Page 281

HelvC NugFont

Scan:

Co d e 39 Configuration Command Reference

8

To disable any of the function codes, scan one of these bar codes: Disable Function Code 1

*$+CK* *$+CK*

Disable Function Code 2

*$+CL*

*$+CL*

Disable Function Code 3

*$+CM* *$+CM*

Or:

To set one of the function codes to a character string: 1. Scan one of these bar codes: Enter Accumulate Mode / Set Function Code 1

*+/$+CK* *+/$+CK*

Enter Accumulate Mode / Set Function Code 2

*+/$+CL* *+/$+CL*

Enter Accumulate Mode / Set Function Code 3

*+/$+CM* *+/$+CM*

2. Scan any character from the “Full ASCII Bar Code Chart” in Appendix B. You can define two characters each for Function Codes 1 and 3, and four characters for Function Code 2. 3. Scan this bar code: Exit Accumulate Mode

*-/* *-/*

8-21

Page 282

TRAKKER Antares 2425 Hand-Held Terminal User’s Manual HelvC NugFont

Co d e 39

Code 93 Purpose:

Enables or disables decoding of Code 93 symbology. Code 93 is a variable length, continuous symbology that uses four element widths.

Default:

Disabled

Syntax:

CFdata Acceptable values for data are: 0 1

Scan:

Disabled Enabled

One of these bar codes: Disable Code 93

*$+CF0* *$+CF0*

Enable Code 93

*$+CF1* *$+CF1*

8-22

Page 283

HelvC NugFont

Co d e 39 Configuration Command Reference

8

Code 128 Purpose:

Enables or disables decoding of Code 128 symbology. Code 128 is a very high density alphanumeric symbology that supports the extended ASCII character set. It is a variable length, continuous code that uses multiple element widths.

Default:

Standard

Syntax:

CHdata Acceptable values for data are: 0 1 2

Scan:

Disabled Standard Code 128 UCC/EAN Code 128

One of these bar codes: Disable Code 128

*$+CH0* *$+CH0*

Enable Standard Code 128

*$+CH1* *$+CH1*

Enable UCC/EAN Code 128

*$+CH2* *$+CH2*

8-23

Page 284

TRAKKER Antares 2425 Hand-Held Terminal User’s Manual HelvC NugFont

Co d e 39

Code 128 (continued) Notes:

If you configure Standard Code 128, the terminal will not decode Function Code 1 characters in the first position of a bar code label. Any subsequent Function Code 1 characters are translated to the ASCII GS character as a separator for variable length fields. If you configure UCC/EAN Code 128, the terminal will decode a bar code label as Standard Code 128 unless one of the first two characters are a start character and a Function Code 1. In this case, the bar code label is processed as described next: 1. The Function Code 1 character is not transmitted. 2. The three symbology ID characters, ]C1, are transmitted. 3. The remaining Code 128 characters are decoded as Standard Code 128.

8-24

Page 285

HelvC NugFont

Co d e 39 Configuration Command Reference

8

Command Processing Purpose:

Command processing allows you to disable or enable reader commands. For example, you can disable the Backlight command. There are two ways to enable or disable reader commands: • Use the Command Processing configuration command described here. • Use the Reader Command Menu option in the Configuration Menu of the TRAKKER 2400 Menu System. You may want to disable reader commands to prevent a user from accidentally entering a command, or to use data that would otherwise be treated as a command. Any Code 39 or Code 93 bar code label that contains the 2 to 4-character commands listed at the end of this section is treated as a reader command unless the command is disabled. If you want to disable or enable several commands, it is easier to use the menu system. For help, see Chapter 3, “Configuring the Terminal.” For a description of each reader command that you can enable or disable with Command Processing, see Chapter 7, “Reader Command Reference.”

Default:

All reader commands enabled

Syntax:

DCdata Acceptable values for data are: 0 1 2 3 command0 command1

Disable all reader commands Enable all reader commands Disable override Enable override Disable reader command Enable reader command

The override option is a temporary setting that allows you to enable all the reader commands for as long as you need them. When you want to return to the previous configuration, you disable the override. Note: The Enable Override option is the only bar code label you can scan to enable reader commands if you have disabled all reader commands (DC0). You can also enable reader commands in the TRAKKER 2400 Menu System.

