Defines the subnet mask, an internal TCP/IP protocol stack variable that is used to separate the subnetwork address from the local IP address. The TCP/IP protocol stack performs a bit-wise AND on the IP address and the subnet mask. Each address segment represents one byte, where 255 converts to FF hex. This computation is used to find out if the DCS 300 (UDP Plus) or host (TCP/IP) and terminal are on different subnetworks. If the terminal is on a different IP subnetwork than the DCS 300 or host, you must set the subnet mask. The default subnet mask 255.255.255.0 means the T2455 uses a standard IP network mask. For example, if the IP address is 192.009.150.184 and the subnet mask is 255.255.255.0, the subnetwork address is 192.009.150.0.
Syntax:
NSn.n.n.n where each n address segment is a number from 0 to 255. The subnet mask field consists of four separate numbers, each separated by a period.
Default: Scan:
9-96
255.255.255.0 To set the default subnet mask address, scan this bar code:
Page 426
Configuration Command Reference
9
Default Subnet Mask
*$+NS255.255.255.0* *$+NS255.255.255.0*
Or:
To set the subnet mask: 1. Scan this bar code: Enter Accumulate Mode / Set Subnet Mask
*+/$+NS* *+/$+NS*
2. Scan a numeric value from 0 to 255 to set an n field of the subnet mask address from these bar codes.
*0*
*1*
*0*
*1*
*2*
*3*
*2*
*3*
*4*
*5*
*4*
*5*
*6*
*7*
*6*
*7*
*8*
*9*
*8*
*9*
3. Scan this bar code: . (Period)
*.* *.*
4. Repeat Steps 2 and 3 to set the next three numbers in the subnet mask address field. After you scan the last address segment, go to Step 5. Do not scan the period after the last address segment. 5. Scan this bar code: Exit Accumulate Mode
*-/* *-/*
9-97
Page 427
TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual
Suspend/Resume Control f
Purpose:
Controls the operation of the key (suspend/resume). You can enable or disable the key. When the key is disabled, you cannot turn off the terminal. By default, the key is enabled so you can turn the terminal on and off.
Syntax:
EFdata f f f
Acceptable values for data are: 0 1 Default: Scan:
Enabled Disabled
Enabled One of these bar codes: Enable f Key
*$+EF0* *$+EF0* Disable f Key
*$+EF1* *$+EF1*
TCP Maximum Retries Purpose:
Defines the maximum number of times TCP will attempt to transmit data before giving up and terminating the TCP connection.
Syntax:
NJdata Acceptable values for data are any number from 5 to 50.
Default: Scan:
12 To set the default TCP maximum retries, scan this bar code: Default TCP Maximum Retries
*$+NJ12* *$+NJ12*
9-98
Page 428
Configuration Command Reference
Or:
9
To set the TCP maximum retries: 1. Scan this bar code: Enter Accumulate Mode / Set TCP Maximum Retries
*+/$+NJ* *+/$+NJ*
2. Scan a numeric value for data from these bar codes:
*0*
*1*
*0*
*1*
*2*
*3*
*2*
*3*
*4*
*5*
*4*
*5*
*6*
*7*
*6*
*7*
*8*
*9*
*8*
*9*
3. Scan this bar code: Exit Accumulate Mode
*-/* *-/*
TCP/IP Maximum Transmit Timeout Purpose:
Defines the maximum timeout that TCP will allow between retries of a transmission in a TCP/IP direct connect network before it gives up. For example, 20 means that the timeout between retries is never longer than 20 seconds. Intermec has determined that the optimum setting is 20 seconds.
Syntax:
NHdata Acceptable values for data are: 0 1-128
No timeout Transmit timeout in seconds
9-99
Page 429
TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual
TCP/IP Maximum Transmit Timeout (continued) Default: Scan:
20 seconds To set the default TCP/IP maximum transmit timeout, scan this bar code: Default TCP/IP Maximum Transmit Timeout
*$+NH20* *$+NH20*
Or:
To set the TCP/IP maximum transmit timeout: 1. Scan this bar code: Enter Accumulate Mode / Set TCP/IP Maximum Transmit Timeout
*+/$+NH* *+/$+NH*
2. Scan a numeric value for data from these bar codes:
*0*
*1*
*0*
*1*
*2*
*3*
*2*
*3*
*4*
*5*
*4*
*5*
*6*
*7*
*6*
*7*
*8*
*9*
*8*
*9*
3. Scan this bar code: Exit Accumulate Mode
*-/* *-/*