Trakker Antares 241X Handheld Terminal Quick Start Guide, pages 11 to 20

Pages 11 to 20 of 20

The original document is the PDF (269 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Intermec 2410 and Intermec 2415

Page 11

C d

39 nuggetfont

5 Press \, and then press % twice to exit the TRAKKER Antares 2400 Menu System. Choose OK to save your changes. If you are using the Wavelink Avalanche client management system, you can quickly configure the parameters for your terminal. For help, see Chapter 2, “Configuring and Managing the Terminals” in the 2400 Family system manual.

(Optional) Configure the Serial Port Parameters You can connect the terminal to a host computer, PC, or other RS-232 device by using a special cable (P/N 069589). Or, you can insert the terminal into the communications dock, and then connect the dock to the RS-232 device. The values you set for the terminal’s serial port parameters must match the values set for the host’s (or other device’s) serial port parameters. Press ( \ 2 4 8 to access the TRAKKER Antares 2400 Menu System. Choose Configuration Menu > Communications Menu > Serial Port [COM1]. SERIAL PORT [COM1] Protocol: Configurable Baud Rate: 19200 Parity: Even Data Bits: 7 Stop Bits: 1 more

241XG001.eps

Serial Port [COM1] Menus

Trakker Antares 241X Handheld Terminal Quick Start Guide

11

Page 12

C d

39 nuggetfont

(2415 Only) Configure the Network Parameters Before you can use the 2415, you must install and configure the host and access points. You may also need to install and configure the Intermec Gateway or DCS 30X. Depending on your network protocol, the 2415 can communicate with a host computer either through access points and the Intermec Gateway or DCS 30X (UDP Plus or WTP network) or directly through the access points (TCP/IP network). Press ( \ 2 4 8 to access the TRAKKER Antares 2400 Menu System. Choose Configuration Menu > Communications Menu > Primary Network or Advanced Network. You need to obtain most of these settings from your network administrator. Note: If you are using the WTP network, you only need to configure the Primary Network parameters. To configure the Primary Network parameters 1 Make sure that 2.4 GHz RF (OpenAir radio) or 802.11 DS (802.11b radio) appears in the Activate field. If you are using the WTP network, you only need to configure the Activate field. 2 (UDP Plus) In the Controller IP Address field, enter the IP address of the Intermec Gateway or DCS 30X in your network. The IP address must be in the form n.n.n.n, where each n is a number from 0 to 255. You must separate each n by a period. (TCP/IP) In the Host IP address field, enter the IP address of the host that you want the terminal to communicate with. The IP address must be in the form n.n.n.n, where each n is a number from 0 to 255. You must separate each n by a period. 3 In the Terminal IP Address field, enter the IP address of the terminal. The IP address must be in the form n.n.n.n, where each n is a number from 0 to 255. You must separate each n by a period.

12

Trakker Antares 241X Handheld Terminal Quick Start Guide

Page 13

C d

39 nuggetfont

If you are using a DHCP (Dynamic Host Configuration Protocol) server, you can leave the default terminal IP address as 0.0.0.0 to enable the 2415 as a DHCP client. For help, see “DHCP (Terminal)” in the 2400 Family system manual. To configure the Advanced Network parameters Note: If the Intermec Gateway, DCS 30X, or host is on a different subnetwork from the terminal, you must configure the subnet mask and the default router. 1 In the Subnet Mask field, enter the mask that is used to separate the subnetwork address from the terminal IP address. The subnet mask must be in the form n.n.n.n, where each n is either 0 or 255. You must separate each n by a period. ADVANCED NETWORK Loopback: Disabled Network Port: O5555 Subnet Mask: 255.255.255.0 Default Router 0.0.0.0. Controller Connect Chk Send Timer: 0035 sec Recv Timer: 0060 sec Retries: 07 more

241XG003.eps

2 In the Default Router field, enter the IP address of the default router. The IP address must be in the form n.n.n.n, where each n is a number from 0 to 255. You must separate each n by a period.

