Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 6 of 18

TRAKKER Antares Terminal Emulation User's Guide, pages 51 to 60

Pages 51 to 60 of 176

The original document is the PDF (989 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Intermec 2425, Intermec 2480, Intermec 2486, Intermec 2481 and Intermec 2485

Page 51

Nugg

Co de 39 Using Terminal Emulation Applications

2

Use the paging key sequences and bar code labels listed in the next table to move the viewport.

Paging Keys to Move the Viewport To Enter Home

End

Page up

Page down

Page right

Page left

Insert

Press These Keys T2425/T2455/T248X

Or Scan This Bar Code

Description

*/EHOME*

Moves the viewport to the top left corner of the TE screen.

*%HOME*

*/EEND* *%END*

*/EPGUP*

Moves the viewport up one page.

*%PGUP*

*/EPGDN*

Moves the viewport down one page.

*%PGDN*

*/EPGRT*

Moves the viewport right one page.

*%PGRT*

*/EPGLT*

Moves the viewport left one page.

*%PGLT*

*/EINS* *%INS*

Delete

Moves the viewport to the end of the last line displayed on the TE screen.

Each character you type is inserted after the cursor until you exit Insert mode by pressing again.

Normally, you type text in Overwrite mode. Characters are typed over the existing characters on the screen.

*/EDEL*

Deletes or erases the character displayed above the cursor.

*%DEL*

Note: There are alternate viewport commands that work on both the TRAKKER Antares terminals and JANUS devices. For help, see “Viewport Commands Compatible With JANUS Devices” in Appendix A.

2-29

Page 52

This page is a scan with no text; see it in the PDF.

Page 53

3 Customizing Your Configuration

Page 54

This page is a scan with no text; see it in the PDF.

Page 55

Co de 39NG Customizing Your Configuration

3

This chapter explains how to configure the terminal emulation applications.

Configuring 3270 or 5250 Terminal Emulation Parameters You can configure several parameters for 3270 and 5250 TE on the TRAKKER Antares terminal. These are the TE parameters you can configure: •

Terminal

•

Communications (for UDP Plus network only)

•

Viewport

Important: Do NOT use the TE Configuration menu to configure terminal emulation on your T2480 or T2485. The TE Configuration menu screens do not fit in the screen window area and you cannot read all the options. If you do get into the menu, try pressing to exit. For help configuring TE on the T2480 or T2485, see “Configuring Terminal Emulation on the T2480 and T2485” later in this chapter.

]

Configuring Terminal Emulation Screens and Options You can access the TE Configuration menu when the TE welcome screen appears or once a TE session is established. The TE welcome screen appears each time you reboot the terminal or restart your application. Use this procedure to configure your 3270 or 5250 TE program. Note: You cannot enter the TE Configuration menu when the terminal is trying to connect to the DCS 300, Model 200 Controller, or host. To configure 3270 or 5250 TE options 1. At the TE welcome screen or anywhere in a TE session, press Terminal Emulation menu. TE welcome screen

Intermec TRAKKER Antares 3270 Terminal Emulation Version 04.1 to access the

TE session screen Sign on User.............. Password.......... Program/procedure. Menu.............. Current Library...

TNAPP

F TE24XXUG.031

3-3

Page 56

TRAKKER Antares Terminal Emulation User’s Guide Co de 39NG

Note: If you are not connected to the host or DCS 300 or controller or have problems accessing the TE Configuration menu, reset your terminal to get to the TE welcome screen. For help, see Chapter 6, “Troubleshooting.” The Terminal Emulation menu appears.

TERMINAL

EMULATION

Configure TE Set Password Exit TE Configure TE

_` Select item [Enter] Next [F1] Help [Esc] Exit TE24XXUG.004

Note: If the Terminal Emulation menu does not appear, you need to reset the terminal firmware for the TE keypad or keyboard. For help resetting the keypad or keyboard, see “Problems Accessing the TE Configuration Menu” in Chapter 6. 2. Choose Configure TE and press UDP Plus Network Terminal TE

CONFIGURATION

Terminal Communications Viewport Exit Config Help

_` Select item [Enter] Next [F1] Help [Esc] Exit TE24XXUG.005

The TE Configuration menu appears. TCP/IP Network Terminal TE

CONFIGURATION

Terminal Viewport Exit Config Help

_` Select item [Enter] Next [F1] Help [Esc] Exit

TE24XXUG.030

Note: If you are using the 3270 or 5250 TE application for a TCP/IP direct connect network, you do not need to set communications parameters in the TE Configuration menu.

: V

3. Press or to highlight the option you want to configure and press . The Terminal, Communications, and Viewport screens are defined next. To exit, see “Exiting the TE Configuration Menu” later in this section.

