Page 105

Chapter 3, Using the Terminal Emulation Menus

3) Frequency (6400, 17XX, 11XX) Press [3], then the up and down arrow keys to adjust the tone frequency in steps from 0 to 32.

Key Click 1) Volume 2) Length 3) Frequency

Volume Use Cursor Up And Down Keys To Adjust

[1]

1) Volume is for 59XX 3) Frequency is for 6400, 17XX, 11XX

[2]

Key Click> xx

Frequency Use Cursor Up And Down Keys To Adjust

Length Use Cursor Up And Down Keys To Adjust Key Click> xx

[3]

Key Click> xx

2) Error Tone 2) Error Tone adjusts the length and frequency of the tone made when an error occurs (for example, pressing an invalid key). The 2) Error Tone adjustments, and the procedures for making them are identical to the 1) Key Click adjustments. Press 2) Length to set the length. The range is 1 through 10, which equates to a 500 to 5000 ms beep for all errors. Default error tone length is 3 (or 1500 ms). Error Tone 1) Volume 2) Length 3)

Volume Use Cursor Up And Down Keys To Adjust Error Tone> xx

Native Terminal Emulation Programmer’s Guide

[1]

1) Volume is for 59XX

[2]

Length Use Cursor Up And Down Keys To Adjust Error Tone> xx

85

Page 106

Chapter 3, Using the Terminal Emulation Menus

3) Beeper Select (6400, 5055, 17XX, 11XX) For 17XX, 11XX, both buzzers are not allowed to beep simultaneously when using a headset. If both options are enabled, the head set buzzer will beep first before the internal buzzer. If you are using the RS-232 port for communications, enable 1) Beep Internal and disable 2) Beep Head Set.

1) Beep Internal Press [1] to direct the audio to the internal beeper. Default is enabled.

2) Beep Head Set (17XX, 11XX) Press [2] to direct sound to the headset. Beeper Setup 1) Beep Internal 2) Beep Head Set

2) Beep Head Set is for 17XX, 11XX

4) Tests Intermec Systems Engineers use the 4) Tests menus to verify terminal operation during environmental stress tests, peripherals, the display, RF communications, and memory. Tests 1) Peripherals 2) Converters 3) Memory View 4) Packet Driver 5) Numbers 6) Timed Numbers

2) Converters is for 59XX 3) Memory View and 4) Packet Driver are for 6400, 5055, 59XX, 17XX, 11XX

1) Peripherals Select 1) Peripherals to test terminal peripheral devices, such as radio, RS-232, display, keyboard, and scanner. Detailed descriptions of each peripheral test follows. Peripherals 1) Radio Test 2) RS232 Test 3) Display Test 4) Keyboard Test 5) Scanner Test

86

1) Radio Test is for 6400, 5055, 802.11 (Lucent) radios 2) RS232 Test, 3) Display Test, and 4) Keyboard Test are for 6400, 5055, 59XX, 17XX, 11XX

Native Terminal Emulation Programmer’s Guide

Page 107

Chapter 3, Using the Terminal Emulation Menus

1) Radio Test (802.11 (Lucent) Radios, 6400, 5055) Several factors influence the rate at which a frame is transmitted. First, the radio’s transmission rate is configured in the net.cfg file. The keyword Transmit_Rate in net.cfg holds a numeric value for the transmission rate. The transmission rate is also affected by the characteristics of the RF link. If the radio encounters problems sending a higher transmission rate because the RF link is weak, busy, or noisy, the radio may retry the transmission at a lower data rate. Thus, the TxRate reported may be lower than the configured transmission rate. Only the transmission rate of the most recent and successful transmission is reported. Transmit_Rate values and their respective supported transmission rates available in the high speed Lucent radios are as follows: 1 Fixed Low (1 Mb/s) 5 Fixed High (11 Mb/s) 2 Fixed Standard (2 Mb/s) 4 ARS Standard (2 Mb/s) 3 ARS High (11 Mb/s default) 4 ARS Medium (5.5 Mb/s) 4 Fixed Medium (5.5 Mb/s) S PRI The primary version of low-level radio firmware. S SEC The secondary version of the low-level radio firmware. S RFLINK A general description of the RF connection overall quality between Lucent radios in the terminal and radios in the Access Point. The Lucent radio grades the RF link on a scale from 0–92, representing the RF channel Signal-to-Noise Ratio. The RF link quality descriptions are assigned as: 0–23 “Adequate,” 24–47 “Good,” or 48–92 “Excellent.” S SNR (Signal-to-Noise Ratio) Calculated by dividing the RF signal level by the RF noise level. The result is a number that indicates the overall communications quality of the RF link and is expressed in dBm. S SSID (Service Set ID) A 32-character, alphanumeric string that identifies the service set, or infrastructure, with which the terminal is currently associated. The SSID is a user-configurable parameter and is configured by the keyword WaveLAN_Network_Name in the net.cfg file. Setting the keyword to ANY allows the station to associate with any service set. S B SSID (Basic Service Set ID) The 6-byte MAC address of the Lucent radio in the Access Point with which the station is associated. The Lucent radio in the terminal may associate with a non-Lucent (but 802.11-compliant) radio in an Access Point. Looking at the first three bytes of the MAC address (OUI) can help identify the Access Point radio’s manufacturer.

