The text of a manual · part 24 of 64
Trakker Antares 24XX Terminal User's Manual Addendum, with the Trakker Antares 2420 and 2425 Hand-Held Terminal User's Manual: Chapter 3 - Configuring the Terminal, pages 181 to 188
Pages 181 to 188 of 558, from Trakker Antares 24XX Terminal User's Manual Addendum, with the Trakker Antares 2420 and 2425 Hand-Held Terminal User's Manual
The original document is the PDF (4.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 2420 and Intermec 2425
Page 181
Co de
39 Nugget
3 Configuring the Terminal
Page 182
Co
3-2 de
39 Nugget
Page 183
Configuring the Terminal
3
This chapter explains how to configure the terminal, discusses the terminal’s configuration parameters, and tells you how to restore the default configuration. The table at the end of the chapter lists all the configuration parameters and their options.
How to Configure the Terminal You can configure the TRAKKER Antares 2420 and 2425 terminals by using either of the methods described in detail in this chapter: Using the TRAKKER Antares 2400 Menu System With menus and screens, the TRAKKER Antares 2400 Menu System lets you view the current configuration and modify configuration parameters. Configuring the terminal by scanning bar codes You can change the terminal’s current configuration by scanning Code 39 or Code 93 bar code labels that contain configuration commands. This method is a fast, easy way to change the terminal’s configuration. You can scan the bar code labels in this manual, or you can create your own bar code labels. Note: You can configure the terminals by sending commands from an application through the serial port. You can also configure the T2425 through the network from a DCS 300 or from a host application. For help, see Chapter 4, “Operating the Terminal in a Network.”
Learning About Configuration Parameters You can customize many operating characteristics of the terminals, such as the volume of its audio signals and the bar code symbologies it decodes. These characteristics are controlled by configuration parameters. The values you set for the configuration parameters determine how the terminal operates. By customizing the terminal’s configuration, you can set up the terminal to operate easily and efficiently within your data collection system. Note: To learn the purpose and syntax of each configuration parameter or command, see Chapter 9, “Configuration Command Reference.” The configuration parameters can be organized into three groups, which are discussed in the next sections: bar code symbologies, communications, and general operation. When you configure the terminal, you are performing one or more of these tasks: •
Choosing the Symbologies the Terminal Decodes
•
Specifying How the Terminal Will Communicate
•
Controlling How the Terminal Will Operate
3-3
Page 184
TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual
Choosing the Symbologies the Terminal Decodes This list contains all the bar code symbologies the terminal can decode: •
Codabar
•
Code 39
•
Interleaved 2 of 5 (I 2 of 5)
•
Code 11
•
Code 49
•
MSI
•
Code 16K
•
Code 93
•
Plessey
•
Code 2 of 5
•
Code 128
•
UPC/EAN
When the terminal ships, only these three symbologies are enabled: •
Code 39
•
Code 128
•
UPC/EAN
If you are using one of the other symbologies to encode your bar code labels, you need to configure the terminal and enable the symbology. To quickly enable symbologies, see “Enabling Bar Code Symbologies” in Chapter 1. To ensure that the terminal can operate quickly and efficiently, you should enable only the bar code symbologies that you are going to scan. When you enable each bar code symbology, you may need to set a check digit, the length of the bar code label, or other options. For help, see the bar code symbology in Chapter 9, “Configuration Command Reference.”
Specifying How the Terminal Will Communicate The T2420 uses serial communications to send data to and from another serial device. The T2425 uses radio frequency (RF) communications to communicate with other devices in Intermec’s 2.4 GHz RF network. You can also use the T2425’s serial port to send and receive data. Before you can use the terminal in your wired or wireless network, you must configure the serial port and/or network parameters. On the T2425, you must set the RF network parameters, radio parameters, and address information before the T2425 can communicate with other devices in the 2.4 GHz RF network. To learn how to configure the terminal to fit into your wired or 2.4 GHz RF network, see Chapter 4, “Operating the Terminal in a Network.”
3-4
Page 185
Configuring the Terminal
3
Controlling How the Terminal Will Operate The operating parameters let you adjust the way the terminal operates. By customizing the operating parameters, you can • set the terminal to automatically shut off after a specified length of time.
• set the terminal to resume applications or restart applications.
• modify bar code data by appending the time.
• modify bar code data by using preambles and postambles.
• enable or disable specific reader commands.
• configure a RAM drive.
• change the volume of the audio signals (beeper and keypad clicker).
• control the display contrast, backlight timeout, and font size.
