The text of a manual · part 10 of 37
Native Terminal Emulation Programmer's Guide: Chapter 3: Using the Terminal Emulation Menus, pages 65 to 74
Pages 65 to 74 of 340, from Native Terminal Emulation Programmer's Guide
The original document is the PDF (2.9 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 2435
Page 65
Chapter 3, Using the Terminal Emulation Menus
Server IP <A, B, or C> The Server <A> IP address is read from either the CONFIG.DAT (if one is saved) or the terminal firmware. When an IP address is entered, it gets written to the terminal’s firmware for the next boot. If you are using the Server <B> or Server <C> option as a fallback DCS 300, enter the server’s IP address or DNS name. The boot sequence will continue to try Server <A>, <B>, then <C> in this order by filling the firmware controller slot with the IP values entered for each server.
Host Setup <A, B, or C> Menu options are as follows: Host Setup<A, B, or C> 1) Host Name 2) Upline Prot 3) Port Number 4) Emulation
Host<A, B, or C> <3270, 5250, or VT/ANSI> Host Name <host name>
[1]
[2]
Port Number<A, B, or C> <port number> [3]
[4]
Upline Prot<A, B, or C> 1)Telnet 2)SNA
Emulation<A, B, or C> 1) 2) 3270 3) 5250 4) VT/ANSI
S 1) Host Name The host name can be 16 or fewer characters in length (with no spaces). It is case-sensitive and must match a host name in the list of available hosts defined on the DCS 300, or remain blank. The name can also be the IP address of the host to which you want to connect. Enter the IP address as four decimal numbers separated by periods. If a terminal was linked with a host name on the DCS 300, or a default host was configured on this DCS 300, you do not need to enter a host name on this screen. The terminal displays a list of available hosts if these conditions are met: S The DCS 300 contains multiple hosts. S The terminal is not linked with a host name on the DCS 300. S The host name is blank. The user can then select the host from the list.
Native Terminal Emulation Programmer’s Guide
45
Page 66
Chapter 3, Using the Terminal Emulation Menus
S 2) Upline Prot(ocol) When enabled, upline protocol options do the following: S Telnet (Default) Forces the DCS 300 to create a Telnet connection to the host. S SNA Forces the DCS 300 to create an SNA connection to the host. S 3) Port Number This option overrides the port number set for the upline if you have entered a host name and selected Telnet as your upline protocol. Default port number is 23. The maximum port number is 65535. S 4) Emulation Use this option to tell the terminal each host computer type. Default is 3270. Note: You can also set the type through the 2) Data Stream option on the 3) Protocol Opts menu.
2) RTC/WTP (2415, 2425, 2435A, 2455, 2475, 248X) Use 2) RTC/WTP to set, view, or change the terminal ID. This number allows the host computer to identify individual terminals in the radio data network. Each terminal must have a unique number in the same network. Use the numeric keys on the terminal keyboard to modify its ID. Enter a number between 0–126, then press [Enter] to go to the 2) Host/Cntl menus. The 1) Radio Setup and 2) Host/Cntl menus are shown on the following pages. Pending on which option you are exercising you will either advance to the WTP Stack settings or the TCP/IP Stack settings. 1) Radio Setup is done in the firmware with the RTC stack.
46
Native Terminal Emulation Programmer’s Guide
Page 67
Chapter 3, Using the Terminal Emulation Menus
WTP Stack Options
Controller Type 1) 2) RTC/WTP 3)
[2] Host/Cntl 1) 2) Host/Cntl
[2] Host/Cntl 1) CNTL A 2) CNTL B 3) CNTL C ENTER
DONE
ENTER
Controller (x) Enter Unit Number xxx
ENTER Controller (x) (cust emulation) unit # xxx Host Name Enter up to 16 characters/Numbers for a name. ENTER Emulation (x) Enter Unit 1) Native 2) 3270 3) 5250 4) VT/ANSI
ENTER
Telnet (x) 1) Enabled 2) Disabled
Native Terminal Emulation Programmer’s Guide
ENTER
47
Page 68
Chapter 3, Using the Terminal Emulation Menus
2) RTC/WTP (6400, 5055, 59XX, 17XX, 11XX) Use 2) RTC/WTP to set, view, or change the terminal ID. This number allows the host computer to identify individual terminals in the radio data network. Each terminal must have a unique number in the same network. The 1) Radio Setup and 2) Host/Cntl menus are shown on the following pages. Pending on which option you are exercising you will either advance to the WTP Stack settings or the TCP/IP Stack settings. S WTP Settings Use the numeric keys on the terminal keyboard or 5055 external keyboard to modify its ID. Enter a number between 0–126, then press [Enter] to go to the 2) Host/Cntl menus. The LAN ID number can be 0–255 depending on the radio being used. With the RM60/70 radio, the number can be 0–255; with the RM80/90 radio, the range is 0–15. Your terminal only communicates with equipment using the same ID number that you assigned to your LAN. If you enter a LAN ID number different from what is configured in the NET.CFG file you get the following message. If this happens, the system modifies NET.CFG, which is used by WTPPKT.EXE on initializing the terminal.