Example An OUI of “00601D” points to a Lucent radio, while “0020A6” indicates a Proxim radio.

Native Terminal Emulation Programmer’s Guide

87

Page 108

Chapter 3, Using the Terminal Emulation Menus

S TxRate The data rate (in Mb/s) of the last message transmitted by the Lucent radio. The default TXRate of 2 Mb/s and is displayed when the terminal starts up and has not transmitted a frame yet. High speed Lucent radios are capable of data rates of 1 Mb/s, 2 Mb/s, 5.5 Mb/s, and 11 Mb/s. The TxRate 5.5 Mb/s data rate is displayed as 6 Mb/s. This occurs because the Lucent radio reports an integer value for current transmission data rate, so the data rate of 5.5 Mb/s is rounded up to 6 Mb/s. Radio Test PRI: v4.0 SEC: v4.52 RFLINK: Excellent SNR: 99dBm SSID: xxxxxxx B SSID: xxxxxxxxxxxx TxRate:xMb/s std

Primary version of Lucent driver Secondary version of driver RF link quality Signal-to-Noise ratio Network name in use MAC address of access point Data rate

2) RS232 Test (6400, 5055, 59XX, 17XX, 11XX) Tests the data communication port on the terminal, requiring a special loop-back connector that links the following input and output pins on the data connector: S TX output to the RX input S DTR output to the DSR input S CTS output to the RTS input To run the test, select 2) RS232 Test, attach the loop-back connector to the port connector on the terminal, then press [Enter]. The display changes to the second RS232 Test menu shown below. The condition of each line-pair displays as passing or failing the test. If any test fails, return the terminal for service. RS232 Test Attach RS232 Loopback Connector Press Enter

RS232 Test RTS-CTS: PASS DTR–DSR: PASS TX-RX: PASS Any Key To Stop

88

Native Terminal Emulation Programmer’s Guide

Page 109

Chapter 3, Using the Terminal Emulation Menus

3) Display Test (6400, 5055, 59XX, 17XX, 11XX) 3) Display Test tests the operation of and activates each element in the terminal LCD panel. If a line appears broken, or there are gaps in the display, replace the LCD panel. 1 From the Display Test menu, press [Enter] to start the test. The display screen is painted with a series of vertical lines. Visually inspect the lines. All lines should appear clear and complete (no broken segments). 2 Press [Enter] to move to a screen drawn with horizontal lines. Visually inspect the lines using the same criteria. 3 Press [Enter] to move to the final screen. Visually inspect the painted black lines which should be uniformly black for monochrome displays and uniformly white for color displays. 4 Press [Enter] to return to the 1) Peripherals menu.

4) Keyboard Test (6400, 5055, 59XX, 17XX, 11XX) Tests each key on the terminal keypad or 5055 external keyboard. Press each key, except the [Enter] key, and a character corresponding to the pressed key should appear on the display. Keyboard Test Press A Key ENTER To Exit Key = ’A’

5) Scanner Test This option tests the operation of an attached bar code scanner. From this menu, scan an enabled bar code. The bar code and the bar code length should appear on the display to pass. Press any key to exit. Scanner Test Scan Code> Length>

Native Terminal Emulation Programmer’s Guide

89

Page 110

Chapter 3, Using the Terminal Emulation Menus

2) Converters (59XX) Use this option to test the analog-to-digital (A to D) and the digital-toanalog (D to A) converters. The RSSI Test (not available on all radios) offers a choice of graphics displays of the received radio signals. Press any key to exit. Converters 1) A to D 2) D to A 3)

3) Memory View (6400, 5055, 17XX, 11XX) This menu is reserved for engineering test and evaluation. Press [F1] to exit out of this test, [F2] to view the heap, [F3] to view the far heap, or [F4] to do a memory dump. Memory View F1 - Exit F2 - Heap F3 - Far Heap F4 - Memory Dump Address: xxxxxx

