Page 49
Chapter 2 - Configuring and Managing the Terminals
Saving Configuration Changes in Flash Memory If you configure the terminal by scanning bar code labels, using the serial port, or using the network, you may want to save the changes in flash memory by: • scanning the Save Configuration in Flash Memory reader command bar code label. • sending the Save Configuration in Flash Memory reader command through the network. • using the TRAKKER Antares 2400 Menu System. To save configuration changes by scanning a bar code label • Scan this bar code label: Save Configuration in Flash Memory
*.+1*
*.+1*
To save configuration changes by sending a command through the network • Send .+1 as the last command from the host application or the DCS 300. To save configuration changes using the menu system 1 Press ) ; 2 4 8 or scan this bar code: TRAKKER Antares 2400 Menu System
*..-.*
*..-.*
The Main Menu appears. 2 Choose System Menu > Store Configuration. The Store Configuration screen appears. Store configuration changes in flash memory? (used when rebooting the terminal)
Yes
No
CANCEL
24XXS033.eps
Trakker Antares 2400 Family System Manual
29
Page 50
Chapter 2 - Configuring and Managing the Terminals
3 Choose Yes to save the configuration in flash memory. To exit without saving the configuration, choose Cancel. The System Menu appears. 4 Press d to exit the System Menu. The Main Menu appears. 5 Choose another menu from the Main Menu or press d to exit the TRAKKER Antares 2400 Menu System.
Restoring the Terminal’s Default Configuration The default configuration for the terminal is listed starting on page 272. You can restore the terminal’s default configuration by: • scanning the Default Configuration bar code label. • sending a command through the network. • using the TRAKKER Antares 2400 Menu System. If you restore the default configuration, you need to set the primary network communications parameters on the RF terminal to reestablish communications with other devices in the RF network. You may also need to reset the serial port or Ethernet parameters to communicate with other devices in your wired network. To restore the default configuration by scanning a bar code label • Scan this bar code label: Default Configuration
*.+*
*.+*
To restore the default configuration by sending a command through the network • Send .+0 from the host application or the DCS 300. To restore the default configuration using the menu system 1 Press ) ; 2 4 8 or scan this bar code: TRAKKER Antares 2400 Menu System
*..-.*
*..-.*
The Main Menu appears. 2 Choose System Menu > Load Default Values. The Load Default Values screen appears.
30
Trakker Antares 2400 Family System Manual
Page 51
Chapter 2 - Configuring and Managing the Terminals
LOAD DEFAULT VALUES Load default configuration values in RAM? (Overwrites current configuration)
OK
CANCEL 24XXS034.eps
3 Choose OK and press ; to load the default configuration values. The default values will override the current runtime configuration on the terminal. To exit without loading the default values, choose Cancel and press ;. The System Menu appears. 4 Press d to exit the System Menu. The Main Menu appears. 5 Choose another menu from the Main Menu or press d to exit the TRAKKER Antares 2400 Menu System.
Upgrading the Terminal This section explains how to upgrade the firmware on the terminal and how to load double-byte fonts, if you choose to order them after you receive your terminal. You can also upgrade the terminal for: • TE 2000 (new releases) • Data Collection Browser™ (dcBrowser™) For pricing and availability, contact your local Intermec representative.
Upgrading the Firmware When you upgrade the firmware, you remove existing applications and files on the terminal and restore the terminal’s default configuration. Make sure you back up your custom files and applications, such as TE 2000, dcBrowser, and ROM-DOS™, so that you can reinstall them after the upgrade procedure. For help, see “Using the Serial Port to Transfer Applications and Files” on page 55. You will need to set the primary network communications parameters on the RF terminal to reestablish communications with other devices in the RF network. You may also need to reset the serial port or Ethernet parameters to communicate with other devices in your wired network.
