Native Terminal Emulation Programmer's Guide: Chapter 4: Customizing Your Configuration, pages 150 to 158

Pages 150 to 158 of 340, from Native Terminal Emulation Programmer's Guide

The original document is the PDF (2.9 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Intermec 2435

Page 150

Chapter 4, Customizing Your Configuration

S System 1 UPCE (not supported on 6400) [Session 1].UPC.Sys 1 UPCE Session 2.UPC.Sys 1 UPCE Enabled [Disabled]

EAN Options S Add-On 2 [Session 1].EAN.Add-On 2 Session 2.EAN.Add-On 2 Enabled [Disabled] S Add-On 5 [Session 1].EAN.Add-On 5 Session 2.EAN.Add-On 5 Enabled [Disabled] S Expand 8 to 13 [Session 1].EAN.Expand 8to13 Session 2.EAN.Expand 8to13 Enabled [Disabled]

Code 39 Options S Auto-Encoded [Session 1].Code 39.Auto-Encoded Session 2.Code 39.Auto-Encoded Enabled [Disabled] S Check Digit [Session 1].Code 39.Chk Digit Session 2.Code 39.Chk Digit Enabled [Disabled] S Data Decode [Session 1].Code 39.Data decode Session 2.Code 39.Data decode Enabled [Disabled] S Element Decode [Session 1].Code 39.Element decod Session 2.Code 39.Element decod Enabled [Disabled] S Encoded [Session 1].Code 39.Encoded Session 2.Code 39.Encoded Enabled [Disabled]

130

Native Terminal Emulation Programmer’s Guide

Page 151

Chapter 4, Customizing Your Configuration

S Extended [Session 1].Code 39.Extended Session 2.Code 39.Extended Enabled [Disabled] S Full ASCII [Session 1].Code 39.Full ASCII Session 2.Code 39.Full ASCII Enabled [Disabled] S Quiet Zone [Session 1].Code 39.Quiet zone Session 2.Code 39.Quiet zone Enabled [Disabled] S START Decode [Session 1].Code 39.START decode Session 2.Code 39.START decode Enabled [Disabled]

Interleaved 2 of 5 Option S Interleaved 2 of 5 Chk Digit [Session 1].Int 2of5.Chk Digit Session 2.Int 2of5.Chk Digit Enabled [Disabled]

Code 11 Options S Check Digit 1 (not supported on 6400) [Session 1].Code 11.Chk Dig 1 Session 2.Code 11.Chk Dig 1 Enabled [Disabled] S Check Digit 2 (not supported on 6400) [Session 1].Code 11.Chk Dig 2 Session 2.Code 11.Chk Dig 2 Enabled [Disabled]

Native Terminal Emulation Programmer’s Guide

131

Page 152

Chapter 4, Customizing Your Configuration

Plessey Options S Allow Alpha [Session 1].Plessey.Allow Alpha Session 2.Plessey.Allow Alpha Enabled [Disabled] S MOD 10 Check [Session 1].Plessey.MOD10 Chk Session 2.Plessey.MOD10 Chk Enabled [Disabled] S MOD 11 Check [Session 1].Plessey.MOD11 Chk Session 2.Plessey.MOD11 Chk Enabled [Disabled]

Code 128 Options S No UCC Type [Session 1].Code 128.NO UCC Type Session 2.Code 128.NO UCC Type Enabled [Disabled] S UCC/EAN [Session 1].Code 128.UCC/EAN Session 2.Code 128.UCC/EAN Enabled [Disabled]

132

Native Terminal Emulation Programmer’s Guide

Page 153

Chapter 4, Customizing Your Configuration

S UCC F1 Value [Session 1].UPC.UCC F1 Value Session 2.UPC.UCC F1 Value [Session 1].EAN.UCC F1 Value Session 2.EAN.UCC F1 Value [Session 1].Code 128.UCC F1 Value Session 2.Code 128.UCC F1 Value [Session 1].Code 39.UCC F1 Value Session 2.Code 39.UCC F1 Value [Session 1].Codabar.UCC F1 Value Session 2.Codabar.UCC F1 Value [Session 1].ABC Codabar.UCC F1 Value Session 2.ABC Codabar.UCC F1 Value [Session 1].Str 2of5.UCC F1 Value Session 2.Str 2of5.UCC F1 Value [Session 1].Int 2of5.UCC F1 Value Session 2.Int 2of5.UCC F1 Value [Session 1].CI 2of5.UCC F1 Value Session 2.CI 2of5.UCC F1 Value [Session 1].Code 11.UCC F1 Value Session 2.Code 11.UCC F1 Value [Session 1].Code 93.UCC F1 Value Session 2.Code 93.UCC F1 Value [Session 1].Plessey.UCC F1 Value Session 2.Plessey.UCC F1 Value Numeric, minimum = 0, maximum = 255

