Trakker Antares 24XX Terminal User's Manual Addendum: Chapter 4 - Operating the Terminal in a Network, pages 206 to 213

Pages 206 to 213 of 501, from Trakker Antares 24XX Terminal User's Manual Addendum

The original document is the PDF (2.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Intermec 2455

Page 206

nugget CODE39 Operating the Terminal in a Network

4

KA1 enables the Keypad Caps Lock configuration command.

.+1 is the reader command that saves configuration changes to the terminal’s flash memory.

The terminal returns this transaction to the host application. Cs$+BV4KA1.+1 where: Cs is a TMF Configuration Set response.

$+ is the Change Configuration reader command.

BV4 means the Beep Volume configuration command was changed to a value of 4, which is a very loud beep volume.

KA1 means the Keypad Caps Lock configuration command was enabled.

.+1 means the configuration changes were saved in flash memory.

Using RF Communications on the Terminal Before you can begin using the TRAKKER Antares 2455 terminal to collect data, you need to install and configure each device in the 2.4 GHz RF network: 1. Plan and prepare your network. Make sure you have unique IP addresses for all devices in the network. Make sure you have all the equipment required to use the T2455 in the RF network. 2. For a T2455 with UDP Plus, configure the DCS 300 server or the Model 200 Controller. Note: The T2455 will communicate with either the DCS 300 or the Model 200 Controller. The DCS 300 is a new data collection server that replaces the Model 200 Controller. 3. Configure the access points. 4. Configure each T2455 terminal. Each step is described in detail in the next sections. Caution Make sure all components with antennas are at least 1 foot (0.3 meters) apart when power is applied. Failure to comply could result in equipment damage. Conseil Assurez-vous que la distance entre tous les éléments avec antennes soit d'au moins un pied (0.3 mètres) avant de faire la connexion avec l'alimentation électrique, faute de quoi vous risquez d'endommager votre installation.

4-9

Page 207

TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual nugget CODE39

How the T2455 Fits Into Your RF Network The TRAKKER Antares 2455 terminal is a versatile terminal that you can easily add to your network or data collection system. You can use the T2455 as an end device in Intermec’s 2.4 GHz RF network. The illustrations in this section show some examples of the types of network configurations in which you can use the terminal.

TRAKKER Antares 2455 Terminals in a 2.4 GHz RF Network Host TCP/IP Direct Connect

UDP Plus

Ethernet

Access point

T2455

DCS 300

2455U.048

Access point

T2455

In a UDP Plus network, the T2455 communicates with a host computer through the DCS 300 using UDP Plus for the RF protocol. In a TCP/IP direct connect network, the T2455 communicates with a host computer directly using TCP/IP for the RF protocol. The access point acts as a bridge to allow communications between the Ethernet or token ring network and the wireless T2455 terminals.

4-10

Page 208

nugget CODE39 Operating the Terminal in a Network

4

TRAKKER Antares 2455 Terminals in Multiple Subnetworks (UDP Plus) DCS 300 192.9.175.7 Router

Access point

T2455 terminal 192.9.200.5

Ethernet

T2455 cannot roam between subnetworks

192.9.200.X subnetwork

Access point

192.9.175.X subnetwork

Access point

T2455 terminals 192.9.175.10 192.9.175.11

2455U.083

You can install the T2455 terminals, access points, and DCS 300 in your 2.4 GHz RF network as shown in the illustration. The T2455 terminals may only communicate with the access points that are in the same IP subnetwork. In this example, all the terminals and access points communicate with the DCS 300 at IP address 192.9.175.7 using UDP Plus for the RF protocol. Note: If you are using the 21XX Universal Access Point™ (UAP), the T2455 terminal can roam between subnetworks. If you are using the 01XX access point, the T2455 cannot roam between subnetworks.

4-11

Page 209

TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual nugget CODE39

TRAKKER Antares 2455 Terminals in Multiple Subnetworks (TCP/IP) Host

192.9.175.7

Router

Access point

T2455 terminals 192.9.200.5, 192.9.200.6

Ethernet

T2455 cannot roam between subnetworks

192.9.200.X subnetwork

Access point

192.9.175.X subnetwork

Access point

T2455 terminals 192.9.175.10 192.9.175.11

2455U.084

You can install the T2455 terminals and access points in your 2.4 GHz RF network as shown in the illustration. The T2455 terminals may only communicate with the 01XX access points that are in the same IP subnetwork. In this example, all the terminals and access points communicate with the host at IP address 192.9.175.7 using TCP/IP for the RF protocol. Note: If you are using the 21XX Universal Access Point™ (UAP), the T2455 terminal can roam between subnetworks. If you are using the 01XX access point, the T2455 cannot roam between subnetworks.

4-12

Page 210

nugget CODE39 Operating the Terminal in a Network

4

TRAKKER Antares 2455 Terminals Communicating Across Subnetworks (UDP Plus) DCS 300 192.9.200.5 192.9.200.X subnetwork

Router

192.9.175.X subnetwork Ethernet

192.9.175.1

Access point T2455 terminals 192.9.175.9 192.9.175.10 192.9.175.11

2455U.089

You can install the T2455 terminals and access points in one IP subnetwork and install the DCS 300 in another IP subnetwork as shown in the illustration. In this network, you must configure additional network parameters (default router and subnet mask) as described later in this chapter. Note: If you are using the 21XX Universal Access Point™ (UAP), the T2455 terminal can roam between subnetworks. If you are using the 01XX access point, the T2455 cannot roam between subnetworks.

