Page 289

Chapter 6, Programming

VT52 Mode Escape Sequence The terminal does not support VT52 mode, which allows the VT/ANSI Terminal to operate with DEC software written for VT52 Terminals.

Define Area Qualification The define area qualification (DAQ) command indicates that the active position is the first character position of a qualified area. The end of a qualified area is indicated by the beginning of the following qualified area. The qualifications of the area are specified according to the parameter(s). The following table lists qualification sequences. Note: DAQ is ignored unless the terminal is in VT340 mode.

Qualification

Sequence and Ps (Single Parameter)

Action

Accept all input

CSI 0 o

Accepts all input

Accept no input (protected) and do not transmit (guarded)

CSI 1 o

Accepts no input

Accept graphics

CSI 2 o

Accepts graphics

Accept numerics

CSI 3 o

Accepts numerics

Accept alphabetics

CSI 4 o

Accepts alphabetics

Right justify in area

CSI 5 o

Right justifies area

Zero fill in area

CSI 6 o

Fills area with zeros.

Horizontal tab stop at start of area

CSI 7 o

Puts horizontal tab stop at start of area

Accepts no input (protected), but select for transmission (unguarded)

CSI 8 o

Accepts no input

Space fill in area

CSI 9 o

Fills area with spaces

Invisible

CSI 1 0 o

Makes passwords invisible

Private Sequences Private sequences enable or disable autosend. Mode

Sequence*

Action

Set

ESC [ = 3 l

Enables autosend. Transmits the screen when the last field is filled. If you are on the last defined field and get data from the bar code reader or RS-232 port, the display will also be automatically sent even if the field not filled.

Reset

ESC [ = 3 h

Disables autosend. Only transmits when a terminating key is pressed.

*

The last character of the set mode sequence is lowercase L (6C hexadecimal).

TE 2000 VT/ANSI Terminal Emulation Programmer’s Guide

265

Page 290

Chapter 6, Programming

Proprietary Sequences Following are INTERMECR extensions to the data stream.

Line Edit and Character Modes Two proprietary escape sequences enable the host to put the terminal into Line Edit (block) mode or Character mode. Note that the terminal enters Character mode when it is cold-started. Mode

Sequence*

Line Edit

CSI = 1 l

Character

CSI = 1 h

*

The last character of the Line Edit sequence is lowercase L (6C hexadecimal).

Norcompress The Norcompress function handles the norrc command, where “a” is the number of iterations that “b” occurs in the datastream. The sequence for Norcompress is CSI a;bz.

Scanner Lock Mode Scanner lock mode is similar to the KAM function; however, you do not need to repeatedly send the Locked command (this command is assumed after each scan). Mode

Sequence*

Action

Set

CSI = 4 h

The host sends this sequence, which puts the terminal into Scanner Lock mode. When the terminal is in this mode, only one scan is allowed; the scanner is then inhibited. After this sequence is sent, the user can scan only once (no additional scans are allowed). To re-enable the scanner, the host must send CSI 2 l to unlock the scanner.

Reset

CSI = 4 l

Resets Scanner Lock mode (default).

*

The last character of the reset sequence is lowercase L (6C hexadecimal).

The scanner lock state can also be reset by the RIS command (ESC c) or the DECSTR command (CSI ! p).

266

TE 2000 VT/ANSI Terminal Emulation Programmer’s Guide

Page 291

Chapter 6, Programming

VT340 Applications VT340 Terminal applications supported by the terminal include setting the right margin, using control functions, and creating text forms.

Right Margin The terminal’s display contains 2 to 80 columns. To ensure that the cursor will not go beyond Column Pn, use the following sequence to set the number of columns (Pn is a number from 2 to 80): CSI Pn $ ¦

Control Functions In editing mode you can use the erasure, deletion, and insertion control functions. The character protection field lets you design text forms that cannot be changed or overwritten. In edit mode, character protection also depends on the setting of erasure mode (ERM): S If ERM is set all characters can be changed, erased, and moved, regardless of protection. S If ERM is reset only unprotected characters can be changed, erased, and moved. These control functions will not affect protected areas in page memory: S Insert line (IL) S Delete line (DL) S Insert character (ICH) S Delete character (DCH) S Erase in display (ED) S Erase in line (EL) S Erase character (ECH)

TE 2000 VT/ANSI Terminal Emulation Programmer’s Guide

267

Page 292

Chapter 6, Programming

Text Forms When using C1 control characters SPA, EPA, SSA, and ESA to create forms on the host, the rows and columns to which the cursor moves must be in sequential order. The following shows some sequences that create a text form, start with the left column. Control Characters for Auto-Login Script File Sequence

