Trakker Antares 24XX Terminal User's Manual Addendum: Chapter 9 - Configuration Command Reference, pages 340 to 349

Pages 340 to 349 of 501, from Trakker Antares 24XX Terminal User's Manual Addendum

The original document is the PDF (2.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Intermec 2455

Page 340

Configuration Command Reference

*6*

*7*

*6*

*7*

*8*

*9*

*8*

*9*

9

3. Scan this bar code: Exit Accumulate Mode

*-/* *-/*

Baud Rate Purpose:

Sets the baud rate for the serial port on the terminal. The baud rate must match the baud rate of the device (i.e., the host computer) that the terminal is communicating with through the serial port.

Syntax:

YAn.data where n is: 1 4

COM1 serial port COM4 serial port

Acceptable values for data are: 3 4 5 6 7 8 Default: Scan:

1200 baud 2400 baud 4800 baud 9600 baud 19200 baud 38400 baud

19200 To set the default baud rate for each serial port, scan these bar codes: Default Baud Rate for COM1

*$+YA1.7* *$+YA1.7* Default Baud Rate for COM4

*$+YA4.7* *$+YA4.7*

9-11

Page 341

TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual

Baud Rate (continued) Or:

To set the baud rate for one serial port: 1. Scan this bar code: Enter Accumulate Mode / Set Baud Rate

*+/$+YA* *+/$+YA*

2. Scan the serial port from these bar codes: COM1

COM4

*1.*

*4.*

*1.*

*4.*

3. Scan the baud rate from these bar codes: 1200 Baud

2400 Baud

*3*

*4*

*3*

*4*

4800 Baud

9600 Baud

*5*

*6*

*5*

*6*

19200 Baud

38400 Baud

*7*

*8*

*7*

*8*

4. Scan this bar code: Exit Accumulate Mode

*-/* *-/*

5. Repeat Steps 1 through 4 to set the baud rate for another serial port. Notes:

For COM1 only, you can use either command syntax listed next: Syntax: or:

YA1.data IAdata where data is a value from 3 to 8 for the baud rate. For COM4, you must use the YA configuration command.

9-12

Page 342

Configuration Command Reference

9

Beep Volume Purpose:

Adjusts the volume of the terminal’s audio signals. For a list of all the beep sounds and audio signals, see “Understanding the Terminal Audio Signals” in Chapter 1. Set the beep volume and keyclick according to operator preference and work environment. Note: If the Beep Volume is turned off, you will not hear any audio signals including the keyclick.

Syntax:

BVdata Acceptable values for data are: 0 1 2 3 4 8 9

Default: Scan:

Off Quiet Normal Loud Very loud Lower volume Raise volume

Very loud One of these bar codes: Beep Volume Off

Beep Volume Quiet

*$+BV0*

*$+BV1*

*$+BV0*

*$+BV1*

Beep Volume Normal

Beep Volume Loud

*$+BV2*

*$+BV3*

*$+BV2*

*$+BV3*

Beep Volume Very Loud

*$+BV4* *$+BV4*

Or:

Scan one of these bar codes repeatedly to achieve the desired volume: Raise Beep Volume

Lower Beep Volume

*$+BV9*

*$+BV8*

*$+BV9*

*$+BV8*

9-13

Page 343

TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual

Codabar Purpose:

Enables or disables decoding of Codabar symbology. Codabar is a self-checking, discrete symbology. The American Blood Commission (ABC) Codabar requires that you retain and transmit the start/stop code digits when processing a Codabar symbol. As a result, configuration CD10 is an illegal configuration.

