For the Intermec 2435

Page 21

1

Getting Started

This chapter introduces the Native terminal emulation application.

Native Terminal Emulation Programmer’s Guide

1

Page 22

Chapter 1, Getting Started

Understanding Network Protocol Options Native Terminal Emulation applications for the Enterprise Wireless LANt system use one of the following network protocol options: S UDP Plus The terminal communicates with the host computer through the INTERMECR Data Collection Server (DCS) 300 and an access point. S TCP/IP The terminal communicates through an INTERMEC access point, which is directly connected to the host computer on an Ethernet or a token ring network. S WTP The terminal communicates with the host computer through the DCS 300, INTERMEC access point, or other INTERMEC gateways. For network configuration options, refer to your terminal’s user manual.

Setting Up the Terminal and the Network Before you can start using the Native Terminal Emulation application on your terminal, you need to do the following: 1 Set up your terminal. Set-up includes charging and installing the battery pack and turning on the terminal for the first time. For instructions, refer to your terminal’s user manual. Note: Battery packs do not apply to all terminals. Vehicle mount and stationary terminals are powered via an external source. 2 Configure your terminal and the network. To use RF communications on the terminal, you need to: a Configure the DCS 300 (UDP Plus or WTP), other INTERMEC gateway (WTP), or host (TCP/IP). b Configure the access point. This does not apply to the 2480/2481 Terminal, which contains an Ethernet NIC instead of a radio. c Configure the network parameters on the terminal. For instructions, refer to your terminal’s user manual. 3 Verify that your terminal is communicating correctly with the access point, gateway, or host. To verify that your terminal is communicating correctly, refer to the terminal’s user manual for instructions.

2

Native Terminal Emulation Programmer’s Guide

Page 23

Chapter 1, Getting Started

Starting the Native Terminal Emulation Application You are ready to start your application once the terminal has been set up, the terminal and the network have been configured, and communications have been established with the gateway and access point or host. To start your application: Turn on the terminal. Wait a few seconds while the initialization screens (below) clear and the application starts.

COPR. 1991-2003 INTERMEC. ALL RIGHTS RESERVED V<version number> <release date>

TE 2000(TM)

<program name> <version> Host: <host name> <emulation type>

Note: If your application does not start after a few seconds, you may not have configured the terminal correctly. For help, refer to your terminal’s user manual. You can now do one of the following: S Become familiar with Native TE if you have not previously used it. S Perform a quick configuration. S Configure your Native TE application. S Customize your Native TE application.

Becoming Familiar With Native Terminal Emulation If you have not previously used Native TE, see Chapter 3, “Using the Terminal’s Keyboard,” to become familiar with your terminal’s keyboard and the keys you need to press to perform Native commands. See Chapter 6, “Terminal Commands,” to understand Native commands.

Native Terminal Emulation Programmer’s Guide

3

Page 24

Chapter 1, Getting Started

Performing a Quick Configuration Note: For Terminal Emulation Version 6.60 or greater, the default data stream is “VT/ANSI.” 1 Change the data stream to Native. The default data stream is “Native” for the 6400 (WTP), 5055 (WTP), 11XX, 17XX, and 59XX Terminals. The default data stream for 2415, 2425, 2435A, 2455, 2475, 248X, and IP terminals is “3270.” a Access the terminal emulation configuration menus by pressing the following keys, then choose 1) Set-up Parms from the Main Menu. Terminal

Key Sequence

2415

) ! (55-key keyboard) ( 5 (37-key keyboard)

2425

(!

2435A r l (57-key keyboard) [Green] > [Orange] > (48-key keyboard) r l (39-key function numeric keyboard)

2455, 2475, 248X

(¡

6400

[Gold] [Blue]

5055

[Blue] [M] or [ALT] [M]

59XX

[Brown] [Space]

17XX, 11XX

[Gold] [Black]

Note: Press a number to select a menu option, then press [Enter] to return to a previous menu. b At the Enter Password prompt, enter cr52401. On 17XX (37-key) Terminals, the password is: F12 F11 5 2 4 0 1 c From the Set-up Parms menu, select 3) Protocol Opts, 2) Data Stream, then 7) Native. 2 From the Main Menu, select 7) More, then 2) Save Parms. 3 At the Enter Password prompt, type cr52401, then press enter. On 17XX (37-key) Terminals, the password is: F12 F11 5 2 4 0 1 4 From the Main Menu, select 6) Exit Menus. Note: For WTP devices, you should also set a terminal number. 5 Log in to a TE session, then use the terminal to collect/transmit data.

