Page 361

HelvC NF

C39 VT100/220/320 and ANSI TE Command Reference

10

Program Function Keys When you press a program function key or scan its bar code, you send the data on the display to the host and the TRAKKER 2425 terminal performs the function you specified on this data. The software application you are using determines the function of each editing key. Refer to your application user’s manual for information about the editing key functions. Note: VT100 terminals only support function keys Function Key

!

! to % .

Bar Code F1

*/EF1* *%F1*

@

F2

*/EF2* *%F2*

#

F3

*/EF3* *%F3*

$

F4

*/EF4* *%F4*

%

F5

*/EF5* *%F5*

)!

F6

*/EF6* *%F6*

10-7

Page 362

TRAKKER Antares 2425 Hand-Held Terminal User’s Manual HelvC NugFont

Program Function Keys (continued) Function Key

)@

Bar Code F7

*/EF7* *%F7*

)#

F8

*/EF8* *%F8*

)$

F9

*/EF9* *%F9*

)%

F10

*/EF10* *%F10*

(A

F11

*/EF11* *%F11*

(B

F12

*/EF12* *%F12*

(C

F13

*/EF13* *%F13*

10-8

Co d e 39

Page 363

HelvC NF

C39 VT100/220/320 and ANSI TE Command Reference

10

Program Function Keys (continued) Function Key

(D

Bar Code F14

*/EF14* *%F14*

(E

F15

*/EF15* *%F15*

(F

F16

*/EF16* *%F16*

(G

F17

*/EF17* *%F17*

(H

F18

*/EF18* *%F18*

(I

F19

*/EF19* *%F19*

(J

F20

*/EF20* *%F20*

10-9

Page 364

TRAKKER Antares 2425 Hand-Held Terminal User’s Manual HelvC NugFont

Co d e 39

Additional Functions You can use the key sequences and bar codes shown next to move the viewport movement and execute additional commands on VT100/220/320 and ANSI terminals. Use these commands to move the viewport one line up, down, right, or left. When you move the viewport, the cursor does not move. To select a specific cursor key, press one of the arrows on the edges of the oval-shaped Cursor key. Keypad:

Viewport Up Viewport Down Viewport Left Viewport Right

Scan:

Viewport Up

*/EUP* *%UP*

Viewport Down

*/EDN* *%DN*

Viewport Left

*/ELF* *%LF*

Viewport Right

*/ERT* *%RT*

10-10

)[ ){ )] )}

Page 365

HelvC NF

C39 VT100/220/320 and ANSI TE Command Reference

10

Additional Functions (continued) Function Key

(! (@

(# ($

Bar Code

Description

Not supported

Accesses the TE Configuration menu. You can access the menu at any time during your terminal emulation session.

Exit TE

This command lets you exit the terminal emulation application.

*/EEXIT* *%EXIT*

Note: Do not choose to exit the terminal emulation program. If you do accidentally exit TE, you may see an error message on the status line. Clear the error and continue.

Not supported

Changes the Input mode to Line mode.

Not supported

Changes the Input mode to Character mode.

10-11

Page 366

This page is a scan with no text; see it in the PDF.

Page 367

HelvC NugFont

Co d e 39

A Terminal Specifications

Page 368

HelvC NugFont

Co d e 39

Page 369

HelvC NugFont

Co d e 39 Terminal Specifications

A

This appendix lists the terminal’s physical and environmental specifications, lists the default configuration, and provides a configuration command reference list in alphabetical order by command syntax.

Physical and Environmental Specifications You can use the tables in this section to find technical information about these features and options: • • • • • • • • • • • • •

Terminal Dimensions Power Specifications Temperature Specifications Relative Humidity Specifications Display Keypad Options Application Options Memory Radio Frequency Communications Network Support Bar Code Symbologies Scan Module Options Standard Range Scan Module Optical Parameters

Terminal Dimensions Length

10.6 in (26.5 cm)

Height

2.8 in (7.0 cm)

Width

3.2 in (8.0 cm)

Weight

27 oz (765.45 g) including the main battery and backup battery

Power Specifications Operating

Rechargeable lithium-ion battery pack (1000 to 1350 mAh available)

Memory Backup

Rechargeable NiCad 110 mAh battery

A-3

Page 370

TRAKKER Antares 2425 Hand-Held Terminal User’s Manual HelvC NugFont

Co d e 39

Temperature Specifications You need to operate and store the terminal within the temperature ranges listed in this table. Note: For information about using the terminal in cold temperature environments, see “Guidelines for Managing Batteries” in Chapter 6.

Type of Operation

Fahrenheit Temperature Range

Celsius Temperature Range

Charging the battery pack

+32°F to +104°F

0°C to +40°C

Operating the terminal

-4°F to +122°F

-20°C to +50°C

Storing the terminal -4°F to +140°F (with or without batteries installed)

-20°C to +60°C

Relative Humidity Specifications 0% to 95% noncondensing humidity

Display • CGA compatible • 16 lines x 20 columns, backlit LCD • 25 lines by 80 columns, virtual display with viewport feature

Keypad Options • Full alphanumeric keypad with 55 keys available in English • Terminal emulation keypads for IBM 3270, IBM 5250, and VTXXX/ANSI

Application Options • IBM 3270 terminal emulation • IBM 5250 terminal emulation • Screen mapping to IBM 3270 or 5250 terminals • VT100/220/320 and ANSI terminal emulation

A-4