The text of a manual · part 39 of 59
Trakker Antares 24XX Terminal User's Manual Addendum: Chapter 8 - Reader Command Reference, pages 306 to 313
Pages 306 to 313 of 501, from Trakker Antares 24XX Terminal User's Manual Addendum
The original document is the PDF (2.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 2455
Page 306
8 Reader Command Reference
Page 307
Page 308
Reader Command Reference
8
This chapter describes the reader commands that you can use while operating the terminal. Reader commands, such as Change Configuration, allow you to perform a task on the terminal.
Using Reader Commands A reader command causes the terminal to perform a task. Some reader commands temporarily override the configuration settings and some actually change the configuration settings. For example, you can reset the terminal to the default configuration or change the configuration. You can execute reader commands by • scanning a command from a Code 39 or Code 93 bar code label.
• pressing keys on the keyboard or choosing a command from the TRAKKER Antares 2400 Menu System.
• sending a command from a device on the serial or RF network.
There are three general types of reader commands: •
Accumulate mode commands
•
Operating commands
•
File management commands
The reader commands are listed in alphabetical order within these three categories. You will find the purpose, command syntax, and bar code labels for each reader command in this chapter. Note: The Code 39 bar code labels in this chapter show an asterisk (*) at the beginning and end of the human-readable interpretation to represent the start and stop codes. If you are creating your own Code 39 bar code labels, your bar code printing utility may automatically supply the asterisks as the start/stop code.
Using Accumulate Mode You can use Accumulate mode to collect data from a series of bar code labels and enter them as a single label. When you put the terminal in Accumulate mode, the terminal will collect all scanned bar code labels in the terminal’s buffer until you scan either the Enter or Exit Accumulate mode command. As you accumulate the data from bar code labels, the data is visible on the bottom line of the screen. You can edit the accumulated data with the Backspace, Clear, and Enter commands.
8-3
Page 309
TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual
Backspace This command deletes the last character from the current data record you are accumulating. Clear
This command deletes the entire data record you are accumulating.
Enter This command will enter data as a record and leaves the terminal in Accumulate mode. Note: If you are not in Accumulate mode, the Backspace, Clear, and Enter commands have no effect and you will hear an error beep. When you exit Accumulate mode, the accumulated data is “entered” as a data record. Up to 250 characters can be held in the buffer. If the data record count exceeds 250 characters, the data is truncated. If you reset the terminal (software or hardware reset), you exit Accumulate mode, the entire buffer is cleared, and all data accumulated is lost. To use Accumulate mode The syntax to use the Enter Accumulate command is: +/data where: +/ is the syntax for the Enter Accumulate mode command.
data is the optional data you want to enter. Data can be a reader command that is executed when you exit Accumulate mode.
1. Scan this bar code label to Enter Accumulate mode: Enter Accumulate Mode
*+/* *+/*
2. Scan the bar code label(s) for the data you want to enter. You can scan labels from the “Full ASCII Bar Code Chart” in Appendix B. For example, scan this label to change the terminal’s configuration and set the preamble to the characters ABC. Change Configuration / Set Preamble to ABC
*$+ADABC* *$+ADABC*
8-4
Page 310
Reader Command Reference
8
Or, to edit the accumulated data, scan one of these bar code labels: Backspace
Clear
Enter
*-+*
*--*
**
*-+*
*- -*
**
Note: You can create one bar code label by combining Steps 1 and 2 above. Most of the examples in this manual use one bar code label. 3. Scan this bar code label to exit Accumulate mode and enter the data record. Exit Accumulate Mode
*-/* *-/*
Enter Accumulate Mode Purpose:
Enters Accumulate mode. You can accumulate data from a series of bar code labels and enter them as a single label.
From Network:
Not supported
Keyboard:
Not supported
Scan:
Enter Accumulate Mode
*+/* *+/*
Backspace Purpose:
Deletes the last character from the current data record being accumulated. If there is no data in the buffer, the command has no effect.
From Network:
Not supported
Keyboard:
Not supported
Scan:
Backspace
*-+* *-+*
8-5
Page 311
TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual
Clear Purpose:
Deletes the entire data record you are accumulating. If there is no data in the buffer, the command has no effect.
From Network:
Not supported
Keyboard:
Not supported
Scan:
Clear
*--* *- -*
Enter Purpose:
Enters the current data record and remains in Accumulate mode. If no data exists, a null string is entered.
From Network:
Not supported
Keyboard:
Not supported
Scan:
Enter
** **
Exit Accumulate Mode Purpose:
Exits Accumulate mode and transmits the current data record. If no data has been accumulated, an empty data record is entered.
From Network:
Not supported
Keyboard:
Not supported
Scan:
Exit Accumulate Mode
*-/* *-/*
8-6
Page 312
Reader Command Reference
8
Operating Reader Commands The reader commands you can use to operate or change the terminal’s configuration are listed in this section. The operating commands are listed in alphabetical order. You will find the purpose, syntax for commands sent from a network device, and bar code labels for these reader commands in this section. •
Boot Terminal
•
Change Configuration
•
Default Configuration
•
Multiple-Read Labels
•
Reset Firmware
•
Save Configuration in Flash Memory
•
Set Time and Date
•
Status Lights Control
•
Test and Service Mode
Boot Terminal Purpose:
Boots the terminal. The terminal runs through power-on self test (POST) to test each major subsystem. The terminal uses the configuration currently saved in flash memory to boot and then your application appears on the screen. Use this command when you upgrade the firmware on the terminal or if your terminal locks up and will not respond.
From Network: Scan:
-.1 Boot Terminal
*-.1* *-.1*
8-7
Page 313
TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual
Change Configuration Purpose:
From Network:
This command must precede any configuration command. If you enter a valid string, the terminal configuration is modified and the terminal sounds a high beep. For help on the configuration commands, see Chapter 9, “Configuration Command Reference.” $+command[command]...[command n] where command is a configuration command with the value you want to set.
Keyboard:
Press to access the TRAKKER Antares 2400 Menu System. From the Main Menu, choose the Configuration Menu to change the terminal configuration.
Example:
Change Configuration / Turn Off Beep Volume
*$+BV0* *$+BV0*
The Change Configuration command is followed by the configuration command to turn off the beep volume (BV0).
Default Configuration Purpose:
Sets the terminal to its default configuration, resets the firmware, boots the terminal, and runs your application. The default configuration for the terminal is listed in Appendix A. For help, see “Restoring the Terminal’s Default Configuration” in Chapter 3. When you use the Default Configuration command, the default configuration is saved in RAM and flash memory. The runtime and boot configuration are changed to the default configuration. Note: In the default configuration, the Primary Network parameters are set to the default values. The T2455 will no longer have a valid IP address and cannot communicate with other devices. You need to configure the T2455 again. For help, see Chapter 4, “Operating the Terminal in a Network.”
From Network: Keyboard:
Scan:
.+0 In the TRAKKER Antares 2400 Menu System, choose System Menu and then choose Load Default Values. Default Configuration
*.+0* *.+0*