Definition

Sequence

Definition

ESC [ 1; 1 H

Home cursor

ESC V

Start protected area

ESC [ 2 J

Clear screen

ESC [ 4; 1 H

Move cursor to Row 4, Col 1

ESC [ ? 10 h

Start local editing mode

“Lot:”

Display literal

ESC V

Start protected area

ESC [ 1 D

Move cursor back 1 position

ESC [ 1; 2 H

Move cursor to Row 1, Col 2

ESC W

End protected area

“Manufacturing”

Display literal

ESC [ 1 C

Move cursor forward 1 position

ESC [ 1 ; 17 H

Move cursor to Row 1, Col 17

ESC F

Start selected area

“Receiving”

Display literal

ESC [ 4; 9 H

Move cursor to Row 4, Col 9

ESC [ 2; 1 H

Move cursor to Row 2, Col 1

ESC G

End selected area

“LIP:”

Display literal

ESC V

Negative Acknowledge

ESC W

End protected area

ESC [ 5; 1 H

Move cursor to Row 5, Col 1

ESC [ 1 D

Move cursor back 1 position

“Qty:”

Display literal

ESC W

End protected area

ESC [ 1 D

Move cursor back 1 position

ESC [ l C

Move cursor forward 1 position

ESC W

End protected area

ESC F

Start selected area

ESC [ 1 C

Move cursor forward 1 position

ESC [ 2; 15 H

Move cursor to Row 2, Col 15

ESC F

Start selected area

ESC G

End selected area

ESC [ 5; 13 H

Move cursor to Row 5, Col 13

ESC V

Start protected area

ESC G

End selected area

ESC [ 3; 1 H

Move cursor to Row 3, Col 1

ESC V

Start protected area

“Item:”

Display literal

ESC [ 24; 80 H

Move cursor to Row 24, Col 80

ESC [ 1 D

Move cursor back 1 position

ESC W

End protected area

ESC W

End protected area

ESC [ 26 $ |

Set the number of Cols to 26

ESC [ 1 C

Move cursor forward 1 position

ESC [ 1; 8 r

Set top at 1, bottom at 8 Rows

ESC F

Start selected area

ESC [ 3 g

Clear tab stops

ESC [ 3; 16 H

Move cursor to Row 3, Col 16

ESC [ 2; 5 H

Move cursor to Row 2, Col 5

ESC G

End selected area

268

TE 2000 VT/ANSI Terminal Emulation Programmer’s Guide

Page 293

Chapter 6, Programming

If this information is entered on the form: 111111111 2222222222 3333 44444444 for “LIP:” for “Item:” for “Lot:” for “Qty:”

The data stream will be sent to the host as indicated in the following chart. (If guarded area transfer mode (GATM) is reset, then the record separator is processed as a protected field entry.) Sequence

Definition

Sequence

Definition

RS

Protected field Line 1

3333

Selected field Line 4

RS

First protected field Line 2

RS

Second protected field Line 4

111111111

Selected field Line 2

RS

First protected field Line 5

RS

First protected field Line 3

44444444

Selected field Line 5

RS

First protected field Line 3

RS

Second protected field Line 5

2222222222

Selected field Line 3

RS

Protected field Line 6

RS

Second protected field Line 3

RS

Protected field Line 7

RS

First protected field Line 4

RS

Protected field Line 8

ANSI Mode Sequences Cursor Positioning The terminal supports cursor positioning sequences in the following table. Name (Mnemonics)

Sequence

Action

Cursor backward tab (CVT)

CSI Ps Z

Moves the cursor to previous Ps tab stop(s). If there is no previous tab stop, then the cursor moves to the left margin.

Cursor horizontal absolute (CHA)

CSI Ps G

Moves the cursor to the Ps column on the current line.

Cursor horizontal tab (CHT)

CSI Ps I

Moves the cursor to the next Ps tab stop(s). If there is not next tab stop, then the cursor moves to the right margin.

Cursor next line (CNL)

CSI Ps E

Moves the cursor down Ps lines. If at the bottom margin of the screen, then the cursor is not moved.

Cursor previous line (CPL)

CSI Ps F

Moves the cursor up Ps lines. If at the top margin of the screen, then the cursor is not moved.

Horizontal position absolute (HPA)

CSI Ps

Moves the cursor to Ps column on the current line.

Horizontal position relative (HPR)

CSI Ps a

Moves the cursor Ps columns from the current location. If past the right margin, then the cursor is stopped at the right margin.

Vertical position absolute (VPA)

CSI Ps d

Moves the cursor to Ps row using the current column.

