Page 290

Nugg

Running Diagnostics Co de 39

7

Serial Loopback Purpose:

Where Available: Sample Screen:

Use the Serial Loopback test to verify that the hardware for the RS-232 serial port is functioning correctly. To run this diagnostic test, you must connect the terminal to a host computer or other serial device. Choose the Main Board Menu from the Hardware Diagnostics menu. SERIAL

PORT

LOOPBACK

WAITING /CTS 0 COM Port :1 Baud Rate :38400 Parity :None Data Bits :8 Echo RX Data on TX Echo /CTS on /RTS

[Esc]

Exit

2455U.119

Definition:

The serial port test begins immediately. If the serial port hardware is functioning correctly, the terminal displays WAITING and then RECEIVING. The Serial Loopback test uses the serial communications settings that are listed on the bottom half of the screen. On the host, you can use a serial communications package to send data to the terminal. If the terminal is communicating with the host, the data is echoed back. If there is a problem, an error message appears on the terminal screen. The status information on the screen is updated every 500 ms. For help with serial port errors, contact your local Intermec service representative.

7-19

Page 291

TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual Nugg Co de 39

Defining the System Diagnostics Screens Each system diagnostic screen is defined in this section.

Access Point Purpose:

Where Available:

Use the Access Point screen to get version and address information about the access point the terminal is communicating with across the 2.4 GHz RF network. System Diagnostics menu

Sample Screen:

ACCESS Radio ROM V1.6EB

POINT

Ver:

Radio MAC Addr: 0020A6306510 Access Point SHIPPING

Name:

Access Point 0020A6301365

MAC:

[Esc]

Exit

2455U.120

Definition:

7-20

The screen displays the radio ROM firmware version, radio MAC (machine) address, the access point name, and the access point MAC. If you have a problem with the radio or the connection to the access point, use the information on this screen to troubleshoot your network configuration.

Page 292

Nugg

Running Diagnostics Co de 39

7

Application Efficiency Purpose:

Where Available: Sample Screen:

Use the Application Efficiency screen to find out if your application is making the best use of and maximizing battery life on the terminal. System Diagnostics menu APP EFFICIENCY Subsystem Versions Application is running at 90% 80%

100% POOR

GOOD

Battery life affected by application efficiency. [Esc] is

Exit 2455U.121

Definition:

The screen displays the application efficiency percentage. The closer the percentage is to 100%, the more efficient the application is at using battery power. The terminal automatically goes into an internal Standby mode to draw power at a lower level when less power is required. An efficient application uses the TRAKKER Antares PSK (Programmer’s Software Kit) functions to wait for events to occur and it does not poll in an infinite loop. When programmed correctly with the PSK or EZBuilder, the application does not prevent the terminal from going into Standby mode and uses the terminal’s battery power as efficiently as possible.

7-21

Page 293

TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual Nugg Co de 39

Malloc Application Information Purpose:

Where Available: Sample Screen:

A programmer or application developer can use the Malloc Application Information screen to see how memory is allocated and used by the current application. Choose the Malloc Info Menu from the System Diagnostics menu. APPLICATION Total Free: 0000064656 Largest Free: 0000064656 Fragments: 00001 Allocated Blocks: 00001

OK 2455U.122

Definition:

The screen displays the memory allocation used by the application. You can view the total free memory, largest block of free memory, number of memory fragments, and total number of allocated blocks of memory. Use this diagnostic screen to troubleshoot a memory leak where the application is mallocing memory, but not freeing memory.

Malloc Firmware Information Purpose:

Where Available: Sample Screen:

A programmer or application developer can use the Malloc Firmware Information screen to see how memory is allocated and used in the terminal firmware. The firmware includes the operating environment, firmware, drivers, and TRAKKER Antares 2400 Menu System. Choose the Malloc Info Menu from the System Diagnostics menu. FIRMWARE Total Free: 0000007040 Largest Free: 0000006768 Fragments: 00002 Allocated Blocks: 00015

OK 2455U.123

7-22

Page 294

Nugg

Definition:

Running Diagnostics Co de 39

7

The screen displays the memory allocation for the terminal firmware. You can view the total free memory, the largest block of free memory, number of memory fragments, and the total number of allocated blocks of memory.

Serial Port Test Purpose:

Where Available:

Use the Serial Port Test screen to test or troubleshoot serial communications between the terminal and the host computer or serial device. To run this diagnostic test, you must connect the terminal to a host or other serial device. System Diagnostics menu

Sample Screen:

SERIAL

PORT

Select Com. 1,4, Esc :

TEST

Port: 1

F1:Port Select :1 F2:Keypad Echo : ON F3:Scanner Echo: ON F4:Continous TX: OFF F5:Exit -

2455U.124

Definition:

Press to test the RS-232 serial communications port. The screen displays the function key options you can use in this diagnostic screen. You may see the message “Port Not Available” if your application is currently using the serial port. You need to run an application that does not use the serial port for this diagnostic test. F1

Selects the serial port.

