The text of a manual · part 13 of 18
TRAKKER Antares Terminal Emulation User's Guide, pages 121 to 130
Pages 121 to 130 of 176
The original document is the PDF (989 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 2425, Intermec 2480, Intermec 2486, Intermec 2481 and Intermec 2485
Page 121
Nugg
VT100/220/320 and ANSI Commands Co de 39
5
Additional VT/ANSI Functions Function Key
Description
T248X)
Toggles the terminal between Application mode and Numeric Keypad mode.
- (T2425, T2455, and 9 (T2425, T2455, and
Transmits the Answerback field to the host computer.
T248X)
(T2425) or b (T2455 and T248X)
Accesses the TE Configuration menu. You can access the menu at any time during your terminal emulation session or at the TE welcome screen. You cannot enter the TE Configuration menu when the terminal is trying to connect to the DCS 300, Model 200 Controller, or host.
- (T2425) or
[ (T2455 and T248X)
Changes the Input mode to Line mode.
(T2425) or
Changes the Input mode to Character mode.
\ (T2455 and T248X)
Note: Bar codes are not supported for these functions.
5-11
Page 122
Page 123
6 Troubleshooting
Page 124
Page 125
Nugget
Troubleshooting Co de 39
6
This chapter lists the problems you may have while using terminal emulation and gives some possible solutions. For help with problems outside of terminal emulation, see your TRAKKER Antares user’s manual.
Problems Using Terminal Emulation Applications There are two types of error messages that you may see while running the 3270, 5250, or VT/ANSI TE application on the terminal: •
Recoverable error
•
Non-recoverable error
Recoverable errors display in the status line on the bottom line of the terminal screen. If the status line option is not currently selected, the status line will appear if there is a recoverable error. A non-recoverable error appears directly on your screen and your TE session ends. You must follow the instructions on the terminal screen to continue with your session. If the DCS 300, Model 200 Controller, or host detects an error and ends the session, you will see a DCS 300 or controller or host error message on the terminal screen. Record this error message and pass it on to your network administrator or contact your local Intermec service representative. The 3270, 5250, and VT/ANSI TE applications have an error handling routine that detects local editing errors and command handling errors. If you have a problem while running your TE application, check these possible problems. Note: Many of the error messages in the next table only apply when running the 5250 TE application. Error Message or Problem
Solution
Attn Not Processed (5250 error)
The host computer was unable to process your Attention request. Press to reset the terminal and try again later.
Digit Only (5250 error)
You have entered an invalid character in a digit only (numeric) field. Reenter a valid character for this type of field.
DUP Field Required (5250 error)
You have pressed a DUP key in a field that does not have the DUP bit enabled. Enter a valid command for this type of field.
Field minus invalid (5250 error)
You have pressed the Field- key in a non-numeric field. Use the Field Exit or Field+ key.
Field not in Field Format Table (5250 error)
The cursor is not positioned correctly in a data input field. Position the cursor correctly and try again.
?
6-3
Page 126
TRAKKER Antares Terminal Emulation User’s Guide Nugget Co de 39
Problems Using Terminal Emulation Applications (continued) Error Message or Problem
Solution
FM Field Required (5250 error)
You have pressed a Field Mark key in a field that does not have the DUP bit enabled. Enter a valid command for this type of field.
Function not implemented (5250 error)
You have pressed an unsupported function key or entered an invalid key sequence. Try the function again using the correct key sequence.
Help Not Processed (5250 error)
The host computer was unable to process your Help request. Press to reset the terminal and try again.
Invalid control sequence
You have pressed an unsupported function key or entered an invalid key sequence. Reenter a valid key sequence.
Mandatory field! (5250 error)
You have attempted to bypass a mandatory data entry field using a Field+, Field-, or Field Exit key. Enter data in the field.
Monocase Only (5250 error)
You have entered an invalid character in a monocase only field. Reenter a valid character for this type of field.
No more room for insert
You have entered more characters than allowed in a field. Press reset the terminal. Enter your data again using fewer characters.
Numeric Only
You have entered an invalid character in a numeric only field. Reenter a valid character for this type of field.
Parameter error. (5250 error)
The command received from the host computer contained an invalid parameter. Try to establish a host connection later by selecting Exit Config from the TE Configuration menu.
Protected Field
You are attempting to enter data in a protected region of the screen. Press to reset the terminal.
Roll Down Not Processed (5250 error)
The host computer was unable to process your Roll Down request. Press to reset the terminal and try again.
Roll Up Not Processed (5250 error)
The host computer was unable to process your Roll Up request. Press to reset the terminal and try again.
Session ended.
