Page 405

B

Bar Code Symbologies

This appendix contains a brief explanation of each bar code symbology that the VT/ANSI TE 2000 application decodes. It explains some of the general characteristics and uses of these bar code types.

TE 2000™ VT/ANSI Terminal Emulation Programmer’s Guide

381

Page 406

Appendix B, Bar Code Symbologies

Bar Code Algorithms You can enable specific bar code algorithms using the setup menus or the host computer. Once the computer correctly decodes a bar code, the computer encodes data with descriptive information about the symbol. Response time is improved by limiting the computer to bar codes being used. Bar Code Data String Formats Bar Code Type Character

Symbology Type

Data Format

Data Length

“0”

UPC short (UPC-E)

nddddddc

8

“1”

EAN short (EAN-8)

fndddddc

8

“2”

UPC long (UPC-A)

nddddddddddc

12

“3”

EAN long (EAN-13)

fnddddddddddc

13

“4”

UPC short add-on 2 nddddddcaa

10

“5”

EAN short add-on 2 fndddddcaa

10

“6”

UPC long add-on 2 nddddddddddcaa

14

“7”

EAN long add-on 2 fnddddddddddcaa

15

“8”

UPC short add-on 5 nddddddcaaaaa

13

“9”

EAN short add-on 5 fndddddcaaaaa

13

“:” (colon)

UPC long add-on 5 nddddddddddcaaaaa

17

“;” (semicolon)

EAN long add-on 5 fnddddddddddcaaaaa

18

“<” (less than)

Interleaved 2 of 5 d......d

Scan device dependent

“=” (equal sign)

Standard 2 of 5 d......d

Scan device dependent

“>” (greater than)

Plessey d......dc

Scan device dependent

“@” (ampersand)

Codabar sd....ds

Scan device dependent

“S”

Code 11 d......d

Scan device dependent

“P”

Code 39 d......d

Scan device dependent

“Q”

Extended Code 39 d......d

Scan device dependent

“R”

Code 93 d......d

Scan device dependent

“J”

Code 128 d......d

Scan device dependent

Note: These bar code data definitions apply to the Data Format column in the previous table: a Add-on code digits c Check digits d Bar code digits f EAN flag 1 characters n Number system digits s Start and stop digits If MOD 10 or MOD 11 check digits are enabled, the digit falls at the end of a bar code data string. Each check digit enabled extends the bar code data string length by one character.

382

TE 2000™ VT/ANSI Terminal Emulation Programmer’s Guide

Page 407

Appendix B, Bar Code Symbologies

The VT/ANSI TE 2000 application recognizes eleven of the most widely used bar code symbologies. With bar code symbologies, like languages, there are many different types. A bar code symbology provides the required flexibility for a particular inventory tracking system. A symbology may be for particular industries, such as food and beverage, automotive, railroad, or aircraft. Some of these industries have established their own bar code symbology because other symbologies did not meet their needs. Without going into great detail on the bar code structure, note that no two products use the same bar code. Each product gets a unique bar code. Industries that use a particular type of bar code symbology have formed regulating committees or are members of national institutes that issue and keep track of bar codes. This ensures that each organization that contributes to a particular industry conforms to its standard. Without some form of governing body, bar coding would not work. S UPC (Universal Product Code) with/without add-ons S EAN (European Article Numbering Code) with/without add-ons S Codabar S C11 (Code 11) S C39 (Code 39) S C93 (Code 93) S C128 (Code 128) S I 2 of 5 (Interleaved 2 of 5 Code) S S 2 of 5 (Standard 2 of 5) S Plessey S MSI (a variant of Plessey)

UPC The UPC (Universal Product Code) is the symbology used throughout the grocery and retail industries. This bar code symbology contains two pieces of numerical information encoded on the bar code, producer identification, and product identification information. The UPC symbol is 12 characters long. The first character of the UPC symbol is a number system character, such as “0” for grocery items and “3” for drug- and health-related items. The UPC symbology is for retail environments such as grocery stores, convenience stores, and general merchandise stores. Some retail items are so small that a standard UPC bar code cannot fit on the packaging. When this occurs there is a permitted shorter version of the UPC symbology, referred to as UPC-E. UPC-E is six characters long (eight including number system and check digit), approximately half the size of a standard UPC bar code. TE 2000™ VT/ANSI Terminal Emulation Programmer’s Guide

383

Page 408

Appendix B, Bar Code Symbologies

EAN EAN (European Article Numbering) symbology is similar to UPC symbology, except that it contains 13 characters and uses the first two to identify countries. The EAN symbology is used throughout most of Europe in the retail environment. Although similar to UPC symbology, the two are not interchangeable.

