This chapter is an alphabetical list of all the configuration commands supported on the terminal.
Using Configuration Commands A configuration command changes the way the terminal operates. For example, you can change the Beep Volume and make the terminal beep very loud in a noisy environment. You can execute configuration commands by: • scanning a command from a Code 39 or Code 93 bar code label. • choosing a command from the TRAKKER 2400 Menu System. • sending a command from a device on the 2.4 GHz network, such as the Model 200 Controller or a host computer. Note: If you are working in the TRAKKER 2400 Menu System, you cannot scan configuration commands. Exit the menu system to scan configuration commands. You can find the following information about each configuration command in this chapter: • Command description and purpose • Default setting • Command syntax and options • Bar code labels you can scan to set or change each command The configuration commands are listed alphabetically by command name. For a list of bar code symbology, network communications, or operations commands, use the next table, “Configuration Commands Listed by Category.” If you want to look up a command by its syntax, see the “Configuration Commands by Syntax” list in Appendix A. Note: The Code 39 bar code labels in this chapter show an asterisk (*) at the beginning and end of the human-readable interpretation to represent the start and stop codes. If you are creating your own Code 39 bar code labels, your bar code printing utility may automatically supply the asterisks as the start/stop code.
8-3
Page 264
TRAKKER Antares 2425 Hand-Held Terminal User’s Manual HelvC NugFont
Co d e 39
Configuration Commands Listed by Category This chapter lists the configuration commands in alphabetical order. Use this next list to find the configuration commands you may need to set for bar code symbologies, network communications, and operations.
Bar Code Symbologies
Operations
Codabar, 8-10
Append Time, 8-6
Code 11, 8-12
Automatic Shutoff, 8-7
Code 16K, 8-13
Beep Volume, 8-8
Code 2 of 5, 8-14
Command Processing, 8-25
Code 39, 8-16
Decode Security, 8-31
Code 49, 8-20
Display Backlight Timeout, 8-34
Code 93, 8-22
Display Contrast, 8-36
Code 128, 8-23
Keypad Caps Lock, 8-39
Interleaved 2 of 5, 8-37
Keypad Clicker, 8-40
MSI, 8-41
Postamble, 8-46
Plessey, 8-45
Preamble, 8-48
UPC/EAN, 8-70
Resume Execution, 8-50 Scan Ahead, 8-55
Network Communications Controller IP Address, 8-29 Default Router, 8-32 Network Activate, 8-43 Network Loopback, 8-44 RF Domain, 8-51 RF Security Identification, 8-52 RF Wakeup On Broadcast, 8-54 Subnet Mask, 8-62 Terminal IP Address, 8-64 UDP Port, 8-68
8-4
Scanner Mode, 8-56 Scanner Redundancy, 8-57 Scanner Selection, 8-59 Scanner Timeout, 8-60 Scanner Trigger, 8-61 Time and Date, 8-66 Time in Seconds, 8-67
Page 265
HelvC NugFont
Co d e 39 Configuration Command Reference
8
Entering Variable Data in a Configuration Command You can enter variable data for many of the configuration commands. For example, you can set a preamble that is up to 25 ASCII characters long. You need to follow these general instructions to enter variable data. To enter variable data in a configuration command 1. Scan a bar code label with this syntax: +/$+command where: +/ is the syntax for the Enter Accumulate Mode command.
$+ is the syntax for the Change Configuration command.
command is the syntax for the command you want to change.
For example, the command syntax for a preamble is ADdata. To change or set a preamble, scan this bar code: Enter Accumulate Mode / Change Configuration / Set Preamble
*+/$+AD* *+/$+AD*
2. Scan a bar code label from the “Full ASCII Bar Code Chart” in Appendix B. To set the preamble to the character T, scan this label: T
*T* *T*
Note: To use the bar code labels in Appendix B, you must configure the terminal to use Code 39 in Full ASCII mode. For help, see “Code 39” later in this chapter.
8-5
Page 266
TRAKKER Antares 2425 Hand-Held Terminal User’s Manual HelvC NugFont
Co d e 39
Entering Variable Data in a Configuration Command (continued) 3. Scan the Exit Accumulate Mode bar code label to update the terminal’s configuration: Exit Accumulate Mode
*-/* *-/*
Append Time Purpose:
Appends the time to data records that are transmitted from the terminal. You can also use the Time in Seconds command to append the time in hours and minutes only, or hours, minutes, and seconds. The time is appended to each data record in the form HH:MM:SS. For help, see “Time in Seconds” later in this chapter.