Vertical position relative (VPR)

CSI Ps e

Moves the cursor Ps rows from the current location. If at the bottom margin, the cursor is stopped at the bottom margin.

Cursor vertical tab (CVT)

CSI Ps Y

Moves the cursor down Ps vertical tab stops. If at the bottom margin, then the cursor is stopped.

TE 2000 VT/ANSI Terminal Emulation Programmer’s Guide

269

Page 294

Chapter 6, Programming

Cursor Tabulation Control The following table lists cursor tabulation control (CBT) sequences in ANSI mode. Sequence

Action

CSI 0 W

Sets horizontal tab stop at current location.

CSI 1 W

Sets vertical tab stop at current location.

CSI 2 W

Clears horizontal tab stop.

CSI 3 W

Clears vertical tab stop.

CSI 4 W

Clears all horizontal tab stops this line.

CSI 5 W

Clears all horizontal tabs stops in the machine.

CSI 6 W

Clears all vertical tab stops

Scrolling The following table lists scrolling sequences in ANSI mode. Name (Mnemonics)

Sequence

Action

Scroll up (SU)

CSI Ps S

Scrolls display up Ps lines.

Scroll down (SD)

CSI Ps T

Scrolls display down Ps lines.

Transmitted Keyboard Codes Transmitted codes are generated by the terminal’s keys and sent to the host computer or software application in use. The following pages describe the capability of the terminals to emulate codes generated by the VT/ANSI terminal keyboard’s main keypad, editing keypad, auxiliary keypad, and top-row function keys. Codes are sent via Line Edit (block) mode or optimized Character mode selected through the keyboard function labeled MODE on the overlay.

Line Edit (Block) Mode Line Edit (block) mode is a synchronous condition where the terminal temporarily stores or “buffers” keys you press. It sends the cumulative data to the host computer when you press one of these terminating keys: S [Enter] S [F6] through [F20], [PF1] through [PF4] S [CTRL]+[A] through [CTRL]+[Z] S Forward Tab S DEL (7F hexadecimal) S Backspace

270

TE 2000 VT/ANSI Terminal Emulation Programmer’s Guide

Page 295

Chapter 6, Programming

The following also apply to Line Edit (block) mode: S When you press [PF1], the following key will also be transmitted directly to the host computer. S When scanning, the terminal automatically enters Line Edit (block) mode for each individual scan. When it completes scanning, it returns to the mode it was set at before it started scanning. For codes generated by the cursor control key, see page 272. For codes generated by the auxiliary keypad keys, see page 273.

Character Mode Character mode (the default) is a condition where the terminal sends, to the host computer, each key as you press it. You should place the terminal into Character mode during these situations: S When the terminal should immediately send information to the host computer. This operation is called “type-ahead.” S When the terminal’s keyboard sends a character to the display as well as to the host. This operation is called “local echo.” If local echo is disabled, the host receives the character from the terminal and then sends the return response. To alternate between Line Edit (block) mode and Character mode, press the mode key as defined under “Transmission Mode” in Chapter 3, “Using the Terminal’s Keyboard.”

Transmitted Keyboard Keys The following pages describe codes generated by main keypad keys, editing keys, auxiliary keys, and top-row function keys.

Main Keypad The terminal emulates all of the standard and most of the special function keys on the VT/ANSI main keypad. The standard keys generate letters, numbers, and symbols, either alone or in combination with other keys. The function keys generate special function codes. The following table lists the codes generated by the special function keys. VT/ANSI Key Code Ctrl

Does not send a code when used alone. Is always used in combination with another key to send a control code.

Delete

DEL (7F hexadecimal).

Lock

None.

Return

CR (0D hexadecimal) or CR (0D hexadecimal) LF (0A hexadecimal).

Shift

Does not send a code when used alone; sends uppercase characters when used with other standard keys.

Space bar

SP (20 hexadecimal).

Tab

HT (09 hexadecimal).

TE 2000 VT/ANSI Terminal Emulation Programmer’s Guide

271

Page 296

Chapter 6, Programming

Editing Keypad The terminal has editing keys and cursor control keys. Editing keys have functions assigned to them by the application software in use. Refer to your VT/ANSI application software manual for the uses of the editing keys.

