Trakker Antares 24XX Terminal User's Manual Addendum, with the Trakker Antares 2420 and 2425 Hand-Held Terminal User's Manual: Glossary, pages 517 to 524

Pages 517 to 524 of 558, from Trakker Antares 24XX Terminal User's Manual Addendum, with the Trakker Antares 2420 and 2425 Hand-Held Terminal User's Manual

The original document is the PDF (4.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Intermec 2420 and Intermec 2425

Page 517 read from a scan by OCR; it may hold reading errors

G

|

OSSa ry

Page 518

G-2

Page 519

Glossary

G

10BaseT, 10Base2, or 10Base5 An implementation of Ethernet IEEE (Institute of Electrical and Electronic Engineers) standards to describe the primary characteristics of the cabling system. The 10 signifies 10 Mbps. Base indicates that the type of signaling used is baseband. The T at the end means that twisted-pair cable is used. The number (2, 5, or 10) at the end indicates the maximum cable length in hundreds of meters. 3270 or 5250 terminal emulation An application that allows Intermec devices to emulate an IBM 3270 or 5250 terminal. access point A wireless bridge that allows RF packets to go from the Intermec 2.4 GHz RF network to the Ethernet or token ring network. Accumulate mode Operating mode in which the terminal stores scanned information in the terminal’s data buffer until the terminal receives an Enter command. AFF Affirmative Acknowledge character. See handshake. AID Attention Identifier character. A character in a data stream indicating that the user has pressed a key, such as Enter, requesting an action by the system. alphanumeric Character set containing letters, numbers, and other characters, such as punctuation marks. alphanumeric keypad The alphanumeric keypad on the terminal has 56 keys to type alphabetic and numeric characters. Although the keypad is smaller than a desktop terminal keyboard, you use special keys on the terminal’s keypad and press key combinations to access all the keys and functions. ANSI American National Standards Institute. A non-governmental organization responsible for establishing many standards, including a number of data communications and terminal standards.

G-3

Page 520

TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual

API Application programming interface. A well-defined interface to routines that an application can use to request and perform system-level tasks. application A software program or program package that makes calls to the operating system and manipulates data files allowing a user to perform a specific job. ASCII American Standard Code for Information Interchange. A standard 7-bit code usually transmitted with a parity bit for a total of 8 bits per character. Contrast with “EBCDIC.” ASCII control character One of the first 32 characters (0 through 31 in decimal representation) in the ASCII character set. Each of these characters has a standard control function, such as backspace or carriage return. audio signals The terminal has a beeper and a clicker that produce audio signals to indicate terminal status. You can change the beep volume and enable or disable the keypad clicker with configuration commands. Automatic mode See Scanner mode. automatic shutoff A terminal configuration feature that defines the maximum time the terminal stays on when there is no activity. At automatic shutoff, the contents of terminal memory are saved and the terminal resumes when it is turned on again. backlight A light built into the terminal screen to make it easier to view the screen in dimly lit environments. backup battery See NiCad backup battery. bandwidth The size in hertz of the frequency range that a signal transmission occupies. Typical narrow band signals occupy a 25 KHz bandwidth. The 2.4 GHz radio frequency signal occupies a 1 MHz bandwidth.

G-4

Page 521

Glossary

G bar code density Number of data characters that can be represented in a linear unit of measure. Bar code density is often expressed in characters per inch. bar code label A label that contains a bar code symbol. bar code symbology A scheme for encoding data as bar code. Code 39, Codabar, UPC/EAN, and Interleaved 2 of 5 are examples of different symbologies. battery pack See lithium-ion battery pack. baud rate The number of discreet conditions or signal events per second. In RS-232 and RS422/485 systems, baud rate is the same as bits per second (bps). binary file A file that contains a sequence of 8-bit data characters or executable code. Compare to ASCII text file. Binary files require special software for transmission. boot Usually means to invoke a bootstrap process, which involves building up a system from some simple preliminary instructions or information. A boot invokes the BIOS boot sequence, clears all memory, and performs a complete power-on self test (POST) to ensure that the hardware and peripherals are operational. A boot initializes the system hardware for use by the system firmware and loads the default configuration currently stored in flash memory. bridge An internetworking device that incorporates the physical and data link layers of the OSI model and allows you to connect networks or subnetworks with similar architectures. broadcast A type of transmission in which a message sent from the host is received by many devices on the system. cabled scanner A wand, laser scanner, or other device that scans bar code information. A cabled scanner is connected to a bar code reader or terminal with a cable rather than being built into (integrated in) the reader or terminal.

