Page 207
6
Terminal Commands
This chapter describes each terminal command with detailed information.
Native Terminal Emulation Programmer’s Guide
187
Page 208
Chapter 6, Terminal Commands
G (Reset Terminal) The G command returns the terminal to its first “state,” a known condition. All terminals reset when variable t (terminal number) is omitted. Terminals respond to a poll with their power-up message. In the command, the range of t is 000–126. If the data collection server or gateway is configured for three-byte addressing, t is three digits. For onebyte addressing used by some Intermec legacy systems, t is a character from 0–9 or A–F.
Command Gt<cr> (reset specific terminal) G<cr> (reset all terminals)
DCS or Gateway Response OK<cr>
R Response tP,x<cr>
R Response Variables S t
Terminal number (000–126)
S P
Terminal has reset or powered-up
S x
Terminal power-up type (See the “Terminal Power-Up Types” table on page 177.)
Example Command: G002<cr> Action: Data collection server or gateway resets terminal 002. R Response: 002P,032<cr>
188
Native Terminal Emulation Programmer’s Guide
Page 209
Chapter 6, Terminal Commands
StD/ (Set Terminal Parameters) Note: This is for 6400, 5055, 59XX, 17XX, 11XX Terminals only. StD/ sets terminal operating control parameters once, when you power up the terminal.
Command StDo/c<cr>
DCS or Gateway Response OK<cr>
R Response tC0<cr>
Command and R Response Variables S t
Terminal number (000–126)
S o
Option (see the “StD/ Options” table below)
S c
Bar code parameter (default: UPC/EAN). Lengths default to a maximum of 31 and a minimum of 1 (see the “StD/ Bar Code Parameters” table below).
StD/ Options o
Description
Default
B
Disable key-pressed buzzer
Enabled
Dx Duration of buzzer for Write Display command and input errors. x=0-9 in 30 ms increments.
120 msec (x=4)
Fx x=character that appears for the [FUNC] key (\ not allowed)
<space>
Sx x=character that appears for the [SKIP] key <space> (\ not allowed)
<space>
Tx
Gross time-out duration (x=0-255 sec)
30 sec
Native Terminal Emulation Programmer’s Guide
189
Page 210
Chapter 6, Terminal Commands
StD/ Bar Code Parameters Byte Position Description
Bit Position
1
Bar code block number (reserved).
01000000
2
Bit 4=Enable scanner Bit 3=CCD select Bit 2=Wand select Bit 1=CCD redundancy bit Bit 0=Laser scanner redundancy bit
001XXXXX
3
Bit 4=Disable bar code type character Bit 3=Unused Bit 2=Unused Bit 1=Must be 0 Bit 0=Enable MOD 10 check digit
001X00XX
4
Maximum bar code length. Bits 0-4=Length
010XXXXX
5
Minimum bar code length. Bits 0-4=Length
010XXXXX
6
Bit 4=Decode UPC Bit 3=Decode UPC with add-ons Bit 2=Expand UPC E to UPCA Bit 1=Enable UPC E type 1 only
001XXXX0
7
Bit 4=Decode EAN Bit 3=Decode EAN with add-ons
001XX000
8
Bit 4=Decode Code 39 Bit 3=Decode extended Code 39
001XX000
9
Plessey control algorithms: Bit 4=Decode Plessey Bit 3=0 (Discard 2nd check digit) Bit 3=1 (Keep 2nd check digit) Bit 2=0 (Validate 1st check digit) Bit 2=1 (Do not validate) Bit 1=0 (Discard 1st check digit) Bit 1=1 (Keep 1st check digit) Bit 0=0 (MOD 11, 1st check digit) Bit 0=1 (MOD 10, 1st check digit)
001XXXXX
10
Enable Codabar algorithms. Bit 4=Decode ABC Codabar Bit 3=Decode Codabar
001XX000
11
Enable Code 11 algorithm. Bit 4=Decode Code 11
001X0000
12
Enable Code 93 algorithm. Bit 4=Decode Code 93
001X0000
13
Enable Code 128 algorithm. Bit 4=Decode Code 128
001X0000
14