Syntax:

CDdata Acceptable values for data must be two digits, corresponding to:

Default: Scan:

Digit

Value

Description

First

0 1 2 3

Disabled ABC Standard Concatenated

Second

0 1 2

Discard Start/Stop Transmit ABCD Start/Stop Transmit DC1-DC4 Start/Stop

Disabled One of these bar codes: Disabled, Discard Start/Stop

ABC, Transmit ABCD Start/Stop

*$+CD00*

*$+CD11*

*$+CD00*

*$+CD11*

ABC, Transmit DC1-DC4 Start/Stop

Standard, Discard Start/Stop

*$+CD12*

*$+CD20*

*$+CD12*

*$+CD20*

Standard, Transmit ABCD Start/Stop

Standard, Transmit DC1-DC4 Start/Stop

*$+CD21*

*$+CD22*

*$+CD21*

*$+CD22*

Concatenated, Discard Start/Stop

Concatenated, Transmit ABCD Start/Stop

*$+CD30*

*$+CD31*

*$+CD30*

*$+CD31*

Concatenated, Transmit DC1-DC4 Start/Stop

*$+CD32* *$+CD32*

9-14

Page 344

Configuration Command Reference

9

Code 11 Purpose:

Enables or disables decoding of Code 11 symbology. Code 11 is a very high density, discrete numeric bar code. It is most extensively used in labeling telecommunications components and equipment.

Syntax:

CGdata Acceptable values for data are: 0 1 2

Default: Scan:

Disabled Code 11 enabled with one check digit Code 11 enabled with two check digits

Disabled One of these bar codes: Disable Code 11

*$+CG0* *$+CG0* Code 11 Enabled With One Check Digit

*$+CG1* *$+CG1* Code 11 Enabled With Two Check Digits

*$+CG2* *$+CG2*

9-15

Page 345

TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual

Code 16K Purpose:

Enables or disables decoding of Code 16K symbology. Code 16K is a two-dimensional (stacked rows), high density bar code. It is based on Code 128 and is used widely to label unit-dose packaging for the healthcare industry.

Syntax:

CPdata Acceptable values for data are: 0 1 2

Disabled Standard Code 16K enabled Code 16K enabled with Function Code 1

When you enable Code 16K with Function Code 1, the terminal decodes the bar code label and checks for a Function Code 1 in the first data character position. If a Function Code 1 is the first character, the terminal substitutes this Code 16K symbology identifier string for the Function Code 1 character. ]K1

Default: Scan:

Disabled One of these bar codes: Disable Code 16K

*$+CP0* *$+CP0* Standard Code 16K Enabled

*$+CP1* *$+CP1* Code 16K Enabled With Function Code 1

*$+CP2* *$+CP2*

9-16

Page 346

Configuration Command Reference

9

Code 2 of 5 Purpose:

Enables or disables decoding of Code 2 of 5 symbology. Code 2 of 5 uses the bars to encode information and the spaces to separate the individual bars. This code is discrete and self-checking. You can only enable Code 2 of 5 if the Interleaved 2 of 5 (I 2 of 5) code is disabled. If you enable I 2 of 5, Code 2 of 5 is automatically disabled.

Syntax:

CCdata where data consists of three digits as follows:

Default: Scan:

First digit:

0 1

Code 2 of 5, 3 Bar Start/Stop Code 2 of 5, 2 Bar Start/Stop

Second and third digits:

00 01-32

Disable Code 2 of 5 Label Length

Disabled To disable Code 2 of 5, scan this bar code: Disable Code 2 of 5

*$+CC000* *$+CC000*

Or:

To enable Code 2 of 5: 1. Scan one of these bar codes: Code 2 of 5, 3 Bar Start/Stop

*+/$+CC0* *+/$+CC0* Code 2 of 5, 2 Bar Start/Stop

*+/$+CC1* *+/$+CC1*

2. Scan a two-digit numeric value to set the label length (01-32) from these bar codes.

*0*

*1*

*0*

*1*

*2*

*3*

*2*

*3*

9-17

Page 347

TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual

Code 2 of 5 (continued)

*4*

*5*

*4*

*5*

*6*

*7*

*6*

*7*

*8*

*9*

*8*

*9*

3. Scan this bar code: Exit Accumulate Mode

*-/* *-/*

Code 39 Purpose:

