The text of a manual · part 17 of 47
TE 2000 VT/ANSI Terminal Emulation Programmer's Guide: Chapter 4: Using the Terminal Emulation Menus, pages 141 to 150
Pages 141 to 150 of 416, from TE 2000 VT/ANSI Terminal Emulation Programmer's Guide
The original document is the PDF (3.6 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 2435
Page 141
Chapter 4, Using the Terminal Emulation Menus
2) Barcode Parms (2415, 2425, 2435A, 2455, 2475, 248X, 5020) The 2) Barcode Parms (parameters) menus designate whether you are using a bar code scanner and scan options. Barcode Parms 1) Code 39 Encoded 2) 3) Concatenate 4) RS232 Stream 5) Stream Scan 6) Scan All Flds
4) RS232 Stream is blank for 5020
1) Code 39 Encoded By default, 1) Code39 Encoded is disabled. When you enable this option, the key press sequences for Encoded Code 39 are used. For more information, see Appendix A, “Bar Code Scanning.”
3) Concatenate Each bar code read is added to the end of the previous bar code read until the 2415, 2425, 2435A, 2455, 2475, 248X, or 5020 terminal meets a condition forcing transmission to the host. When this option is OFF, each bar code read is placed at the beginning of the current input field. After a bar code is placed in a field, any subsequent read replaces the first read. Note: If you access the TE configuration menus when 4) RS232 Stream is enabled, all RS-232 data received during this time is lost. Only the data arriving from the COM1 port on the hand-held terminal is received.
4) RS232 Stream (blank for 5020) If this option is enabled, the terminal watches the RS-232 port for activity in which the terminal reads in the RS-232 data and sends it to the host. This enables support for fixed-station scanners or scales that send only RS-232 data without having the host send an extended command to enable the RS-232 port. Default for 4) RS232 Stream is disabled. For information about setting scanner options when this is enabled, see Chapter 2, “Using Terminal Emulation Applications.”
5) Stream Scan If the scanned bar code is too big for the input field, the overflow information appears in the next field and continues until the entire bar code is entered. When this option is OFF, and the scanned bar code is too big for the input field, the overflow information is dropped.
6) Scan All Flds (Fields) When this option is selected, the scanner is enabled when the cursor is in an input field. When this option is OFF, the host computer must enable the scanner for each input field that requires scanned data. TE 2000 VT/ANSI Terminal Emulation Programmer’s Guide
117
Page 142
Chapter 4, Using the Terminal Emulation Menus
2) Barcode Parms (6400, 5055 DOS, 5055 .NET, 59XX, 17XX, 11XX, 700 Series, CK30, CV60) Selecting 2) Barcode Parms displays either the Scanner Type menu or the Scan Options menu, pending on your terminal: S For the 6400, 5055 DOS, 59XX, 17XX, 11XX terminals, Selecting 2) Barcode Parms displays the Scanner Type menu. S For the 5055 .NET, 700 Series, CK30, CV60 terminals, Selecting 2) Barcode Parms displays the Scan Options menu.
Scanner Type (6400, 5055 DOS, 5055 .NET, 59XX, 17XX, 11XX) Use the Scanner Type menu to designate the type of bar code scanner. To make a selection, press the numeric key corresponding to the desired option, then press [Enter] to access the Scan Options menu. Note: If 1) No Scanner is chosen, you can set the remaining scanner and bar code options. Then, if a scanner is used at a later time, you only designate the scanner type. Selected options are highlighted on the display. Press a key corresponding to that option to deselect a selected option. Scanner Type 1) No Scanner 2) Wand 3) Laser 4) Wand Emulate 5) Auto Detect
2) Wand, 4) Wand Emulate, and 5) Auto Detect are for 59XX, 17XX, 11XX
Scan Options Use the Scan Options menu to assign scan options, enable bar code symbologies to use (the terminal can only decode the enabled symbologies), and set options for each enabled bar code symbology, such as the bar code lengths. Press [Enter] to advance to other Scan Options menus. Scan Options 1) Redundancy 2) MOD 10 Check 3) Concatenate 4) BC Type Char 5) Stream Scan 6) Scan All Flds 7) More
1) Redundancy is for 6400, 59XX, 17XX, 11XX 3) Concatenate is for 6400, 5055 DOS, 5055 .NET, 700 Series, CK30, CV60 4) BC Type Char is for 6400, 5055 .NET, 59XX, 17XX, 11XX, 700 Series, CK30, CV60
S 1) Redundancy (6400, 59XX, 17XX, 11XX) This option requires two identical scans of a bar code, one right after another, before the terminal accepts the scan as valid.