Enable Straight 2 of 5 and Computer Identics 2 of 5 algorithms. Bit 4=Decode Straight 2 of 5 Bit 3=Decode C-Identics 2 of 5
001XX000
190
Native Terminal Emulation Programmer’s Guide
Page 211
Chapter 6, Terminal Commands
StD/ Bar Code Parameters (continued) Byte Position Description
Bit Position
15
Maximum bar code length for Straight and Computer Identics 2 of 5. Bits 0-4=Length
010XXXXX
16
Minimum bar code length for Straight and Computer Identics 2 of 5. Bits 0-4=Length
010XXXXX
17
1st fixed bar code length for Straight and Computer Identics 2 of 5. Bits 0-4=Length
010XXXXX
18
2nd fixed bar code length for Straight and Computer Identics 2 of 5. Bits 0-4=Length
010XXXXX
19
Enable Interleaved 2 of 5 algorithm. Bit 4=Decode Interleaved 2 of 5
001X0000
20
Maximum bar code length for Interleaved 2 of 5. Bits 0-4=Length
010XXXXX
21
Minimum bar code length for Interleaved 2 of 5. Bits 0-4=Length
010XXXXX
22
1st fixed bar code length for Interleaved 2 of 5. Bits 0-4=Length
010XXXXX
23
2nd fixed bar code length for Interleaved 2 of 5. Bits 0-4=Length
010XXXXX
Enable a bar code by giving the parameters at least as many bytes as the position of the desired control byte. For example, to enable Plessey, parameters must have at least nine bytes. When bit positions have been determined, ASCII equivalents integrate into the following character. 01011101=5D (hex)=“]” (ASCII) StD B
T5 / @ 0 0 O H 4 8 0
8 <cr>
StD/ (Set Terminal Parameters) command
Enable ABC Codabar <space> Disable Plessey Enable Code 39
Disable buzzer Set comm. loss timer to 5 seconds
Reserved control byte Enable scanner, do not select wand, CCD or Redundancy (defaults to laser in use) Do not send bar code type as first character
Enable EAN EAN with add-ons Enable UPC Expand UPCE to UPCA
48H=01 001000=810 Minimum length=8 4FH=01 001111 Maximum bar code length=15
This illustration shows an example of an expanded StD/ command code.
Native Terminal Emulation Programmer’s Guide
191
Page 212
Chapter 6, Terminal Commands
The following is a bit pattern hexadecimal to ASCII chart. Hexadecimal-to-ASCII Chart Bit Pattern
Hex
ASCII
Bit Pattern
Hex
ASCII
Bit Pattern
Hex
ASCII
00100000
20
<space>
01000000
40
@
01100000
60
‘
00100001
21
!
01000001
41
A
01100001
61 a
00100010
22
”
01000010
42
B
01100010
62 b
00100011
23
#
01000011
43
C
01100011
63 c
00100100
24
$
01000100
44
D
01100100
64 d
00100101
25
%
01000101
45
E
01100101
65 e
00100110
26
&
01000110
46
F
01100110
66 f
00100111
27
’
01000111
47
G
01100111
67 g
00101000
28
(
01001000
48
H
01101000
68 h
00101001
29
)
01001001
49
I
01101001
69 i
00101010
2A
*
01001010
4A
J
01101010
6A j
00101011
2B
+
01001011
4B
K
01101011
6B k
00101100
2C
,
01001100
4C
L
01101100
6C l
00101101
2D
-
01001101
4D
M
01101101
6D m
00101110
2E
.
01001110
4E
N
01101110
6E n
00101111
2F
/
01001111
4F
O
01101111
6F o
00110000
30
0
01010000
50
P
01110000
70 p
00110001
31
1
01010001
51
Q
01110001
71 q
00110010
32
2
01010010
52
R
01110010
72 r
00110011
33
3
01010011
53
S
01110011
73 s
00110100
34
4
01010100
54
T
01110100
74 t
00110101
35
5
01010101
55
U
01110101
75 u
00110110
36
6
01010110
56
V
01110110
76 v
00110111
37
7
01010111
57
W
01110111
77 w
00111000
38
8
01011000
58
X
01111000
78 x
00111001
39
9
01011001
59
Y
01111001
79 y
00111010
3A
:
01011010
5A
Z
01111010
7A z
00111011
3B
;
01011011
5B
[
01111011
7B
{
00111100
3C
<
01011100
5C
\
01111100
7C
|
00111101
3D
=
01011101
5D
]
01111101
7D
}
00111110
3E
>
01011110
5E
^
01111110
7E
~
00111111
3F
?