F2 Toggles the keypad echo on and off. If you turn the keypad echo on, characters you type on the keypad or keyboard are displayed on the bottom line of the screen and transmitted to the host. F3 Toggles the scanner echo on and off. If you turn the scanner echo on, the bar code label you scan is displayed on the bottom line of the screen and transmitted to the host. F4 Toggles the Continuous Transmit mode on and off. If you turn continuous transmit on, the terminal continuously sends out a string of 10 characters. F5

Exits the Serial Port Test diagnostic screen.

On the host, you use an RS-232 serial communications package to receive data from the terminal. To test serial communications, enter or scan data on the terminal. If the terminal is communicating with the host, you will see the data. If there is a problem, check the serial port parameters and make sure they match the host settings. For help with serial port errors, contact your local Intermec service representative.

7-23

Page 295

TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual Nugg Co de 39

Subsystem Versions Purpose:

Where Available: Sample Screen:

If you are discussing a problem with Intermec, you can use the Subsystem Versions screen to tell the Intermec representative the exact version of firmware subsystems loaded on the terminal. System Diagnostics menu SUBSYSTEM Name UDP+ RF Driver Decodes Scanner Term Serv XMODEM Serial Port Keypad Label Task Menu System

[Enter] Next [Esc] Exit

VERSIONS Version 031000 031000 031000 031000 031000 031000 031000 031000 031000 031000 screen

2455U.125

Definition:

7-24

Press to display the next screen of subsystem information. If you are having a specific problem with one system, note the version loaded on the terminal before contacting your local Intermec service representative.

Page 296

Nugg

Running Diagnostics Co de 39

7

Error Numbers and Messages This table lists the error numbers that are posted to the second column on the Error Logger screen and lists the message associated with each number. You can use this information to help you interpret the errors logged for the terminal. Error Number

Message

0x51

Response larger than buffer

0x52

Reader command is invalid

0x53

Set attribute with bad value

0x54

Write to read-only attribute

0x55

General error not covered

0x56

Incorrect parameter or string length

0x57

Queue or pool empty

0x58

Action not permitted from this origin

0x59

Indicates that a DLE character has been found

0x5A

During configuration parsing, a digit was expected

0x5B

Configuration item is invalid

0x5F

Event out of sync with queue

0x60

Queue is full

0x61

UDP+: Buffer too large to send

0x62

UDP+: NULL buffer was passed

0x63

UDP+: Message received bigger than buffer

0x64

UDP+: Message already transmitted

0x65

UDP+: Invalid parameter block

0x66

Network not active or not configured properly

0x67

NCB pointer is null

0x68

Data pointer is null or data length invalid

0x69

Network error

0x6A

Previous application message occupies send buffer

0x6B

Network error

0x6C

Network error

0x6D

Network error

0x6E

Network error

7-25

Page 297

TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual Nugg Co de 39

Error Numbers and Messages Table (continued)

7-26

Error Number

Message

0x6F

An attempt was made to establish a new TCP connection

0x70

The Ninit usnet call failed

0x71

The Nportinit usnet call failed

0x72

The Nterm usnet call failed

0x73

The Portterm usnet call failed

0x74

The Nopen usnet call failed

0x75

The Nclose usnet call failed

0x76

The Nread usnet call failed

0x77

The Nwrite usnet call failed

0x78

Invalid group event

0x79

Network PM failed

0x7A

Invalid send buffer

0x7B

The send buff is not empty

0x7C

A failure occurred in UDP timer

0x7D

Maximum number of bad sequences

0x7E

Could not connect to controller

0x80

File open failed

0x81

Read or write request failed

0x82

The getbuf usnet call failed

0x83

Data or ACK receive failed

0x84

File write failed

0x85

File close failed

0x86

Controller denied request

0x87

Network activate off

0x90

Card: unknown command to driver

0x91

Card: invalid code

0x92

Card: process response

0x93

Card: offset too big

0x94

Card: entry not in hash list

0x95

Card: security ID

0xA1

Invalid sub-function request

Page 298

Nugg

Running Diagnostics Co de 39

Error Number

Message

0xA2

Table is full

0xA3

Index out of range

0xA4

Time value at that index is zero

0xA5

Pointers do not match

0xA6

Requested row value not supported

0xA7

Requested column value not supported

0xA8

Invalid command

0xA9

Invalid configuration combination

0xAA

Invalid viewport request

0xAC

No description available

0xAD

Invalid logical key requested

0xAE

Invalid modifier requested

0xB0

Invalid device

0xC0

IP format 0.x.x.x or 127.x.x.x

0xC1

Controller and device IP same

0xC2

Default router and device IP same

0xC3

Default router not on device network

0x110

No TCB slot available

0x111

No RAM available for stack

0x112

Invalid time

0x113

Invalid slot

0x114

Invalid delay type

0x115

Invalid event

0x116

Invalid group event

0x117

Invalid resource

0x118

Invalid mailbox

0x119

Invalid memory release

0x11A

Function timeout expired

0x11B

Periodic event table full

0x11C

Invalid profile_type code

0x11D

Invalid MMU180 page number

0x11E

Device not open

0x11F

Device not open or not device owner

7

7-27