Codabar Codabar was for retail price-labeling systems. Today it is widely accepted by libraries, medical industries, and photo finishing services. Codabar is a discrete, self-checking code with each character represented by a stand-alone group of four bars and three intervening spaces. Four different start or stop characters get defined and designated “a”, “b”, “c”, and “d”. These start and stop characters are constructed using one wide bar and two wide spaces. A complete Codabar symbol begins with one of the start or stop characters followed by some number of data characters and ending in one of the start or stop characters. Any of the start or stop characters may be used on either end of the symbol. It is possible to use the 16 unique start or stop combinations to identify label type or other information. Since Codabar is variable-length, discrete, and self-checking, it is a versatile symbology. The width of space between characters is not critical and may vary significantly within the same symbol. The character set consists of “0” through “9”, “-”, “$”, “:”, “/”, “.”, and “+”. The specific dimensions for bars and spaces in Codabar optimize performance of certain early printing and reading equipment. Codabar has 18 different dimensions for bar and space widths. So many different dimensions often result in labels printed out of specification and cause Codabar printing equipment to be more expensive.

Code 11 Code 11 satisfies the requirements for a very high density, discrete numeric bar code. The name Code 11 derives from 11 different data characters that can be represented, in addition to a start or stop character. The character set includes the 10 digits and the dash symbol. Each character is represented by a stand-alone group of three bars and two intervening spaces. Although Code 11 is discrete, it is not self-checking. A single printing defect can transpose one character into another valid character. One or two check digits obtain data security. The specifications for Code 11 suggest that this code should have a narrow element width of 7.5 mils. This results in an information density of 15 characters per inch.

384

TE 2000™ VT/ANSI Terminal Emulation Programmer’s Guide

Page 409

Appendix B, Bar Code Symbologies

Code 39 Code 39 (C39) is the most widely used symbology among the industrial bar codes. Most major companies, trade associations, and the federal government find this code to fit their needs. The main feature of this symbology is the ability to encode messages using the full alphanumeric character set, seven special characters, and ASCII characters. Programming for this symbology can be for any length that the application requires. The application program handles symbology that is at least one character but no more than 32 characters in length. When programming the computer for Code 39, it is important to set the symbology limit as close as possible (minimum and maximum bar code lengths being scanned). Doing so keeps the computer bar code processing time to a minimum and conserves battery power. Bar code readers can respond to Uniform Symbology Specification symbols in non-standard ways for particular applications. These methods are not for general applications, because of the extra programming required. Code 39 Full ASCII is one example of non-standard code.

Encoded Code 39 (Concatenation) If the first data character of a symbol is a space, the reader may be programmed to append the information contained in the remainder of the symbol to a storage buffer. This operation continues for all successive symbols that contain a leading space, with messages being added to the end of previously stored ones. When a message is read which does not contain a leading space, the contents are appended to the buffer, the entire buffer is transmitted, and the buffer is cleared.

Encoded Code 39 (Full ASCII) If the bar code reader is programmed for the task, the entire ASCII character set (128 characters) could be coded. This is done using two character sequences made up of one of the symbols (“$”,“.”,“%”,“/”) followed by one of the 26 letters.

TE 2000™ VT/ANSI Terminal Emulation Programmer’s Guide

385

Page 410

Appendix B, Bar Code Symbologies

Code 93 The introduction of Code 93 provided a higher density alphanumeric symbology designed to supplement Code 39. The set of data characters in Code 93 is identical with that offered with Code 39. Each character consists of nine modules arranged into three bars and three spaces. Code 93 uses 48 of the 56 possible combinations. One of these characters, represented by a square, is reserved for a start or stop character, four are used for control characters, and the remaining 43 data characters coincide with the Code 39 character set. An additional single module termination bar after the stop character concludes the final space. Code 93 is a variable length, continuous code that is not self-checking. Bar and spaces widths may be one, two, three, or four modules wide. Its structure uses edge-to-similar-edge decoding. This makes the bar code immune to uniform ink spread, which allows liberal bar width tolerances. Code 93 uses two check characters. Its supporters believes this makes it the highest density alphanumeric bar code. The dual check digit scheme provides for high data integrity. All substitution errors in a single character are detected for any message length.

Code 128 Code 128 (C128) is one of the newest symbologies used by the retail and manufacturing industries. It responds to the need for a compact alphanumeric bar code symbol that could encode complex product identification. The fundamental requirement called for a symbology capable of being printed by existing data processing printers (primarily dot-matrix printers) that produce daily, work-in-progress, job, and product traceability documents. The ability to print identification messages between 10 and 32 characters long, on existing forms and labels deemed an important requirement. Code 128 uniquely addresses this need as the most compact, complete, alphanumeric symbology available. Additionally, the Code 128 design with geometric features, improves scanner read performance, does self-checking, and provides data message management function codes. Code 128 encodes the complete set of 128 ASCII characters without adding extra symbol elements. Code 128 contains a variable-length symbology and the ability to link one message to another for composite message transmission. Code 128, being a double-density field, provides two numeric values in a single character. Code 128 follows the general bar code format of start zone, data, check digit, stop code, and quiet zone. An absolute minimum bar or space dimension of nine mils (0.010 inch minimum nominal ± 0.001 inch tolerance) must be maintained. Characters in Code 128 consist of three bars and three spaces so that the total character set includes three different start characters and a stop character.