This message indicates a fatal error. Record the DCS 300 or controller primary and secondary return codes and contact your network administrator. Wait a few minutes and try to connect again by selecting Exit Config from the TE Configuration menu.
6-4
?
? to
?
?
?
Page 127
Nugget
Troubleshooting Co de 39
6
Problems Using Terminal Emulation Applications (continued) Error Message or Problem
Solution
Signed Numeric Only (5250 error)
You have entered an invalid character in a signed numeric field. Reenter a valid character for this type of field.
SysRq Not Processed (5250 error)
The host computer was unable to process your System Request. Press to reset the terminal and try again.
You press a 3270 or 5250 command on the keyboard or keypad or scan in a command and the TE application does not respond.
The key mapping file does not match the TE application. From the list in Appendix A, find the correct key mapping file and download it from the DCS 300 or Model 200 Controller or from the directory where you installed the firmware upgrade. For example, if you are running the 3270 TE application, you need to download the POLX3270.MAP key mapping file. The key mapping file must be stored on drive C.
In a TCP/IP network, you turn on the terminal after it was suspended for awhile and the host has deactivated or lost your current terminal emulation session.
You need to turn off the “Keep Alive” message from the host so that the terminal emulation session is maintained while a terminal is suspended.
?
6-5
Page 128
TRAKKER Antares Terminal Emulation User’s Guide Nugget Co de 39
Problems Connecting to a Host This section explains how to respond to error messages indicating that the terminal is not communicating with the DCS 300, the Model 200 Controller, or the host. You will need to know detailed information about your network, such as the IP addresses your network uses. Error Message or Problem
Solution
Unable to connect to controller.
Make sure the terminal is correctly configured for your network. You must set the network parameters, such as Network Activate and the network IP addresses, before the terminal can communicate with the host. For help, see your TRAKKER Antares user’s manual.
Waiting for connection to controller ... Unable to establish connection to host. Restarting Terminal Emulation. Please Wait.
If the terminal and network parameters are set correctly, the terminal is running a TE application that is not compatible with your network protocol (TCP/IP or UDP Plus). To fix the problem, you need to download the TE application that matches the terminal’s protocol. Use the TRAKKER Antares 2400 Menu System to determine the network protocol and TE application loaded on your terminal. In File Manager, check the type of TE application by using the list of “Terminal Emulation Files” in Appendix A. To determine the network protocol loaded on the terminal, use the Primary Network option on the Configuration Menu. You have UDP Plus if the Primary Network screen shows Controller IP Address. Otherwise, the terminal is using the TCP/IP network protocol. For example, you have a terminal loaded with the TCP/IP network protocol and the TE application on drive C is PLX3270.BIN. You need to download the TCP3270.BIN file to the terminal and delete the UDP Plus TE application, PLX3270.BIN. You can download the TE applications from your DCS 300 or Model 200 Controller or from the directory where you installed the firmware upgrade.
To download and run a new TE application
6-6
1.
Connect the terminal to your PC, DCS 300, or Model 200 Controller.
2.
Download the application to drive C.
3.
Press System.
4.
Choose System Menu and then choose File Manager.
5.
Select drive C.
6.
Delete the incompatible TE application by highlighting the application and pressing .
7.
Highlight the TE application you downloaded and then press . The terminal boots, resets all firmware, and runs the new TE application.
T 3 , to access the TRAKKER Antares 2400 Menu
Page 129
Nugget
Troubleshooting Co de 39
6
Problems Accessing the TE Configuration Menu This section explains how to get to the TE Configuration menu and how to configure your terminal to recognize keypad or keyboard commands specific to terminal emulation. Error Message or Problem
Solution
You press to access the TE Configuration menu and nothing happens.
To access the TE Configuration menu, you must be in a TE session or at the TE welcome screen. To get to the TE welcome screen when you are not in a TE session, scan Reset Firmware and press when the TE welcome screen appears.
Reset Firmware
*-.* *-.*
If you still cannot access the TE Configuration menu, you need to configure the Keypad Type configuration command to match the TE keyboard or keypad overlay. Important: After you change the keyboard or keypad type, you must save the configuration in flash memory and boot the terminal for the change to take effect. To configure keypad or keyboard type for TE 1.
Access the TRAKKER Antares 2400 Menu System.
2.
Choose Configuration Menu.
3
Choose Terminal Menu.
4.
Choose Keypad.
5.
Under Keyboard Type, press
6.
Choose OK.
7.
Save the configuration change in flash memory and exit the menu system.
8.
Scan the Reset Firmware bar code label to boot the terminal and use the TE keyboard or keypad type.
; or W to display Terminal Emulation.