Trakker Antares 24XX Terminal User's Manual Addendum: Chapter 2 - Installing the Terminal, pages 146 to 153

Pages 146 to 153 of 501, from Trakker Antares 24XX Terminal User's Manual Addendum

The original document is the PDF (2.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Intermec 2455

Page 146

CODE39 Nugget Installing the Terminal

2

Configuring the Terminal to Communicate in Your Network You need to configure the T2455 to communicate with RF or serial devices in your network. Here are the parameters you need to set: •

Time and Date

•

RF communications

•

Serial port (COM1)

The next sections list the parameters you need to configure and explain how to use the TRAKKER Antares 2400 Menu System to configure the terminal.

Setting the Time and Date You need to set the time and date on the terminal so that all transactions are correctly date and timestamped. To set the time and date or scan this bar code to access the TRAKKER Antares

1. Press 2400 Menu System:

Enter Test and Service Mode

*..-.* *..-.*

The Main Menu appears.

2455U.044

V

2. Press to choose the System Menu and then press appears.

The System Menu

2-17

Page 147

TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual CODE39 Nugget

System Menu SYSTEM MENU File Manager Load Default Values Set Time and Date Store Configuration Upgrade Firmware ⁄

_` Select item [Enter] Next screen [F1] Help [Esc] Exit 2455U.046

V

3. Press to choose the Set Time and Date command and then press and Date screen appears.

TIME

AND

The Time

DATE

Current time 12:00:00 New time: 12:39:00 is

Current date is 1996/01/01 New date YYYY/MM/DD:

OK

CANCEL 2455U.047

V

4. Type the current time in the format HH MM SS (hours, minutes, seconds) with a space character ( ) between each field and then press . The program fills in the colon character in the time field. For example, to enter the time 04:05:03 P.M., type:

V

Note: The time is not actually updated until you exit the Time and Date screen. When you set the time, set the time ahead so that the correct time is saved when you exit the screen in Step 6.

V

5. Type the current date in the format YYYY MM DD (year, month, day) with a space character ( ) between each field and then press . The program fills in the slash character in the date field.

2-18

Page 148

CODE39 Nugget Installing the Terminal

2

For example, to enter the date August 9, 1998, type:

V 6. Press to save the changes and exit the Time and Date screen. 7. Press ] to exit the System Menu. The Main Menu appears. 8. If you want to configure the terminal for your RF network, continue with the next section, “Configuring RF Communications.” If you want to configure the serial port, follow the instructions for “Configuring the Serial Port Parameters” later in this chapter.

Configuring RF Communications The TRAKKER Antares 2455 terminal communicates with a host computer in Intermec’s 2.4 GHz RF network through the DCS 300, the Model 200 Controller, or directly through the access points. The terminal uses one of these RF network protocol options to communicate with other devices: •

UDP Plus

•

TCP/IP

The terminal ships with only one of these RF network protocols. In a UDP Plus network, the terminal communicates through the DCS 300 or Model 200 Controller to a host on an Ethernet, token ring, twinaxial, coaxial, or SDLC network. In a TCP/IP network, the terminal communicates through the access point, which is connected to the host on an Ethernet or token ring network. Note: The T2455 will communicate with either the DCS 300 or the Model 200 Controller. The DCS 300 is a new data collection server that replaces the Model 200 Controller. Host TCP/IP Direct Connect

UDP Plus

Ethernet

Access point

T2455

DCS 300

2455U.048

Access point

T2455

2-19

Page 149

TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual CODE39 Nugget

You need to configure these network parameters to begin using RF communications: Network Parameter

Default Value

Network activate

Disabled

Controller IP address (UDP Plus)

0.0.0.0

Host IP address (TCP/IP)

0.0.0.0

Terminal IP address

0.0.0.0

RF domain

0

RF security identification (ID)

None (not set)

Network port (UDP Plus)

5555

Network port (TCP/IP)

23

Use the TRAKKER Antares 2400 Menu System to set these parameters. For a detailed definition of these parameters, see Chapter 4, “Operating the Terminal in a Network.” Note: If the terminal is on a different IP subnetwork from the DCS 300, controller, or host, you must also configure the default router and subnet mask. To configure the terminal to use RF communications 1. Configure the DCS 300 (UDP Plus), Model 200 Controller (UDP Plus), or host (TCP/IP). For help, see your server, controller, or host system manual. 2. Configure the access point. For help, see your access point user’s manual.

: V

3. Configure the terminal. From the Main Menu, press or to choose the Configuration Menu and then press . The Configuration Menu appears.

4. Press V to choose the Communications Menu and then press The Communications Menu appears. 5. Press to choose the Primary Network command. The Primary Network screen Note: If you are not in the TRAKKER Antares 2400 Menu System, press to access the Main Menu.

appears.

2-20

Page 150

CODE39 Nugget Installing the Terminal

UDP Plus Primary Network

TCP/IP Primary Network

PRIMARY NETWORK

PRIMARY NETWORK

Activate: Disabled Controller IP Addr: 0.0.0.0 Terminal IP Address: 0.0.0.0

Activate: Disabled Host IP Addr: 0.0.0.0 Terminal IP Address: 0.0.0.0

OK

CANCEL

2

OK

CANCEL 2455U.049

W

6. Press to set the Network Activate command to 2.4 GHz RF. Press the next field.

V to move to

Enter the Controller IP address for a UDP Plus network. Enter the Host IP address for a TCP/IP network. Enter the Terminal IP address. IP address fields consist of four separate numbers. Each number in the field is separated by a period and can be a number from 0 to 255. Type the address in the format nnn.nnn.nnn.nnn and then press .