4-13

Page 211

TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual nugget CODE39

Planning the Network Connection To use the T2455 in the 2.4 GHz RF network, you need these minimum requirements: • •

DCS 300 (only T2455 with UDP Plus) Access point

When you first consider purchasing a wireless data collection system, an Intermec representative works with you to perform a site survey at your facility. The site survey analyzes the range of radio frequency devices in your facility and determines the placement of the access points. The site survey ensures that the coverage of each access point overlaps to provide uninterrupted wireless access at any location within the building. This manual assumes that a site survey is complete and the access points are installed in your facility. You need to work with your network administrator to plan and assign the IP address for each device in the 2.4 GHz RF. You must assign and set the IP address for each access point (RF) and each T2455 terminal. For a T2455 with UDP Plus, you must also assign an IP address to the DCS 300.

Configuring the DCS 300 The DCS 300 server supports and manages communications with other devices in the 2.4 GHz RF network. When you install and configure the DCS 300, you identify the host computer(s) and T2455 terminals in your network. The terminals communicate through the DCS 300 with your host by using UDP Plus protocol. For help installing the DCS 300, see the DCS 300 System Manual (Part No. 067296). Note: You can use a T2455 running TCP/IP protocol and the DCS 300 in a passthrough network. You establish a direct TCP/IP socket connection from the T2455 to the host through the DCS 300. For more information, see the DCS 300 System Manual. To have the T2455 communicate with the DCS 300, you must configure these parameters on the server: •

Configure the UDP Plus network.

•

Assign an IP address to each T2455.

•

Enable all T2455 terminals.

•

Define the host environment parameters, which includes configuring for terminal emulation, screen mapping, or client/server applications.

•

Define the host communications parameters, which includes the physical connection (network adapter cards) to the host.

To do screen mapping on the DCS 300, you must:

4-14

• create the script file using the Script Builder tool on the server.

• create an application using EZBuilder and download it to the T2455.

Page 212

nugget CODE39 Operating the Terminal in a Network

4

Configuring the Access Point The access point acts as a bridge to provide RF communications between the T2455 terminal and the DCS 300 or host. For help, see your access point user’s manual. Note: If you are using the 21XX Universal Access Point™ (UAP), the T2455 terminal can roam between subnetworks. If you are using the 01XX access point, the T2455 cannot roam between subnetworks. To have the T2455 communicate with the access point, you must know the value of these parameters on the access point: •

RF domain

•

RF security identification (ID) (optional)

Configuring the T2455 When you install the T2455 terminal in a network, you must configure a set of network parameters that control how the terminal communicates in the network. There are two ways to configure the network parameters: •

Use the TRAKKER Antares 2400 Menu System. For help on configuring the network parameters, see Chapter 2, “Installing the Terminal.”

•

Scan the configuration command from a Code 39 or Code 93 bar code label. The configuration commands are listed alphabetically by command name in Chapter 9, “Configuration Command Reference.”

The set of network parameters you must configure depends on whether you install the terminal on the same IP subnetwork as the DCS 300 or host (TCP/IP), or on a different subnetwork. The next table lists the parameters you configure in each type of network. Same IP Subnetwork?

Different IP Subnetwork?

Time and date

X

X

Network activate

X

X

Controller IP address (UDP Plus)

X

X

Host IP address (TCP/IP)

X

X

Terminal IP address

X

X

Network port

X

X

RF domain

X

X

Optional

Optional

Network Parameters

RF security ID Default router

X

Subnet mask

X

The network parameters are defined in the next section.

4-15

Page 213

TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual nugget CODE39

Defining the Network Parameters This section defines the network parameters you configure when installing the T2455 terminal in an RF network. For each parameter’s syntax and options, see Chapter 9, “Configuration Command Reference.” Time and Date When you turn on the terminal for the first time, you must set the current time and date. You also need to set the time and date any time you lose all power to the terminal. For help, see “Setting the Time and Date” in Chapter 2. Network Activate On a T2455, the Network Activate command disables or enables RF communications. If the Network Activate parameter is disabled, the network is disabled, no RF communications are provided, and the radio is turned off. When the Network Activate parameter is enabled, the T2455 will try to connect to the access point or DCS 300. Controller IP Address An IP address is a unique network level address you assign to each device in a TCP/IP network. The Controller IP Address identifies the IP address assigned to the DCS 300 or Model 200 Controller in a UDP Plus network. Host IP Address An IP address is a unique network level address you assign to each device in a TCP/IP direct connect network. The Host IP Address identifies the IP address assigned to the host in your 2.4 GHz RF network. Terminal IP Address An IP address is a unique network level address you assign to each device in a TCP/IP network. The Terminal IP Address identifies the IP address assigned to the T2455. The IP address you set on the terminal must match the address that is set for the terminal on the DCS 300. Network Port Defines the network port that the TCP/IP or UDP Plus network protocol uses for communications in your 2.4 GHz RF network. In a UDP Plus network, the network port you set on the T2455 must match the network port that is set on the DCS 300. In a TCP/IP network, set the network port to the appropriate port for the application you are using on the T2455. The default network port of 23 enables VT/ANSI Telnet communications. RF Domain The domain defines a logical partition or subnetwork of the network. To establish communications, you must assign the same domain number to every RF device in a wireless network. The domain number you set on the terminal must match the domain that is set on each access point the terminal may communicate with. You can continue to collect data with the terminal as you roam between access points as long as all the devices have the same domain number. RF Security Identification (ID) This optional parameter defines the password you can set for secured transmission and receipt of data between devices in the wireless network. To communicate, each access point and terminal must have matching security IDs. If the security ID is set on the access point, you must also set the security ID on each T2455 that may communicate with the access point. Note: The Network Activate command must be configured to 2.4 GHz RF network before you can save any changes to the RF security ID parameter.