Enables or disables decoding of Code 39 symbology. Code 39 is discrete, variable length, and self-checking. The character set is uppercase A to Z, 0 to 9, dollar sign ($), period (.), slash (/), percent (%), space ( ), plus (+), and minus (-). There are three types of ASCII the terminal decodes: •

Code 39 non-full ASCII

•

Code 39 full ASCII

•

Code 39 mixed-full ASCII

Code 39 non-full ASCII Non-full ASCII uses a one-character encoding scheme. For example, you encode the data “SAMPLE” as follows:

*SAMPLE* *SAMPLE*

This label decodes as SAMPLE. Code 39 full ASCII Full ASCII uses a two-character encoding scheme to extend the character set to 128 characters. You use the dollar sign ($), slash (/), percent (%), or plus (+) followed by an uppercase letter to represent one of the characters in the extended set. You must encode lowercase letters as a plus sign (+) followed by their uppercase equivalents. For a list of ASCII characters and their Code 39 representations, see the “Full ASCII Table” in Appendix B.

9-18

Page 348

Configuration Command Reference

9

Use Code 39 full ASCII to enter ASCII control characters or lowercase characters as data. You should also enable Code 39 full ASCII to use ASCII command characters. For example, you encode the data “sample” in Code 39 full ASCII as follows:

*+S+A+M+P+L+E* *+S+A+M+P+L+E*

In Code 39 non-full ASCII, this label decodes as +S+A+M+P+L+E. In Code 39 full ASCII, this label decodes as sample. Code 39 mixed-full ASCII Use mixed-full ASCII when printers encode the same label two different ways. For example, if you have a bar code with the data $%a, some printers encode the data as follows:

*/D/E+A* */D/E+A*

In the Full ASCII Table in Appendix B, /D represents $ and /E represents %. If you configure the terminal for Code 39 full ASCII, the terminal decodes the data as $%a because there are three valid full ASCII character pairs to represent the data. Other printers encode the data $%a as:

*$%+A* *$%+A*

The $ and % are valid Code 39 characters in the non-full ASCII character set. However, the terminal will not decode this label if it is configured for full ASCII, because the data is not represented by valid full ASCII character pairs. To decode the label correctly, you need to configure the terminal for mixed-full ASCII. When you configure the terminal for Code 39 mixed-full ASCII, the terminal will decode both of the labels above as $%a. Mixed-full ASCII interprets any valid full ASCII character pairs that appear in the label, but does not require that all data be encoded with a valid full ASCII character pair. If you are uncertain how your labels are encoded, configure the terminal for mixed-full ASCII, which decodes all valid Code 39 labels. If you configure the terminal for Code 39 full ASCII, you should check for Code 39 mixed-full ASCII. Mixed-full ASCII does not apply when you configure the terminal for non-full ASCII. Note: The interpretive text shown under bar code labels does not always accurately reflect the data that is encoded in the label. The interpretive text represents how the label should be decoded.

9-19

Page 349

TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual

Code 39 (continued) Use this table to help configure your terminal.

Syntax:

Code 39 Option

Bar Code Label

Decodes

Non-full ASCII

$%+A /D/E+A

$%+A /D/E+A

Full ASCII

$%+A /D/E+A

No decode $%a

Mixed-full ASCII

$%+A /D/E+A

$%a $%a

CBdata Acceptable values for data must be three digits, corresponding to: First digit:

0 1 2 3 4

Disabled Enabled with no check digit Enabled with check digit HIBC (Health Industry Bar Code) With AIAG check digit

Second digit:

0 1

Discard check digit Transmit check digit

Third digit:

0 1 2

Code 39 non-full ASCII Code 39 full ASCII Code 39 mixed-full ASCII

Note: Selecting HIBC Code 39 automatically sets the configuration to non-full ASCII with the check digit transmitted. Default: Scan:

Enable Code 39 Full ASCII with no check digit (111) To disable Code 39: Disable Code 39

*$+CB0* *$+CB0*

Or:

To enable Code 39: 1. Scan this bar code: Enter Accumulate Mode / Enable Code 39

*+/$+CB* *+/$+CB*

9-20