01011111
5F
_
01111111
7F
DEL
192
Native Terminal Emulation Programmer’s Guide
Page 213
Chapter 6, Terminal Commands
WtB (Audio Annunciator) WtB turns on the terminal audio tone for a specified time, in increments of 1/4 second up to 2.25 seconds.
Command WtBd<cr>
DCS or Gateway Response OK<cr>
R Response tC0<cr>
Command and R Response Variables S t
Terminal number (000–126)
S d
Audio tone duration times 250 milliseconds (1–9 seconds)
Example Command: W010B8<cr> Action: Terminal 010 sounds tone for 2 seconds.
Native Terminal Emulation Programmer’s Guide
193
Page 214
Chapter 6, Terminal Commands
WtD/ (Write Display) WtD/ sends data to a terminal and enables its response. WtD/ downloads the prompt, which appears on the terminal, and sets up input parameters. The single input field is returned to the host.
Command WtDo/x<cr>
DCS or Gateway Response OK<cr>
R Response tKrd<cr> tSrbcm<cr>
Data returns to the host when: 1 You press the [ENTER] key. 2 The field is filled and the [ENTER] option is disabled. 3 The display scrolls to the top or bottom with the wrap disabled. 4 The scanner reads a valid bar code.
Command Variables S t
Terminal number (000–126)
S o
Options (see the “Write Display Options” table on the next page)
S x
Data
| (0x7C) Allows all command extensions
(see “Command Extensions” on page 196)
194
Native Terminal Emulation Programmer’s Guide
Page 215
Chapter 6, Terminal Commands
Write Display Options o
Description
Default
.
The “.” (decimal point) key is always allowed if the N option is not set.
Not allowed if the N option is set.
-
The “-” (minus sign) key is always allowed if the N option is not set.
Not allowed if the N option is set.
B
Sounds tone (StD/ sets the duration)
Tone off
C
Displays cursor
Not displayed
D
Displays keyed-in data
Not displayed
E
[ENTER] required to transmit data
Not required
F
Current row returns as first character. All information is sent as a single block, not 112-byte blocks.
Not returned
Hx x=maximum length of keyboard input data. Values are 0-109.
3
Lx x=minimum length of keyboard input data. Values are 0-109.
0
M
MOD 10 check if option N is set, and options “.” and “-” are not set
No check
N
Numeric input data only
Alphanumeric
O
When the O option is enabled, the line with the cursor is in reverse video.
All the lines are shown in standard video
Px x=starting position of keyboard input. Values are 0-127.
0
Q
When the Q option is used and the [SKIP] key is pressed, the terminal automatically transmits the [SKIP] key to the host.
If Q is not used, the [SKIP] key is not auto-transmitted.
S
Enable scanning
Not enabled
U
Sets keyboard to SHIFT mode
Not shifted
W
Enables scroll wrap (up or down)
Not enabled
R Response Variables S t
Terminal number (000–126)
S K
Keyboard data
S r
Optional ASCII display row number
S d
Keyboard input data
S S
Scanner data. If “F” option is enabled, response is always “S.”
S b
Bar code type
S c
Bar code data
S m
MOD 10 check digit, if enabled
Native Terminal Emulation Programmer’s Guide
195
Page 216
Chapter 6, Terminal Commands
Example W002DDCBSH6L3P16/SCAN BARCODE<cr> where: S D=display key data in the display S C=cursor displayed S B=beep when displayed S S=enable scanning S H6=maximum key data is 6 S L3=minimum key data is 3 S P16=cursor is in position 16 Response: SCAN BARCODE
Command Extensions The vertical bar character “|” allows the following extensions.
Bank Data to be substituted for |Dxx allows for a macro extension defined by the WtD/\B (Set Bank) command. Following are Bank limitations: S Banks cannot be nested. S Banks cannot recursively call other banks inside the extension. S A field retains its own prescribed limitations. S WtD/ (Write Display) command of up to 1000 characters.
Syntax |Dxx (00 ≤ xx ≤ 99)
Blank Syntax |xx (00 ≤ xx ≤ 99 blank spaces)
Beep The terminal beeps for the length defined by the StD/ command for each occurrence of the |B extension.
Syntax |B
Cursor Position The cursor (if enabled) appears at this location.
Syntax |C
196