Native Protocol Options S F1 is Function –0 [Session 1].F1 is FUNC–0 Session 2.F1 is FUNC–0 Enabled [Disabled]

Display Options S Backlight State [Session 1].Backlight State Session 2.Backlight State Enabled [Disabled] S Backlight Timer (not supported on 5055) [Session 1].Backlight Timer Session 2.Backlight Timer Numeric, minimum = [0], maximum = 60 (2415, 2425, 2435A, 2455, 2475, 248X) Numeric, minimum = [0], maximum = 255 (6400, 17XX, 11XX)

Native Terminal Emulation Programmer’s Guide

133

Page 154

Chapter 4, Customizing Your Configuration

S Contrast Mode (59XX, 17XX, 11XX) [Session 1].Contrast Mode Session 2.Contrast Mode [Compensated] Absolute S Cursor Mode [Session 1].Cursor Mode Session 2.Cursor Mode Underln Blink (2415, 2425, 2435A, 2455, 2475, 248X, 6400, 59XX, 17XX, 11XX) Block Blink (2415, 2425, 2435A, 2455, 2475, 248X, 6400, 59XX, 17XX, 11XX) Underline (6400, 5055, 59XX, 17XX, 11XX) Block (6400, 5055, 59XX, 17XX, 11XX) [Underln Blink] is the default for 2415, 2425, 2435A, 2455, 2475, and 248X Terminals. [Block] is the default for 6400, 5055, 59XX, 17XX, and 11XX Terminals. S Remote Baud (17XX, 11XX) [Session 1].Remote Baud Session 2.Remote Baud 9600 19200 [38400] S Remote Display (17XX, 11XX) [Session 1].Remote Disp Session 2.Remote Disp Enabled [Disabled] S Remote Display Remote Columns (17XX, 11XX) Session 1.Remote Cols Session 2.Remote Cols Numeric, minimum = 1, maximum = 255 [80] S Remote Display Remote Rows (17XX, 11XX) [Session 1].Remote Rows Session 2.Remote Rows Numeric, minimum = 1, maximum = 255 [24] S Remote Display Remote Type (17XX, 11XX) [Session 1].Remote Type Session 2.Remote Type VT100 VT220 [ANSI]

134

Native Terminal Emulation Programmer’s Guide

Page 155

Chapter 4, Customizing Your Configuration

Radio Communications Options Note: Radio Communications options do not apply to 2415, 2425, 2435A, 2455, 2475, or 248X terminals that do not have an 802.1x supplicant radio driver installed. Set the Security ID for these terminals through the TRAKKER Antares 2400 Menu System. S Baud Rate (UHF radio) Radio Baud Rate 4800 4800/9600 9600 The default depends on the type of radio in the terminal. S Protocol (6400, 5055, 59XX, 17XX, 11XX) Radio Protocol The following qualifiers apply to UHF: RTC Adaptive Poll RTC-Diag Mode The following qualifiers apply to SST: SST SST-Diag Mode The default depends on the type of radio and is either RTC or SST. S Security ID [Session 1].Security ID Session 2.Security ID String, minimum length=0, maximum length=16 [null string] Default is NORANDOWL for 6400, 5055, 59XX, 17XX, 11XX. S User Authentication (2415, 2425, 2435A, 2455, 2475, 248X with 802.1x supplicant radio driver installed) [Session 1].User Auth Session 2.User Auth Enabled [Disabled]

More Options S Change Menu Password The password must be enabled and set for access to the Main Menu before you can change it. To set the password: [Session 1].Change Menu Password Session 2.Change Menu Password String, minimum length = 1, maximum length = 10 [3193693] To enable the password, see “Main Menu password.” S COM Select (248X, 5055) [Session 1].Com Select Session 2.Com Select [COM 1] COM 2