3-4

Page 57

Co de 39NG Customizing Your Configuration

3

Definitions for the TE Configuration Screens TE Configuration Screen

Description The Terminal screen contains these options:

TERMINAL Text Size Regular Height Auto Field Advance Enable

OK

Text Size Selects the size of text the terminal displays on the terminal screen. Options are regular height (normal characters) and double height (double high text). Auto Field Advance (5250 only) Enables or disables the auto field advance option. Auto field advance enabled is the default. For more information about using auto-advance, see “Auto-Advancing Through Fields on 5250 Terminal Emulation Screens” in Chapter 2.

CANCEL TE24XXUG.006

COMMUNICATIONS Upline Protocol TELNET Host Name IMSYSD

OK

CANCEL TE24XXUG.003

The Communications screen (UDP Plus network only) contains these options: Upline Protocol Select either Telnet or SNA protocol. SNA forces the TRAKKER Antares terminal to use the SNA 5250 Terminal Session Manager (TSM) on the DCS 300 or Model 200 Controller for communicating with the host. Telnet forces the terminal to use the Telnet TSM in the DCS 300 or controller to communicate with the host. Both TSM components reside on the DCS 300 or controller and are transparent to the terminal emulation user. Host Name Enter the name of the host to which you want the terminal to connect. You can enter a host name that is up to 15 characters long. The name must match a host name in the list of available hosts defined on the DCS 300 or Model 200 Controller. Note: If you have linked a terminal with a host name on the DCS 300 or Model 200 Controller, you do not need to enter a host name in this screen. If you have not linked a terminal with a host name on the DCS 300 or controller, you must enter a host name for this parameter.

3-5

Page 58

TRAKKER Antares Terminal Emulation User’s Guide Co de 39NG

Definitions for the TE Configuration Screens (continued) TE Configuration Screen

Description The Viewport screen contains these options:

VIEWPORT Viewport Mode Follow Side Boundary 1 Side Jump 10 Vertical Boundary 1 Vertical Jump 8 OK

CANCEL TE34XXUG.008

Viewport Mode

Select one of these viewport movement modes:

•

Follow Enables viewport Follow Cursor mode.

•

Center Enables viewport Center mode. The viewport always centers around the cursor.

•

Manual Disables viewport movement. You must manually move the cursor to each field in the screen.

You can set these parameters for Follow Cursor mode only: Side Boundary The viewport moves when the cursor is this number of characters (1 to 10) from the right or left side boundary. Side Jump The number of characters (1 to 10) the viewport moves right or left when you reach a horizontal boundary. Vertical Boundary The viewport moves when the cursor is this number of characters (1 to 10) from the top or bottom boundary. Vertical Jump The number of characters (1 to 10) the terminal moves up or down when you reach a vertical boundary.

3-6

Page 59

Co de 39NG Customizing Your Configuration

3

Exiting the TE Configuration Menu After entering all configuration parameters, you want to save the new configuration and exit the TE Configuration menu. To exit the TE Configuration menu 1. From the TE Configuration menu, choose Exit Config and press new configuration screen appears.

Save

The Save new configuration?

Yes

No

CANCEL

TE24XXUG.009

2. Choose Yes and press if you want to save the TE configuration. Your terminal saves the configuration options to flash memory and the sign-on or TE screen appears.

Choose No and press if you do not want to save the TE configuration. You exit the TE Configuration menu without saving any changes and the sign-on or TE screen appears.

Choose Cancel and press to return to the TE Configuration menu. You can continue making changes to the TE configuration. If you change the communications parameters during TE startup, the new parameters will start when you exit the TE Configuration menu. If you already have a session running and change any communications parameters, you must restart your TE application for the changes to take effect. For help, see “Restarting Terminal Emulation” later in this chapter.

3-7

Page 60

TRAKKER Antares Terminal Emulation User’s Guide Co de 39NG

Configuring VT/ANSI Terminal Emulation Parameters You can configure several parameters for VT/ANSI TE on the TRAKKER Antares terminal. These are the TE parameters you can configure: •

Terminal

•

Communications (UDP Plus network only)

•

Viewport

Important: Do NOT use the TE Configuration menu to configure terminal emulation on your T2480 or T2485. The TE Configuration menu screens do not fit in the screen window area and you cannot read all the options. If you do get into the menu, try pressing to exit. For help configuring TE on your T2480 or T2485, see “Configuring Terminal Emulation on the T2480 and T2485” later in this chapter.

]

Configuring Terminal Emulation Screens and Options You can access the TE Configuration menu when the TE welcome screen appears or once a TE session is established. The TE welcome screen appears each time you reboot the terminal or restart your application. Use this procedure to configure your VT/ANSI TE application. Note: You cannot enter the TE Configuration menu when the terminal is trying to connect to the DCS 300, Model 200 Controller, or host. To configure VT/ANSI TE options 1. At the TE welcome screen or anywhere in a TE session, press Terminal Emulation menu. TE welcome screen to access the

TE session screen

* Intermec TRAKKER Antares VT/ANSI Terminal Emulation Version 04.1

<login:

TE24XXUG.029

3-8