(2415 Only) Configure the Radio Parameters The 2415 communicates with a host computer in an RF network either through access points and the Intermec Gateway or DCS 30X or directly through the access points. All RF devices that must communicate with each other must contain the same radios. The terminal ships with one of these radio options: WLI Forum OpenAir or IEEE 802.11b. Trakker Antares 241X Handheld Terminal Quick Start Guide

13

Page 14

C d

39 nuggetfont

Depending on the radio that is in the devices, you must match certain parameters on the 2415s and on the access points. Press ( \ 2 4 8 to access the TRAKKER Antares 2400 Menu System. Choose Configuration Menu > Communications Menu > Radio. To configure the OpenAir radio parameters 1 In the Domain field, enter a number from 0 to 15. The terminal can only communicate with access points that have the same domain. 2 In the Security ID field, enter up to 20 alphanumeric characters or leave the field blank. The terminal can only communicate with access points that have the same security ID. To configure the 802.11b radio parameters 1 In the Network Name field, enter up to 32 alphanumeric characters. The terminal can only communicate with access points that have the same network name 2 Configure the security parameters: • (non-802.1x security) Enable WEP Encryption and select a WEP Transmit Key. Enter a WEP key value: WEP 64 requires 5 ASCII characters or hex pairs, and WEP 128 requires 13 ASCII characters or hex pairs. • (802.1x security) Configure the User Name and Password.

Choosing Your TE 2000 Configuration If you have a TE 2000 application, your terminal is configured for TE 2000 VT/ANSI by default. You may need to change the configuration to TE 2000 5250 or TE 2000 3270.

14

Trakker Antares 241X Handheld Terminal Quick Start Guide

Page 15

C d

39 nuggetfont

To change the TE 2000 configuration 1 On your terminal, press ) !. If you have a 37-key keypad, press ( 5. The TE 2000 main menu appears. Main Menu 1) 2) 3) 4) 5) 6) 7)

Set-up Parms LCD Parms Tests Version Info Exit Menus More

24XXS080.eps

2 Select Set-up Parms and press \. A password prompt appears. 3 Type C R 5 2 4 0 1 and press \. 4 Select Protocol Opts, Data Stream, and then select the appropriate TE 2000 configuration. 5 Save your changes by selecting Exit Menus from the TE 2000 main menu. Press Y, and type C R 5 2 4 0 1 at the Enter Password prompt. For help using TE 2000 terminal emulation, see the appropriate TE 2000 guide listed on page 19.

Using the Keypad Characters, symbols, and functions are printed in four places on or above the keys. The keys are also color-coded to make it easier to remember key combinations.

Trakker Antares 241X Handheld Terminal Quick Start Guide

15

Page 16

C d

39 nuggetfont

Using the Keypad Position on the Keypad

Color

Middle of the key

To Type the Character White

Left side above the key

Orange

Press the orange ( key, then press the key.

Centered above the key

Pink

Press the pink ? key, then press the key.

Right side above the key

Green

Press the green ) key, then press the key.

Note: The 37-key international keypad has five different keys that you can access. To type the light green character printed on the far right side above the key, press the a key, and then press the key. You can also use the arrow keys to move around an application screen. To go up or down the screen, press = or >. To go left or right, press ( = or ( >.

Learning About the Bar Code Symbologies Although the terminal can decode many types of bar code symbologies. These symbologies are enabled when you unpack the terminal: Code 39, Code 128, PDF417 (PDF417 scanner option only), and UPC/EAN. You need to configure the terminal to decode the bar code symbology used in your bar code labels. Only enable the bar code symbologies that you need to scan.

Learning About the Status LEDs You can use the status LEDs to monitor the status of bar code scanning, network communications, special keys, and battery power. These LEDs only blink or turn on to indicate the current status. The Battery LED is amber and all other LEDs are green.

241XG018.eps

16

Trakker Antares 241X Handheld Terminal Quick Start Guide

Page 17

C d

39 nuggetfont

Status LED Descriptions Icon

Name

Description

Good Read

This LED turns on when you successfully scan a bar code label.