8-25

Page 286

TRAKKER Antares 2425 Hand-Held Terminal User’s Manual HelvC NugFont

Co d e 39

Command Processing (continued) Scan:

To enable all the reader commands or override the current settings, scan one of these bar codes: Disable All Reader Commands

*$+DC0*

*$+DC1*

*$+DC0*

*$+DC1*

Disable Override

Enable Override

*$+DC2* *$+DC2*

Or:

Enable All Reader Commands

*$+DC3*

*$+DC3*

To disable or enable specific reader commands, perform these steps: 1. Scan this bar code: Enter Accumulate Mode / Command Processing

*+/$+DC* *+/$+DC*

2. Scan the bar code to disable or enable one reader command. Note: If there are two bar codes for a reader command, you must scan them in order, left to right. Accumulate mode commands are separated into two bar codes so that the command can be accumulated rather than executed as a command. Backspace

*-*

*+*

*-*

*+*

Backlight

Change Configuration

*%.* *%.*

8-26

(continued)

*$+*

*$+*

Page 287

HelvC NugFont

Co d e 39 Configuration Command Reference

Clear

*-* *-*

8

(continued)

*-*

*-*

Default Configuration

*.+* *.+*

Enter Accumulate Mode

*+*

(continued)

*/*

*+*

*/*

Exit Accumulate Mode

(continued)

*-*

*/*

*-*

*/*

Reset

Scanner Trigger Off

*-.*

*/%*

*-.*

*/%*

Scanner Trigger On

Test and Service Mode

*/.*

*..-.*

*/.*

*..-.*

3. Scan one of these bar codes: Disable the Command

Enable the Command

*0*

*1*

*0*

*1*

4. Repeat Steps 2 and 3 to disable or enable another reader command. Note: You can accumulate up to 250 characters in the buffer. If the data accumulated exceeds 250 characters, you will hear an error beep and the terminal will reject the last bar code read.

8-27

Page 288

TRAKKER Antares 2425 Hand-Held Terminal User’s Manual HelvC NugFont

Co d e 39

Command Processing (continued) 5. Scan this bar code: Exit Accumulate Mode

*-/* *-/*

Or:

To disable or enable the ability to scan multiple-read labels, scan one of these bar codes: Disable Multiple-Read Labels

Enable Multiple-Read Labels

*$+DC 0*

*$+DC 1*

*$+DC 0*

8-28

*$+DC 1*

Page 289

HelvC NugFont

Co d e 39 Configuration Command Reference

8

Controller IP Address Purpose:

Defines the IP address assigned to the Model 200 Controller in your 2.4 GHz network. An IP address is a network level address you assign to each device in a TCP/IP network. The controller IP address you set on the TRAKKER 2425 terminal must match the address that is set on the controller.

Default:

0.0.0.0

Syntax:

NCn.n.n.n where each n address segment is a number from 0 to 255. The controller IP address field consists of four separate numbers, each separated by a period. Note: The network cannot be activated if the first address segment in the IP address is set to 0, 127, or a number greater than 223.

Scan:

To set the default controller IP address, scan this bar code: Default Controller IP Address

*$+NC0.0.0.0* *$+NC0.0.0.0*

Or:

To set the controller IP address: 1. Scan this bar code: Enter Accumulate Mode / Set Controller IP Address

*+/$+NC* *+/$+NC*

2. Scan a numeric value from 0 to 255 to set an n field of the controller IP address from these bar codes.

*0* *0*

*1* *1*

8-29

Page 290

TRAKKER Antares 2425 Hand-Held Terminal User’s Manual HelvC NugFont

Co d e 39

Controller IP Address (continued)

*2*

*3*

*2*

*3*

*4*

*5*

*6*

*7*

*8*

*9*

*4*

*6*

*8*

*5*

*7*

*9*

3. Scan this bar code: . (Period)

*.* *.*

4. Repeat Steps 2 and 3 to set the next two numbers in the controller IP address field. After you scan the last address segment, go to Step 5. Do not scan the period after the last address segment. 5. Scan this bar code: Exit Accumulate Mode

*-/* *-/*

8-30