V

For example, if your terminal IP address is 192.100.100.3, type:

Note: The network cannot be activated if the first address segment in the IP address is set to 0, 127, or a number greater than 223.

to save the changes and exit the Primary Network screen. 8. Press V to choose the Radio command and then press The Radio screen 7. Press appears.

UDP Plus and TCP/IP Radio RADIO Domain: 00 Security ID: (ID unchanged) Wakeup on Broadcast: No Roam Flag: Allowed Transmit Mode: BFSK Inactivity Timeout: 5 sec OK

CANCEL 2455U.050

2-21

Page 151

TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual CODE39 Nugget

V . The domain In the Security ID field, type the RF security identification and then press V . The

9. In the Domain field, type a number from 0 to 15 and then press must match the number set on the access point.

Security ID is case-sensitive and can be up to 20 characters long. It must match the security ID set on the access point. Press to save the changes and exit the Radio screen.

Note: If the terminal is on a different IP subnetwork from the DCS 300, controller, or host, you must also configure the default router and subnet mask. Choose the Advanced Network command to set these parameters. For help, see Chapter 4, “Operating the Terminal in a Network.”

:

10. For TCP/IP networks, press to choose the Advanced Network command and then press . The Advanced Network screen appears. UDP Plus Advanced Network ADVANCED NETWORK Loopback: Disabled Network Port: 05555 Subnet Mask: 255.255.255.0 Default Router: 0.0.0.0 Controllr Connect Chk Send Timer:0035 sec Recv Timer:0060 sec Retries: 07

TCP/IP Advanced Network ADVANCED NETWORK Network Port: 00023 Subnet Mask: 255.255.255.0 Default Router: 0.0.0.0 TCP/IP Maximum Transmit Timeout: 020 sec

OK

CANCEL

` more 2455U.051

11. In the Network Port field, type a number from 1 to 65535 and then press . The default value is 23, which enables VT/ANSI Telnet communications. If you are not using Telnet communications, enter the port number used by your application. Note: For UDP Plus networks, the Network Port default is 5555, which matches the default value set on the DCS 300 and controller.

] to exit the Communications Menu. The Configuration Menu appears. 13. Press ] to exit the Configuration Menu. 14. Press to choose Yes and save the new configuration in RAM. Once the 12. Press changes are saved, the terminal uses the new configuration.

2-22

Page 152

CODE39 Nugget Installing the Terminal

2

Saving Configuration Changes in RAM Screen

Save new configuration (in

RAM)?

Yes

No

CANCEL

2455U.053

] to exit the TRAKKER Antares 2400 Menu System. 16. Press to choose Yes and store your changes permanently in flash memory. 17. Press to choose OK and exit the TRAKKER Antares 2400 Menu System. The 15. Press terminal tries to establish communications with the DCS 300, the controller, or the host.

For terminal emulation applications in a UDP Plus network, you need to configure the host name in the TE Configuration menu to establish communications. For help, see the TRAKKER Antares Terminal Emulation User’s Guide. Once the terminal connects, the login or initial screen for your application appears and the Connect status light remains on. You can begin using the terminal to collect data. Follow the instructions in the section, “Starting the Application and Using the Terminal” later in this chapter. Note: While the terminal is connecting to the DCS 300, controller, or host, the terminal ignores any input from the keypad, keyboard, or scanner. Wait until the terminal is connected before you try to enter any data.

Configuring the Serial Port Parameters You use the terminal serial ports to transfer data between the terminal and a serial device, such as a printer, scale, or PC. The terminal has two serial ports (COM1 and COM4) that support RS-232 communications. For help connecting a serial device to each COM port, see “Connecting to Serial Devices” earlier in this chapter. You must first select the communications protocol for the COM port. Depending on the protocol, you need to set some or all of these serial port parameters to have the terminal communicate with a serial device:

2-23

Page 153

TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual CODE39 Nugget

Serial Port Parameters Parameter

Default Value

Baud rate

19200

Commands via serial port

Enabled without TMF

Data bits

7

EOM (End of Message)

\x03 (hexadecimal ASCII value for ETX)

Flow control

None

Handshake

Disabled

LRC

Disabled

Parity

Even

Poll (Polling)

Disabled

Serial Port Protocol

Configurable

SOM (Start of Message)

\x02 (hexadecimal ASCII value for STX)

Stop bits

1

Timeout delay

10 seconds

The values you set for the terminal serial port must match the values set for the device’s serial port. You use the TRAKKER Antares 2400 Menu System to set the parameters on the terminal. For a detailed definition of these parameters, see Chapter 4, “Operating the Terminal in a Network.” To set the serial port parameters 1. From the Main Menu, choose the Configuration Menu and then press Configuration Menu appears.

The

Note: If you are not in the TRAKKER Antares 2400 Menu System, press to access the Main Menu.

CONFIGURATION

MENU

Symbologies Menu Communications Menu Terminal Menu

⁄

_` Select item [Enter] Next screen [F1] Help [Esc] Exit 2455U.054

2-24