The text of a manual · part 37 of 59
Trakker Antares 24XX Terminal User's Manual Addendum: Chapter 7 - Running Diagnostics, pages 290 to 298
Pages 290 to 298 of 501, from Trakker Antares 24XX Terminal User's Manual Addendum
The original document is the PDF (2.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 2455
Page 290
Nugg
Running Diagnostics Co de 39
7
Serial Loopback Purpose:
Where Available: Sample Screen:
Use the Serial Loopback test to verify that the hardware for the RS-232 serial port is functioning correctly. To run this diagnostic test, you must connect the terminal to a host computer or other serial device. Choose the Main Board Menu from the Hardware Diagnostics menu. SERIAL
PORT
LOOPBACK
WAITING /CTS 0 COM Port :1 Baud Rate :38400 Parity :None Data Bits :8 Echo RX Data on TX Echo /CTS on /RTS
[Esc]
Exit
2455U.119
Definition:
The serial port test begins immediately. If the serial port hardware is functioning correctly, the terminal displays WAITING and then RECEIVING. The Serial Loopback test uses the serial communications settings that are listed on the bottom half of the screen. On the host, you can use a serial communications package to send data to the terminal. If the terminal is communicating with the host, the data is echoed back. If there is a problem, an error message appears on the terminal screen. The status information on the screen is updated every 500 ms. For help with serial port errors, contact your local Intermec service representative.
7-19
Page 291
TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual Nugg Co de 39
Defining the System Diagnostics Screens Each system diagnostic screen is defined in this section.
Access Point Purpose:
Where Available:
Use the Access Point screen to get version and address information about the access point the terminal is communicating with across the 2.4 GHz RF network. System Diagnostics menu
Sample Screen:
ACCESS Radio ROM V1.6EB
POINT
Ver:
Radio MAC Addr: 0020A6306510 Access Point SHIPPING
Name:
Access Point 0020A6301365
MAC:
[Esc]
Exit
2455U.120
Definition:
7-20
The screen displays the radio ROM firmware version, radio MAC (machine) address, the access point name, and the access point MAC. If you have a problem with the radio or the connection to the access point, use the information on this screen to troubleshoot your network configuration.
Page 292
Nugg
Running Diagnostics Co de 39
7
Application Efficiency Purpose:
Where Available: Sample Screen:
Use the Application Efficiency screen to find out if your application is making the best use of and maximizing battery life on the terminal. System Diagnostics menu APP EFFICIENCY Subsystem Versions Application is running at 90% 80%
100% POOR
GOOD
Battery life affected by application efficiency. [Esc] is
Exit 2455U.121
Definition:
The screen displays the application efficiency percentage. The closer the percentage is to 100%, the more efficient the application is at using battery power. The terminal automatically goes into an internal Standby mode to draw power at a lower level when less power is required. An efficient application uses the TRAKKER Antares PSK (Programmer’s Software Kit) functions to wait for events to occur and it does not poll in an infinite loop. When programmed correctly with the PSK or EZBuilder, the application does not prevent the terminal from going into Standby mode and uses the terminal’s battery power as efficiently as possible.
7-21
Page 293
TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual Nugg Co de 39
Malloc Application Information Purpose:
Where Available: Sample Screen:
A programmer or application developer can use the Malloc Application Information screen to see how memory is allocated and used by the current application. Choose the Malloc Info Menu from the System Diagnostics menu. APPLICATION Total Free: 0000064656 Largest Free: 0000064656 Fragments: 00001 Allocated Blocks: 00001
OK 2455U.122
Definition:
The screen displays the memory allocation used by the application. You can view the total free memory, largest block of free memory, number of memory fragments, and total number of allocated blocks of memory. Use this diagnostic screen to troubleshoot a memory leak where the application is mallocing memory, but not freeing memory.
Malloc Firmware Information Purpose:
Where Available: Sample Screen:
A programmer or application developer can use the Malloc Firmware Information screen to see how memory is allocated and used in the terminal firmware. The firmware includes the operating environment, firmware, drivers, and TRAKKER Antares 2400 Menu System. Choose the Malloc Info Menu from the System Diagnostics menu. FIRMWARE Total Free: 0000007040 Largest Free: 0000006768 Fragments: 00002 Allocated Blocks: 00015
OK 2455U.123
7-22
Page 294
Nugg
Definition:
Running Diagnostics Co de 39
7
The screen displays the memory allocation for the terminal firmware. You can view the total free memory, the largest block of free memory, number of memory fragments, and the total number of allocated blocks of memory.
Serial Port Test Purpose:
Where Available:
Use the Serial Port Test screen to test or troubleshoot serial communications between the terminal and the host computer or serial device. To run this diagnostic test, you must connect the terminal to a host or other serial device. System Diagnostics menu
Sample Screen:
SERIAL
PORT
Select Com. 1,4, Esc :
TEST
Port: 1
F1:Port Select :1 F2:Keypad Echo : ON F3:Scanner Echo: ON F4:Continous TX: OFF F5:Exit -
2455U.124
Definition:
Press to test the RS-232 serial communications port. The screen displays the function key options you can use in this diagnostic screen. You may see the message “Port Not Available” if your application is currently using the serial port. You need to run an application that does not use the serial port for this diagnostic test. F1
Selects the serial port.
