Page 233

Chapter 5, Customizing Your Configuration

S Send XON [Session 1].Send XON Session 2.Send XON [Enabled] Disabled S Telnet [Session 1].Telnet Session 2.Telnet Enabled [Disabled] S Terminal Mode [Session 1].Terminal Mode Session 2.Terminal Mode [7-Bit] 8-Bit S Terminal Setup [Session 1].Term Setup Session 2.Term Setup ANSI VT100 VT220 VT320 [VT340] S Transmit BS [Session 1].Transmit BS Session 2.Transmit BS Enabled [Disabled] S Use PC Character Set [Session 1].Use PC Char Set Session 2.Use PC Char Set Enabled [Disabled] S User Key Locked [Session 1].UserKey Locked Session 2.UserKey Locked Enabled [Disabled] S VT Cursor Mode [Session 1].VT Cursor Mode Session 2.VT Cursor Mode [Cursor] Application

TE 2000 VT/ANSI Terminal Emulation Programmer’s Guide

209

Page 234

Chapter 5, Customizing Your Configuration

S VT220 Mode [Session 1].VT220 Mode Session 2.VT220 Mode [Char] Block

Display Options S Backlight State [Session 1].Backlight State Session 2.Backlight State Enabled [Disabled] S Backlight Timer (not supported on 5020, 5055 DOS, 5055 .NET, CK30, CV60) [Session 1].Backlight Timer Session 2.Backlight Timer Numeric, minimum = [0], maximum = 60 (2415, 2425, 2435A, 2455, 2475, 248X) Numeric, minimum = [0], maximum = 255 (6400, 17XX, 11XX, 700 Series) S Contrast Mode (59XX, 17XX, 11XX) [Session 1].Contrast Mode Session 2.Contrast Mode [Compensated] Absolute S Cursor Mode [Session 1].Cursor Mode Session 2.Cursor Mode Underln Blink (2415, 2425, 2435A, 2455, 2475, 248X, 6400, 59XX, 17XX, 11XX) Block Blink (2415, 2425, 2435A, 2455, 2475, 248X, 6400, 59XX, 17XX, 11XX) Underline (6400, 5020, 5055 DOS, 59XX, 17XX, 11XX, 700 Series, CK30, CV60) Block (6400, 5020, 5055 DOS, 59XX, 17XX, 11XX, 700 Series, CK30, CV60) [Underln Blink] is the default for 2415, 2425, 2435A, 2455, 2475, and 248X Terminals. [Block] is the default for 6400, 5020, 5055 DOS, 59XX, 17XX, 11XX, 700 Series, CK30, and CV60 Terminals. S Remote Baud (17XX, 11XX) [Session 1].Remote Baud Session 2.Remote Baud 9600 19200 [38400]

210

TE 2000 VT/ANSI Terminal Emulation Programmer’s Guide

Page 235

Chapter 5, Customizing Your Configuration

S Remote Display (17XX, 11XX) [Session 1].Remote Disp Session 2.Remote Disp Enabled [Disabled] S Remote Display Remote Columns (17XX, 11XX) Session 1.Remote Cols Session 2.Remote Cols Numeric, minimum = 1, maximum = 255 [80] S Remote Display Remote Rows (17XX, 11XX) [Session 1].Remote Rows Session 2.Remote Rows Numeric, minimum = 1, maximum = 255 [24] S Remote Display Remote Type (17XX, 11XX) [Session 1].Remote Type Session 2.Remote Type VT100 VT220 [ANSI] S Software Input Panel Toggle (700 Series) [Session 1].SIP Toggle Session 2.SIP Toggle Enabled [Disabled]

Radio Communications Options Note: Radio Communications options do not apply to the 5020, 5055 .NET, 700 Series, CK30, or CV60 terminals, nor to 2415, 2425, 2435A, 2455, 2475, or 248X terminals that do not have an 802.1x supplicant radio driver installed. Set the Security ID for these terminals through the TRAKKER Antares 2400 Menu System. S Baud Rate (UHF radio) Radio Baud Rate 4800 4800/9600 9600 The default depends on the type of radio in the terminal. S Protocol (6400, 5055 DOS, 59XX, 17XX, 11XX) Radio Protocol The following qualifiers apply to UHF: RTC Adaptive Poll RTC-Diag Mode The following qualifiers apply to SST: SST SST-Diag Mode The default depends on the type of radio and is either RTC or SST. TE 2000 VT/ANSI Terminal Emulation Programmer’s Guide

211

Page 236

Chapter 5, Customizing Your Configuration

S Security ID [Session 1].Security ID Session 2.Security ID String, minimum length=0, maximum length=16 [null string] Default is NORANDOWL for 6400, 5055 DOS, 59XX, 17XX, 11XX. S User Authentication (2415, 2425, 2435A, 2455, 2475, 248X with 802.1x supplicant radio driver installed) [Session 1].User Auth Session 2.User Auth Enabled [Disabled]