4

Native Terminal Emulation Programmer’s Guide

Page 25

Chapter 1, Getting Started

Configuring the Native Application You can use the terminal’s TE configuration menus to configure site-specific operational parameters, including UDP Plus, WTP, or TCP/IP communications, terminal emulation options, and the Main Menu password. For information about configuring the terminal, see Chapter 3, “Using the Terminal Emulation Menus.”

Using Advanced Features You can customize the standard Native TE program to do the following: For more information, see Chapter 4, “Customizing Your Configuration.” S Use the auto-login feature to send the same login information each time you login to the host. S Create a custom parameter set-up file. S Change the text of TE configuration menus or system messages. S Preinitialize the Native TE program

Unsupported Commands and Functions Native TE for the 2415, 2425, 2435A, 2455, 2475, and 248X Terminals does not support the following commands and functions, which were supported in previous versions. S End (viewport) Moved the window/viewport to the end of the last line displayed on the TE screen. S Erase Field Erased all characters in the field where the cursor was positioned. S Erase Last Word Erased all characters from the cursor back to the start of a word or a space on the screen. S Fast Cursor Right or Left Moved the cursor two positions to the right or left rather than one. S Home (viewport) Moved the window or viewport to the top left corner of the TE screen. S Reshow Resent a screen image from the locally maintained host buffer to refresh the terminal screen. S Status Toggled the terminal’s screen between the status line display and the normal field input display. S Status line messages Reported the operating status of the terminal and host system.

Native Terminal Emulation Programmer’s Guide

5

Page 26

Chapter 1, Getting Started

S Dual sessions Not supported in Trakker Antares UDP Plus or TCP terminals. If you scan the bar code for an unsupported command, the bar code data is read into the terminal. If you press the key sequence for the command, the sequence is ignored.

Program Names The following chart lists TE options and program names. Note: Native TE does not support SST (Spread Spectrum Transmission) or regular UHF. “S-UHF” is synthesized UHF. Model

Option

2415, 2425, 2435A, 2455, 2475, 248X

TE/WTP/2.4 GHz OpenAir TE/WTP/802.11 TE/UDP Plus/2.4 GHz OpenAir TE/UDP Plus/802.11 TE/IP/2.4 GHz OpenAir TE/IP/802.11

6400

TE/WTP/2.4 GHz OpenAir TE/WTP/802.11 TE/WTP/900 MHz Falcon TE/IP/2.4 GHz OpenAir TE/IP/802.11

5055

TE/WTP/2.4 GHz OpenAir TE/WTP/802.11 TE/IP/2.4 GHz OpenAir TE/IP/802.11

FWP650H0 FWP650H0 FWP65TH0 FWP65TH0

59XX

TE/WTP TE/WTP TE/WTP/2.4 GHz OpenAir TE/WTP/900 MHz Falcon TE/WTP/S-UHF

FWP592H0 FWP594H0 FWP598H0 FWP596H0 FWP591H1

17XX

TE/WTP TE/WTP TE/WTP/2.4 GHz OpenAir TE/WTP/900 MHz Falcon TE/WTP/S-UHF

11XX

TE/WTP TE/WTP TE/WTP/2.4 GHz OpenAir TE/WTP/900 MHz Falcon TE/WTP/S-UHF

6

Program Name FWP240H0

51-key keyboard FWP640H0 FWP640H0 FWP640H0 FWP64TH0 FWP64TH0

57-key keyboard FWP170H0 FWP174H0 FWP178H0 FWP176H0 FWP171H0

41-key keyboard FWP640H4 FWP640H4 FWP640H4 FWP64TH4 FWP64TH4

37-key keyboard FWP170H3 FWP174H3 FWP178H3 FWP176H3 FWP171H3

FWP110H0 FWP114H0 FWP118H0 FWP116H0 FWP111H0

Native Terminal Emulation Programmer’s Guide