F2 Toggles the keypad echo on and off. If you turn the keypad echo on, characters you type on the keypad or keyboard are displayed on the bottom line of the screen and transmitted to the host. F3 Toggles the scanner echo on and off. If you turn the scanner echo on, the bar code label you scan is displayed on the bottom line of the screen and transmitted to the host. F4 Toggles the Continuous Transmit mode on and off. If you turn continuous transmit on, the terminal continuously sends out a string of 10 characters. F5
Exits the Serial Port Test diagnostic screen.
On the host, you use an RS-232 serial communications package to receive data from the terminal. To test serial communications, enter or scan data on the terminal. If the terminal is communicating with the host, you will see the data. If there is a problem, check the serial port parameters and make sure they match the host settings. For help with serial port errors, contact your local Intermec service representative.
7-23
Page 295
TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual Nugg Co de 39
Subsystem Versions Purpose:
Where Available: Sample Screen:
If you are discussing a problem with Intermec, you can use the Subsystem Versions screen to tell the Intermec representative the exact version of firmware subsystems loaded on the terminal. System Diagnostics menu SUBSYSTEM Name UDP+ RF Driver Decodes Scanner Term Serv XMODEM Serial Port Keypad Label Task Menu System
[Enter] Next [Esc] Exit
VERSIONS Version 031000 031000 031000 031000 031000 031000 031000 031000 031000 031000 screen
2455U.125
Definition:
7-24
Press to display the next screen of subsystem information. If you are having a specific problem with one system, note the version loaded on the terminal before contacting your local Intermec service representative.
Page 296
Nugg
Running Diagnostics Co de 39
7
Error Numbers and Messages This table lists the error numbers that are posted to the second column on the Error Logger screen and lists the message associated with each number. You can use this information to help you interpret the errors logged for the terminal. Error Number
Message
0x51
Response larger than buffer
0x52
Reader command is invalid
0x53
Set attribute with bad value
0x54
Write to read-only attribute
0x55
General error not covered
0x56
Incorrect parameter or string length
0x57
Queue or pool empty
0x58
Action not permitted from this origin
0x59
Indicates that a DLE character has been found
0x5A
During configuration parsing, a digit was expected
0x5B
Configuration item is invalid
0x5F
Event out of sync with queue
0x60
Queue is full
0x61
UDP+: Buffer too large to send
0x62
UDP+: NULL buffer was passed
0x63
UDP+: Message received bigger than buffer
0x64
UDP+: Message already transmitted
0x65
UDP+: Invalid parameter block
0x66
Network not active or not configured properly
0x67
NCB pointer is null
0x68
Data pointer is null or data length invalid
0x69
Network error
0x6A
Previous application message occupies send buffer
0x6B
Network error
0x6C
Network error
0x6D
Network error
0x6E
Network error
7-25
Page 297
TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual Nugg Co de 39
Error Numbers and Messages Table (continued)
7-26
Error Number
Message
0x6F
An attempt was made to establish a new TCP connection
0x70
The Ninit usnet call failed
0x71
The Nportinit usnet call failed
0x72
The Nterm usnet call failed
0x73
The Portterm usnet call failed
0x74
The Nopen usnet call failed
0x75
The Nclose usnet call failed
0x76
The Nread usnet call failed
0x77
The Nwrite usnet call failed
0x78
Invalid group event
0x79
Network PM failed
0x7A
Invalid send buffer
0x7B
The send buff is not empty
0x7C
A failure occurred in UDP timer
0x7D
Maximum number of bad sequences
0x7E
Could not connect to controller
0x80
File open failed
0x81
Read or write request failed
0x82
The getbuf usnet call failed
0x83
Data or ACK receive failed
0x84
File write failed
0x85
File close failed
0x86
Controller denied request
0x87
Network activate off
0x90
Card: unknown command to driver
0x91
Card: invalid code
0x92
Card: process response
0x93
Card: offset too big
0x94
Card: entry not in hash list
0x95
Card: security ID
0xA1
Invalid sub-function request
Page 298
Nugg
Running Diagnostics Co de 39
Error Number
Message
0xA2
Table is full
0xA3
Index out of range
0xA4
Time value at that index is zero
0xA5
Pointers do not match
0xA6
Requested row value not supported
0xA7
Requested column value not supported
0xA8
Invalid command
0xA9
Invalid configuration combination
0xAA
Invalid viewport request
0xAC
No description available
0xAD
Invalid logical key requested
0xAE
Invalid modifier requested
0xB0
Invalid device
0xC0
IP format 0.x.x.x or 127.x.x.x
0xC1
Controller and device IP same
0xC2
Default router and device IP same
0xC3
Default router not on device network
0x110
No TCB slot available
0x111
No RAM available for stack
0x112
Invalid time
0x113
Invalid slot
0x114
Invalid delay type
0x115
Invalid event
0x116
Invalid group event
0x117
Invalid resource
0x118
Invalid mailbox
0x119
Invalid memory release
0x11A
Function timeout expired
0x11B
Periodic event table full
0x11C
Invalid profile_type code
0x11D
Invalid MMU180 page number
0x11E
Device not open
0x11F
Device not open or not device owner
7
7-27