G-5

Page 522

TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual

CCD scanner Charge-coupled device. A CCD scanner contains no moving parts and uses a light source to illuminate the entire symbol. A symbol is scanned electronically using the digitized image of a line through the symbol provided by the linear photodiode array. CGA Color/graphics adapter. CGA is a video adapter board. channel The path for transmitting data from a device to the host computer. In RF networks, it is the frequency hopping sequence the radio card follows. The 2.4 GHz bandwidth can be divided into 15 channels. check character A character included within a message that performs a check to ensure the accuracy of the message. check digit A character included in a bar code whose value is used to do a mathematical check on the value of the decoded bar code to retain accuracy. checksum A calculated value that is used to test data integrity. Errors can occur when data is transmitted or when it is written to disk. One means of detecting such errors is the use of a checksum. A value is calculated for a given chunk of data by sequentially combining all the bytes of data with a series of arithmetic or logical operations. After the data is transmitted or stored, a new checksum is calculated and compared with the original one. If the checksums match, the transmission or storage was probably error free. If they do not match, an error occurred. coaxial A type of cable used to connect the DCS 300 directly to an IBM host. Coaxial cable consists of an outer layer of insulation, an outer conductor, another insulating layer, and a central conductor. Codabar A self-checking, discrete bar code symbology that has these 16 characters in its set: 0 to 9, dollar sign ($), colon (:), slash (/), period (.), plus (+), and minus (-). Codabar is commonly used in libraries, blood banks, and air-parcel express applications. The American Blood Commission (ABC) Codabar requires that you retain the start/stop code digits when processing a Codabar symbol. The maximum density for a Codabar symbol is 12.8 characters per inch.

G-6

Page 523

Glossary

G

Code 11 A very high density, discrete, numeric bar code developed by Intermec. The character set includes the numbers 0 through 9 and the dash character (-). Each character is represented by a standalone group of three bars with two included spaces. This code is not self-checking. One or two check digits provide data security. Code 11 is most extensively used in labeling telecommunications components and equipment. Its maximum density is 15 characters per inch. Code 16K A two-dimensional (stacked rows), ultra-high density bar code symbology. It is based on Code 128 and is used widely to label unit-dose packaging for the healthcare industry. Code 2 of 5 (2 of 5) A discrete, self-checking code for encoding numeric data only. The bars encode information and the spaces separate individual bars. It can achieve densities of 15 characters per inch. Code 39 A discrete, variable length, and self-checking bar code symbology. The character set is uppercase A to Z, 0 to 9, dollar sign ($), period (.), slash (/), percent (%), space ( ), plus (+), and minus (-). Code 39 can be extended to the full 128 ASCII character set by use of a two-character encoding scheme (see full ASCII). Its maximum density is 9.8 characters per inch. Code 49 A multirow symbology for high data density. The last character in each row is used for row checking and the last two characters of the symbol are used for overall checking. The character set includes all 128 ASCII characters. Its maximum density is 93.3 alphanumeric characters per inch or 154.3 numeric characters per inch. Code 93 A variable length, continuous bar code symbology using four element widths. It can be used interchangeably with Code 39 when higher density printing is required. The character set is the same as Code 39. Its maximum density is 14.8 characters per inch. Code 128 A very high density alphanumeric symbology that supports the extended ASCII character set. It is a variable length, continuous code that uses multiple element widths. Code 128’s high density makes it useful when printing data in a limited space. Its maximum density is 12.1 alphanumeric characters per inch or 24.2 numeric characters per inch.

G-7

Page 524

TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual

Code One A two-dimensional matrix symbology that is useful for applications such as small parts labels that do not have sufficient space for linear bar codes. In addition to data storage and error correction symbols, each Code One symbol contains a set of horizontal lines in the center, called a finder pattern, that helps bar code scanners quickly locate and identify each symbol. Code One symbols also contain vertical reference bars to help bar code scanners locate the relative positions of each data bit. COM port Commonly used short form of communications port. Locations from which data can be passed into and out of the terminal. COM ports offer serial communications, which means that data is transmitted one bit at a time over a single line from one computer to another. communications protocol A set of rules or standards designed to enable computers to connect with each other and exchange data. An example of a communications protocol is configurable serial protocol. configuration The selected parameters that determine the operating characteristics of an electronic device. configuration command A configuration command changes the way the terminal operates. You can enter a configuration command by typing on the keypad, by scanning a bar code label, or by sending a command from a device on the 2.4 GHz network. controller IP address Identifies the IP address assigned to the DCS 300 in the Intermec data collection network. data bits The number of bits the terminal uses when communicating with another device (i.e., host computer). Generally set at seven or eight. data collection device A device used with a scanner that collects data by scanning bar codes and sending this data to a host computer. data transmission An event in which a block of data is transmitted from one device to another.

G-8