4) Packet Driver (6400, 5055, 59XX, 17XX, 11XX) 4) Packet Driver tests accuracy of data transmissions to and from the terminal. Packet Driver 1) 2) 3) Packet Stats 4) Histogram 5) 6)

90

3) Packet Stats is for 6400, 5055, 59XX, 17XX, 11XX

Native Terminal Emulation Programmer’s Guide

Page 111

Chapter 3, Using the Terminal Emulation Menus

3) Packet Stats (Statistics) (6400, 5055, 59XX, 17XX, 11XX) Shows the number of packets sent and received, number of errors, and number of packets dropped. Receive Statistics Pkt xxx Chr xxx Err xxx Lost xxx

Transmit Statistics Pkt xxx Chr xxx Err xxx * See Text ’Histogram Options’ Transaction Statistics Qty xxx Sec xxx Qty/Min xxx Ops xxx

RTC Statistics

Native Terminal Emulation Programmer’s Guide

91

Page 112

Chapter 3, Using the Terminal Emulation Menus

4) Histogram An Intermec engineer may ask you to access this menu if your terminal has problems. From this menu you can provide the Intermec system engineer with vital information about your unit. The actual menus are not shown in this manual, however some of the general terminology is shown below. Several of the menu options, such as “Clear. . ., ” are password-protected and are only accessible if the engineer provides you with the correct password. An Intermec system engineer will work with you on these selections. Terminology you might see: S avg tx time

S send retries

S avg trans time

S rcv retries

S ptt (push-to-talk) count

S reset count

S addrs on list

S interval time

S poll no data

S time bucket #

Histogram 1) Start 2) Stop 3) View

5) Numbers 5) Numbers checks the operation of the terminal microprocessor. During the test, the terminal display is filled with hexadecimal numbers that move across the screen horizontally and scroll vertically. Character movement indicates that the processor is still running. To stop the test, press any key. This test is helpful in detecting lockups during severe operating conditions.

6) Timed Numbers 6) Timed Numbers does the same thing as 5) Numbers except that it keeps track of the time in seconds that it took to run the test. The test terminates when a key is pressed or when 65,536 numbers are displayed.

92

Native Terminal Emulation Programmer’s Guide

Page 113

Chapter 3, Using the Terminal Emulation Menus

5) Version Info (Information) 5) Version Info shows the name, version, and release date of the program you are using, the version of the radio driver, and the MAC address of the 6400, 5055, or 11XX Terminal. See Chapter 1, “Getting Started,” for TE program names.

MLID Name and MLID ver are for 6400, 5055

Version Info Firmware <TE Program Name> Version <number> Date <ddmmyy> MLID Name ZZZZZZ MLID ver xx.xx (mac address)

6) Exit Menus Use 6) Exit Menus to exit the TE configuration menus. If you changed any parameter settings, the terminal displays the following when you exit the menus. Save Parms Enter ’Y’ to save parms

If you press [Y] (“yes”), you are prompted for a password. “cr52401” is the default password. Save Parms Enter Password > .......

Native Terminal Emulation Programmer’s Guide

93

Page 114

Chapter 3, Using the Terminal Emulation Menus

After you enter the correct password, your settings are saved to Flash, and the terminal may reboot. (Some changes automatically reboot the terminal.) If you press a key other than [Y], you exit the menus and the new settings are not saved. In this case, the new settings are lost when you reboot your terminal. When you exit the TE configuration menus, the following information appears: <TE program name> <version> Session: <number> Host: <data stream>

7) More (Main Menu 2) Select 7) More to open the Main Menu 2 screen. Main Menu 2 1) Keyboard Opts 2) Save Parms 3) Cloning Opts 4) Session Menu

3) Cloning Opts is for 59XX, 17XX, 11XX 4) Session Menu is for 2415 (WTP), 2425 (WTP), 2435A (WTP), 2455 (WTP), 2475 (WTP), 248X (WTP), 6400, 5055, 17XX, 11XX

1) Keyboard Opts Use 1) Keyboard Opts > 1) Type-Ahead to key in information when the terminal cannot immediately send data to the host computer. 1) Type-Ahead enters information when the terminal cannot immediately send data to the host. Keyboard Opts 1) Type - Ahead

This stores keystrokes after the Input Inhibited annunciator (below) appears on the status line, and then saves them for the next input field. Type-ahead is enabled by default.

X 94

Input Inhibited annunciator

Native Terminal Emulation Programmer’s Guide