Trakker Antares 2400 Family System Manual
31
Page 52
Chapter 2 - Configuring and Managing the Terminals
Note: Trakker Antares Native terminal emulation is only supported on terminals with firmware version 6.23 and earlier. If you want to upgrade your firmware to version 7.0 or later and continue to use a terminal emulation application, you can order TE 2000. For help, see your local Intermec sales representative. You can download the latest version of firmware from the Intermec web site at www.intermec.com. When you download the firmware files, you will be prompted to also download the Trakker Antares Firmware Upgrade Utility (TAUPGRADE.EXE) and the FileCopy application (FILECOPYx.x.EXE, where x.x is the version number). Download TAUPGRADE.EXE if you are using a PC with Microsoft Windows 2000/NT/XP. Download FILECOPYx.x.EXE if you have or need to load TE 2000 on your terminal. You can upgrade your terminal firmware using the: • Trakker Antares DOS Firmware Upgrade Utility (UPGRADE.BAT). This utility is included with the firmware upgrade. You can use this utility to upgrade the firmware using an MS-DOS window on a PC with Microsoft Windows 95/98. If you want to use the DOS Firmware Upgrade Utility on a PC with Windows 2000/NT/XP, you can follow the upgrade procedure through Step 13. Print the UPGRADE.BAT file. Identify the numbers that are associated with the menu selections in Steps 15 through 18. When you get to Step 14, type: UPGRADE X X X X where the Xs represent the menu selection numbers. • Trakker Antares Firmware Upgrade Utility (TAUPGRADE.EXE). This utility is available at no charge from the Intermec web site at www.intermec.com. It allows you to upgrade the terminal firmware using a Microsoft Windows interface on a PC with Microsoft Windows 2000/NT/XP. Note: The Trakker Antares Firmware Upgrade Utility cannot be used to upgrade terminals with 802.1x security. • Firmware Upgrade Utility on the DCS 300. This section describes how to use the DOS Firmware Upgrade Utility and the Trakker Antares Firmware Upgrade Utility. For help using the Firmware Upgrade Utility on the DCS 300, see the DCS 300 User’s Manual.
32
Trakker Antares 2400 Family System Manual
Page 53
Chapter 2 - Configuring and Managing the Terminals
To upgrade the firmware using the Trakker Antares DOS Firmware Upgrade Utility Note: Make sure you back up your custom files and applications, such as TE 2000, dcBrowser, and ROM-DOS, so that you can reinstall them after the upgrade procedure. For help, see “Using the Serial Port to Transfer Applications and Files” on page 55. 1 Open the MS-DOS window, and then open the MS-DOS Prompt Properties dialog box. On the Memory tab, set the Initial Environment field to 4096. Close the MS-DOS window and re-open it. 2 Connect the terminal to a PC running Windows 95/98. For help see your user’s manual. 3 Create a new directory on your PC. 4 Copy these five upgrade files to the directory that you created in Step 3: • INSTALL.BAT • INSTALL.INF • README.TXT • TKANTxxx.EXE, where xxx is the firmware revision number. Or, TKVxxxxx.EXE, where xxxxx is the field trial release number. • WHATSNEW.TXT Note: If you are using Wavelink Avalanche, copy all of the Avalanche (.AVA) files in addition to the upgrade files. 5 Access the MS-DOS window. 6 Change to the directory where the upgrade files are located. 7 Type: INSTALL
The batch file explodes the TKANTxxx.EXE or TKVxxxxx.EXE file to a new directory. This new directory contains all the files you need to perform an upgrade. 8 On the terminal, press ) ; 2 4 8 or scan this bar code label: TRAKKER Antares 2400 Menu System
*..-.*
*..-.*
The Main Menu appears.
Trakker Antares 2400 Family System Manual
33
Page 54
Chapter 2 - Configuring and Managing the Terminals
9 Choose System Menu > Upgrade Firmware. The Upgrade Firmware screen appears. UPGRADE
FIRMWARE
Upgrade terminal firmware? Make sure the terminal is connected to a
OK host
CANCEL 24XXS035.eps
10 Choose OK to continue. The next screen appears. Are you want to sure you continue?
Selecting YES will upgrade and replace all of the terminal's firmware. Selecting NO will exit without upgrading firmware.
YES
NO 24XXS036.eps
11 Choose Yes to continue and upgrade the firmware. The terminal reboots and then displays the Loader Waiting screen. If you reach the Loader Waiting screen and cannot upgrade or continue, press d once or œ twice to exit without upgrading the firmware. The Boot Menu appears. Press 2 or L to access the Loader Waiting screen. 12 On your PC in the MS-DOS window, change to the directory that contains the upgrade files in Step 6. 13 Type: UPGRADE
A menu appears asking you to select a communications port. If you are using Windows 2000/NT/XP, print the UPGRADE.BAT file. Identify the numbers that are associated with the menu selections in Steps 15 through 18. Type: UPGRADE X X X X where the Xs represent the menu selection numbers.