User Defined

This LED is user defined. You can program this LED to turn on and off for any task or error within your application.

Network Connect

The Network Connect LED may be on, off, or blinking.

Modifier

This LED indicates that one of the modifier keys, such as a, is active. If Caps Lock is enabled, this LED remains on until you disable Caps Lock.

Battery

This LED turns on when there is a low battery charge and the terminal is on.

Changing the Beep Volume The terminal has a beeper that provides you with audio feedback as you use the terminal. You can change the beep volume to meet the needs of your working environment. When you change the beep volume, you will also change the keyclick volume if the Keypad Clicker command is enabled. The keyclick is the sound that you hear when you press a key on the terminal. There are two ways to change the beep volume:

• Use the Backlight key (press ) +) on the keypad. Each time you press ) +, it makes the beep volume one level louder. On the 241X, there are three beep volume levels including off. If the volume is at the loudest level and you press ) +, the beep volume is turned off. If you press ) + again, the volume changes to the quietest level.

• Use the Beep Volume command. For help, see “Beep Volume” in Chapter 6 of the 2400 Family system manual.

Trakker Antares 241X Handheld Terminal Quick Start Guide

17

Page 18

C d

39 nuggetfont

Useful Bar Codes Backlight On

Backlight Off

*%.1*

*%.0*

Darker Display Contrast

Brighter Display Contrast

*%.1*

*$+DJ9*

*%.0*

*$+DJ8*

*$+DJ9*

*$+DJ8*

Raise Beep Volume

Lower Beep Volume

*$+BV9*

*$+BV8*

*$+BV9*

*$+BV8*

Enter Accumulate Mode

Exit Accumulate Mode

*+/*

*-/*

Default Configuration

Reset Firmware

*.+0*

*-.*

Save Configuration in Flash Memory

Boot Terminal

*.+1*

*-.1*

*+/*

*.+0*

*.+1*

*-/*

*-.*

*-.1*

TRAKKER Antares 2400 Menu System

*..-.* *..-.*

Specifications This section lists some specifications for the terminals. For a complete list of specifications, see Appendix A, “Specifications,” in the user’s manual.

Physical Dimensions Length:

19.3 cm (7.6 in)

Height:

5.6 cm (2.2 in) at scanner 3.0 cm (1.2 in) at grip

18

Trakker Antares 241X Handheld Terminal Quick Start Guide

Page 19

C d

Width: Weight:

39 nuggetfont

8.4 cm (3.3 in) at scanner 5.1 cm (2.0 in) at grip 2410 - 374 g (13.2 oz) 2415 - 422 g (14.9 oz)

Power Specifications Operating: Rechargeable lithium-ion 1350 mAh or 2400 mAh battery pack Rechargeable lithium-ion 2400 mAh or 4800 mAh battery pack Backup:

Rechargeable capacitor

Electrical Specifications Electrical Rating: x 4V; 1A

Where to Go From Here Now that your new terminal is working, you may need additional information to use the 241X in your data collection system: • The Trakker Antares 241X Handheld Terminal User’s Manual (P/N 069538) and the Trakker Antares 2400 Family System Manual (P/N 071389) contain all the information necessary to configure, operate, and troubleshoot the 241X. • These TE 2000 terminal emulation guides provide information about how to configure TE 2000 terminal emulation: the TE 2000 5250 Terminal Emulation Programmer’s Guide (P/N 977-055-004), the TE 2000 3270 Terminal Emulation Programmer’s Guide (P/N 977-055-003), and the TE 2000 VT/ANSI Terminal Emulation Programmer’s Guide (P/N 977-055-005). • For additional help using dcBrowser, see the online help that ships with the dcBrowser gateway software, or see the Data Collection Browser Client User’s Guide (P/N 070011). The Intermec web site at www.intermec.com provides our current manuals as PDF files for you to download. To order accessories and printed documentation, contact your local Intermec representative.