Editing Keys The following table lists the codes generated by the editing keys. Note: The editing keys do not send codes in VT100 mode. VT/ANSI Key Code Find

CSI 1 ∼

Insert here

CSI 2 ∼

Next screen

CSI 6 ∼

Prev screen

CSI 5 ∼

Remove

CSI 3 ∼

Select

CSI 4 ∼

Cursor Keys The following table lists codes generated by the terminals’ cursor keys. Key

Cursor Key Mode Reset (Normal)

Cursor Key Mode Set (Application)

Down arrow CSI B

SS3 B

Left arrow

CSI D

SS3 D

Right arrow

CSI C

SS3 C

Up arrow

CSI A

SS3 A

Sending Host Cursor Keys In keyboard unshifted and shifted modes, the cursor control key sends a host cursor key to the host computer. The cursor control key emulates the arrow keys of a VT/ANSI Terminal in either their normal arrow key mode or Application mode, depending on the state set by the programmer.

272

To Send

Press Terminal Keys

Host cursor down key

[B]

Host cursor left key

[A ]

Host cursor right key

["]

Host cursor up key

[Y]

Host cursor down key

[SFT]+[B]

Host cursor left key

[SFT]+[A]

Host cursor right key

[SFT]+["]

Host cursor up key

[SFT]+[Y]

TE 2000 VT/ANSI Terminal Emulation Programmer’s Guide

Page 297

Chapter 6, Programming

Auxiliary Keypad Auxiliary keypad keys enter numeric data. The application software in use can also assign functions to these keys; refer to your VT/ANSI application software manual for their uses. The following table shows codes generated by the auxiliary keys in keypad Application mode. VT/ANSI Key

Keypad Mode

VT/ANSI Key

Keypad Mode

0

SS3 p

9

SS3 y

1

SS3 q

- (hyphen)

SS3 m

2

SS3 r

, (comma)

SS3 l

3

SS3 s

. (period)

SS3 n

4

SS3 t

Enter

SS3 M

5

SS3 u

PF1

SS3 P

6

SS3 v

PF2

SS3 Q

7

SS3 w

PF3

SS3 R

8

SS3 x

PF4

SS3 S

Top-Row Function Keys The following table lists function keys and the codes generated. Key

VT220/320/340 Mode

VT100 Mode

F5 (Break)

No code

No code

F6

CSI 1 7 ~

No code

F7

CSI 1 8 ~

No code

F8

CSI 1 9 ~

No code

F9

CSI 2 0 ~

No code

F10

CSI 2 1 ~

No code

F11

CSI 2 3 ~

Esc

F12

CSI 2 4 ~

BS

F13

CSI 2 5 ~

LF

F14

CSI 2 6 ~

No code

F15

CSI 2 8 ~

No code

F16

CSI 2 9 ~

No code

F17

CSI 3 1 ~

No code

F18

CSI 3 2 ~

No code

F19

CSI 3 3 ~

No code

F20

CSI 3 4 ~

No code

TE 2000 VT/ANSI Terminal Emulation Programmer’s Guide

273

Page 298

Chapter 6, Programming

Local Edit Mode If your application software program supports local editing, the terminal can be programmed to operate in Local Edit mode. Local Edit mode is a feature of the VT340 Terminal. Use the mode to send characters to page memory instead of to the host. The terminal sends a block of edited text to the host after you press a terminating key. Terminating keys in Local Edit mode are: S [Enter] S [F1] through [F20]

Edit Mode and Interactive Mode The edit mode control function (DECEDM) selects edit mode or interactive mode. The function determines when the terminal sends data to the host. The following Local Edit Modes table describes the modes. Mode

Sequence*

Action

Set

CSI ? 1 0 h

Selects edit mode. (Turns on the annunciator in the display.) The terminal stores all typed characters in page memory for local editing. After the data is edited, it can be sent in a block to the host.

Reset

CSI ? 1 0 l

Selects interactive mode. (Turns off the annunciator in the display.) The terminal immediately sends typed characters to the host.

*

The last character in the reset sequence is lowercase L (6C hexadecimal).

Local Editing Setup To use the terminal in Local Edit mode, the local editing features must be set up for the application software as described in the following table. Feature

Setting

Description

Edit mode

Edit

Edited text is stored in memory until you press a terminating key, which sends the text to the host.

Edit key execution mode

Not supported.

Transmit execution mode

Immediate

Local editing application keys

Suffix transmit When you press [F1] through [F20], the terminal sends that function to the host after sending a block of data.

Line transmit mode

Disabled

The terminal sends a full page of data to the host after you press a terminating key.

Transfer termination mode

Enabled

After you press a terminating key, the terminal sends the scrolling region, which is the area inside the scrolling margins.

VT131 transfer mode Space compression

The terminal sends data to the host immediately after you press a terminating key.

Not supported. Disabled

Terminal sends a space character for each unused character position

End of line characters

On the terminal, no characters indicate the EOL in a data block.

End of block characters

On the terminal, no characters indicate the end of a data block.

274