Native Terminal Emulation Programmer’s Guide

135

Page 156

Chapter 4, Customizing Your Configuration

S Main Menu Password The password must be enabled and set for access to the Main Menu. To enable or disable the password: [Session 1].Menu Password Session 2.Menu Password Enabled [Disabled] To set the password, see “Change menu password.” S Print Device (6400) [Session 1].Print Device Session 2.Print Device [RS232 Print] IRDA Print (6400)

LCD Options S Annunciator Format [Session 1].Annun Format Session 2.Annun Format [Vertical] 2455, 2475, 248X, 5055, 59XX [Horizontal] 2415, 2425, 2435A, 6400 S Annunciator Position [Session 1].Annun Position Session 2.Annun Position Upper Right Upper Left [Lower Right] 6400, 5055, 59XX, 17XX, 11XX Lower Left [Stealth] 2415, 2425, 2435A, 2455, 2475, 248X S Backlight Intensity (59XX) [Session 1].BLight Intensity Session 2.BLight Intensity Numeric, minimum = 0, maximum = 15 S Define Height (Scroll Window) [Session 1].Define Height Session 2.Define Height Numeric, minimum = 1, maximum = 24 [8] S Define Width (Scroll Window) [Session 1].Define Width Session 2.Define Width Numeric, minimum = 1, maximum = 80 [8] S Key Uppercase [Session 1].Key Uppercase Session 2.Key Uppercase [Enabled] Disabled

136

Native Terminal Emulation Programmer’s Guide

Page 157

Chapter 4, Customizing Your Configuration

S LCD Contrast (59XX, 17XX) [Session 1].LCD Contrast Session 2.LCD Contrast Numeric, minimum = [0], maximum = 255 S Screen Columns [Session 1].Screen Cols Session 2.Screen Cols Numeric, minimum = 1, maximum = 255 [16] 11XX [17] 17XX [19] 2435A [20] 2415, 2425, 2455, 2475, 248X [40] 59XX [80] 5055 [16] 6400 wide display S Screen Mode [Session 1].Screen Mode Session 2.Screen Mode Center Cursor [Corner Mode] Page Mode Lazy Mode Locked Mode S Screen Rows [Session 1].Screen Rows Session 2.Screen Rows Numeric, minimum = 1, maximum = 255 [8] 11XX [8] 17XX [10] 59XX [16] 2415, 2425, 2435A, 2455, 2475, 248X [25] 5055 [16] 6400 wide display S Scroll Window [Session 1].Scroll Window Session 2.Scroll Window Screen Size Scroll Setting [Tab Size] S XOrigin [Session 1].XOrigin [Session 2].XOrigin Numeric minimum = 0, maximum = 79 [0] S YOrigin [Session 1].YOrigin [Session 2].YOrigin Numeric minimum = 0, maximum = 23 [0]

Native Terminal Emulation Programmer’s Guide

137

Page 158

Chapter 4, Customizing Your Configuration

Beeper Setup Options Note: Beeper setup options do not apply to the 2415, 2425, 2435A, 2455, 2475, and 248X Terminals. S Beep Head Set (17XX) [Session 1].Beep Head Set Session 2.Beep Head Set Enabled [Disabled] S Beep Internal (not supported on 59XX) [Session 1].Beep Internal Session 2.Beep Internal [Enabled] Disabled S Beeper (Error Tone) Frequency (not supported on 59XX) [Session 1].Beep Frequency Session 2.Beep Frequency Numeric, minimum = 0, maximum = 30 [13] 11XX and 17XX [6] 6400 S Beeper (Error Tone) Length [Session 1].Beep Length Session 2.Beep Length Numeric, minimum= 1 , maximum= 10 [3] S Beeper (Error Tone) Volume (59XX) [Session 1].Beep Volume Session 2.Beep Volume Numeric, minimum = 0, maximum = 255 [95] S Key Click Frequency (not supported on 59XX) [Session 1].KeyClick Freq Session 2.KeyClick Freq Numeric, minimum = 0, maximum = 30 [13] 17XX and 11XX [6] 6400 S Key Click Length [Session 1].KeyClick Length Session 2.KeyClick Length Numeric, minimum = 1, maximum = 10 [1] 59XX, 17XX, and 11XX [6] 6400 and 5055 S Key Click Volume (59XX) [Session 1].KeyClick Volume Session 2.KeyClick Volume Numeric, minimum = 0, maximum = 255 [95]

138