More Options S Change Menu Password You must enable and set the password to access the Main Menu before you can change it. To set the password: [Session 1].Change Menu Password Session 2.Change Menu Password String, minimum length = 1, maximum length = 10 [3193693] To enable the password, see “Main Menu password.” S COM Select (248X, 5055 DOS, 5055 .NET) [Session 1].Com Select Session 2.Com Select [COM 1] COM 2 S Main Menu Password You must enable and set the password to access the Main Menu. To enable or disable the password: [Session 1].Menu Password Session 2.Menu Password Enabled [Disabled] To set the password, see “Change menu password.” S Print Device (6400, 5020, 5055 .NET, CK30, CV60) [Session 1].Print Device Session 2.Print Device [RS232 Print] IRDA Print (6400, 700 Series) RF Print (5020, 5055 .NET, 700 Series) Pan Print (700 Series, for Bluetooth Printing) S Printer Address (5020, 5055 .NET, 700 Series, CK30, CV60) [Session 1].Printer Address Session 2.Printer Address String, minimum length=0, maximum length=16 [null string] S Printer Port (5020, 5055 .NET, 700 Series, CK30, CV60) [Session 1].Printer Port Session 2.Printer Port Numeric, minimum = 0, maximum = 65535 [23]

212

TE 2000 VT/ANSI Terminal Emulation Programmer’s Guide

Page 237

Chapter 5, Customizing Your Configuration

LCD Options S Annunciator Format [Session 1].Annun Format Session 2.Annun Format [Vertical] 2455, 2475, 248X, 5020, 5055 DOS, 5055 .NET, 59XX, 700 Series, CK30 [Horizontal] 2415, 2425, 2435A, 6400, 5055 .NET, CV60 S Annunciator Position [Session 1].Annun Position Session 2.Annun Position Upper Right Upper Left [Lower Right] 6400, 5020, 5055 DOS, 59XX, 17XX, 11XX, 700 Series, CK30 Lower Left [Stealth] 2415, 2425, 2435A, 2455, 2475, 248X, 5055 .NET, CV60 S Backlight Intensity (59XX) [Session 1].BLight Intensity Session 2.BLight Intensity Numeric, minimum = 0, maximum = 15 S Define Height (Scroll Window) [Session 1].Define Height Session 2.Define Height Numeric, minimum = 1, maximum = 24 [8] S Define Width (Scroll Window) [Session 1].Define Width Session 2.Define Width Numeric, minimum = 1, maximum = 80 [8] S Key Uppercase [Session 1].Key Uppercase Session 2.Key Uppercase [Enabled] Disabled S LCD Contrast (59XX, 17XX) [Session 1].LCD Contrast Session 2.LCD Contrast Numeric, minimum = [0], maximum = 255 S Screen Columns [Session 1].Screen Cols Session 2.Screen Cols Numeric, minimum = 1, maximum = 255 [16] 11XX [17] 17XX [19] 2435A [20] 2415, 2425, 2455, 2475, 248X [40] 59XX [80] 5055 DOS, 5055 .NET, CV60 [16] 6400 wide display, 5020, 700 Series, CK30 TE 2000 VT/ANSI Terminal Emulation Programmer’s Guide

213

Page 238

Chapter 5, Customizing Your Configuration

S Screen Mode [Session 1].Screen Mode Session 2.Screen Mode Center Cursor [Corner Mode] Page Mode Lazy Mode Locked Mode S Screen Rows [Session 1].Screen Rows Session 2.Screen Rows Numeric, minimum = 1, maximum = 255 [8] 11XX [8] 17XX [10] 5020, 59XX, 700 Series, CK30 [16] 2415, 2425, 2435A, 2455, 2475, 248X [25] 5055 DOS, 5055 .NET, CV60 [16] 6400 wide display S Scroll Window [Session 1].Scroll Window Session 2.Scroll Window Screen Size Scroll Setting [Tab Size] S XOrigin [Session 1].XOrigin [Session 2].XOrigin Numeric minimum = 0, maximum = 79 [0] S YOrigin [Session 1].YOrigin [Session 2].YOrigin Numeric minimum = 0, maximum = 23 [0]

Beeper Setup Options Note: Beeper setup options do not apply to the 2415, 2425, 2435A, 2455, 2475, 248X, 5020, 5055 .NET, 700 Series, CK30, and CV60 terminals. S Beep Head Set (17XX) [Session 1].Beep Head Set Session 2.Beep Head Set Enabled [Disabled] S Beep Internal (not supported on 59XX) [Session 1].Beep Internal Session 2.Beep Internal [Enabled] Disabled