118
TE 2000 VT/ANSI Terminal Emulation Programmer’s Guide
Page 143
Chapter 4, Using the Terminal Emulation Menus
S 2) Mod 10 Check When you select this option, a check digit is added at the end of the bar code after a good read for transmission to the host. The host can then validate the transmitted data using the check. This feature is not needed with modem transmission protocols. The bar code number is divided by 10, until the number (or modulus) is less than 10. If the modulus subtracted from 10 (remainder) is equal to zero, then the bar code number is valid. S 3) Concatenate (6400, 5055 DOS, 5055 .NET, 700 Series, CK30, CV60) Each bar code read is added to the end of the previous bar code read until the 6400, 5055 DOS, 5055 .NET, 700 Series, CK30, or CV60 terminal meets a condition forcing transmission to the host. When this option is OFF, each bar code read is placed at the beginning of the current input field. After a bar code is placed in a field, any subsequent read replaces the first read. S 4) BC Type Char (6400, 5055 .NET, 59XX, 17XX, 11XX, 700 Series, CK30, CV60) This option adds a character associated with the bar code type at the beginning of the scanned bar code. See page 348 for bar code type characters. S 5) Stream Scan If the scanned bar code is too big for the input field, the overflow information appears in the next field and continues until the entire bar code is entered. When this option is OFF, and the scanned bar code is too big for the input field, the overflow information is dropped. S 6) Scan All Flds (Fields) When this option is selected, the scanner is enabled when the cursor is in an input field. When this option is OFF, the host computer must enable the scanner for each input field that requires scanned data. S 7) More This brings you additional scanning options that adjust scanning timeout and characters sent before and after the scanned data. S 1) Scan Timeout (59XX, 17XX, 11XX) Use this option to adjust the scanning timeout period from 1 to 200 seconds. When using a proximity-detect scanner, you can shorten the timeout period to speed up scanning while also reducing the duration of errant scans. With a long-range scanner, you may want to increase the timeout period to ensure sufficient aiming time. Scan Timeout Seconds XXX
TE 2000 VT/ANSI Terminal Emulation Programmer’s Guide
119
Page 144
Chapter 4, Using the Terminal Emulation Menus
S 2) Scan PreChar and 3) Scan PostChar Enter a hexadecimal value from 00–FF for the character to be sent preceding the scanned data or after the scanned data. The value of 20h means that pre- or post-characters are not sent. Scan Options 1) Scan Timeout 2) Scan PreChar 3) Scan PostChar
1) Scan Timeout is for 59XX, 17XX, 11XX
Scan Options to Enable Bar Codes There are menus of options to enable (or disable) various bar code symbologies. To enable a bar code, press the numeric key corresponding to the number of the bar code symbology (shown on menu), then press [Enter]. After enabling a particular bar code, options may have to be selected for the bar code. After selecting the desired options, set the length requirements (such as minimum and maximum length, fixed lengths, leading and trailing character options, etc.). Once the length requirements are set, the terminal returns to the same Scan Options menu. Choose another bar code symbology from that menu or press [Enter] to advance to the next Scan Options menu. Scan Options 1) UPC 2) EAN 3) Code 39 4) Code 128 5) Codabar
4) Sys 1 UPCE is for 6400, 17XX, 11XX, 700 Series, CK30, CV60
3) Extended is blank for 700 Series, CK30, CV60 6) Relax Std is for 59XX, 17XX, 11XX
UPC 1) Enabled 2) Add-On 2 3) Add-On 5 4) Sys 1 UPCE 5) Sys 0 UPCE 6) Expand E To A
Code 39 1) Enabled 2) Chk Digit 3) Extended 4) Encoded 5) Auto-Encoded 6) Relax Std 7) Full ASCII
[1]
[3]
[2]
[4]
EAN 1) Enabled 2) Add-On 2 3) Add-On 5 4) Expand 8 To 13
2) Add-On 2 and 3) Add-On 5 if using 700 Series, CK30, or CV60, see the note on the top of the next page.