34
Trakker Antares 2400 Family System Manual
Page 55
Chapter 2 - Configuring and Managing the Terminals
14 Select a communications port: Type This Value 1
Communications Port COM1
2
COM2
3
COM3
4
COM4
A menu appears asking you to select a download speed. 15 Select a download speed: Type This Value 1
Download Speed 9600 baud
2
19200 baud
3
38400 baud
4
57600 baud
5
115200 baud
A menu appears asking you to select which protocol stack to use. 16 Select a protocol stack: Type This Value 1
Protocol Stack UDP Plus
2
TCP/IP
3
Batch/Serial
4
WTP
A menu appears asking you to select the communication hardware for your terminal. 17 Select the communications hardware: Type This Value 1
Communications Hardware OpenAir radio
2
802.11b radio
3
Ethernet
4
802.11b radio and 802.1x TTLS security
5
802.11b radio and 802.1x LEAP security
Note: You can only select 802.11b radio and TTLS or LEAP security if you selected TCP/IP in Step 17 and you have either the 802.1x security option or the 4MB flash memory. The Loader screen appears and begins downloading the firmware and application to the terminal. Trakker Antares 2400 Family System Manual
35
Page 56
Chapter 2 - Configuring and Managing the Terminals
18 When you are done upgrading the firmware, the terminal returns to its default configuration. You will need to reconfigure the terminal. For help, see “How to Configure the Terminals” on page 12. 19 If necessary, reload your custom applications and files on the terminal. For help, see “Using the Serial Port to Transfer Applications and Files” on page 55. To upgrade the firmware using the Trakker Antares Firmware Upgrade Utility Note: Make sure you back up your custom files and applications, such as TE 2000, dcBrowser, and ROM-DOS, so that you can reinstall them after the upgrade procedure. For help, see “Using the Serial Port to Transfer Applications and Files” on page 55. 1 The Trakker Antares Firmware Upgrade Utility is included with the firmware upgrade. Install the utility (TAUPGRADE.EXE) on your PC. 2 Use the online help that ships with the utility to upgrade the firmware on your terminal. 3 If necessary, reload your custom applications and files on the terminal. For help, see “Using the Serial Port to Transfer Applications and Files” on page 55.
Loading Double-Byte Fonts If you ordered the optional 4MB flash drive (drive D), you can order a double-byte font and load the font on your terminal. To order a doublebyte font, contact your local Intermec representative. Note: Double-byte fonts are not available for terminals with the 802.1x security option. You can also order the Thai language font as a configuration option for the Trakker Antares 2400 Family. For help, contact your local Intermec representative. Use the next table to determine which file name you need. Double-Byte Fonts
36
Language
File Name
Simplified Chinese, VT
24DBCSCT.FON
Simplified Chinese, 5250
24DBCSCL.FON
Japanese EUC (unix), VT
24DBCSJT.FON
Japanese, 5250
24DBCSJL.FON
Korean, VT
24DBCSKT.FON
Korean, 5250
24DBCSKL.FON
Trakker Antares 2400 Family System Manual
Page 57
Chapter 2 - Configuring and Managing the Terminals
Double-Byte Fonts (continued) Language
File Name
Big 5 Chinese, VT
24DBCSTT.FON
Big 5 Chinese, 5250
24DBCSTL.FON
Note: If you are using a Japanese double-byte font, the cursor symbol is represented by an arrow symbol. If you have a 241X terminal, you may also need to order a keypad overlay to use the double-byte font. For more information, contact your local Intermec representative. To load a double-byte font 1 Connect your terminal to a PC running Windows 95/98. For help, see your user’s manual. 2 On your PC, copy the FLOADER.EXE application and the doublebyte font file into a directory. 3 On your terminal, press ) ; 2 4 8 or scan this bar code label: TRAKKER Antares 2400 Menu System
*..-.*
*..-.*
The Main Menu appears. 4 Choose System Menu > Upgrade Firmware. The Upgrade Firmware screen appears. 5 Choose OK to continue. 6 Choose Yes to continue and upgrade the firmware. The terminal reboots and displays the Loader Waiting screen. Note: If you reach the Loader Waiting screen and cannot upgrade or continue, press d once or œ twice to exit without upgrading the firmware. The Boot Menu appears. Press 2 or L to access the Loader Waiting screen. 7 On your PC, access the MS-DOS window. 8 At the prompt, change to the directory that contains the double-byte font.
Trakker Antares 2400 Family System Manual
37