• enable or disable the keypad clicker and keypad caps lock.
• customize the way the scan module operates by selecting scan ahead data buffering, type of scanner device, decode security level, scanner timeout value, and trigger modes.
3-5
Page 186
TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual
Configuring the Terminal With the Menu System The TRAKKER Antares 2400 Menu System is a menu-driven application that lets you configure the terminal, manage files, view system information, and run diagnostics. You can access the TRAKKER Antares 2400 Menu System while running any application. To access the TRAKKER Antares 2400 Menu System •
T 3 , or press T or scan this bar code: Note: You must press the T (Left Enter) key in this key sequence. Press
Enter Test and Service Mode
*..-.* *..-.*
The Main Menu appears, displaying four menu options. Configuration Menu Choose the Configuration Menu to configure bar code symbologies, network and communications parameters, serial port parameters, and the terminal’s operating characteristics. Diagnostics Menu Choose the Diagnostics Menu to run hardware, software, or system diagnostics to help analyze and fix problems on the terminal. You can also view information about batteries and the system. For help, see Chapter 7, “Running Diagnostics.”
242XU.001
System Menu Choose the System Menu to manage files, load the default configuration, set the time and date, store the terminal’s configuration in flash memory, and upgrade the firmware. About TRAKKER 2400 Choose this option to see the part number, firmware version, and RF protocol (UDP Plus or TCP/IP) loaded on the terminal. You may need this information if you are working a problem with an Intermec representative.
3-6
Page 187
3
Configuring the Terminal
The TRAKKER Antares 2400 Menu System at a Glance MAIN MENU
CONFIGURATION MENU Configuration Menu Diagnostics Menu System Menu About TRAKKER 2400
Symbologies Menu Communications Menu Terminal Menu
SYMBOLOGIES MENU *Code 39 Codabar Code 11 Code 49 Code 93 *Code 128 Code 16K 2of5 / I 2of5 MSI Plessey *UPC / EAN
SYSTEM MENU File Manager Load Default Values Set Time and Date Store Configuration Upgrade Firmware ⁄
CONFIGURATION MENU Symbologies Menu Communications Menu Terminal Menu
DIAGNOSTICS MENU
COMMUNICATIONS MENU
Software Diagnosticss Hardware Diagnostics System Diagnostics
Serial Port [COM1] Serial Port [COM4]
T2420
⁄
⁄
SOFTWARE DIAGNOSTICS
COMMUNICATIONS MENU
Error Logger Application Events Task Status Clear Task Profiles
Primary Network Advanced Network Radio Serial Port [COM1] Serial Port [COM4]
T2425
⁄
⁄ HARDWARE DIAGNOSTICS
CONFIGURATION MENU
Hardware Config Battery/PIC Status Display Test Keypad Test Main Board Menu Radio Test Scanner Test
⁄
Symbologies Menu Communications Menu Terminal Menu
SYSTEM DIAGNOSTICS Subsystem Versions Access Point App Efficiency Serial Port Test Malloc Info Menu
TERMINAL MENU Append Time Beeper Display Keypad Power Management Preamble/Postamble RAM Drive Reader Command Menu Scanner
242XU.178
3-7
Page 188
TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual
Exploring the Configuration and System Menus When you access the TRAKKER Antares 2400 Menu System, the Main Menu appears. You use the Configuration Menu and the System Menu to configure the terminal. The Configuration Menu contains these commands: CONFIGURATION MENU Symbologies Menu Communications Menu Terminal Menu
_` Select item [Enter] Next screen [F1] Help [Esc] Exit 242XU.010
Symbologies Menu Choose the Symbologies Menu to configure and activate the bar code symbologies the terminal can decode. An asterisk (*) on the Symbologies Menu indicates that the symbology is active. For help, see “Choosing the Symbologies the Terminal Decodes” earlier in this chapter. Communications Menu Choose the Communications menu to configure the primary network parameters, the advanced network parameters, the radio parameters, or the serial port parameters. On a T2420, only the serial port option is visible since the terminal has no radio. For help, see Chapter 4, “Operating the Terminal in a Network.” Terminal Menu Choose the Terminal Menu to configure the way the terminal, keypad, scanner, or screen operate. For help, see “Controlling How the Terminal Will Operate” earlier in this chapter. The System Menu contains these commands: SYSTEM
MENU
File Manager Load Default Values Set Time and Date Store Configuration Upgrade Firmware
_` Select item [Enter] Next screen [F1] Help [Esc] Exit 242XU.051
3-8