Code 128 1) Enabled 2) UCC/EAN 3) No UCC Type 4) UCC F1 Value
[6] RELAX CODE 39 1) Quiet zone 2) Data Decode 3) Element Decode 4) START Decode
120
[5]
Codabar 1) Codabar 2) ABC Codabar
2) ABC Codabar is for 59XX, 17XX, 11XX
TE 2000 VT/ANSI Terminal Emulation Programmer’s Guide
Page 145
Chapter 4, Using the Terminal Emulation Menus
Note: For the 700 Series Computer, the CK30 Handheld Computer, or the CV60 Data Collection PC, this implementation of TE 2000 will process EAN 8 and UPC E bar codes in the same manner. The type character for EAN 8 with Add-On 2 or Add-On 5 will decode as UPC E with Add-On 2 or Add-On 5, respectively. The bar code type character will also indicate UPC E with Add-On 2 or Add-On 5, respectively. Consequently, the drop leading and trailing UPC options will be used when an EAN 8 with Add-On 2 or Add-On 5 is decoded.
Scan Options 2 (Additional Bar Codes) This menu offers additional bar code selections. After enabling a bar code symbology, various options, including length can be set. When all options are set, the display returns to the Scan Options 2 menu. This menu and the bar code symbologies to be enabled are shown below. When all needed bar code symbologies are enabled, press [Enter] to return to the Scan Options menu. Press [Enter] again to back out and return to the 1) Set-up Parms menu.
5) Code 11 is for 59XX, 17XX, 11XX, 700 Series, CK30, CV60
3) MOD11 Chk is blank for 700 Series, CK30, CV60 4) Allow Alpha is for 59XX, 17XX, 11XX
Scan Options 2 1) Plessey 2) Str 2of5 3) Int 2of5 4) CI 2of5 5) Code 11 6) Code 93
Plessey 1) Enabled 2) MOD10 Chk 3) MOD11 Chk 4) Allow Alpha
Int 2of5 1) Enabled 2) Chk Digit
Code 11 1) Enabled 2) Chk Dig 1 3) Chk Dig 2
TE 2000 VT/ANSI Terminal Emulation Programmer’s Guide
[1]
[3]
[5]
[2]
Str 2of5 1) Enabled 2) Disabled
[4]
CI 2of5 1) Enabled 2) Disabled
[6]
Code 93 1) Enabled 2) Disabled
121
Page 146
Chapter 4, Using the Terminal Emulation Menus
Lengths Options The Lengths Options menus determine the maximum and minimum length for a specific bar code symbology. Setting the length of enabled bar codes helps the terminal determine if a scanned bar code is valid and improves response time. The length options must be set for each enabled bar code. Enter this information in the order listed. 1 Key in the maximum length (0–99), then press [Enter]. For the 700 Series Computer, the CK30 Handheld Computer, or the CV60 Data Collection PC, set this as high as you intend to set the minimum length. 2 Key in the minimum length (0–99), then press [Enter]. 3 Fixed-length entries override the maximum and minimum length entries (minimum and maximum are used for chosen codes). If fixed lengths are not needed for the enabled bar code, enter zero (0). Enter the fixed length (0–99), then press [Enter]. Up to four prompts to set another fixed length will appear. Enter zero (0) for the unused fixed lengths. Note that I 2 of 5 only supports fixed lengths 1 and 2. Entries in 3 and 4 are ignored. 4 Enter the number of characters (0–15) to drop from the front (leading) edge of the scanned bar code, then press [Enter]. 5 Enter the number of characters (0–15) to drop from the rear (trailing) edge of the scanned bar code, then press [Enter]. 