214

TE 2000 VT/ANSI Terminal Emulation Programmer’s Guide

Page 239

Chapter 5, Customizing Your Configuration

S Beeper (Error Tone) Frequency (not supported on 59XX) [Session 1].Beep Frequency Session 2.Beep Frequency Numeric, minimum = 0, maximum = 30 [13] 11XX and 17XX [6] 6400 S Beeper (Error Tone) Length [Session 1].Beep Length Session 2.Beep Length Numeric, minimum= 1 , maximum= 10 [3] S Beeper (Error Tone) Volume (59XX) [Session 1].Beep Volume Session 2.Beep Volume Numeric, minimum = 0, maximum = 255 [95] S Key Click Frequency (not supported on 59XX) [Session 1].KeyClick Freq Session 2.KeyClick Freq Numeric, minimum = 0, maximum = 30 [13] 17XX and 11XX [6] 6400 S Key Click Length [Session 1].KeyClick Length Session 2.KeyClick Length Numeric, minimum = 1, maximum = 10 [1] 59XX, 17XX, and 11XX [6] 6400 and 5055 DOS S Key Click Volume (59XX) [Session 1].KeyClick Volume Session 2.KeyClick Volume Numeric, minimum = 0, maximum = 255 [95]

More (Main Menu 2) Option S Foreground Session Foreground Sess [Session 1] Session 2 (2415, 2425, 2435A, 2455, 2475, 248X with WTP protocol stack, 6400, 5020, 5055 DOS, 5055 .NET, 59XX, 17XX, 11XX, 700 Series, CK30, CV60) S Set Hot Key (2415, 2425, 2435A, 2455, 2475, 248X with WTP protocol stack,6400, 5020, 5055 DOS, 5055 .NET, 59XX, 17XX, 11XX, 700 Series, CK30, CV60) [Session 1].Set Hot Key Session 2.Set Hot Key F1 through F24 [Disabled] TE 2000 VT/ANSI Terminal Emulation Programmer’s Guide

215

Page 240

Chapter 5, Customizing Your Configuration

S Type-Ahead [Session 1].Type-Ahead Session 2.Type-Ahead [Enabled] Disabled

Additional Parameters These parameters do not have equivalent TE configuration menu options. S Alternate Screen Columns (6400, 5055 DOS, 17XX) [Session 1].Alt Screen Cols Session 2.Alt Screen Cols Numeric, minimum = 1, maximum = 255 [17] 17XX [40] 5055 DOS [16] 6400 S Alternate Screen Rows (6400, 5055 DOS, 17XX) [Session 1].Alt Screen Rows Session 2.Alt Screen Rows Numeric, minimum = 1, maximum = 255 [8] 17XX [12] 5055 DOS [16] 6400 wide display S Double Byte Character Set (DBCS) Code (59XX) [Session 1].DBCS Code Session 2.DBCS Code Numeric, minimum = 0, maximum = 16 [0] S Key Repeat (59XX) [Session 1].Key Repeat Session 2.Key Repeat Enabled [Disabled] S Program Name (appears on initialization and version screens) Program Name String, minimum length = 8, maximum length = 8 [FWP???H?] S Program Version (appears on initialization and version screens) Program Version String, minimum length = 4, maximum length = 4 [?.??] S Return Result (this is a test feature for VT/ANSI emulation; if disabled, extended commands (for #K only) will not return a result to the host application) Return Result [Enabled] Disabled S Set-Up Parms Menu Password [Session 1].Password Session 2.Password String, minimum length = 1, maximum length = 10 [CR52401]

216

TE 2000 VT/ANSI Terminal Emulation Programmer’s Guide

Page 241

Chapter 5, Customizing Your Configuration

Changing Text Modify CFGLIT.DAT to change the text of TE configuration menus, configuration parameters, or system messages. This file contains the strings that appear in the configuration menus, parameter set-up files, and system messages. An identification (ID) number identifies each literal string. To create your own literal file, you create a text file that associates these numbers with the actual literal strings. You then use MAKELIT.EXE to convert the text file to a format the configuration program can use. Each line in the literal text file begins with the literal ID number. After the ID number, you type the quoted string that is used when that ID number is referenced. If you omit an ID number, its string appears as “Bad Literal File” when you run the program in the terminal. Literal ID numbers are available upon request from Intermec. Contact your Intermec representative for more information about ID numbers. You can create a sample file containing the default literal strings using MAKELIT.EXE to “reverse engineer” the standard CFGLIT.DAT file. To do this, type the following command line to unpack CFGLIT.DAT into a CFGLIT.TXT text file: makelit -r cfglit.dat cfglit.txt

The CFGLIT.TXT file this command creates contains all the default strings the configuration program uses. One line in CFGLIT.TXT looks like this: 0x2f10 “RS232 PORT\nIN USE\n\nPLEASE WAIT!”

“0x2f10” is the literal ID number for the RS-232 port-in-use message that appears when a personal computer sends an RS-232 command to the TE program. The message text follows the ID number in a quoted string. The embedded “\n” sequence within the quoted string indicates a “new line” character and outputs a carriage return/line feed. To change the text of the message that appears, change the quoted string. For example, change the above line to look like this: 0x2f10 “Printing\nPlease Wait!”

When you have a text file with one line for every ID number, use MAKELIT.EXE to convert the file to an indexed literal file. If your text file is named CFGLIT.TXT, you would type the following command which creates the new literal CFGLIT.DAT file. For instructions on how to download the file, see “Downloading Files” on page 228. makelit cfglit.txt cfglit.dat

TE 2000 VT/ANSI Terminal Emulation Programmer’s Guide

217