Page 209
Chapter 4, Using the Terminal Emulation Menus
3) Memory View (6400, 5055, 17XX, 11XX) This menu is reserved for engineering test and evaluation. Press [F1] to exit out of this test, [F2] to view the heap, [F3] to view the far heap, or [F4] to do a memory dump. Memory View F1 - Exit F2 - Heap F3 - Far Heap F4 - Memory Dump Address: xxxxxx
4) Packet Driver (6400, 5055, 59XX, 17XX, 11XX) 4) Packet Driver tests accuracy of data transmissions to and from the terminal. Packet Driver 1) 2) 3) Packet Stats 4) Histogram 5) 6)
3) Packet Stats is for 6400, 5055, 59XX, 17XX, 11XX
3) Packet Stats (Statistics) (6400, 5055, 59XX, 17XX, 11XX) Shows the number of packets sent and received, number of errors, and number of packets dropped.
Receive Statistics Pkt xxx Chr xxx Err xxx Lost xxx
Transmit Statistics Pkt xxx Chr xxx Err xxx * See Text ’Histogram Options’ Transaction Statistics Qty xxx Sec xxx Qty/Min xxx Ops xxx
TE 2000™ VT/ANSI Terminal Emulation Programmer’s Guide
RTC Statistics
185
Page 210
Chapter 4, Using the Terminal Emulation Menus
4) Histogram An Intermec engineer may ask you to access this menu if your terminal has problems. From this menu you can provide the Intermec system engineer with vital information about your unit. The actual menus are not shown in this manual, however some of the general terminology is shown below. Several of the menu options, such as “Clear. . ., ” are password-protected and are only accessible if the engineer provides you with the correct password. An Intermec system engineer will work with you on these selections. Terminology you might see: S avg tx time
S send retries
S avg trans time
S rcv retries
S ptt (push-to-talk) count
S reset count
S addrs on list
S interval time
S poll no data
S time bucket #
Histogram 1) Start 2) Stop 3) View
5) Numbers (2415, 2425, 2435A, 2455, 2475, 248X, 6400, 5020, 5055, 59XX, 17XX, 11XX) 5) Numbers checks the operation of the terminal microprocessor. During the test, the terminal display is filled with hexadecimal numbers that move across the screen horizontally and scroll vertically. Character movement indicates that the processor is still running. To stop the test, press any key. This test is helpful in detecting lockups during severe operating conditions.
6) Timed Numbers (2415, 2425, 2435A, 2455, 2475, 248X, 6400, 5020, 5055, 59XX, 17XX, 11XX) 6) Timed Numbers does the same thing as 5) Numbers except that it keeps track of the time in seconds that it took to run the test. The test terminates when a key is pressed or when 65,536 numbers are displayed.
186
TE 2000™ VT/ANSI Terminal Emulation Programmer’s Guide
Page 211
Chapter 4, Using the Terminal Emulation Menus
5) Version Info (Information) 5) Version Info shows the name, version, and release date of the program you are using, the version of the radio driver, and the MAC address of the 6400, 5055, or 11XX Terminal. See Chapter 1, “Getting Started,” for TE program names.
MLID Name and MLID ver are for 6400, 5055
Version Info Firmware <TE Program Name> Version <number> Date <ddmmyy> MLID Name ZZZZZZ MLID ver xx.xx (mac address)
6) Exit Menus Note: If direct connect is used, the terminal may reboot upon exiting the TE configuration menu. Use 6) Exit Menus to exit the TE configuration menus. If you changed any parameter settings, the terminal displays the following when you exit the menus. Save Parms Enter ’Y’ to save parms
If you press [Y] (“yes”), you are prompted for a password. “cr52401” is the default password. Save Parms Enter Password > .......
TE 2000™ VT/ANSI Terminal Emulation Programmer’s Guide
187
Page 212
Chapter 4, Using the Terminal Emulation Menus
After you enter the correct password, your settings are saved to Flash, and the terminal may reboot. (Some changes automatically reboot the terminal.) If you press a key other than [Y], you exit the menus and the new settings are not saved. In this case, the new settings are lost when you reboot your terminal. When you exit the TE configuration menus, the following information appears: <TE program name> <version> Session: <number> Host: <data stream>
7) More (Main Menu 2) Select 7) More to open the Main Menu 2 screen. Main Menu 2 1) Keyboard Opts 2) Save Parms 3) Cloning Opts 4) Session Menu
3) Cloning Opts is for 59XX, 17XX, 11XX 4) Session Menu is for 2415 (WTP), 2425 (WTP), 2435A (WTP), 2455 (WTP), 2475 (WTP), 248X (WTP), 6400, 5020 (TCP/IP), 5055, 17XX, 11XX, 700 Series, CK30, CK31, CV60
1) Keyboard Opts Use 1) Keyboard Opts > 1) Type-Ahead to key in information when the terminal cannot immediately send data to the host computer. 1) Type-Ahead enters information when the terminal cannot immediately send data to the host. Keyboard Opts 1) Type - Ahead
This stores keystrokes after the Input Inhibited annunciator (below) appears on the status line, and then saves them for the next input field. Type-ahead is enabled by default.