700 Series, CK30, CV60 Exceptions The following exceptions apply only to the 700 Series Computer, the CK30 Handheld Computer, or the CV60 Data Collection PC: S Codabar, Str 2of5, Int 2of5, and CI 2of5 bar code symbologies set the length, if fixed-length 1 is non-zero, to three fixed-length entries equal to the first three fixed-lengths (fourth fixed-length is ignored). Otherwise, the length is set to greater than or equal to the minimum length. S Code 39, Code 128, Code 93, and Plessey set the length to any length greater than or equal to the minimum length. S UPC/EAN and Code 11 lengths are not used, ANY is allowed. S Codabar options will not decode less than two data characters (four characters including Start and Stop). S CI 2of5 options override Str 2of5 options, if both CI 2of5 and Str 2of5 are selected. S EAN Add-on settings override UPC add-on settings, if both UPC and EAN options are selected. S If “Sys 1 UPCE” or “Sys 0 UPCE” is selected, then both UPCE number system 0 and 1 are enabled. S Code 11 does not support “No check digits.” Select either 1 check digit (Chk Dig 1) or 2 check digits (Chk Dig 2) according to your bar codes. If neither check digit option is selected, then 2 check digits will be used as a default.
122
TE 2000 VT/ANSI Terminal Emulation Programmer’s Guide
Page 147
Chapter 4, Using the Terminal Emulation Menus
After all of the length options are set for the enabled bar code, the display returns to either the Scan Options menu or the Scan Options 2 menu (pending on from which menu the bar code was enabled).
(bar code type) Max Length xx
(bar code type) Max Length xx Min Length xx Fix Length 1 xx Fix Length 2 xx Fix Length 3 xx
(bar code type) Max Length xx Min Length xx
(bar code type) Max Length xx Min Length xx Fix Length 1 xx Fix Length 2 xx Fix Length 3 xx Fix Length 4 xx
(bar code type) Max Length xx Min Length xx Fix Length 1 xx
(bar code type) Drop Leading xx
(bar code type) Max Length xx Min Length xx Fix Length 1 xx Fix Length 2 xx
(bar code type) Drop Leading xx Drop Trailing xx
3) Protocol Opts Use the 3) Protocol Opts menu to designate the type of terminal emulation the host supports. You can also use it to designate additional commands and command sets. Protocol Opts 1) Host View Sze 2) Data Stream 3) Extended Cmds 4) 5250 5) 3270 6) VT/ANSI 7) Native
TE 2000 VT/ANSI Terminal Emulation Programmer’s Guide
7) Native is blank if UDP Plus or TCP/IP
123
Page 148
Chapter 4, Using the Terminal Emulation Menus
1) Host View Sze The 1) Host View Sze option tells the terminal the format of display information sent from the host. The display viewing size equals 1920 (the number of rows times the number of columns). The exception is with 5250 Terminal Emulation which has an additional row for error messages and therefore has 2000 characters. The default setting for Native Terminal Emulation is 120 columns by 16 rows (equals 1920). The default for VT/ANSI Terminal Emulation is 80 columns by 24 rows (equals 1920). The default for 5250 Terminal Emulation is 80 columns by 24 rows (25 with error messages). The default for 3270 Terminal Emulation depends on what the original setting was before changing to the 3270 Terminal Emulation. Remember that the total characters must equal 1920 (number of rows by the number of columns) unless using 5250 Terminal Emulation with error messages. Enter a number between 1–80 to change the width. Press [Enter] to return to the 3) Protocol Opts menu. “xx” is the width.