386

TE 2000™ VT/ANSI Terminal Emulation Programmer’s Guide

Page 411

Appendix B, Bar Code Symbologies

UCC/EAN-128 Shipping Container Labeling is a versatile tool that can ease movement of products and information. The Shipping Container Labeling bar code can take any form and usually has meaning only within the company or facility where applied. Because this random data can get mistaken later for an industry standard code format, the UCC and EAN chose a symbology uniquely identified from these other bar codes. This standard is for maximum flexibility, to handle the diversity of distribution in global markets by cost efficiency. The UCC/EAN-128 Container Labeling specification calls for a FUNC1 to immediately follow the bar code’s start character. FUNC1 also follows any variable-length application field. The specification also calls for the computer to send “]C1” for the first FUNC1. The specification requires that the computer send a “<GS>” (hex 1D) for subsequent FUNC1 codes in the bar code. Because “<GS>” is not compatible with computer emulation data streams, the Uniform Code Council has been asked to change the specification. This change is made to send the same three character sequence “]C1” to identify the embedded FUNC1 codes. This implementation should provide for clean application coding by identifying the same sequences for the same scanned codes. If the communication of Norand bar code types is enabled, the Shipping Container Label codes precede with a “J”. These strings will appear on the computer display. The application may have to allow for strings longer than 48 characters (maximum length indicated in the specification). Actual length variance depends on the number of variable-length data fields. Allowing for 60 characters should be sufficient. Within the Code 128 specification, the computer can link bar codes together. If this is to happen, allow for more characters (computer limit is 100 characters). The Application Identifier Standard, that is part of the UCC/EAN Shipping Label concept, complements, rather than replaces, other UCC/EAN standards. Most UCC/EAN standards primarily identify products. Several industries expressed the need to standardize more than product identification. The UCC/EAN Code 128 Application Identifier Standard supplies this tool. The standard adds versatility for inter-enterprise exchanges of perishability dating, lot and batch identification, units of use measure, location codes, and several other information attributes. For more detailed information on Code 128 UCC/EAN Shipping Label bar code and Application Identifier Standard, refer to the UCC/EAN-128 Application Identifier Standard specification.

TE 2000™ VT/ANSI Terminal Emulation Programmer’s Guide

387

Page 412

Appendix B, Bar Code Symbologies

I 2 of 5 (Interleaved) I 2 of 5 (Interleaved 2 of 5 Code) is an all-numeric symbology, widely used for warehouse and heavy industrial applications. Its use has been particularly prevalent in the automobile industry. The I 2 of 5 symbology can be placed on smaller labels than what the standard UPC symbology requires. I 2 of 5 also provides a little more flexibility on the type of material it can print on. Interleaved 2 of 5 Code has its name because of the way the bar code is configured. I 2 of 5 bars and spaces both carry information. The bars represent the odd number position digits, while spaces represent the even number position digits. The two characters are interleaved as one. Messages encoded with this symbology have to use an even number of characters since two numeric characters always get interleaved together.

S 2 of 5 (Standard 2 of 5) The code S 2 of 5 (Standard 2 of 5 Code) is designed primarily for: S Warehouse inventory handling S Identification of photo finishing envelopes S Airline tickets S Baggage and cargo handling The code S 2 of 5 is simple and straightforward. All information is contained in the widths of the bars, with the spaces serving only to separate the individual bars. Bars can either be wide or narrow, and the wide bars are usually three times the widths of the narrow bars. Spaces may be any reasonable width but are typically equal to the narrow bars. Narrow bars are identified as zero bits and wide bars as one bits. Remember the code structure by associating the bar positions from left to right with weighting factors 1, 2, 4, 7, and parity. Exceptions to this rule are zero, start, and stop. This code is a discrete code, since the white spaces between the characters are not part of the code. Because the white spaces carry no information, their dimensions are not critical. The S 2 of 5 code is self-checking, meaning a scanner passing through a printing void would detect the proper ratio of wide bars to total bars. When the scanner spots an error, a non-read will occur.

388

TE 2000™ VT/ANSI Terminal Emulation Programmer’s Guide

Page 413

Appendix B, Bar Code Symbologies

Plessey Plessey finds its origin in the pulse width modulated (PWM) code developed in England. It is widely used for shelf markings in grocery stores. Pulse width modulated codes represent each bit of information by a bar and space pair. A zero bit consists of a narrow bar followed by a wide space, while a one bit consists of a wide bar followed by a narrow space. It is mainly a numeric symbology (0–9) with six extra characters available for assigning any symbol or letter desired. Plessey codes are not self-checking and employ a variety of check characters. Plessey employs a polynomial-based Cyclic Redundancy Check (CRC). For start and stop characters, Plessey employs a 1101 and previously used a 0101. This symbology is very limited about what information can be encoded. It is not considered for new applications.

MSI Code (Variant of Plessey) In addition to Plessey characteristics, the MSI Code employs a Modulus 10 Check. For start and stop checks, MSI employs a single bit pair of 1 as a start symbol and a single bit pair of 0 as a stop symbol. MSI reverses the 1-2-4-8 BCD pattern for bit pair weighting to 8-6-2-1.

TE 2000™ VT/ANSI Terminal Emulation Programmer’s Guide

389

Page 414

Appendix B, Bar Code Symbologies

390

TE 2000™ VT/ANSI Terminal Emulation Programmer’s Guide