LAN ID changed Need to reboot to take effect.
48
Native Terminal Emulation Programmer’s Guide
Page 69
Chapter 3, Using the Terminal Emulation Menus
WTP Stack Options Controller Type 1) 2) RTC/WTP 3)
[2] Host/Cntl 1) Radio Setup 2) Host/Cntl
[1]
For 802.11 Radios Only
[2]
Go to Host/Cntl on the next page
For Non 802.11 Radios
Radio Setup Network Name
Radio Setup LAN xxxx Enter up to 34 characters for a name xx
ENTER
Radio Setup Radio Config#
Only if a “radio cfg“ file is present on the terminal.
ENTER (5055 -- continue to Host/Cntl setups)
Set Mode/Channel is for RM60 (902 MHz) radios
Set Mode/Channel Use Cursor Up and Down Keys To Adjust DS xxxx channel xx
Set Frequency Use Cursor Up and Down Keys To Adjust
Set Frequency is for Synthesized UHF radios xxxxxxxxx ENTER (continue to Host/Cntl setups)
Native Terminal Emulation Programmer’s Guide
49
Page 70
Chapter 3, Using the Terminal Emulation Menus
ENTER
Host/Cntl Settings Host/Cntl 1) CNTL A 2) CNTL B 3) CNTL C ENTER
DONE
ENTER
Controller (x) Enter Unit Number xxx
ENTER Controller (x) (cust emulation) unit # xxx Host Name Enter up to 16 characters/Numbers for a name. ENTER Emulation (x) Enter Unit 1) Native 2) 3270 3) 5250 4) VT/ANSI
ENTER
Telnet (x) 1) Enabled 2) Disabled
50
ENTER
Native Terminal Emulation Programmer’s Guide
Page 71
Chapter 3, Using the Terminal Emulation Menus
2) Barcode Parms (2415, 2425, 2435A, 2455, 2475, 248X) The 2) Barcode Parms (parameters) menus designate whether you are using a bar code scanner and scan options. Barcode Parms 1) Code 39 Encoded 2) 3) Concatenate 4) RS232 Stream 5) Stream Scan 6) Scan All Flds
1) Code 39 Encoded By default, 1) Code39 Encoded is disabled. When you enable this option, the key press sequences for Encoded Code 39 are used. For more information, see Appendix A, “Bar Code Scanning.”
3) Concatenate Each bar code read is added to the end of the previous bar code read until the 2415, 2425, 2435A, 2455, 2475, or 248X Terminal meets a condition forcing transmission to the host. When this option is OFF, each bar code read is placed at the beginning of the current input field. After a bar code is placed in a field, any subsequent read replaces the first read. Note: If you access the TE configuration menus when 4) RS232 Stream is enabled, all RS-232 data received during this time is lost. Only the data arriving from the COM1 port on the hand-held terminal is received.
4) RS232 Stream If this option is enabled, the terminal watches the RS-232 port for activity in which the terminal reads in the RS-232 data and sends it to the host. This enables support for fixed-station scanners or scales that send only RS-232 data without having the host send an extended command to enable the RS-232 port. Default for 4) RS232 Stream is disabled.
5) Stream Scan If the scanned bar code is too big for the input field, the overflow information appears in the next field and continues until the entire bar code is entered. When this option is OFF, and the scanned bar code is too big for the input field, the overflow information is dropped.
6) Scan All Flds (Fields) When this option is selected, the scanner is enabled when the cursor is in an input field. When this option is OFF, the host computer must enable the scanner for each input field that requires scanned data.
Native Terminal Emulation Programmer’s Guide
51
Page 72
Chapter 3, Using the Terminal Emulation Menus
2) Barcode Parms (6400, 5055, 59XX, 17XX, 11XX) Selecting 2) Barcode Parms (parameters) displays the Scanner Type menu.
Scanner Type Use the Scanner Type menu to designate the type of bar code scanner. To make a selection, press the numeric key corresponding to the desired option, then press [Enter] to access the Scan Options menu. Note: If 1) No Scanner is chosen, the remaining scanner and bar code options can be set. Then, if a scanner is used at a later time, only the scanner type needs to be designated. Selected options are highlighted on the display. Press a key corresponding to that option to deselect a selected option.