Host View Sze Width xx
2) Data Stream Enter the number corresponding to the type of host computer to specify the data stream used. Press [Enter] to return to the 3) Protocol Opts menu. Data Stream 1) Native 2) 3270 3) 5250 4) VT/ANSI
1) Native is blank if UDP Plus or TCP/IP
Note: For 2415, 2425, 2435A, 2455, 2475, 248X, 5020, 5055 .NET, 700 Series, CK30, and CV60 terminals, you can also set the emulation type through the 1) ITC Server or 3) Direct Connect options.
124
TE 2000 VT/ANSI Terminal Emulation Programmer’s Guide
Page 149
Chapter 4, Using the Terminal Emulation Menus
For information about 3270, 5250, or Native TE, see these manuals: S TE 2000 3270 Terminal Emulation Programmer’s Guide (P/N 977-055-003) S TE 2000 5250 Terminal Emulation Programmer’s Guide (P/N 977-055-004) S Native Terminal Emulation Programmer’s Guide (P/N: 977-055-006)
3) Extended Cmds (Commands) Use 3) Extended Cmds to enable or disable extended commands. By default, extended commands are disabled. For more information about extended commands, see Chapter 7, “Extended Commands.” When this option is enabled, the host computer can change or use RS-232 communications (such as printers), bar code options, display screen and font size, and error tone features of the unit. Press [1] to enable or press [2] to disable the extended command list. Press [Enter] to return to the 3) Protocol Opts menu. Extended Cmds 1) Enabled 2) Disabled
4) 5250 (Options) The 4) 5250 menu enables the following features if the 5250 communication protocol is used. Press the appropriate number to enable an option, then press [Enter] to return to the 3) Protocol Opts menu. S 1) Beep On Error Causes the buzzer to emit when an error condition occurs; does not lock up the keyboard. S 2) Auto Tab Scan Causes the cursor to automatically tab forward to the next input field when a good scan is obtained. S 3) Telnet (blank for 5020, 5055 .NET, 700 Series, CK30, CV60) Handles the telnet option negotiations to establish a session with an appropriate telnet server. Note: 3) Telnet is not changeable if TCP/IP is used.
TE 2000 VT/ANSI Terminal Emulation Programmer’s Guide
125
Page 150
Chapter 4, Using the Terminal Emulation Menus
S 4) Device Name Enters a physical name for the device. This name is 1–10 characters with allowable values of A–Z, a–z, 0–9, and #, $, -, and @. 5250E RFC 1572 Support. Note: The first character of 4) Device Name cannot start with a number (0–9). The following screen displays after a physical name is entered. S 1) 5250 Allow Alias If this is enabled, and your current device name returns an error in use, then the terminal attempts to appeand a “$” (dollar sign) to the end of your device name to initiate a session to your host. When disabled, the device name is resent to the host for the host to send a FIN packet to the terminal, causing the terminal to reboot. This continues until the device name is no longer in use. Allow Alias 1) 5250 Allow Alias
S 5) Allow NAWS (Negotiate About Window Size) When enabled, the terminal will support Telnet option 31 if prompted. When disabled, this option will return a “won’t do” message. S 6) Skip FldExit (Field Exit) When this option is enabled, a field that would generate an error code of “0020” (field exit required) when [Enter] was pressed will now send the field data. The legacy TE application would send the entire field so a “7” entered into a 3-character blank-filled field would transmit as “7bb”, a “12” would transmit as “12b”. TE2000 strips the field fill characters so “7” will transmit as a “7”, “12” will transmit as a “12” and so forth. Note A “b” indicates a one-byte space. S 7) More Select 7) More to modify the function of the period key or backspace key. S 1) Period–Comma (2415, 2425, 2435A, 2455, 2475, 248X) Select 1) Period–Comma to change the period key ( . ) to a comma.
126
TE 2000 VT/ANSI Terminal Emulation Programmer’s Guide