Default:
Disabled
Syntax:
DEdata Acceptable values for data are: 0 1
Scan:
Disabled Enabled
One of these bar codes: Disable Append Time
*$+DE0* *$+DE0*
Enable Append Time
*$+DE1* *$+DE1*
8-6
Page 267
HelvC NugFont
Co d e 39 Configuration Command Reference
8
Automatic Shutoff Purpose:
Defines the maximum length of time the terminal remains on when there is no activity. When you do not use the terminal for the length of time set with this command, the terminal automatically turns off as if you had pressed to turn it off.
q q to turn on the terminal, the terminal either resumes When you press exactly where it was when you turned it off, or the terminal boots and restarts your application. Resume is controlled through the Resume Execution command. For help, see “Resume Execution” later in this chapter. Power Management Tip: You should use the Automatic Shutoff feature to preserve the main battery pack’s power. Default:
0 (disabled)
Syntax:
EZdata Acceptable values for data are: 0 02-75
Scan:
Disabled (always on) Shutoff time in minutes
To disable automatic shutoff, scan this bar code: Disable Automatic Shutoff
*$+EZ0* *$+EZ0*
Or:
To set a timeout: 1. Scan this bar code: Enter Accumulate Mode / Set Automatic Shutoff
*+/$+EZ* *+/$+EZ*
8-7
Page 268
TRAKKER Antares 2425 Hand-Held Terminal User’s Manual HelvC NugFont
Co d e 39
Automatic Shutoff (continued) 2. Scan a numeric value for data from these bar codes:
*0* *0*
*2*
*1* *1*
*3*
*2*
*3*
*4*
*5*
*6*
*7*
*8*
*9*
*4*
*6*
*8*
*5*
*7*
*9*
3. Scan this bar code: Exit Accumulate Mode
*-/* *-/*
Beep Volume Purpose:
Adjusts the volume of the terminal’s audio signals. For a list of all the beep sounds and audio signals, see “Understanding the Terminal’s Audio Signals” in Chapter 2. Set the beep volume according to operator preference and work environment.
Default:
Normal
8-8
Page 269
HelvC NugFont
Syntax:
Co d e 39 Configuration Command Reference
8
BVdata Acceptable values for data are: 0 1 2 3 4 8 9
Scan:
Off Quiet Normal Loud Very loud Lower volume Raise volume
One of these bar codes: Off
*$+BV0*
Quiet
*$+BV1*
*$+BV0*
*$+BV1*
Normal
Loud
*$+BV2* *$+BV2*
*$+BV3*
*$+BV3*
Very Loud
*$+BV4* *$+BV4*
Or:
Scan one of these bar codes repeatedly to achieve the desired volume: Raise Beep Volume
Lower Beep Volume
*$+BV9*
*$+BV8*
*$+BV9*
*$+BV8*
8-9
Page 270
TRAKKER Antares 2425 Hand-Held Terminal User’s Manual HelvC NugFont
Co d e 39
Codabar Purpose:
Enables or disables decoding of Codabar symbology. Codabar is a selfchecking, discrete symbology. The American Blood Commission (ABC) Codabar requires that you retain and transmit the start/stop code digits when processing a Codabar symbol. As a result, configuration CD10 is an illegal configuration.
Default:
Disabled
Syntax:
CDdata Acceptable values for data must be two digits, corresponding to:
Scan:
Digit
Value
Description
First
0 1 2 3
Disabled ABC Standard Concatenated
Second
0 1 2
Discard Start/Stop Transmit ABCD Start/Stop Transmit DC1-DC4 Start/Stop
One of these bar codes: Disabled, Discard Start/Stop
*$+CD00*
*$+CD11*
*$+CD00*
*$+CD11*
ABC, Transmit DC1-DC4 Start/Stop
Standard, Discard Start/Stop
*$+CD12*
*$+CD20*
*$+CD12*
*$+CD20*
Standard, Transmit ABCD Start/Stop
Standard, Transmit DC1-DC4 Start/Stop
*$+CD21* *$+CD21*
8-10
ABC, Transmit ABCD Start/Stop
*$+CD22*
*$+CD22*