Scanner Type 1) No Scanner 2) Wand 3) Laser 4) Wand Emulate 5) Auto Detect
2) Wand, 4) Wand Emulate, and 5) Auto Detect are for 59XX, 17XX, 11XX
Scan Options Use the Scan Options menu to assign scan options, enable bar code symbologies to use (the terminal can only decode the enabled symbologies), and set options for each enabled bar code symbology, such as the bar code lengths. Press [Enter] to advance to the Scan Options 2 menus. Scan Options 1) Redundancy 2) MOD 10 Check 3) Concatenate 4) BC Type Char 5) Stream Scan 6) Scan All Flds 7) More
1) Redundancy and 4) BC Type Char are for 6400, 59XX, 17XX, 11XX 3) Concatenate is for 6400, 5055
S 1) Redundancy (6400, 59XX, 17XX, 11XX) This option requires two identical scans of a bar code, one right after another, before the terminal accepts the scan as valid. S 2) Mod 10 Check When you select this option, a check digit is added at the end of the bar code after a good read for transmission to the host. The host can then validate the transmission data using the check. This feature is not needed with modem transmission protocols. The bar code number is divided by 10, until the number (or modulus) is less than 10. If the modulus subtracted from 10 (remainder) is equal to zero, then the bar code number is valid.
52
Native Terminal Emulation Programmer’s Guide
Page 73
Chapter 3, Using the Terminal Emulation Menus
S 3) Concatenate (6400, 5055) Each bar code read is added to the end of the previous bar code read until the 6400 or 5055 terminal meets a condition forcing transmission to the host. When this option is OFF, each bar code read is placed at the beginning of the current input field. After a bar code is placed in a field, any subsequent read replaces the first read. S 4) BC Type Char (6400, 59XX, 17XX, 11XX) This option adds a character associated with the bar code type at the beginning of the scanned bar code. See page 268 for bar code type characters. S 5) Stream Scan If the scanned bar code is too big for the input field, the overflow information appears in the next field and continues until the entire bar code is entered. When this option is OFF, and the scanned bar code is too big for the input field, the overflow information is dropped. S 6) Scan All Flds (Fields) When this option is selected, the scanner is enabled when the cursor is in an input field. When this option is OFF, the host computer must enable the scanner for each input field that requires scanned data. S 7) More This brings you additional scanning options that adjust scanning timeout and characters sent before and after the scanned data. S 1) Scan Timeout (59XX, 17XX, 11XX) Use this option to adjust the scanning timeout period from 1 to 200 seconds. When using a proximity-detect scanner, you can shorten the timeout period to speed up scanning while also reducing the duration of errant scans. With a long-range scanner, you may want to increase the timeout period to ensure sufficient aiming time. Scan Timeout Seconds XXX
S 2) Scan PreChar and 3) Scan PostChar Enter a hexadecimal value from 00–FF for the character to be sent preceding the scanned data or after the scanned data. The value of 20h means that pre- or post-characters are not sent. Scan Options 1) Scan Timeout 2) Scan PreChar 3) Scan PostChar
Native Terminal Emulation Programmer’s Guide
1) Scan Timeout is for 59XX, 17XX, 11XX
53
Page 74
Chapter 3, Using the Terminal Emulation Menus
Scan Options to Enable Bar Codes There are menus of options to enable (or disable) various bar code symbologies. To enable a bar code, press the numeric key corresponding to the number of the bar code symbology (shown on menu), then press [Enter]. After enabling a particular bar code, options may have to be selected for the bar code. After selecting the desired options, set the length requirements (such as minimum and maximum length, fixed lengths, leading and trailing character options, etc.). Once the length requirements are set, the terminal returns to the same Scan Options menu. Choose another bar code symbology from that menu or press [Enter] to advance to the Scan Options 2 menu. Scan Options 1) UPC 2) EAN 3) Code 39 4) Code 128 5) Codabar
4) Sys 1 UPCE is for 6400, 17XX, 11XX
6) Relax Std is for 59XX, 17XX, 11XX
UPC 1) Enabled 2) Add-On 2 3) Add-On 5 4) Sys 1 UPCE 5) Sys 0 UPCE 6) Expand E To A
Code 39 1) Enabled 2) Chk Digit 3) Extended 4) Encoded 5) Auto-Encoded 6) Relax Std 7) Full ASCII
[1]
[3]
[2]
[4]
EAN 1) Enabled 2) Add-On 2 3) Add-On 5 4) Expand 8 To 13
Code 128 1) Enabled 2) UCC/EAN 3) No UCC Type 4) UCC F1 Value
[6] RELAX CODE 39 1) Quiet zone 2) Data Decode 3) Element Decode 4) START Decode
54
[5]
Codabar 1) Codabar 2) ABC Codabar
2) ABC Codabar is for 59XX, 17XX, 11XX
Native Terminal Emulation Programmer’s Guide