X 188
Input Inhibited annunciator
TE 2000™ VT/ANSI Terminal Emulation Programmer’s Guide
Page 213
Chapter 4, Using the Terminal Emulation Menus
2) Save Parms (Parameters) Use 2) Save Parms to retain the changes made to TE configuration settings. When saved, changes become the default settings for the terminal. Note: Use this option sparingly. Each time it is used, additional memory space is occupied because previously saved changes are not erased. The memory cannot be recovered on 59XX, 17XX, and 11XX Terminals without reflashing. Ensure that the parameters are correct before choosing 2) Save Parms. When selected, you are prompted to enter a seven-character password. The default password is “cr52401;” which you can alter with a custom configuration to be a string of 1 to 10 characters long. After you enter the correct password, your changes are written to Flash. If an error is made or the incorrect password is entered, the terminal will return to 2) Save Parms screen without saving your entries. Save Parms
Save Parms
Enter Password: > . . . . . . .
Working Please Wait ........
3) Cloning Opts (59XX, 17XX, 11XX) Note: 3) Cloning Opts is disabled for 59XX Terminals. These options transfer the application program or parameter settings from one terminal to another. All three choices are password-protected, with “cr52401” as the default password. To perform this function you need a cloning cable and both terminals set for cloning. Cloning Opts 1) Clone Prgms 2) Clone Parms 3) Receive Parms
1 Connect the two terminals together using the cloning cable. Use cable P/N: 216-911-001, with radio terminals containing 12-volt Flash (see illustration on page 190) for connecting with the NC1100 Power Supply and Charger (see illustration on the next page). 2 Plug the NC1100 Power Supply and Charger into an ac outlet. Use cable P/N: 216-909-001, with radio terminals containing 5-volt Flash. You may use the 12-volt Flash cable, but this is optional. TE 2000™ VT/ANSI Terminal Emulation Programmer’s Guide
189
Page 214
Chapter 4, Using the Terminal Emulation Menus
3 Turn on the source terminal from which to copy the application. 4 Press 3) Cloning Opts, then 1) Clone Prgms. 5 Key in the password. 6 Hold down the [I] key while turning on the terminal receiving the program. The application program will copy into the receiving terminal. To Source Terminal
To NC1100 Charger
To Receiving Terminal
12-Volt Cable (P/N: 216-911-001)
5-Volt Cable (P/N: 216-909-001)
To Source Terminal
To Receiving Terminal
This illustrations shows the FLASH cloning cable connections as they pertain to step 1 on the previous page.
To clone parameters from one terminal to another, first ensure the desired parameters are already set in the terminal you wish to transfer from. Then: 1 Connect the terminals together using the cloning cable. Data Terminals with 12-volt FLASH use P/N: 216-911-001. Data Terminals with 5-volt FLASH use P/N: 216-909-001. 2 With both terminals turned ON, press 3) Cloning Opts on both. 3 On the source terminal (the terminal with the parameters from which to copy), press 2) Clone Parms. 4 On the receiving terminal, press 3) Receive Parms. If using the cable that requires the NC1100 Power Supply and Charger, make sure it is connected to the NC1100 Power Supply and Charger.
Follow the alignment from the NC1100 power supply to the cloning cable connection. This illustration pertains to step 1 on the previous page.
190
TE 2000™ VT/ANSI Terminal Emulation Programmer’s Guide
Page 215
Chapter 4, Using the Terminal Emulation Menus
Note: For 700 Series, CK31, and CV60 Terminals, the following menu appears after double-tapping the upper-left corner of your display.
4) Session Menu (2415, 2425, 2435A, 2455, 2475, 248X with WTP, 700 Series, CK30, CK31, CV60 with TCP/IP, 6400, 5020, 5055, 59XX, 17XX, 11XX) Note: 2415, 2425, 2435A, 2455, 2475, 248X, 700 Series, CK30, CK31, and CV60 Terminals with UDP Plus do not allow multiple sessions. 4) Session Menu defines different host communication sessions, designates a “hot key” that switches quickly between sessions, and assigns sessions customizable host names (or, friendly names).
1) Switch Use this option to change the current session. Be sure to identify (or designate) the current (or intended) session before setting parameters.
2) Set Hot Key (available on units supporting session-switching) Displays the current hot key. Use the up and down keys to view the available choices. Press [Enter] to designate a key for the hot key.
3) Copy Setup (password -protected) For 2415, 2425, 2435A, 2455, 2475, 248X, 6400, 5020, 5055, 59XX, 17XX, 11XX Terminals, this copies parameters from the background session to the current session. For 700 Series, CK30, CK31, CV60 Terminals, this copies parameters from the current session to the session chosen. The copied data is grayed out and the chosen session is outlined with a box, like in this example:
Sample screen from CV60 Terminal
4) Session Name (700 Series, CK30, CK31, CV60) Use this to assign customizable host names (or, friendly names) to each session. Enter a name for Session 1, then press [Enter] to return to the Session Menu. You may use up to 64 characters for each name.
Sample screen from CV60 Terminal
TE 2000™ VT/ANSI Terminal Emulation Programmer’s Guide
191
Page 216
Chapter 4, Using the Terminal Emulation Menus
To assign a name to another session, press [1] to switch to that session, return to the Session Menu, then press [4] to assign a name to that session. Session Menu 1) Switch 2) Set Hot Key 3) Copy Setup 4) Session Name
For 2415, 2425, 2435A, 2455, 2475, 248X, 6400, 5020, 5055, 59XX, 17XX, 11XX, CK31 Select Session Use Cursor Up And Down Keys To Adjust
4) Session Name is for 700 Series, CK30, CK31, CV60
For 700 Series, CK30, CK31, CV60
[1]
1
[1]
2
Session: X <datastream> Host: xxxx
Set Hot Key Use Cursor Up And Down Keys To Adjust
3
[2]
1
[3]
< xx >
3
Session 1 [4] Session Name
1 Cursor left or right, then press [Enter]; or press a number to pick a session. 2 The IP address or DNS name assigned to the selected session. 3 The terminal emulation assigned to the selected session.
Restarting Terminal Emulation Note: The reset firmware bar code is not supported on the 5020, 59XX, 17XX, 11XX, 700 Series, CK30, CK31, or CV60 Terminals. Instead, do the cold-start function to exit the TE application and return to the Windows CE main menu. You need to restart your TE application if you are having problems or if you want to reconnect to the host with a new configuration. Restarting your TE application also clears the auto-login information, preventing another user from establishing a TE session using your login information.
192
TE 2000™ VT/ANSI Terminal Emulation Programmer’s Guide
Page 217
Chapter 4, Using the Terminal Emulation Menus
You can restart your TE application by either scanning the following Reset Firmware bar code or by using the 6) Cold Start option in the TE configuration Main Menu. Both methods reset all terminal firmware and the application and run the application in a new session. Reset Firmware
*/M.* *-.*
The terminal restarts your TE 2000 application using the configuration saved in CONFIG.DAT, or follow this procedure: 1 At the third initialization screen or anywhere in a TE 2000 session, access the Main Menu by pressing the appropriate key combination (see page 4).
COPR. 1991-2005 INTERMEC. ALL RIGHTS RESERVED V<version number> <release date>
TE 2000(TM)
<program name> <version> Host: <host name> <emulation type>
<program name> <version> <emulation type> Host: <host name>
<program name> <version> Session: <current session number> <session name> <emulation type> Host: <host name> <device name>
For Version 7.26 or greater
For Version 8.00 or greater
Note: If not connected to the Intermec Application Server or host computer, or have problems accessing the Main Menu, reset the terminal to go to the initialization screens. 2 Select 1) Set-up Parms, then enter the “cr52401” password. Do not press Enter. 3 Select 6) Cold Start, press [Y] when prompted to restart, then start using the application or change the TE configuration. Note: See the terminal’s user guide or manual for information on how to recover from a lock-up condition. TE 2000™ VT/ANSI Terminal Emulation Programmer’s Guide
193
Page 218
Chapter 4, Using the Terminal Emulation Menus
2415, 2425, 2435A, 2455, 2475, 248X Terminals Note: The following instructions are specific for 2415, 2425, 2435A, 2455, 2475, and 248X Terminals. You can configure several options for VT/ANSI TE on your Trakker AntaresR Terminal, including: S UDP Plus or TCP/IP communications S VT/ANSI options S Main Menu password Note: You can also set the password for UDP Plus Terminals from the Intermec Application Server. You can access the TE configuration menus when the initialization screens appear or once you establish a TE session. The TE initialization screens appear each time you reboot the terminal or restart your application. Note: Some parameters for 2415, 2425, 2435A, 2455, 2475, and 248X Terminals are available through the TRAKKER Antares 2400 Menu System. They are not reproduced in the TE configuration menus. See the terminal’s user manual for information about the menu system.
6400 Computer The terminal emulation screens support terminals running Intermec Terminal Emulation or 6400 TCP/IP software. This describes the menus used to set operating and scanning parameters for the hand-held computer. Additional information can be found in the technical overview for your emulation program. Note: Ensure there is a fully-charged battery pack in the 6400 Computer before setting parameters.
Opening the Main Menu The Main Menu is the first screen displayed when you open the computer menus. All other menus are accessed from the Main Menu. To open the Main Menu, press [Yellow], then [Blue]. Briefly, these keys generally operate as: S [Blue] for functions labeled by blue legends above the keys. S [Green] for functions labeled by green legends above the keys. S [Yellow] for functions labeled by yellow legends above the keys. S [Blue], then [Green] shift is CAPS LOCK. S [Blue], then [Yellow] shift is Alphabetic Lock (6400 Computer 41-key units). S [Yellow], then [Blue] is Terminal Emulation menus; your particular emulation software probably treat the keys for contrast control, backlighting and other functions differently.
194
TE 2000™ VT/ANSI Terminal Emulation Programmer’s Guide